Centrifuge
Filter
Showing 1–30 of 229 results
| Origin | United Kingdom |
|---|---|
| Type | Benchtop Centrifuge |
| Maximum Speed | 10,000 rpm |
| Maximum RCF | 12,300 × g |
| Rotor Type | Fixed-angle |
| Standard Rotor Capacity | 12 × 1.5/2.0 mL tubes |
| Optional Rotor Capacity | 32 × 0.2 mL PCR tubes |
| Acceleration Time | <12 s |
| Deceleration Time | <16 s |
| Rotor Material | Corrosion-resistant polymer |
| Sterilization | Autoclavable (121 °C, 20 min) |
| Display | LCD |
| Brand | Agilent Technologies |
|---|---|
| Origin | Singapore |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported Instrument |
| Model | VSpin |
| Instrument Type | Benchtop Centrifuge |
| Form Factor | Robotic-Accessible, Compact Footprint |
| Cycle Time | ≤3 seconds (load + spin + unload) |
| Compatibility | Standard SBS-format microplates (96-well, 384-well, 1536-well), PCR plates, deep-well plates, skirted/unskirted formats |
| Drive System | Brushless DC motor with closed-loop speed control |
| Vibration Isolation | Integrated passive damping mounts |
| Automation Interface | RS-232, Ethernet (TCP/IP), and optional TTL I/O for robotic handshake protocols |
| Brand | Allsheng |
|---|---|
| Origin | Zhejiang, China |
| Model | iCEN-24R |
| Instrument Type | Benchtop Centrifuge |
| Speed Range | 500–15,000 rpm (in 100 rpm increments) |
| Max RCF | 21,400 × g |
| Max Capacity | 24 × 1.5/2.0 mL tubes |
| Temperature Range | −10 °C to +40 °C |
| Cooling Performance | Maintains 4 °C at maximum speed |
| Pre-cooling Time | ≤20 min (from ambient to 4 °C) |
| Noise Level | <60 dB(A) |
| Acceleration/Deceleration Time | 15 s (soft off), 45 s (soft on) |
| Rotor Material | Anodized aluminum alloy, autoclavable |
| Dimensions (L×W×H) | 300 × 500 × 320 mm |
| Net Weight | 28 kg |
| Power Supply | AC 100–120 V / 200–240 V, 50–60 Hz |
| Compliance | CE, IEC 61010-2-020 |
| Brand | Allsheng |
|---|---|
| Origin | Zhejiang, China |
| Model | Mini-10K |
| Instrument Type | Palm-Sized Centrifuge |
| Max Speed | 10,000 rpm |
| Max RCF | 5,000 × g |
| Capacity | 6 × 1.5 mL / 2.0 mL microtubes |
| Power Supply | AC 100–240 V, 50/60 Hz |
| Motor | Brushless DC motor |
| Rotor Type | Fixed-angle rotor (standard) |
| Safety | Auto-braking on lid opening, reinforced composite lid, carbon-fiber rotor body |
| Noise Level | ≤45 dB(A) |
| Dimensions | 145 × 155 × 115 mm (W × D × H) |
| Weight | 1.8 kg |
| Compliance | CE, RoHS, IEC 61010-1 |
| Brand | Allsheng |
|---|---|
| Origin | Zhejiang, China |
| Model | Mini-6KC |
| Instrument Type | Palm-Sized Centrifuge |
| Speed Settings | 4,000 rpm & 6,000 rpm |
| Max RCF | 1,200 × g (at 4,000 rpm) / 2,000 × g (at 6,000 rpm) |
| Capacity | 8 × 1.5 mL / 2.0 mL tubes |
| Dimensions (W × D × H) | 147 mm × 107 mm × 135 mm |
| Weight | 0.7 kg |
| Power Supply | AC 100–240 V, 50/60 Hz |
| Brand | Allsheng |
|---|---|
| Origin | Zhejiang, China |
| Model | Mini-6KS |
| Instrument Type | Palm-Sized Centrifuge |
| Speed Settings | 4,000 rpm & 6,000 rpm |
| Max RCF | 1,200 × g (at 4,000 rpm) / 2,000 × g (at 6,000 rpm) |
| Capacity | 6 × 1.5/2.0 mL tubes |
| Dimensions (W × D × H) | 135 × 147 × 120 mm |
| Weight | 0.7 kg |
| Power Supply | AC 100–240 V, 50/60 Hz |
| Rotor Material | Carbon Fiber |
| Motor Type | Brushless DC Motor |
| Safety | Automatic Rotor Stop on Lid Opening |
| Compliance | CE-marked per IEC 61010-1 for laboratory equipment |
| Brand | Allsheng |
|---|---|
| Origin | Zhejiang, China |
| Model | Mini-7K |
| Instrument Type | Palm-Sized Centrifuge |
| Maximum Speed | 7,000 rpm |
| Maximum RCF | 2,300 × g |
| Capacity | 6 × 1.5 mL / 2.0 mL tubes or 2 × 8 × 0.2 mL PCR strips |
| Power Supply | AC 100–240 V, 50/60 Hz |
| Motor Type | Brushless DC Motor |
| Housing Material | Impact-Resistant Composite |
| Safety Features | Lid-Actuated Auto-Stop & Auto-Start, No-Coast Braking |
| Noise Level | <45 dB(A) |
| Dimensions (W × D × H) | 165 × 155 × 115 mm |
| Weight | 1.2 kg |
| Power Consumption | 30 W |
| Brand | Allsheng |
|---|---|
| Origin | Zhejiang, China |
| Model | MPC-P25 |
| Instrument Type | Benchtop Centrifuge |
| Category | Low-Speed Centrifuge (≤2,200 rpm) |
| Rotor Configuration | Horizontal Swinging-Bucket Rotor |
| Max Capacity | 2 × microplates (96-well or 384-well PCR/ELISA plates), 24 × 0.2 mL PCR strips, or 192 × 0.2 mL PCR tubes |
| Max Speed | 2,200 rpm |
| Max RCF | 480 × g |
| Timer Range | 0–10 min |
| Dimensions (W×D×H) | 290 × 360 × 140 mm |
| Weight | 3.6 kg |
| Power Supply | AC 120 V / 220 V, 50 / 60 Hz |
| Safety Features | Automatic braking (brake time ≈ 30 s), transparent lid with interlock, soft-start/soft-stop control |
| Brand | Allsheng |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | TD2-24 |
| Quotation | Upon Request |
| Speed Range | 500–1500 rpm |
| RCF Range | 33–294 × g |
| Capacity | 24 columns (6- or 8-column immunohematology cards) |
| Timer Range | 1–20 min |
| Noise Level | ≤55 dB(A) |
| Power Supply | AC 100–240 V, 50/60 Hz, 3 A |
| Power Consumption | 85 W |
| Dimensions (L×W×H) | 530 × 410 × 180 mm |
| Weight | 11.5 kg |
| Brand | Analysis |
|---|---|
| Origin | Spain |
| Manufacturer | Ortoalresa S.L. |
| Model | BIOCEN 22R |
| Instrument Type | Benchtop Centrifuge |
| Speed Range | 200–18,100 rpm |
| Max RCF | 31,865 × g |
| Max Capacity | 8 × 15 mL |
| Temperature Range | –20 °C to +40 °C (1 °C increments) |
| Refrigerant | R-449A (HFO-based, non-CFC) |
| Dimensions (W×D×H) | 276 × 640 × 272 mm |
| Noise Level | <65 dB(A) |
| Compliance | EN 61010-1, EN 61010-2-101, EN 61010-2-020, EN 61326-1, EN 61326-2-6 |
| Safety Certifications | 2011/65/EU (RoHS), 2012/19/EU (WEEE), 2014/30/EU (EMC), 2014/35/EU (LVD), 98/79/EC (IVDR), (EC) No 1005/2009, (EU) No 517/2014 |
| Brand | Analysis |
|---|---|
| Origin | Spain |
| Manufacturer Type | Manufacturer |
| Product Category | Imported |
| Model | Bioprocen 22 R |
| Instrument Type | Benchtop Centrifuge |
| Speed Range | High-Speed (10,000–30,000 rpm) |
| Function | Refrigerated Centrifuge |
| Configuration | Fixed-Angle Rotor Centrifuge |
| Max Capacity | 6 × 50 mL |
| Max Speed | 18,100 rpm |
| Max RCF | 31,865 × g |
| Dimensions (W×D×H) | 410 × 690 × 320 mm |
| Brand | Analysis |
|---|---|
| Origin | Spain |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported |
| Model | CONSUL22 |
| Instrument Type | Benchtop Centrifuge |
| Speed Range | 100–14,300 rpm |
| Maximum RCF | 21,948 × g |
| Maximum Capacity | 4 × 400 mL |
| Dimensions (W×D×H) | 490 × 600 × 400 mm |
| Noise Level | <60 dB(A) |
| Power Supply | 220–230 V / 50–60 Hz or 110–120 V / 50–60 Hz |
| Power Consumption | 620 W |
| Rotor Recognition | Automatic |
| Safety Compliance | EN 61010-1, EN 61010-2-101, EN 61010-2-020, EN 61326-1, EN 61326-2-6 |
| Regulatory Directives | 2011/65/EU (RoHS), 2012/19/EU (WEEE), 2014/30/EU (EMC), 2014/35/EU (LVD), 98/79/EC (IVDD) |
| Brand | Analysis |
|---|---|
| Origin | Spain |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported |
| Model | MICROCEN 24 |
| Centrifuge Type | Benchtop Centrifuge |
| Speed Range | 0–8,000 rpm |
| Relative Centrifugal Force (RCF) | up to 6,511 × g |
| Maximum Capacity | 10 × 15 mL conical tubes |
| Rotor Configuration | Fixed-angle rotor (standard 8 × 15 mL), interchangeable rotor compatibility |
| Dimensions (W×D×H) | 270 × 380 × 270 mm |
| Net Weight | 16 kg |
| Power Supply | 220–230 V / 50–60 Hz (CE202) or 110–120 V / 50–60 Hz (CE203) |
| Power Consumption | 280 W |
| Noise Level | <60 dB(A) |
| Safety Compliance | EN 61010-1, EN 61010-2-101, EN 61010-2-020, EN 61326-1, EN 61326-2-6 |
| Regulatory Directives | 2011/65/EU (RoHS), 2012/19/EU (WEEE), 2014/30/EU (EMC), 2014/35/EU (LVD), 98/79/EC (IVDD) |
| Brand | Analysis |
|---|---|
| Origin | Spain |
| Manufacturer Type | Manufacturer |
| Origin Category | Imported |
| Model | MINICEN |
| Instrument Type | Benchtop Centrifuge |
| Speed Range | High-Speed Centrifuge (10,000–30,000 rpm) |
| Function | General-Purpose Centrifuge |
| Configuration | Fixed-Angle Rotor Centrifuge |
| Maximum Capacity | 12 × 1.5–2 mL |
| Maximum Speed | 15,000 rpm |
| Maximum RCF | 15,596 × g |
| Dimensions (W×D×H) | 230 × 270 × 130 mm |
| Net Weight | 5 kg |
| Display | LCD |
| Speed/RCF Increment | 100 rpm / 100 × g |
| Timer Range | 30 s – 999 min (1 s increment) |
| Noise Level | <60 dB(A) |
| Motor | Brushless DC, Maintenance-Free |
| Safety Compliance | EN 61010-1, EN 61010-2-101, EN 61010-2-020, EN 61326-1, EN 61326-2-6 |
| Regulatory Directives | 2011/65/EU (RoHS), 2012/19/EU (WEEE), 2014/30/EU (EMC), 2014/35/EU (LVD), 98/79/EC (IVDD) |
| Brand | AnTing |
|---|---|
| Origin | Shanghai, China |
| Model | 800B |
| Type | Benchtop Centrifuge |
| Speed Range | Up to 4000 rpm |
| Max RCF | 1430 × g |
| Rotor Capacity | 6 × 20 mL (angle rotor) |
| Power Supply | 220 V, 50 Hz, 40 W |
| Dimensions (D×H) | 245 mm × 210 mm |
| Weight | 4 kg |
| Construction | High-strength engineering plastic housing |
| Safety | Electronic lid lock |
| Application Class | General-purpose low-speed separation |
| Brand | AnTing |
|---|---|
| Origin | Shanghai, China |
| Model | 800C |
| Type | Benchtop Centrifuge |
| Speed Range | Up to 4000 rpm |
| Max RCF | 1430 × g |
| Rotor Capacity | 6 × 15 mL (angle rotor) |
| Timer Range | 0–99 min |
| Power Supply | 220 V, 50 Hz, 180 W |
| Dimensions (L×W×H) | 520 × 375 × 335 mm |
| Weight | 45 kg |
| Construction | Reinforced polymer housing |
| Safety | Electronic door interlock |
| Brand | AnTing |
|---|---|
| Origin | Shanghai, China |
| Model | 800D |
| Type | Benchtop Centrifuge |
| Speed Range | 0–4000 rpm |
| Max RCF | 1430 ×g |
| Rotor Type | Fixed-Angle Rotor |
| Rotor Capacity | 15 mL × 6 |
| Timer Range | 0–99 min |
| Power Supply | 220 V, 50 Hz, 180 W |
| Dimensions (L×W×H) | 520 × 375 × 335 mm |
| Net Weight | 45 kg |
| Construction | Reinforced polymer housing with electronic safety door lock |
| Cooling | Non-refrigerated (ambient-temperature operation) |
| Brand | AnTing |
|---|---|
| Origin | Shanghai, China |
| Model | DL-4000B |
| Type | Benchtop Refrigerated Centrifuge |
| Rotor Configuration | Swing-Bucket (Horizontal) |
| Max Speed | 4000 rpm |
| Max RCF | 3600 × g |
| Max Capacity | 500 mL × 6 |
| Temperature Range | −20 °C to +30 °C |
| Timer Range | 0–99 min |
| Power Supply | 220 V, 50 Hz, 2.5 kW |
| Dimensions (L×W×H) | 710 × 575 × 850 mm |
| Weight | 213 kg |
| Rotor Options | No.1 (500 mL × 6 / 50 mL × 24 / 10 mL × 72), No.2 (6 mL × 210), No.3 (192-well microplate, max 3500 rpm) |
| Brand | AnTing |
|---|---|
| Origin | Shanghai, China |
| Model | DL-4C |
| Type | Benchtop Centrifuge |
| Speed Range | 0–4000 rpm |
| Max RCF | 3776 ×g |
| Dimensions (L×W×H) | 580 mm × 630 mm × 650 mm |
| Weight | 160 kg |
| Power Supply | 220 V, 50 Hz, 750 W |
| Timer Range | 0–99 min |
| Rotor Configuration | Horizontal swing-out rotor |
| Standard Capacity Options | 500 mL × 4, 100 mL × 4, 50 mL × 16, 15 mL × 28, 10 mL × 48, 7 mL × 48, 5 mL × 48, or 192-well microplate support |
| Safety | Electronic door lock |
| Construction | Reinforced polymer housing |
| Brand | AnTing |
|---|---|
| Origin | Shanghai, China |
| Model | DL-5-B |
| Instrument Type | Benchtop Centrifuge |
| Speed Range | Up to 5000 rpm |
| Max RCF | 5000 × g |
| Max Capacity | 250 mL × 4 |
| Timer Range | 0–99 min |
| Power Supply | 220 V, 50 Hz, 2.5 kW |
| Dimensions (L×W×H) | 590 mm × 460 mm × 675 mm |
| Weight | 83 kg |
| Rotor Configuration | Fixed-angle rotor |
| Construction | Reinforced polymer housing with structural steel frame |
| Safety | Electronic lid interlock system |
| Brand | AnTing |
|---|---|
| Origin | Shanghai, China |
| Model | DL-5000B |
| Type | Benchtop Refrigerated Centrifuge |
| Max Speed | 5000 rpm |
| Max RCF | 6000 ×g |
| Max Capacity | 1200 mL × 6 (with No.1 swing rotor) |
| Temperature Range | −20 °C to +30 °C |
| Temp. Accuracy | ±2 °C |
| Timer Range | 0–99 min |
| Noise Level | <70 dB(A) |
| Power Supply | 220 V, 50 Hz, 3 kW |
| Dimensions (L×W×H) | 860 mm × 750 mm × 955 mm |
| Weight | 337 kg |
| Rotor Configuration | Dual swing-out rotors (No.1: 1200 mL × 6 at 4000 rpm |
| No.2 | options include 500 mL × 6 / 50 mL × 24 / 10 mL × 72, all rated up to 5000 rpm) |
| Safety | Electronic door interlock system |
| Construction | Reinforced polymer housing with vibration-damping base |
| Brand | AnTing |
|---|---|
| Origin | Shanghai, China |
| Model | DL-5000B-C |
| Type | Benchtop Refrigerated Centrifuge |
| Max Speed | 5000 rpm |
| Max RCF | ~4000 ×g |
| Max Capacity | 100 mL × 4 |
| Temperature Range | −20 °C to 30 °C |
| Temp. Accuracy | ±2 °C |
| Timer Range | 0–99 min |
| Noise Level | <70 dB(A) |
| Power Supply | 220 V, 50 Hz, 1.5 kW |
| Dimensions (L×W×H) | 500 × 590 × 780 mm |
| Weight | 120 kg |
| Rotor Configurations | Horizontal rotor with air shield (e.g., 100 mL × 4, 250 mL × 4, 15 mL × 16, etc.), Radioimmunoassay-specific rotor (6 mL × 96) |
| Brand | AnTing |
|---|---|
| Origin | Shanghai, China |
| Model | DL-5000B-II |
| Type | Benchtop Refrigerated Centrifuge |
| Max. Speed | 5000 rpm |
| Max. RCF | 5000 × g |
| Max. Capacity | 250 mL × 4 (horizontal rotor) |
| Temperature Range | −20 °C to +30 °C |
| Temp. Accuracy | ±2 °C |
| Timer Range | 0–99 min |
| Power Supply | 220 V, 50 Hz, 1.5 kW |
| Dimensions (L×W×H) | 460 mm × 510 mm × 680 mm |
| Net Weight | 245 kg |
| Rotor Type | Horizontal (swing-out) |
| Construction | Reinforced polymer housing |
| Brand | AnTing |
|---|---|
| Origin | Shanghai, China |
| Model | DL-5200 |
| Type | Benchtop Centrifuge |
| Speed Range | 0–4500 rpm |
| Max RCF | 5000 × g |
| Max Capacity | 4 × 1000 mL (horizontal rotor) |
| Timer Range | 0–99 min |
| Power Supply | 220 V, 50 Hz, 3 kW |
| Dimensions (L×W×H) | 650 × 710 × 835 mm |
| Weight | 250 kg |
| Construction | Reinforced polymer housing with precision-machined rotor chamber |
| Safety | Electronic door interlock system |
| Compliance | Designed to meet IEC 61010-1 safety requirements for laboratory equipment |
| Brand | AnTing |
|---|---|
| Origin | Shanghai, China |
| Model | DL-5C |
| Type | Benchtop Centrifuge |
| Speed Range | 0–5000 rpm |
| Max RCF | 4500 × g |
| Max Capacity | 250 mL × 4 (horizontal rotor) |
| Rotor Configurations | Horizontal rotors for 6×96-well plates (6 mL × 96), 15 mL × 32, 25 mL × 56, 50 mL × 16, 10 mL × 36, 15 mL × 16, 50 mL × 8, 250 mL × 4 |
| Timer Range | 0–99 min |
| Power Supply | 220 V, 50 Hz, 400 W |
| Dimensions (L×W×H) | 660 mm × 460 mm × 415 mm |
| Net Weight | 90 kg |
| Construction | Full stainless-steel housing with reinforced polymer structural components |
| Drive System | Frequency-converter-controlled brushless DC motor |
| Safety | Electronic door interlock, imbalance detection, automatic rotor recognition (via preset rotor profiles) |
| Brand | AnTing |
|---|---|
| Origin | Shanghai, China |
| Model | DL-6000B |
| Type | Benchtop Refrigerated Centrifuge |
| Max. Speed | 6000 rpm |
| Max. RCF | 7500 × g |
| Max. Capacity | 4 × 500 mL (horizontal rotor) |
| Temperature Range | −20 °C to +30 °C |
| Temp. Accuracy | ±2 °C |
| Timer Range | 0–99 min |
| Power Supply | 220 V, 50 Hz, 2.5 kW |
| Dimensions (L×W×H) | 710 mm × 575 mm × 850 mm |
| Weight | 213 kg |
| Rotor Type | Horizontal swing-out |
| Construction | Reinforced polymer housing |
| Brand | AnTing |
|---|---|
| Origin | Shanghai, China |
| Model | DL-6000C |
| Type | Benchtop Refrigerated Centrifuge |
| Max Speed | 6000 rpm |
| Max RCF | 7500 ×g |
| Max Capacity | 4 × 500 mL (horizontal rotor) |
| Temperature Range | −20 °C to +30 °C |
| Temp. Accuracy | ±2 °C |
| Timer Range | 0–99 min |
| Noise Level | <70 dB(A) |
| Dimensions (L×W×H) | 740 × 575 × 840 mm |
| Weight | 220 kg |
| Power Supply | 220 V, 50 Hz, 2.5 kW |
| Rotor Configuration | Horizontal swing-out rotor with air shield |
| Construction | Full stainless-steel body with high-strength polymer housing |
| Drive System | Frequency-controlled AC motor |
| Safety | Electronic door lock, automatic rotor recognition (optional), imbalance detection |
| Brand | AnTing Feige |
|---|---|
| Origin | Shanghai, China |
| Model | 800B |
| Instrument Type | Benchtop Centrifuge |
| Speed Range | 0–4000 rpm |
| Max RCF | 1430 ×g |
| Capacity | 6 × 20 mL (angle rotor) |
| Power Supply | 220 V, 50 Hz, 40 W |
| Dimensions (D×H) | 245 × 210 mm |
| Weight | 5 kg |
| Construction | High-strength polymer housing |
| Compliance | Designed for routine clinical and biochemical laboratory use per ISO 13485-aligned manufacturing practices |
| Brand | AnTing Feige |
|---|---|
| Origin | Shanghai, China |
| Instrument Type | Floor-standing centrifuge |
| Max Speed | 16,000 rpm |
| Max RCF | 20,000 × g |
| Max Capacity | 12 × 10 mL |
| Temperature Range | −5 °C to +30 °C |
| Temp. Accuracy | ±2 °C |
| Timer Range | 0–99 min |
| Speed Accuracy | < ±50 rpm |
| Noise Level | < 72 dB(A) |
| Dimensions (L×W×H) | 500 × 590 × 780 mm |
| Weight | 80 kg |
| Power Supply | 220 V, 50 Hz |
| Total Power | 1.5 kW |
| Rotor Type | Fixed-angle |
| Application Class | Biomolecular separation |
| Cooling System | Imported refrigeration unit |
| Drive System | Inverter-controlled brushless motor |
| Chamber Material | ASTM A240 316 stainless steel |
| Safety | Electronic lid lock, auto-balancing suspension, fail-safe rotor recognition |
| Brand | AnTing FeiGe |
|---|---|
| Origin | Shanghai, China |
| Model | LXJ-IIB |
| Type | Benchtop Centrifuge |
| Max Speed | 5000 rpm |
| Max RCF | 6000 ×g |
| Max Capacity | 500 mL × 6 (swinging-bucket rotor) |
| Rotor Configurations | 500 mL × 6 / 50 mL × 24 / 10 mL × 72 (at 6000 rpm) |
| Timer Range | 0–99 min |
| Power Supply | 220 V, 50 Hz, 400 W |
| Dimensions (L×W×H) | 610 × 650 × 795 mm |
| Weight | 100 kg |
| Control System | Microprocessor-based digital control with auto-balance algorithm |
| Safety | Electromagnetic door lock, rotor recognition logic, overspeed/overheat/imbalanced load protection |
