| Brand | LuoXiangYi / BIORIDGE |
|---|---|
| Origin | Shanghai, China |
| Model | DDL-5M |
| Centrifuge Type | Benchtop Refrigerated Centrifuge |
| Maximum Speed | 5000 rpm |
| Maximum RCF | 3780 × g |
| Maximum Capacity | 4 × 750 mL |
| Temperature Range | −20 °C to +40 °C |
| Temperature Accuracy | ±1 °C |
| Speed Accuracy | ±50 rpm |
| Timer Range | 1–99 min |
| Noise Level | <65 dB(A) |
| Dimensions (L×W×H) | 650 × 710 × 1100 mm |
| Net Weight | 170 kg |
| Refrigerant | R404a |
| Power Supply | AC 220 V, 50 Hz, 20 A |
| Brand | LUXIANGYI / BIORIDGE |
|---|---|
| Origin | Shanghai, China |
| Model | CSC-12S |
| Instrument Type | Benchtop Centrifuge |
| Speed Range | 10,000 rpm |
| Max RCF | 21,250 × g |
| Sample Capacity | Standard 1″ and 1.5″ core plugs |
| Temperature Range | −20 °C to +40 °C |
| Temp. Accuracy | ±1 °C |
| Speed Accuracy | ±50 rpm |
| Ramp/Brake Profiles | 10 programmable curves |
| Noise Level | <65 dB(A) |
| Power Supply | AC 220 V, 50 Hz |
| Power Consumption | 5 kW |
| Dimensions (L×W×H) | 710 mm × 840 mm × 1200 mm |
| Net Weight | 290 kg |
| Refrigerant | R404a (non-ozone-depleting) |
| Compliance | FDA-registered, GMP-compliant sealing (food-grade silicone monolithic gasket) |
| Brand | LUXIANGYI / BIORIDGE |
|---|---|
| Origin | Shanghai, China |
| Model | DL-6M |
| Instrument Type | Benchtop Refrigerated Centrifuge |
| Rotor Configuration | Horizontal (Swinging-Bucket) |
| Maximum Capacity | 6 × 1200 mL |
| Max Speed | 6,000 rpm |
| Max RCF | 6,680 × g |
| Temperature Range | −20 °C to +40 °C |
| Temp. Control Accuracy | ±1 °C |
| Speed Accuracy | ±50 rpm |
| Time Setting | 1 min – 99 h 59 min |
| Noise Level | <65 dB(A) |
| Power Supply | AC 220 V, 50 Hz, 30 A |
| Dimensions (L×W×H) | 710 mm × 840 mm × 1200 mm |
| Net Weight | 320 kg |
| Refrigerant | R404a (non-ozone-depleting) |
| Motor | High-torque AC frequency-controlled motor |
| Safety Features | Electronic door lock, overspeed/overtemperature/unbalance detection, automatic fault alarm |
| Acceleration/Deceleration Profiles | 10 programmable ramp curves |
| Brand | LUXIANGYI / BIORIDGE |
|---|---|
| Origin | Shanghai, China |
| Model | DL-8M |
| Instrument Type | Benchtop Refrigerated Centrifuge |
| Speed Range | Up to 8,000 rpm |
| Max RCF | 11,260 × g |
| Max Capacity | 6 × 2,400 mL (14,400 mL total) |
| Temperature Range | –20 °C to +40 °C |
| Temp. Accuracy | ±1 °C |
| Speed Accuracy | ±50 rpm |
| Timer Range | 1 min – 99 h 59 min |
| Refrigerant | R404a (non-ozone-depleting) |
| Noise Level | <70 dB(A) |
| Power Supply | AC 380 V, 50 Hz, 40 A |
| Dimensions (L×W×H) | 900 mm × 1000 mm × 1300 mm |
| Compliance | CE-marked per IEC 61010-1 |
| Brand | LUXIANGYI / BIORIDGE |
|---|---|
| Origin | Shanghai, China |
| Model | H14.5M |
| Instrument Type | Benchtop Centrifuge |
| Speed Range | 200–14,500 rpm |
| Max RCF | 14,000 × g |
| Max Capacity | 12 × 1.5 mL or 12 × 2.2 mL (angular rotor) |
| Rotor Options | Aluminum angular rotor (sealed, autoclavable), 0.2 mL 8-tube strip rotor (4 × 8 positions, max 6,000 rpm / 2,140 × g) |
| Speed Accuracy | ±30 rpm |
| Timer Range | 20 s – 99 min |
| Acceleration/Deceleration Time | ≤12 s (0 → max / max → 0) |
| Noise Level | <50 dB(A) |
| Dimensions (W×D×H) | 230 × 270 × 155 mm |
| Net Weight | 4.8 kg |
| Power Supply | AC 220 V, 50 Hz |
| Power Consumption | 100 W |
| Temperature Rise | ≤10 °C after 30 min at maximum speed |
| Safety Certification | CE compliant |
| Rotor Material | Anodized aluminum with hermetic sealing |
| Brand | LUXIANGYI / BIORIDGE |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | TD-4K |
| Instrument Type | Palm-Sized Centrifuge |
| Speed Range | Up to 4,000 rpm |
| Max RCF | 900 × g |
| Capacity | 6 × (1.5 mL / 0.5 mL / 0.2 mL) tubes |
| Noise Level | <48 dB(A) |
| Dimensions (L×W×H) | 189 mm × 161 mm × 122 mm |
| Power Supply | AC 220 V, 50 Hz |
| Net Weight | ~1.0 kg |
| Rotor Type | Fixed-angle rotor |
| Target Applications | Cellular and bacterial pelleting, microsample clarification, PCR tube spinning, quick spin-down of column-based kits |
| Brand | LUXIANGYI / BIORIDGE |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | TD-SZ |
| Instrument Type | Benchtop Centrifuge |
| Speed Range | 0–4000 rpm |
| Max RCF | 2200 × g |
| Max Capacity | 2 × 500 mL or 4 × 250 mL |
| Timer Range | 1 s – 99 min 59 s (or 1–99 min in coarse mode) |
| Power Consumption | 150 W |
| Dimensions (L×W×H) | 330 mm × 420 mm × 280 mm |
| Weight | 14 kg |
| Motor | Brushless DC |
| Sealing | Food-grade silicone monolithic gasket |
| Certifications | FDA registered, GMP-compliant |
| Optional Accessories | Portable power station (2 h runtime), telescopic handle carry case |
| Brand | LUXIANGYI / BIORIDGE |
|---|---|
| Origin | Shanghai, China |
| Model | TD5A |
| Centrifuge Type | Benchtop Low-Speed Centrifuge |
| Max Speed | 5000 rpm |
| Max RCF | 4390 × g |
| Max Capacity | 36 × 15 mL |
| Dimensions (L×W×H) | 460 mm × 540 mm × 340 mm |
| Noise Level | <65 dB(A) |
| Power Supply | AC 220 V, 50 Hz |
| Power Consumption | 500 W |
| Weight | 28 kg |
| Speed Accuracy | ±30 rpm |
| Timer Range | 1 s – 99 min 59 s |
| Rotor Compatibility | 5 standard rotor types (horizontal, swing-out, fixed-angle, microplate, and multi-bucket configurations) |
| Brand | LuXiangYi / BIORIDGE |
|---|---|
| Origin | Shanghai, China |
| Model | TG1650-WS |
| Instrument Type | Benchtop Centrifuge |
| Speed Range | 300–16,500 rpm |
| Max RCF | 23,669 × g |
| Max Capacity | 4 × 100 mL |
| Dimensions (L×W×H) | 330 × 420 × 280 mm |
| Noise Level | <65 dB(A) |
| Power Supply | AC 220 V, 50 Hz, 10 A |
| Net Weight | 20 kg |
| Rotor Compatibility | Horizontal swing-out rotors, fixed-angle rotors, PCR strip rotors, microplate carriers |
| Speed Accuracy | ±30 rpm |
| Timer Range | 1–99 min |
| Acceleration/Deceleration Profiles | 9 programmable ramp curves |
| Safety Features | Electronic lid lock, overspeed protection, automatic fault alarm, rotor imbalance detection |
| Brand | LUXIANGYI / BIORIDGE |
|---|---|
| Origin | Shanghai, China |
| Model | TGL-18MS |
| Type | Benchtop Refrigerated Centrifuge |
| Max Speed | 18,000 rpm |
| Max RCF | 23,755 × g |
| Max Capacity | 4 × 100 mL (horizontal rotor) |
| Temperature Range | −20 °C to +40 °C |
| Temp. Accuracy | ±1 °C |
| Speed Accuracy | ±30 rpm |
| Timer Range | 1 min–9 h 59 min (or 1 min–99 min) |
| Noise Level | <65 dB(A) |
| Dimensions (L×W×H) | 600 × 470 × 330 mm |
| Net Weight | 50 kg |
| Refrigerant | R134a |
| Power Supply | AC 220 V, 50 Hz, 15 A |
| Brand | Other Brands |
|---|---|
| Origin | Imported |
| Manufacturer Type | General Distributor |
| Model | LXJ-Capacity |
| Price | USD 14,000 (approx.) |
| Compliance | MIL-STD-810F, MIL-STD-883C, GJB150, GJB360, GB/T 2423, IEC 60068-2-27 |
| Max Load Capacity | 35–200 kg |
| Acceleration Range | 30–400,000 g (0.3–3920 kN/m² equivalent) |
| Test Axes | X, Y, Z orthogonal directions |
| Specimen Height Limit | 200–300 mm |
| Installation Radius | 200–1000 mm |
| Power Supply | AC 380 V, 1.5–6.5 kVA |
| Continuous Operation Time | 30–60 min |
| Control System | Industrial PC with Real-Time Data Acquisition |
| Slip Ring Configuration | Up to 15 channels, 500 V / 5 A |
| Dimensions (L×W×H) | 924×910×1242 mm to 1953×470×993 mm |
| Weight | 1000–2300 kg |
| Brand | LY |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Instrument Type | Benchtop Centrifuge |
| Speed Range | Up to 7,000 rpm ±5% |
| Max RCF | 3,286 × g |
| Rotor Capacity | Dual-configuration rotor — 12 × (0.2/0.5/1.5/2.0 mL tubes) or 4 × 8-position PCR strip carriers (0.2 mL) + 12 × (0.5/1.0 mL tubes) |
| Dimensions (W×D×H) | 185 × 180 × 135 mm |
| Noise Level | <47 dB(A) at max speed |
| Acceleration/Deceleration Time | <12 s / <15 s |
| Input Power | 25 W |
| Voltage | AC 100–240 V / DC 24 V |
| Operating Environment | 5–40 °C, ≤80% RH |
| Display | Fixed-speed LCD |
| Compliance | Designed for non-medical laboratory use per IEC 61010-1 safety requirements |
| Brand | MKN |
|---|---|
| Model | 90-2 |
| Max Speed | 0–4000 rpm |
| Relative Centrifugal Force (RCF) | 2325 × g |
| Capacity | 12 × 20 mL (or 12 × 15 mL) |
| Timer Range | 0–60 min |
| Power | 135 W |
| Noise Level | ≤60 dB(A) |
| Supply Voltage | AC 220 V, 50 Hz, 2 A |
| Rotor Material | Aluminum Alloy |
| Drive System | Dedicated Centrifuge Motor |
| Control Type | Stepless Speed Adjustment + Mechanical Timer |
| Display | Digital RPM + Analog Time Scale |
| Safety Features | Balance Protection, Dual Fuse System, Safety Interlock Switch |
| Compliance | Designed for GLP-compliant laboratories |
| Brand | OHAUS |
|---|---|
| Origin | Shanghai, China |
| Model | FC2516 w/R08 |
| Centrifuge Type | Benchtop High-Speed Centrifuge |
| Maximum Speed | 300–16,500 rpm |
| Maximum RCF | 19,080 × g |
| Maximum Capacity | 48 × 1.5/2.0 mL |
| Rotor Type | Fixed-Angle, Airtight (R08, Part No. 30694908) |
| Dimensions (W×D×H) | 245 mm × 280 mm × 380 mm |
| Motor | Brushless DC |
| Safety Features | Imbalance Detection, Automatic Rotor Recognition, Lid Interlock, Airtight Rotor Sealing (Dual-Silicone Gasket), Auto-Open Lid Post-Run |
| Compliance | Designed for GLP-compliant workflows |
| Software Capability | 9-Program Memory, 3-Step Sequential Protocol, Real-Time Speed Adjustment Without Stop |
| Brand | Ortoalresa |
|---|---|
| Origin | Spain |
| Model | Biocen 22 |
| Instrument Type | Benchtop Centrifuge |
| Speed Range | Up to 15,000 rpm |
| Max RCF | 21,885 × g |
| Capacity | 24 × 2 mL or 12 × 5 mL |
| Dimensions (W×D×H) | 276 × 390 × 272 mm |
| Noise Level | <60 dB(A) |
| Compliance | EN 61010-1, EN 61010-2-020, EN 61326-1, EN 61326-2-6, EU Directives 2011/65/EU, 2012/19/EU, 2014/30/EU, 2014/35/EU, 98/79/EC |
| Brand | Ortoalresa |
|---|---|
| Origin | Spain |
| Model | Biocen 22 R |
| Type | Benchtop Refrigerated Centrifuge |
| Speed Range | 100–18,100 rpm |
| Max RCF | 31,865 × g |
| Max Capacity | 8 × 15 mL |
| Temperature Range | –20 °C to +40 °C (1 °C increments) |
| Cooling Medium | R-449A/HFO (CFC-free) |
| Dimensions (W×D×H) | 276 × 640 × 272 mm |
| Noise Level | <60 dB(A) |
| Compliance | EN 61010-1, EN 61010-2-020, EN 61326-1, EN 61326-2-6, EU Directives 2011/65/EU, 2012/19/EU, 2014/30/EU, 2014/35/EU, 98/79/EC |
| Safety Features | Automatic dual-lock lid, emergency lid release, imbalance detection, rotor auto-recognition, over-speed protection, stainless steel chamber, sterilizable rotors & adapters |
| Brand | Ortoalresa |
|---|---|
| Origin | Spain |
| Centrifuge Type | Benchtop |
| Maximum Capacity | 4 × 400 mL |
| Maximum Speed | 14,300 rpm |
| Maximum RCF | 21,948 × g |
| Dimensions (W × D × H) | 490 × 620 × 390 mm |
| Display | TFT Color Touchscreen |
| Acceleration/Deceleration Control | Progressive (PCBS), up to 175 selectable ramps |
| Unbalance Detection System (ULS) | Real-time bucket position identification |
| Programmable Protocols | 40 user-defined methods with password protection |
| Noise Level | <60 dB(A) |
| Motor | Brushless induction motor |
| Safety Compliance | EN 61010-1, EN 61010-2-020, EN 61326-1, EN 61326-2-6 |
| Regulatory Conformance | 2011/65/EU (RoHS), 2012/19/EU (WEEE), 2014/30/EU (EMC), 2014/35/EU (LVD), 98/79/EC (IVDR) |
| Brand | Ortoalresa |
|---|---|
| Origin | Spain |
| Instrument Type | Benchtop Centrifuge |
| Cooling Function | Refrigerated (−20 °C to 40 °C) |
| Maximum Capacity | 4 × 400 mL |
| Maximum Speed | 14,300 rpm |
| Maximum RCF | 21,948 × g |
| Dimensions (W × D × H) | 670 × 770 × 390 mm |
| Noise Level | <60 dB(A) |
| Rotor Type | Swinging-bucket (standard), with optional angle and microplate rotors |
| Safety Compliance | EN 61010-1, EN 61010-2-020, EN 61326-1, EN 61326-2-6 |
| Refrigerant | R-449A (HFO-based, zero ODP, low GWP) |
| Programmable Protocols | 40 user-defined methods with password protection |
| Control Interface | TFT color touchscreen (visible from ≥3 m) |
| Brand | Ortoalresa |
|---|---|
| Origin | Spain |
| Instrument Type | Benchtop Centrifuge |
| Maximum Speed | 2500 rpm |
| Maximum RCF | 866 × g |
| Maximum Capacity | 12 × 6 mL |
| Rotor Configuration | Horizontal Swing-Out Rotor |
| Separation Target | Large Organelles / Viruses |
| Dimensions (W × D × H) | 410 mm × 530 mm × 320 mm |
| Noise Level | < 60 dB(A) |
| Compliance | EN 61010-1, EN 61010-2-101, EN 61010-2-020, EN 61326-1, EN 61326-2-6, Directive 2011/65/EU, 2012/19/EU, 2014/30/EU, 2014/35/EU |
| Brand | Ortoalresa |
|---|---|
| Origin | Spain |
| Type | Benchtop Centrifuge |
| Maximum Speed | 16,500 rpm |
| Maximum RCF | 26,480 × g |
| Maximum Capacity | 4 × 100 mL |
| Dimensions (W×D×H) | 410 × 520 × 320 mm |
| Noise Level | <60 dB(A) |
| Motor | Brushless Induction Motor |
| Safety Compliance | EN 61010-1, EN 61010-2-101, EN 61326-1, EN 61326-2-6 |
| Regulatory Directives | 2011/65/EU (RoHS), 2012/19/EU (WEEE), 2014/30/EU (EMC), 2014/35/EU (LVD), 98/79/EC (IVDD) |
| Brand | Ortoalresa |
|---|---|
| Origin | Spain |
| Instrument Type | Benchtop Centrifuge |
| Cooling Function | Refrigerated (4 °C operation) |
| Rotor Configuration | Fixed-angle and swing-out options |
| Maximum Capacity | 4 × 100 mL |
| Maximum Speed | 16,500 rpm |
| Maximum RCF | 26,480 × g |
| Dimensions (W×D×H) | 590 × 620 × 320 mm |
| Noise Level | <60 dB(A) |
| Power Supply | 220–230 V / 50 Hz (700 W) or 110–120 V / 60 Hz (800 W) |
| Compliance | EN 61010-1, EN 61010-2-101, EN 61010-2-020, EN 61326-1, EN 61326-2-6 |
| Safety Features | Automatic lid locking, imbalance detection, overspeed protection, stainless steel chamber, autoclavable rotors & adapters |
| Brand | Ortoalresa |
|---|---|
| Origin | Spain |
| Model | Digtor 22 C |
| Instrument Type | Benchtop Centrifuge |
| Max Speed | 3000 rpm |
| Max RCF | 2425 × g |
| Max Capacity | 4 × 100 mL |
| Dimensions (W×D×H) | 540 × 650 × 400 mm |
| Noise Level | <60 dB(A) |
| Heating Range | +5°C to 80°C (adjustable in 1°C/1°F steps) |
| Compliance | ASTM D91, D96, D893, D1796, D2273, D2709, D2711, D4007, D5546 |
| Safety Standards | EN 61010-1, EN 61010-2-020, EN 61326-1, EN 61326-2-6, EN 61010-2-010 |
| EU Directives | 2011/65/EU (RoHS), 2012/19/EU (WEEE), 2014/30/EU (EMC), 2014/35/EU (LVD), 98/79/EC (IVDD) |
| Brand | Ortoalresa |
|---|---|
| Origin | Spain |
| Model | Digtor 22 C-8 |
| Instrument Type | Benchtop Centrifuge |
| Max Speed | 3000 rpm |
| Max RCF | 2425 × g |
| Max Capacity | 4 × 100 mL (8" tubes) |
| Dimensions (W×D×H) | 540 × 650 × 400 mm |
| Heating Range | +5°C to 80°C (programmable in 1°C/1°F increments) |
| Compliance | ASTM D91, D96, D893, D1796, D2273, D2709, D2711, D4007, D5546 |
| Safety Standards | EN 61010-1, EN 61010-2-020, EN 61326-1, EN 61326-2-6, EN 61010-2-010 |
| EU Directives | 2011/65/EU (RoHS), 2012/19/EU (WEEE), 2014/30/EU (EMC), 2014/35/EU (LVD), 98/79/EC (IVDD) |
| Brand | Ortoalresa |
|---|---|
| Origin | Spain |
| Model | Digtor 22 Col |
| Type | Benchtop Centrifuge |
| Maximum Speed | 3000 rpm |
| Maximum RCF | 1801 × g |
| Maximum Capacity | 4 × 60 mL |
| Dimensions (W×D×H) | 540 × 650 × 400 mm |
| Noise Level | <60 dB(A) |
| Motor | Brushless Induction Motor |
| Compliance | EN 61010-1, EN 61010-2-020, EN 61326-1, EN 61326-2-6, EN 61010-2-010, EU Directives 2011/65/EU, 2012/19/EU, 2014/30/EU, 2014/35/EU, 98/79/EC |
| Brand | Ortoalresa |
|---|---|
| Origin | Spain |
| Model | Digtor 22 CU |
| Type | Benchtop Centrifuge |
| Max Speed | 3,000 rpm |
| Max RCF | 2,425 × g |
| Max Capacity | 4 × 100 mL |
| Dimensions (W×D×H) | 540 × 650 × 400 mm |
| Noise Level | <60 dB(A) |
| Compliance | EN 61010-1, EN 61010-2-020, EN 61326-1, EN 61326-2-6, Directive 2014/35/EU, 2014/30/EU, 98/79/EC |
| Safety Features | Automatic lid locking, ULS imbalance detection, GRS (Gas Release System) pre-installed, stainless steel chamber, autoclavable rotors & adapters |
| Brand | Ortoalresa |
|---|---|
| Origin | Spain |
| Model | Digtor 22 |
| Instrument Type | Benchtop Centrifuge |
| Speed Range | Up to 14,300 rpm |
| Max RCF | 21,948 × g |
| Max Capacity | 4 × 750 mL |
| Dimensions (W×D×H) | 540 × 650 × 390 mm |
| Noise Level | <60 dB(A) |
| Motor | Brushless Induction Motor |
| Control Interface | Color TFT Touchscreen (visible from ≥3 m) |
| Programmable Memories | 40 (password-protected) |
| Acceleration/Deceleration Ramps | 175 selectable profiles (PCBS) |
| Unbalance Detection System (ULS) | Real-time rotor position identification |
| Safety Compliance | EN 61010-1, EN 61010-2-020, EN 61326-1, EN 61326-2-6 |
| EU Directives | 2011/65/EU (RoHS), 2012/19/EU (WEEE), 2014/30/EU (EMC), 2014/35/EU (LVD), 98/79/EC (IVDD) |
| Brand | Ortoalresa |
|---|---|
| Origin | Spain |
| Model | Dilitcen 22 |
| Type | Benchtop Centrifuge |
| Max Capacity | 4 × 1000 mL |
| Max Speed | 14,300 rpm |
| Max RCF | 21,948 × g |
| Dimensions (W×D×H) | 540 × 650 × 390 mm |
| Noise Level | <60 dB(A) |
| Power Supply | 220–230 V / 50–60 Hz or 110–120 V / 50–60 Hz |
| Power Consumption | 1020 W |
| Compliance | EN 61010-1, EN 61010-2-020, EN 61326-1, EN 61326-2-6, EU Directives 2011/65/EU, 2012/19/EU, 2014/30/EU, 2014/35/EU, 98/79/EC |
| Brand | Ortoalresa |
|---|---|
| Origin | Spain |
| Model | Lacter 21 |
| Instrument Type | Benchtop Centrifuge |
| Speed Range | 0–1,200 rpm |
| Relative Centrifugal Force (RCF) | up to 224 × g |
| Maximum Capacity | 12 butyrometers |
| Heating Capability | Up to 80 °C |
| Dimensions (W×D×H) | 365 × 300 × 450 mm |
| Net Weight | 23 kg |
| Power Supply | 220–230 V / 50 Hz or 110–120 V / 50/60 Hz |
| Power Consumption | 500 W (heating mode), 480 W (standard mode) |
| Safety Compliance | EN 61010-1, EN 61010-2-020, EN 61326-1, EN 61326-2-6, EN 61010-2-010 |
| Regulatory Directives | 2011/65/EU (RoHS), 2012/19/EU (WEEE), 2014/30/EU (EMC), 2014/35/EU (LVD), 98/79/EC (IVDD) |
| Brand | Ortoalresa |
|---|---|
| Origin | Spain |
| Instrument Type | Floor-standing centrifuge |
| Cooling Function | Refrigerated (−20 °C to +40 °C) |
| Maximum Speed | 14,300 rpm |
| Maximum RCF | 21,948 ×g |
| Maximum Capacity | 4 × 750 mL |
| Dimensions (W×D×H) | 540 × 650 × 930 mm |
| Noise Level | <60 dB(A) |
| Drive System | Brushless induction motor |
| Control Interface | TFT color touchscreen with real-time RPM/RCF display |
| Programmability | 40 password-protected protocols |
| Safety Compliance | EN 61010-1, EN 61010-2-020, EN 61326-1, EN 61326-2-6 |
| Refrigerant | R-449A (HFO-based, zero ODP, low GWP) |
| Regulatory Conformance | 2011/65/EU (RoHS), 2012/19/EU (WEEE), 2014/30/EU (EMC), 2014/35/EU (LVD), 98/79/EC (IVDR), (EC) No 1005/2009, (EU) No 517/2014 |
| Brand | Ortoalresa |
|---|---|
| Origin | Spain |
| Model | Minicen |
| Instrument Type | Palm-Sized Centrifuge |
| Max Speed | 15,000 rpm |
| Max RCF | 15,596 × g |
| Max Capacity | 12 × 2 mL |
| Rotor Configuration | Fixed-angle rotor (12-position, for 1.5–2.0 mL tubes) |
| Adapters Available | For 0.2–0.4 mL and 0.5–0.6 mL microtubes |
| Dimensions (W×D×H) | 260 × 230 × 130 mm |
| Net Weight | 4 kg |
| Power Supply | 230 V / 110 V, 50–60 Hz |
| Power Consumption | 180 W |
| Noise Level | <60 dB(A) |
| Timer Range | 30 s – 999 min (1 s resolution) |
| Acceleration/Deceleration Control | Programmable stepwise (100 rpm / 100 × g increments) |
| Safety Compliance | EN 61010-1, EN 61010-2-020, EN 61326-1, EN 61326-2-6 |
| Regulatory Directives | 2011/65/EU (RoHS), 2012/19/EU (WEEE), 2014/30/EU (EMC), 2014/35/EU (LVD), 98/79/EC (IVDD) |