Add to compare
BrandJBS
OriginJiangsu, China
Manufacturer TypeDirect Manufacturer
Instrument TypePrecision Drying Oven
Temperature RangeRT+10°C to 300°C
Temperature Uniformity±0.5°C
External Dimensions420 × 420 × 620 mm
Internal Chamber Dimensions350 × 350 × 350 mm
Chamber MaterialMirror-Finish Stainless Steel (AISI 304)
Heating MethodForced-Air Convection with Low-Noise Centrifugal Blower
Control SystemMicroprocessor-Based Digital PID Controller
Temperature Resolution0.1°C
Timer Range0–9999 minutes
Power Supply220 V AC, 50 Hz
Safety FeaturesOver-Temperature Cut-Off, Sensor Fault Detection, Leakage Current Protection
Added to wishlistRemoved from wishlist 0
Add to compare
BrandJBS
OriginJiangsu, China
Manufacturer TypeOEM/ODM Producer
Product CategoryDomestic
ModelHPC201
Instrument TypeOnline Fixed-Mount Analyzer
Measurement PrincipleNon-Dispersive Infrared (NDIR) for CO
Maximum Permissible Error±5% of reading
Zero Drift±3% FS/8h
Span Drift±3% FS/8h
Repeatability≤±2% FS
Measurement RangeHC: 0–10,000 ppm (v/v)
CO0–10% (v/v)
AccuracyHC: ±12 ppm or ±5% (whichever greater)
CO±0.06% or ±5% (whichever greater)
ResolutionHC: 1 ppm
CO0.01%
Response Time (t₉₅)≤10 s
Warm-up Time8 min (3 min emergency mode)
Operating Environment–5°C to +50°C, RH ≤90% non-condensing
Power SupplyAC 100–240 V, 50/60 Hz or DC 12 V (with optional inverter)
Power Consumption40 VA
Dimensions420 × 310 × 170 mm (L×W×H)
Weight~9 kg
DisplayHigh-brightness digital LED
Output InterfacesBuilt-in thermal printer
Auto FunctionsAuto-zero calibration
Measurement ModesFree idle and dual-idle testing per GB 18285–2018 and ISO 3930
Added to wishlistRemoved from wishlist 0
Add to compare
BrandJBS
OriginJiangsu, China
Manufacturer TypeManufacturer
Product CategoryDomestic
ModelGGC-W
Instrument TypeInversion Shaker
Timer Range0–999 h
Oscillation Speed0–90 rpm
Temperature Control RangeAmbient to 65 °C
Platform Quantity1
Sample Capacity Options4, 6, 8, 10, or 12 positions
Compatible Vessels2 L glass bottles, PE bottles, and EPA/standard leaching extraction containers
Construction MaterialStainless steel with anti-corrosive coating or mirror-finish stainless steel
Power Supply220 V, 50 Hz
Temperature Accuracy±0.5 °C
Safety FeaturesFull 360° inversion enclosure, lid-actuated power cutoff, and overload protection
Added to wishlistRemoved from wishlist 0
Add to compare
BrandJBS
OriginJiangsu, China
Manufacturer TypeDirect Manufacturer
Instrument TypeBenchtop Laboratory Analyzer
PrincipleCold Vapor Atomic Fluorescence Spectrometry (CVAFS)
Detection Limit≤0.003 µg/L
Repeatability (RSD)≤5%
Linearity Error±5%
Zero Drift<0.2 mV
Measurement Range0.01–100 µg/L
Noise Level<0.1 mV
Correlation Coefficient (Calibration Curve)≥0.996
Operating Temperature5–35 °C
Relative Humidity≤80%
Environmental RequirementsLow-vibration, low-EMI, mercury-free ambient, well-ventilated location with external exhaust capability