Chromatography Accessories
Filter
Showing 31–60 of 398 results
| Brand | Agilent Technologies |
|---|---|
| Origin | Germany |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | 1260 Infinity III ELSD |
| Detection Principle | Evaporative Light Scattering Detection |
| Compatible Systems | Agilent 1260 Infinity III LC, Other HPLC/UHPLC Platforms via Analog/Digital I/O |
| Operating Temperature Range | Up to 120 °C |
| Carrier Gas | Nitrogen or Compressed Air |
| Detection Sensitivity | Sub-nanogram (ng) Level for Non-Volatile and Semi-Volatile Analytes |
| Baseline Stability | Minimal Drift (<0.5 mV/h after equilibration) |
| Data Acquisition Rate | Up to 100 Hz |
| Reproducibility | RSD < 2% (n = 6, repeated injections) |
| Solvent Compatibility | Fully compatible with DMSO, THF, DMF, chlorinated solvents, and high-boiling-point mobile phases |
| Regulatory Compliance | Designed for GLP/GMP environments |
| Brand | Agilent Technologies |
|---|---|
| Origin | Germany |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported |
| Model | 1260 Infinity III FLD |
| Detection Principle | Dual-wavelength Programmable Fluorescence Detection |
| Compatible Systems | Agilent InfinityLab LC Systems & Third-party HPLC Platforms |
| Detection Limit | Raman S/N > 3000 (measured against dark signal noise reference) |
| Data Acquisition Rate | Up to 74 Hz |
| Detector Type | Fluorescence Detector (FD) |
| Flow Cell Interface | Cartridge-style flow cell with auto-identification |
| Regulatory Compliance Support | GLP-compliant parameter logging, audit-ready metadata capture |
| Brand | Agilent Technologies |
|---|---|
| Origin | Germany |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | 1260 Infinity III Fluorescence Detector with Full-Spectrum Acquisition |
| Instrument Type | Fluorescence Detector (FD) |
| Detection Limit | Raman Signal-to-Noise Ratio > 3000 (measured against dark signal noise reference) |
| Data Acquisition Rate | Up to 148 Hz |
| Compatibility | Fully compatible with Agilent InfinityLab LC systems and third-party HPLC platforms |
| Flow Cell | Bio-inert, optimized for biomolecular applications |
| Light Source | Long-life pulsed xenon lamp (> 4000 h), integrated lamp reference system |
| Optical Design | Simplified optical path for superior baseline stability |
| Spectral Capability | Real-time full-spectrum acquisition synchronized with chromatographic elution |
| Brand | Agilent Technologies |
|---|---|
| Origin | Germany |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | 1260 Infinity III MCT |
| Temperature Control | Peltier-based cooling and heating |
| Temperature Range | −10 °C below ambient to +85 °C |
| Maximum Pressure Rating | 800 bar |
| Column Capacity | Up to four 30 cm columns |
| Dual Independent Temperature Zones | Yes |
| Column Identification | RFID-enabled, supports type, parameters, and injection count logging |
| Door Orientation | 90° or 180° configurable |
| Biocompatible Option | Available with inert heat exchanger and valve head |
| Solvent Preheating | Integrated InfinityLab Quick Connect thermal exchanger for reproducible pre-column solvent heating |
| Brand | Agilent Technologies |
|---|---|
| Origin | Germany |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | 1260 Infinity III High-Sensitivity Diode Array Detector (HS) |
| Detection Principle | UV-Vis Absorption Spectrophotometry via Fixed-Slit DAD Architecture |
| Noise Level | < ±3 µAU (typical baseline noise, 1 s bandwidth, 254 nm, 10 mm pathlength cell) |
| Signal Channels | Up to 8 simultaneous wavelength-specific absorbance signals |
| Data Acquisition Rate | Up to 120 Hz (full-spectrum acquisition) |
| Flow Cell | Agilent Max-Light Cartridge Flow Cell with Optical Waveguide, 10 mm pathlength (standard), 60 mm pathlength option available (< ±0.6 µAU/cm noise) |
| Compliance | Designed for GLP/GMP environments |
| Brand | Agilent Technologies |
|---|---|
| Origin | Germany |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | 1260 Infinity III Hybrid Multisampler |
| Instrument Type | HPLC Autosampler |
| Maximum Sample Capacity | 6144 |
| Brand | Agilent Technologies |
|---|---|
| Origin | Germany |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported Instrument |
| Model | 1260 Infinity III Manual Injector |
| Instrument Type | HPLC Manual Injector |
| Maximum Operating Pressure | 600 bar |
| Footprint Compatibility | Designed to match all 1260 Infinity series modules |
| Column Mounting Option | Optional column holder integrated into baseplate |
| Valve Construction | Ceramic stator surface for wear resistance and long-term sealing integrity |
| Brand | Agilent Technologies |
|---|---|
| Origin | Germany |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | 1260 Infinity III Multi-Wavelength Detector |
| Compatible System | HPLC |
| Detector Type | Diode Array Detector (DAD) |
| Wavelength Range | 190–950 nm |
| Short-Term Noise | < ±7 µAU (ASTM E1657-05) |
| Brand | Agilent Technologies |
|---|---|
| Origin | Germany |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | 1260 Infinity III Multisampler |
| Instrument Type | HPLC Autosampler |
| Maximum Sample Capacity | 6144 samples |
| Operating Pressure | Up to 600 bar (standard), up to 800 bar (with optional high-pressure kit) |
| Carryover | <9 ppm |
| Temperature Control Range (optional integrated thermostat) | 4–40 °C |
| Sample Tray Configurations | Three-height drawer system supporting vials and microplates |
| Microplate Capacity | Up to 16 standard microplates per drawer |
| Brand | Agilent Technologies |
|---|---|
| Origin | Germany |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | 1260 Infinity III Online Sampling Module |
| Instrument Type | HPLC Autosampler |
| Maximum Sample Capacity | 432 vials (2 mL) |
| Minimum Injection Volume | 0.1 µL |
| Dilution Ratio | Up to 1:1000 |
| Sampling Interface | External process-coupled interface for PAT integration |
| Compatible Injection Modes | Flow-through injection and Agilent FEED (Fast Equilibration Enhanced Dilution) injection |
| Brand | Agilent Technologies |
|---|---|
| Origin | Germany |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported Instrument |
| Model | 1260 Infinity III RID |
| Detection Principle | Differential Refractometry |
| Compatible Systems | Agilent 1200/1260/1290 Series HPLC & UHPLC Platforms |
| Detection Mode | Dual-Flow, Solvent-Compensated RI |
| Data Acquisition Rate | 74 Hz |
| Baseline Noise | < 2.5 nRIU (typical, 1 sec time constant) |
| Temperature Control | Electronic Thermal Control (ETC), 5–55 °C, ±0.01 °C stability |
| Flow Cell Volume | 8 µL |
| Lamp Type | Tungsten-Halogen, Lifetime > 2000 h |
| Auto-Compensation | Dynamic light intensity adjustment for lamp aging and flow cell fouling |
| Maintenance Access | Front-panel serviceable fluidic path and valves |
| EMF Monitoring | Real-time tracking of purge duration, lamp operating hours, and system diagnostics |
| Software Integration | Fully compatible with OpenLab CDS (ChemStation Edition), compliant with FDA 21 CFR Part 11 audit trail requirements |
| Brand | Agilent Technologies |
|---|---|
| Origin | Germany |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | 1260 Infinity III Sample Tray Autosampler |
| Instrument Type | HPLC Autosampler |
| Maximum Sample Capacity | 132 × 2 mL vials or 36 × 6 mL vials |
| Pressure Rating | 600 bar (G7129A) / 800 bar (G7129C) |
| Injection Volume Range | 0.1–100 µL (standard), extendable to 1500 µL (G7129C) or 1800 µL (G7129A) |
| Needle Wash Port | External surface rinse |
| Optional Integrated Column Oven | Temperature range 5 °C above ambient to 80 °C, accommodates two columns up to 30 cm |
| Optional Integrated Sample Thermostat | 4–40 °C temperature control |
| Internal Volume | Minimized design with bypass mode available |
| Brand | Agilent Technologies |
|---|---|
| Origin | Germany |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | 1260 Infinity III SFC Multisampler |
| Instrument Type | Supercritical Fluid Chromatography (SFC) Autosampler |
| Maximum Sample Capacity | 6144 |
| Injection Volume Range | 0.1–90 µL |
| Sample Container Compatibility | 2 mL Vials and Microtiter Plates (e.g., 96-well, 384-well) |
| Injection Technology | FEED (Forced Expansion and Efficient Delivery) |
| Temperature Control | Active Peltier-based Cooling/Heating |
| Brand | Agilent Technologies |
|---|---|
| Origin | Germany |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | 1260 Infinity III Variable Wavelength Detector |
| Compatible System | High-Performance Liquid Chromatography (HPLC) |
| Detector Type | UV-Vis Absorbance Detector |
| Data Acquisition Rate | Up to 120 Hz |
| Dual-Wavelength Mode | Yes |
| Baseline Noise | < ±0.25 × 10⁻⁵ AU |
| Drift | < 0.5 × 10⁻⁴ AU/h |
| Linear Range | > 2.5 AU |
| Wavelength Accuracy | ±1 nm (verified via built-in holmium oxide filter) |
| Temperature Control | Electronic Temperature Control (ETC) with active stabilization |
| Flow Cell Options | 8 interchangeable analytical and preparative flow cells (including 10 mm, 60 mm pathlengths |
| RFID Integration | Yes (for cell/lamp identification and usage traceability) |
| EMF Support | Yes (lamp hours, maintenance alerts, user-defined thresholds) |
| Brand | Agilent Technologies |
|---|---|
| Origin | Germany |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | 1290 Infinity III Bio Multisampler |
| Instrument Type | HPLC Autosampler |
| Maximum Sample Capacity | 6144 samples |
| Operating Pressure Rating | Up to 1300 bar |
| Temperature Control Range (optional integrated chiller/heater) | 4–40 °C |
| Sample Tray Flexibility | Three-height drawer configuration supporting vials and microplates (including shallow-format plates) |
| Carryover | <9 ppm with optional multi-wash and needle seat backflush |
| Sample Path Material | Biocompatible (low-binding, inert surfaces) |
| Brand | Agilent Technologies |
|---|---|
| Origin | Germany |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | 1290 Infinity III Bio Online Sample Manager |
| Instrument Type | HPLC Autosampler for Biopharmaceutical Applications |
| Maximum Sample Capacity | 432 vials (2 mL) |
| Minimum Injection Volume | 0.1 µL |
| Maximum System Pressure | 1300 bar |
| Temperature Control Range (Optional Integrated Thermostat) | 4–40 °C |
| Dilution Ratio | Up to 1:1000 |
| Sample Handling Modes | Flow-through injection, FEED (Fast Exchange and Dilution) injection, Retention mode with quenching and pre-processing capability |
| Brand | Agilent Technologies |
|---|---|
| Origin | Germany |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | 1290 Infinity III Diode Array Detector |
| Instrument Type | Diode Array Detector (DAD) |
| Noise Level | < ±3 µAU (10 mm flow cell, 1 s response time) |
| Signal Channels | Up to 8 simultaneous wavelength channels |
| Spectral Acquisition Rate | Up to 240 Hz |
| Optical Path Length Options | 10 mm (standard), 60 mm (high-sensitivity flow cell) |
| Baseline Drift | < ±0.6 µAU/cm (60 mm flow cell) |
| Linear Dynamic Range | Up to 2.5 AU (standard) |
| Slit Width Programmability | 1–8 nm |
| Temperature Control | Electronic Temperature Control (ETC) with RFID-tracked flow cell and lamp modules |
| Brand | Agilent Technologies |
|---|---|
| Origin | Germany |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | 1290 Infinity III Diode Array Detector FS |
| Detection Principle | UV-Vis Absorbance Spectroscopy via Photodiode Array |
| Instrument Type | Diode Array Detector (DAD) |
| Noise Level | ±0.6 µAU/cm (with 60 mm pathlength flow cell) |
| Signal Channels | Up to 8 simultaneous wavelength-specific signals |
| Sampling Rate | Up to 240 Hz |
| Flow Cell Options | MaxLight™ cartridge flow cells (10 mm and 60 mm pathlengths) |
| Compliance | Designed for GLP/GMP environments |
| Brand | Agilent Technologies |
|---|---|
| Origin | Germany |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | 1290 Infinity III ELSD |
| Detection Principle | Evaporative Light Scattering Detection |
| Compatibility | Integrated with Agilent 1290 Infinity III LC Systems and Third-Party HPLC Platforms |
| Sensitivity | Sub-nanogram detection capability for non-UV-absorbing analytes |
| Temperature Control Range | Peltier-cooled evaporator, 10–80 °C |
| Dynamic Range | Four decades (10⁴) |
| Reproducibility | RSD < 2% (n ≥ 6 injections, standard test conditions) |
| Response Time | < 0.1 s |
| Data Acquisition Rate | Up to 100 Hz |
| Gas Flow Control | Programmable, real-time nitrogen or air flow (0–3.0 L/min) |
| Solvent Compatibility | Fully compatible with gradient elution using volatile and semi-volatile mobile phases including acetonitrile, methanol, THF, and aqueous buffers — DMSO-free operation enabled |
| Brand | Agilent Technologies |
|---|---|
| Origin | Germany |
| Manufacturer | Agilent Technologies |
| Product Origin | Imported |
| Model | 1290 Infinity III MCT |
| Temperature Control | Peltier-based cooling and heating |
| Temperature Range | −20 °C below ambient to 110 °C |
| Maximum Column Capacity | 8 × 10 cm or 4 × 30 cm columns |
| Pressure Rating | 1300 bar |
| Column Identification | RFID-based tracking for up to 8 columns |
| Door Orientation | 90° or 180° configurable, removable for full access |
| Quick Connect Compatibility | InfinityLab Quick Connect fittings and thermal exchangers |
| Brand | Agilent Technologies |
|---|---|
| Origin | Germany |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | 1290 Infinity III Multisampler |
| Instrument Type | HPLC Autosampler |
| Maximum Sample Capacity | 6144 samples |
| Operating Pressure Rating | Up to 1300 bar |
| Carryover | < 9 ppm |
| Temperature Control Range (Optional Integrated Chiller/Heater) | 4–40 °C |
| Brand | Agilent Technologies |
|---|---|
| Origin | Germany |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported Instrument |
| Model | 1290 Infinity III RID |
| Instrument Type | Refractive Index Detector (RID) |
| Compatible System | Ultra-High Performance Liquid Chromatography (UHPLC) |
| Flow Cell Design | Ultra-Low Dispersion Micro-Flow Cell |
| Data Acquisition Rate | 148 Hz |
| Detection Principle | Differential Refractometry |
| Compliance | Designed for GLP/GMP environments with support for FDA 21 CFR Part 11–compliant software workflows |
| Brand | Agilent Technologies |
|---|---|
| Origin | Germany |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | 1290 Infinity III Sample Bottle Autosampler |
| Instrument Type | HPLC Autosampler |
| Maximum Sample Capacity | 132 × 2 mL vials or 36 × 6 mL vials |
| Pressure Rating | 1300 bar |
| Injection Volume Range | Up to 1500 µL |
| Needle Wash Port | External surface rinse capability |
| Optional Integrated Column Oven | Temperature range 5–80 °C above ambient, accommodates two columns up to 30 cm length |
| Optional Integrated Sample Thermostat | Temperature control from 4–40 °C |
| Internal System Volume | Minimized design with bypass mode available |
| Overlapped Run/Injection Cycle | Enabled for throughput optimization |
| Programmable Sequence Logic | Supports pre-injection sample conditioning and advanced scheduling |
| Brand | Agilent Technologies |
|---|---|
| Origin | Germany |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | 1290 Infinity III Variable Wavelength Detector |
| Compatible System | High-Performance Liquid Chromatography (HPLC) and Ultra-High-Performance Liquid Chromatography (UHPLC) |
| Detector Type | UV-Vis Absorbance Detector |
| Data Acquisition Rate | Up to 240 Hz |
| Baseline Noise | < ±0.25 × 10⁻⁵ AU |
| Drift | < 0.5 × 10⁻⁴ AU/h |
| Linear Dynamic Range | > 2.5 AU |
| Wavelength Range | 190–950 nm |
| Wavelength Accuracy | ±0.1 nm (verified via built-in holmium oxide filter) |
| Temperature Control | Electronic Temperature Control (ETC) with ±0.05 °C stability |
| Flow Cell Identification | RFID-enabled stainless steel or fused silica flow cells |
| Lamp Life Monitoring | Real-time EMF tracking with user-defined thresholds |
| Software Integration | Fully compatible with OpenLab CDS, MassHunter, and compliant with FDA 21 CFR Part 11 audit trail requirements |
| Brand | Agilent Technologies |
|---|---|
| Origin | Germany |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | 1290 Infinity III Wide Dynamic Range DAD |
| Instrument Type | Diode Array Detector (DAD) |
| Compatible System | Agilent InfinityLab LC Systems |
| Data Acquisition Rate | Up to 120 Hz (DAD FS variant) |
| Linear UV Dynamic Range Extension | 30× vs. conventional DAD |
| Temperature Control | Second-Generation Electronic Temperature Control (ETC) |
| Cell & Lamp Identification | RFID-enabled for audit-trail compliance |
| Flow Cell Pathlengths | Dual-path, optimized for high- and low-concentration analytes |
| Regulatory Support | Designed for GLP/GMP environments |
| Brand | Agilent Technologies |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Regional Classification | Domestic (China-manufactured) |
| Model | 7650A |
| Instrument Type | Gas Chromatography Autosampler |
| Maximum Sample Capacity | 50 vials |
| Syringe Options | 250 µL and 500 µL |
| Injection Modes | Single and Multi-injection |
| Priority Sample Insertion | Supported |
| Sample Overlap Capability | Yes |
| Needle Alignment | Fully Automated |
| Needle Illumination | Integrated LED lighting for visual verification and method development |
| Injection Technique | Fast, low-discrimination liquid-phase injection optimized for external standard calibration |
| Brand | Agilent Technologies |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Regional Classification | Domestic (China-manufactured) |
| Model | 7693A |
| Instrument Type | Gas Chromatography Autosampler |
| Pricing | Upon Request |
| Brand | Agilent Technologies |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Regional Classification | Domestic (China-manufactured) |
| Model | 7696A |
| Pricing | Upon Request |
| Instrument Type | Gas Chromatography (GC) Autosampler-Integrated Offline Sample Preparation System |
| Brand | Agilent Technologies |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Country of Origin | China |
| Model | 7697A |
| Instrument Type | Gas Chromatography Headspace Sampler |
| Maximum Sample Capacity | 12 vials (standard configuration) |
| Sample Vial Sizes Supported | 10 mL, 20 mL, 22 mL |
| Temperature Control Range (Transfer Line) | 35–250 °C (off to 250 °C) |
| Temperature Control Range (Valve & Loop) | 35–210 °C (off to 210 °C) |
| Temperature Control Range (Oven/Chamber) | 35–210 °C (off to 210 °C) |
| Pressure Control | Electronic Pressure Control (EPC) for valve and loop |
| Leak Detection | Automated vial leak check during pressurization |
| Operating Modes | Single Extraction, Multiple Headspace Extraction (MHE), Multiple Headspace Concentration (MHC) |
| MHE/MHC Cycles | Up to 100 cycles per vial |
| Method Development Support | Cross-platform method conversion and rapid re-optimization |
| Software Compatibility | Agilent OpenLab CDS, Agilent MassHunter, Waters Empower™ 2/3 |
| Barcode Reader | Integrated for sample tracking |
| Carrier Gas Options | Helium, Nitrogen, Hydrogen (H₂-safe design) |
| Peak Area Reproducibility | <1.5% RSD (standard mode) |
| Interfacing | Direct GC inlet coupling via transfer line interface |
| Brand | Agilent Technologies |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | Agilent 7697A |
| Sample Vial Capacity (Standard) | 111 positions, including 3 priority vial slots |
| Sample Vial Capacity (Optional) | 12-position configuration for academic or low-throughput labs |
| Vial Sizes Supported | 10 mL, 20 mL, and 22 mL vials without adapters |
| Injection Valve Loop Volume | Not specified in source data |
| Carrier Gas Compatibility | Hydrogen (H₂), Helium (He), Nitrogen (N₂) |
| Leak Detection | Automated, real-time vial pressure integrity check prior to analysis |
| Pressure Control | Independent headspace vial pressure and column head pressure regulation |
| Barcoding | Integrated sample vial barcode reader with LIMS-compatible data transmission |
| Method Transfer | Cross-platform method conversion and rapid re-optimization via Agilent Method Translation Software |
| Multi-HeadSpace Modes | Multiple Headspace Extraction (MHE) up to 100 cycles per vial |
| Vial Depressurization | Automatic post-analysis vial depressurization before return to tray |
| Interface | GC inlet-compatible transfer line kit for co-location with Agilent 7693A ALS on same GC inlet |