Chromatography Accessories
Filter
Showing 61–90 of 400 results
| Brand | Agilent Technologies |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic Instrument |
| Model | 8255 NCD |
| Pricing | Available Upon Request |
| Compatible Instrument | Gas Chromatograph (GC) |
| Detector Type | Selective Nitrogen-Specific Detector |
| Brand | Agilent Technologies |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | 8355 SCD |
| Pricing | Available Upon Request |
| Compatible Instrument | Gas Chromatograph (GC) |
| Detector Type | Elemental-Specific Chromatographic Detector |
| Brand | Agilent Technologies |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Regional Classification | Domestic (China-manufactured) |
| Model | 8697 |
| Instrument Type | Static Headspace Sampler |
| Automation Level | Fully Automatic |
| Valve Temperature Control Range | Ambient + 5 °C to 300 °C |
| Sample Vial Capacity | 48 positions |
| Compatible Vial Sizes | 10 mL, 20 mL, 22 mL |
| Brand | Agilent Technologies |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Regional Classification | Domestic (China-manufactured) |
| Model | 8697 |
| Pricing | Available upon request |
| Temperature Control Precision | Optional cooling plate enables sample stabilization at 4 °C |
| Vial Sizes Supported | 10 mL, 20 mL, 22 mL |
| Brand | Agilent Technologies |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | Flame Ionization Detector |
| Compatible Instruments | Agilent Intuvo 9000, 8890, 8860, and 7890 Series Gas Chromatographs |
| Detection Limit (n-tridecane) | ≤1.2 pg C/s (8890 GC), ≤1.4 pg C/s (Intuvo 9000 & 7890B GC), ≤3 pg C/s (8860 GC) |
| Linear Dynamic Range | >10⁷ (±10%) |
| Data Acquisition Rate | Up to 1000 Hz (Intuvo 9000 & 8890 GC) |
| Maximum Operating Temperature | 450 °C (8890/7890B/Intuvo 9000), 425 °C (8860) |
| Column Compatibility | Capillary-optimized or universal (capillary & packed column) variants available |
| Mounting Flexibility | Optional third-detector position on 8890 GC left side |
| Ignition Control | Auto-ignition and flame-out detection with recovery |
| Brand | Agilent Technologies |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | Load Lock |
| Instrument Type | Dynamic Axial Compression (DAC) System |
| Power Requirement | Pneumatic (Compressed Air Only) |
| Column Compatibility | Three Standard Bore Sizes |
| Compression Mode | Dual-Mode DAC + Static Axial Compression (SAC) |
| Application Scale | Milligram to Multi-Kilogram Preparative Chromatography |
| Brand | Agilent Technologies |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported |
| Model | micro-ECD |
| Compatible Instrument | Gas Chromatograph (GC) |
| Detector Type | Electron Capture Detector (ECD) |
| Detection Principle | Radioisotope-based electron capture |
| Minimum Detectable Level (MDL) for Lindane | 3.8 fg/mL |
| Linear Dynamic Range | 5 × 10⁴ (fg/mL to ng/mL) |
| Sampling Rate | 5–500 Hz |
| Compliance | U.S. EPA Contract Laboratory Program (CLP) Method 8081B/8270 for pesticide analysis |
| Brand | Agilent Technologies |
|---|---|
| Origin | Shanghai, China |
| Manufacturer | Agilent Technologies (Shanghai) Co., Ltd. |
| Type | Nitrogen-Phosphorus Detector (NPD) |
| Compatible Instrument | Gas Chromatograph (GC) |
| Bead Material | High-Performance Glass-Based Blos Rubidium Bead |
| Lifetime | ≥2× that of conventional ceramic rubidium beads |
| N-Compound Sensitivity | Comparable to ceramic beads |
| P-Compound Sensitivity | Enhanced vs. ceramic beads |
| Environmental Tolerance | High resistance to ambient humidity and moisture exposure |
| Regulatory Compliance | Designed for use in GLP/GMP environments |
| Brand | Agilent Technologies |
|---|---|
| Origin | Switzerland |
| Manufacturer | Agilent Technologies |
| Product Category | Imported Instrument |
| Model | PAL3 Series 2 |
| Instrument Type | Gas Chromatography Autosampler |
| Sample Capacity (2 mL vials) | up to 1458 (160 cm configuration) |
| Sample Capacity (10/20 mL vials) | up to 405 (160 cm configuration) |
| Compatible GC Platforms | Agilent 8890, 8860, Intuvo 9000, 7890, 7820 |
| Compatible Software | OpenLab CDS, MassHunter, ChemStation, EZChrom |
| Supported Sampling Modes | Liquid Injection, Static/Dynamic Headspace, SPME (Fiber & Arrow), RTC Tool Exchange |
| Integrated Sample Prep Functions | Dilution, Solvent Addition, Stirring, Centrifugation, Washing, Temperature-Controlled Handling |
| Consumables Intelligence | RFID/NFC-enabled smart chips for traceable usage history and automated reporting |
| Brand | Agilent Technologies |
|---|---|
| Origin | United Kingdom |
| Manufacturer | Markes International (OEM for Agilent) |
| Instrument Type | Thermal Desorption Autosampler for Gas Chromatography |
| Compatibility | Fully Integrated with Agilent GC and GC/MS Systems |
| Carrier Gases | Hydrogen, Helium, Nitrogen |
| Sample Capacity | Up to 100 Sorbent Tubes |
| Automation Mode | Stacked Tube Processing |
| Gas Configuration Options | 14-channel, 4-channel, or 3-channel online gas manifold |
| Brand | Agilent Technologies |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | TCD for GC Systems |
| Compatible Instruments | Agilent Intuvo 9000, 8890, 8860, and 7890 Gas Chromatographs |
| Detector Type | Universal Thermal Conductivity Detector |
| Baseline Drift | Ultra-low drift enabled by proprietary fluid-switching architecture with rapid post-startup stabilization |
| Brand | Agilent Technologies |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrumentation |
| Model Series | Lumin, AQUATek 100, Atomx |
| Instrument Type | Gas Chromatography (GC) Purge-and-Trap Sample Introduction System |
| Compliance | Designed for ASTM D5024, D6227, EPA Methods 502.2, 524.2, 624, 8260D, and ISO 15681-2 |
| Brand | AIGIS |
|---|---|
| Origin | Fujian, China |
| Manufacturer Type | OEM/ODM Producer |
| Valve Body Material | SUS316L / Alloy N60 / Hastelloy C / Hastelloy B |
| Rotor Material | PEEK |
| Max. Pressure (Gas) | 0.7 MPa |
| Max. Pressure (Liquid) | 3 MPa |
| Max. Operating Temperature | 250 °C |
| Flow Path Bore | 0.4 mm / 0.75 mm |
| Port Thread | 10-32 UNF Internal |
| Actuation | Electric (24 VDC / 2.5 A) or Pneumatic |
| Communication Interfaces | RS232, RS485, Digital I/O |
| Extended Stem Options | 2", 3", 4" |
| Brand | AIGIS |
|---|---|
| Origin | Fujian, China |
| Manufacturer Type | OEM Manufacturer |
| Product Category | Domestic (China-Made) |
| Model | AGS Valve Manifold Controller |
| Pricing | Upon Request |
| Brand | AIGIS |
|---|---|
| Origin | Fujian, China |
| Manufacturer Type | OEM/ODM Producer |
| Model | AGS-GBG10-ET-K75S2-2-N-A1-S |
| Valve Type | Multi-port (4/6/8/10/12/14-way) Rotary Switching Valve |
| Rotor Material | PEEK |
| Stator Body Material | SUS316L / Inconel 600 / Hastelloy C-276 |
| Max. Pressure Rating | 0–0.7 MPa (gas), 0–3 MPa (liquid) |
| Max. Operating Temperature | 200 °C |
| Flow Path Bore Diameter | 0.4 mm / 0.75 mm |
| Port Interface | 10-32 UNF female |
| Extension Stem Options | 2", 3", 4", 6" |
| Actuation | Pneumatic or 24 VDC ±10% Electric |
| Pneumatic Supply Pressure | 30–80 psi |
| Electrical Interface | RS232 / RS485 (19200 bps, default address 01) |
| Brand | AIGIS |
|---|---|
| Model | Multi-Position Multi-Port Selection Valve Series |
| Valve Types | Inlet Valve, Injection Valve, Column Positioning Valve, Bypass Valve, Fraction Collection Valve |
| Body Material | PEEK / SUS316L |
| Max Operating Pressure | 4.0 MPa |
| Flow Range | 0–300 mL/min |
| Port Configurations | 1–6 positions, 4–14 ports |
| Internal Bore Options | 0.75 mm, 1.0 mm, 1.5 mm, 3.0 mm, 3.2 mm, 4.0 mm |
| Compliance | Designed for GLP/GMP-compliant chromatography workflows |
| Origin | Fujian, China |
| Manufacturer Type | OEM/ODM Manufacturer |
| Brand | All Precision Instrument |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | OEM Manufacturer |
| Instrument Type | GC Autosampler |
| Model | BKQ-20 |
| Sample Vial Capacity | 12 mL |
| Maximum Vial Count | 196 (14 × 14 array) |
| Positioning Accuracy | ±0.01 mm |
| Power Input | AC 220 V |
| Display | Blue TFT LCD |
| Dimensions (W × D × H) | 490 mm × 482 mm × 330 mm |
| GC Synchronization | Triggered via TTL/relay signal |
| Vacuum Reconditioning | Integrated for vial reuse |
| Communication Interfaces | RS-232, USB, optional Ethernet |
| Sample Injection Modes | Headspace, direct gas loop, split/splitless compatible |
| Brand | Annuo |
|---|---|
| Origin | Henan, China |
| Model | AS-3016 |
| Sample Capacity | 160 × 2 mL vials |
| Minimum Injection Volume | 0.1 µL |
| Standard Loop Volume | 10 µL |
| Positioning Accuracy | ±0.3 mm |
| Motion Architecture | Vertical tower with optional expansion tray |
| Needle Wash Cycles | 99 internal rinses per injection |
| Replicate Injections per Vial | up to 99 |
| Injection Speed | configurable down to 0.1 s per injection |
| Injection Depth Range | –2 to 35 mm |
| Sample Tray Encoding | absolute-position optical encoder |
| Communication Protocols | Modbus RTU, USB 2.0, TTL I/O (compatible with major GC vendors) |
| Operating Temperature | –20 °C to 50 °C |
| Storage Temperature | –40 °C to 70 °C |
| Relative Humidity (operating) | 10–90% RH non-condensing |
| Brand | Annuo |
|---|---|
| Origin | Henan, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | AS-3016B |
| Instrument Type | Multifunctional Autosampler |
| Maximum Sample Capacity | 160 positions |
| Minimum Injection Volume | 0.1 µL |
| Quantitative Loop Volumes | 0.5, 1, 5, 10, 25, 50, and 500 µL |
| Positioning Accuracy | ≤ 0.3 mm |
| Motion System | XYZ three-axis robotic arm |
| Needle Wash Cycles | up to 99 |
| Re-injection Repetitions | up to 99 |
| Brand | Annuo |
|---|---|
| Origin | Henan, China |
| Model | AS-3016C |
| Instrument Type | GC Autosampler |
| Max Sample Capacity | 24–160 positions (standard 24, expandable to 160) |
| Minimum Injection Volume | 0.1 µL |
| Quantitative Loop Volume Range | 0.5–500 µL (user-selectable) |
| Positioning Accuracy | ±0.1 mm |
| Motion Architecture | Vertical Tower (Z-axis linear actuation) |
| Needle Wash | Internal & External Wall Rinse, Unlimited Cycles |
| Repeat Injection Capability | Unlimited (user-configurable) |
| Syringe Options | 1, 5, 10, 25, 50, 100, 250, 500 µL |
| Solvent Bottle Positions | 2 (expandable to 11) |
| Waste Bottle Positions | 1 (expandable to 5) |
| Per-Vial Injection Count | 1–99 |
| Maximum Time Interval Between Injections | 999 min |
| Viscosity Delay | 0–60 s |
| Pre-/Post-Insertion Dwell Time | 0–120 s |
| Needle Penetration Speed | Fast / Slow / Custom |
| Aspiration/Dispense Speed | Fast / Slow / Custom |
| Injection Modes | Conventional, Continuous, Sample+L1, Sample+L1+L2, PTV-compatible |
| Control Interface | TTL-triggered interval control, GC signal reverse-triggering, USB 2.0, Modbus RTU over RS-485 |
| Dual-Tower Injection Time Reproducibility | < 1 ms |
| Barcode Scanning Support | Yes |
| Sample Temperature Control | Optional integrated cooling/heating module |
| Operating Temperature | −20 °C to +50 °C |
| Storage Temperature | −40 °C to +70 °C |
| Operating Humidity | 10–90% RH (non-condensing) |
| Storage Humidity | 5–90% RH |
| Brand | Annuo |
|---|---|
| Origin | Henan, China |
| Model | AS-3117 |
| Sample Capacity | 156-position 2 mL vial tray + 15-position auxiliary tray |
| Minimum Injection Volume | 0.01 µL |
| Quantitative Loop Volume | 10 µL |
| Positioning Accuracy | ≤ 0.3 mm |
| Motion Mechanism | Turret-based |
| Needle Wash | Internal Wall Rinse |
| Repeat Injection Cycles | Up to 99 |
| Operating Temperature Range | −20 °C to 50 °C (operational), −40 °C to 70 °C (storage) |
| Relative Humidity Range | 10–90% RH (operational), 5–90% RH (storage) |
| Communication Protocol | Modbus RTU |
| I/O Interface | Configurable digital I/O for GC synchronization |
| Control Modes | Interval-triggered, signal-triggered (TTL/relay), and full PC-based remote control |
| Brand | Annuo |
|---|---|
| Origin | Henan, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | AS-3117B |
| Instrument Type | GC Autosampler |
| Max Sample Capacity | 20 positions (expandable to 156) |
| Minimum Injection Volume | 0.1 µL |
| Positioning Accuracy | < 0.1 mm |
| Motion Mechanism | Turret-based |
| Needle Wash Mode | Selectable (pre- and/or post-injection) |
| Repeat Injection Count | Up to 99 cycles per sample |
| Brand | Annuo |
|---|---|
| Origin | Henan, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | GAS-3519 |
| Instrument Type | Gas Chromatography Autosampler |
| Max Sample Capacity | 88 positions |
| Minimum Sample Volume | 1 mL |
| Quantitative Loop Volumes | 1 mL / 2 mL / 3 mL |
| Positioning Accuracy | <0.1 mm |
| Sampling Mechanism | Quantitative Loop Injection |
| Needle/Line Cleaning | Fully Automated |
| Repeat Injection Cycles per Sample | Up to 99 |
| Brand | Annuo |
|---|---|
| Origin | Henan, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | GAS-3519-XS |
| Instrument Type | Gas Chromatography (GC) Gas Bag Autosampler |
| Maximum Sample Volume | 5 mL |
| Minimum Sample Volume | 1 mL |
| Quantitative Loop Volume Range | 0.05–5 mL |
| Positioning Accuracy | RSD < 0.5% for total hydrocarbon and methane peak areas across 10 consecutive injections |
| Control Method | PC-based host software control |
| Needle/Line Cleaning | Integrated pneumatic line purge with inert gas |
| Repeat Injection Count | 1–99 times per sample |
| Sample Tray Capacity | 11 / 28 / 40 positions (expandable to 88) |
| Quantitative Loop & Line Heating Range | Ambient to 150 °C |
| Sample & Standard Dilution Ratio | Up to 1:200 (customizable) |
| Sampling Pump | Max flow 6 L/min |
| Sampling Time Parameters | Max draw time 99 s, max equilibration time 99 s, max purge time 600 s |
| Tubing Material | PTFE |
| Valve Actuator | PEEK body with PI (polyimide) rotor |
| Data Interfaces | USB, Ethernet (RJ45), RS-232 |
| Brand | Annuo |
|---|---|
| Origin | Henan, China |
| Model | GAS-3529A-16 |
| Instrument Type | Gas Chromatography Autosampler |
| Max Sampling Rate | 6 L/min |
| Ultimate Vacuum | −55 kPa |
| Minimum Sample Volume | 1 mL (configurable to 2 mL or 3 mL) |
| Quantitative Loop Volume | 1 mL / 2 mL / 3 mL (user-selectable) |
| Positioning Accuracy | RSD < 1% for total hydrocarbon and methane peak areas across 10 consecutive injections |
| Sample Capacity | 16 positions (base unit) |
| Dimensions (L×W×H) | 40 × 50 × 37 cm (height increases by 15 cm per added module) |
| Cleaning | Automated syringe needle path flush + quantitative loop purge + gas bag rinse |
| Valve Actuation | PEEK body with PI (polyimide) rotor |
| Tubing Material | PTFE and PEEK only |
| Data Interfaces | USB, Ethernet (RJ45), RS-232 |
| Compliance | Meets GB/T 33642–2017 (Chinese national standard for gas sampling systems in GC applications) |
| Brand | Annuo |
|---|---|
| Origin | Henan, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | GAS-3539 |
| Instrument Type | Multifunctional Gas Autosampler |
| Max Sample Positions | 88 |
| Min Sample Positions | 16 |
| Quantitative Loop Volumes | 1 mL, 2 mL, 3 mL (selectable) |
| Positioning Accuracy | RSD <0.5% for total hydrocarbon and methane peak areas across 10 consecutive injections |
| Control Interface | PC-based upper-computer software |
| Needle & Loop Cleaning | Automated in-line cleaning of sampling lines, quantitative loops, gas bags, and sample pathways during GC coupling |
| Repeat Injection Capability | Unlimited cycles per sample |
| Operating Temperature Range | −20 °C to 50 °C |
| Storage Temperature Range | −40 °C to 70 °C |
| Humidity Range (Operating) | 10–90% RH |
| Humidity Range (Storage) | 5–90% RH |
| Syringe Capacity | 100 mL |
| Gas Bag Capacity | 500 mL or 1 L |
| Minimum Injection Volume | 50 µL (loop-dependent) |
| Maximum Injection Volume | 5 mL (loop-dependent) |
| Max Purge Time | 600 s |
| Max Draw Time | 99 s |
| Max Equilibration Time | 99 s |
| Max Interval Between Injections | 999 min |
| Quantitative Loop Heating Range | Ambient to 150 °C |
| Sample Pathway Heating Range | Ambient to 150 °C |
| Calibration Standard Points | Up to 8 programmable concentration levels |
| Cleaning Cycles per Step | 1–15 |
| Sampling Pump Flow Rate | Up to 6 L/min |
| Ultimate Vacuum | −55 kPa |
| Data Interfaces | USB, Ethernet (RJ45), RS-232 |
| Dimensions (L×W×H) | 900 × 600 × 900 mm |
| Tubing Material | Silanized stainless steel |
| Valve Body | PEEK |
| Valve Core | PI (Polyimide) |
| Sample Port Flexibility | Dual-mode — gas bag or syringe injection per port |
| High-Concentration Detection Logic | Auto-halt + GC oven ramp initiation upon detection of saturation-level analyte signals |
| Brand | Annuo |
|---|---|
| Origin | Henan, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | LAS-3622 |
| Instrument Type | HPLC Autosampler |
| Max Sample Capacity | 200 positions |
| Minimum Injection Volume | 0.1 µL–2 mL |
| Loop Volumes | 50 µL, 100 µL, 250 µL, 1000 µL |
| Positioning Accuracy | <1% RSD at 1 µL, <0.5% RSD at 5 µL, <0.3% RSD at 10 µL |
| Sampling Mechanism | Loop-based injection |
| Needle Wash Modes | Automated line purge, bubble removal, pre-injection wash, post-injection wash |
| Repeat Injection Capability | Unlimited cycles per sample |
| Brand | Antec |
|---|---|
| Origin | Netherlands |
| Model | DECADE Elite |
| Detector Type | Electrochemical Detector (ECD) |
| Compatible Systems | HPLC, UHPLC, EC-MS Coupling |
| Operating Modes | DC, Pulsed, Scanning |
| Signal Processing | Advanced Digital Filter (ADF) |
| Flow Cell Volume Range | 0–300 nL (continuously adjustable) |
| Cell Design | Central Jet-Wall Electrode Configuration |
| Temperature Control | Integrated Faraday-Shielded Thermostatic Chamber |
| Compliance | Designed for GLP/GMP environments |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | DECADE II |
| Pricing | Upon Request |
| Detector Type | Electrochemical Detector (ED) |
| Brand | Antec |
|---|---|
| Origin | Netherlands |
| Model | DECADE II |
| Detector Type | Electrochemical Detector (ECD) |
| Operating Modes | DC, Pulse, and Scan |
| Digital Filter Range | 0.5–0.001 Hz (1–2–5 decade steps) |
| Potential Range | ±2.00 V |
| Faraday Column Oven Dimensions | H 37 cm |
| Temperature Range | Ambient +7 °C to 45 °C |
| Temp. Stability | ±0.1 °C |
| Flow Cell Types | Central Jet Wall-Flow Cell & Conventional Thin-Layer Cell |
| Electrode Configurations | SCC, DCC, TCC, QCC |