Chromatography Accessories
Filter
Showing 91–120 of 400 results
| Brand | Antec |
|---|---|
| Origin | Netherlands |
| Model | DECADE II SDC |
| Detector Type | Electrochemical Detector (ECD) |
| Operating Modes | DC Amperometry with Advanced Digital Filtering (ADF) |
| Filter Frequency Range | 0.5–0.001 Hz (decade steps: 1, 2, 5) |
| Potential Range | ±2.00 V |
| Faraday Column Oven Dimensions | Height 37 cm |
| Temperature Range | Ambient +7 °C to 45 °C |
| Temperature Stability | ±0.1 °C |
| Flow Cell Types | Central-jet wall-type electrode (compatible with standard & capillary HPLC columns) and conventional thin-layer electrode |
| Electrode Configurability | Interchangeable working and reference electrodes (e.g., glassy carbon, gold, platinum, Ag/AgCl) |
| Brand | APL |
|---|---|
| Origin | Sichuan, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | APL-AGS-36 |
| Instrument Type | Gas Chromatography Autosampler |
| Max Sample Capacity | 132 positions |
| Minimum Injection Volume | 1 mL |
| Quantitative Loop Volume | 1 mL |
| Sample Tray Configuration | 36-position base (expandable in 12-position modules) |
| Compatible Sampling Devices | Gas-tight syringes and Tedlar®/aluminized gas bags |
| Tubing Material | PTFE |
| Valve Body | PEEK |
| Valve Core | Polyimide (PI) |
| Carrier Gas Line Purge Flow Rate | Up to 0.5 L/min |
| Injection Precision | R² ≥ 0.9999 for total hydrocarbons and methane peak areas across five replicate injections |
| Dimensions (L×W×H) | 450 × 500 × 430 mm |
| Brand | APL |
|---|---|
| Origin | Sichuan, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Classification | Domestic (China) |
| Model | APL-AS-24 |
| Instrument Type | Gas Chromatography Autosampler |
| Maximum Sample Capacity | 24 positions (expandable to 160) |
| Minimum Injection Volume | 0.1 µL |
| Maximum Injection Volume | 250 µL |
| Replicate Injections per Vial | up to 99 |
| Syringe Options | 1, 5, 10, 25, 50, 100, 250, 500 µL |
| Solvent Bottle Positions | 2 (expandable to 11) |
| Waste Bottle Positions | 1 (expandable to 5) |
| Method Storage | up to 20 methods |
| Needle Wash Cycles | up to 99 |
| Pump Draw Cycles | up to 99 |
| Viscosity Delay | 0–60 s |
| Dwell Time Pre-/Post-Insertion | 0–120 s |
| Injection Timing Reproducibility (Dual-Tower Mode) | < 1 ms |
| Communication Interfaces | Modbus RTU, USB 2.0 |
| Operating Temperature | −20 °C to 50 °C |
| Storage Temperature | −40 °C to 70 °C |
| Operating Humidity | 10–90% RH |
| Storage Humidity | 5–90% RH |
| Brand | APL |
|---|---|
| Origin | Sichuan, China |
| Manufacturer Type | OEM Manufacturer |
| Product Category | Domestic |
| Model | APL-FHS 300 |
| Instrument Type | Multifunctional Autosampler |
| Max Sample Capacity | 180-position liquid tray / 70-position headspace tray / 70-position SPME tray |
| Minimum Liquid Injection Volume | 0.01 µL |
| Motion Control | XYZ three-axis precision positioning |
| Brand | APL |
|---|---|
| Origin | Sichuan, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Static Headspace Sampler |
| Automation Level | Fully Automated |
| Sample Tray Capacity | 16 positions (all heated) |
| Vial Size Compatibility | 10 mL and 20 mL (20 mL standard) |
| Oven Temperature Range | Ambient to 260 °C |
| Valve & Transfer Line Temperature Range | Ambient to 220 °C |
| Temperature Control Accuracy | ±0.1 °C |
| Loop Volume | 1 mL |
| Pressurization Range | 0–0.4 MPa (continuously adjustable) |
| Purge Flow Rate | 0–400 mL/min (continuously adjustable) |
| Precision | RSD ≤1.5% (ethanol in water, 400 ppm, n=5) |
| Brand | APL |
|---|---|
| Origin | Sichuan, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Static Headspace Sampler |
| Automation Level | Fully Automated |
| Sample Vial Heating Range | Ambient to 260 °C |
| Valve & Transfer Line Temperature Control Range | Ambient to 220 °C |
| Temperature Control Accuracy | ±0.1 °C |
| Loop Volume | 1 mL |
| Vial Capacity | 40 positions |
| Vial Size Compatibility | 20 mL (standard), 10 mL (optional) |
| Precision | RSD ≤1% (200 ppm ethanol in water, n=5) |
| Pressure-Controlled Injection Range | 0–0.4 MPa (adjustable) |
| Purge Flow Rate | 0–400 mL/min (adjustable) |
| Brand | APL |
|---|---|
| Origin | Sichuan, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Static Headspace Sampler |
| Automation Level | Fully Automated |
| Sample Tray Capacity | 60 positions (15 heated positions) |
| Backup Positions | 20 |
| Vial Size Compatibility | 10 mL and 20 mL (standard) |
| Oven Temperature Range | Ambient to 260 °C (1 °C increment) |
| Valve & Transfer Line Temperature Range | Ambient to 220 °C (1 °C increment) |
| Temperature Accuracy | ±0.1 °C |
| Pressure-Controlled Injection | 0–0.4 MPa (adjustable) |
| Purge Flow Rate | 0–400 mL/min (adjustable) |
| Precision | RSD ≤1% (200 ppm ethanol in water, n=5) |
| Injection Volume Control | Pressurization time + regulated pressure |
| Brand | APL |
|---|---|
| Origin | Sichuan, China |
| Manufacturer Type | Manufacturer |
| Origin Category | Domestic |
| Model | APL-PT-100 |
| Sample Capacity | 100 positions |
| Injection Precision | RSD < 3% |
| Trap Temperature Range | −30 °C to 400 °C |
| Purge Sample Heating Temperature | Ambient to 120 °C |
| Sample Vial Cooling Temperature | −30 °C |
| Brand | APL |
|---|---|
| Origin | Sichuan, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Category | Domestic (China-made) |
| Model | APL-PT-75 |
| Sample Tray Capacity | 75 positions |
| Injection Precision | RSD < 3% |
| Trap Temperature Range | –30 °C to 400 °C |
| Sample Heating Temperature | Ambient to 120 °C |
| Sample Vial Cooling Temperature | –30 °C |
| Purge Gas Flow Rate | 0–100 mL/min (adjustable) |
| Back-Flush Flow Rate | 0–100 mL/min (adjustable) |
| Water Removal Trap Temp | Ambient to 240 °C |
| Valve & Transfer Line Temp | Ambient to 220 °C |
| Sample Vial Size | 40 mL |
| Brand | APL |
|---|---|
| Origin | Sichuan, China |
| Manufacturer Type | Manufacturer |
| Product Category | Domestic |
| Model | APL-TD-1 |
| Instrument Type | Primary Thermal Desorber |
| Automation Level | Fully Automatic |
| Desorption Temperature Range | Ambient to 400 °C |
| Cold Trap Temperature Range | −35 °C to 25 °C (Note: Input states “25” — interpreted as upper limit of ambient-cooled trap |
| Desorption Recovery Rate | >98% |
| Sample Position Capacity | 1 |
| Brand | APL |
|---|---|
| Origin | Sichuan, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | APL-TD-100 |
| Instrument Type | Two-Stage Thermal Desorber / Thermal Desorption Unit |
| Automation Level | Fully Automated |
| Primary Desorption Temperature Range | Ambient to 400 °C (±1 °C) |
| Secondary Desorption Temperature Range | −35 °C to 400 °C (±1 °C) |
| Secondary Flash Heating Rate | ≥3000 °C/min |
| Valve Oven Temperature Range | Ambient to 300 °C (±1 °C) |
| Transfer Line Temperature Range | Ambient to 300 °C (±1 °C) |
| Cold Trap Temperature Range | −35 °C (±0.5 °C) |
| Temperature Control Accuracy | ±1 °C |
| Desorption Recovery Efficiency | >98% |
| Sample Capacity | 100 positions |
| Tube Standard | ASTM D6196-22 / ISO 16017-1 compliant 89 mm × 6.4 mm (3.5″ × 1/4″) adsorption tubes |
| Brand | APL |
|---|---|
| Origin | Sichuan, China |
| Manufacturer Type | Manufacturer |
| Product Category | Domestic |
| Model | APL-TD-2 |
| Instrument Type | Two-Stage Thermal Desorber, Thermal Desorber |
| Desorption Temperature Range | Ambient to 400 °C |
| Cold Trap Temperature Range | −35 °C |
| Desorption Recovery Rate | >98% |
| Sample Position Count | 1 |
| Brand | APL |
|---|---|
| Origin | Sichuan, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Dual-Stage Thermal Desorber |
| Automation Level | Fully Automated |
| Desorption Temperature Range | Ambient to 400 °C |
| Valve & Injection Port Temperature Range | Ambient to 220 °C |
| Transfer Line Temperature Range | Ambient to 260 °C |
| Cold Trap Temperature | −35 °C |
| Temperature Control Accuracy | ±1 °C |
| Analyte Recovery Rate | >98% (compound-dependent) |
| Sample Capacity | 50 Adsorption Tubes |
| Brand | APL |
|---|---|
| Origin | Sichuan, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | APL-TD-50D |
| Instrument Type | Two-Stage Thermal Desorber / Thermal Desorption Unit |
| Automation Level | Fully Automated |
| Desorption Temperature Range | –35 °C to 400 °C |
| Valve Injection Zone Temperature Range | Ambient to 300 °C |
| Transfer Line Temperature Range | Ambient to 300 °C |
| Cold Trap Temperature Range | –35 °C |
| Temperature Control Accuracy | ±1 °C |
| Analyte Recovery Rate | >98% |
| Sample Capacity | 50 Adsorption Tubes |
| Brand | APL |
|---|---|
| Origin | Sichuan, China |
| Manufacturer Type | Direct Manufacturer |
| Region Category | Domestic (China) |
| Model | DK-400 |
| Instrument Type | Static Headspace Sampler |
| Automation Level | Manual Operation |
| Vial Heating Range | Ambient to 250 °C |
| Valve & Transfer Line Temperature Control Range | Ambient to 220 °C |
| Sample Loop Volume | 1.0 mL |
| Vial Capacity | 9 positions |
| Vial Size | 40 mL |
| Brand | APL |
|---|---|
| Origin | Sichuan, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | HS-12 |
| Instrument Type | Static Headspace Sampler |
| Automation Level | Semi-Automatic |
| Sample Vial Heating Range | Ambient to 250 °C |
| Valve Temperature Control Range | Ambient to 220 °C |
| Loop Volume | 2 mL |
| Vial Capacity | 12 positions |
| Vial Size | 20 mL |
| Brand | APL |
|---|---|
| Origin | Sichuan, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Static Headspace Sampler |
| Automation Level | Fully Automatic |
| Sample Tray Capacity | 20 positions |
| Vial Size | 20 mL (also compatible with 10 mL) |
| Oven Temperature Range | Ambient to 260 °C |
| Valve & Transfer Line Temperature Range | Ambient to 220 °C |
| Quantitative Loop Volume | 1 mL |
| Pressure Control Range | 0–0.4 MPa (adjustable) |
| Backflush Flow Rate | 0–400 mL/min (adjustable) |
| Temperature Stability | < ±0.1 °C |
| Precision | RSD ≤ 1% (200 ppm ethanol in water, n = 5) |
| Brand | APL |
|---|---|
| Origin | Sichuan, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Static Headspace Sampler |
| Automation Level | Fully Automated |
| Sample Tray Capacity | 20 positions |
| Vial Size | 20 mL (standard), 10 mL (optional) |
| Oven Temperature Range | Ambient to 260 °C |
| Valve & Transfer Line Temperature Range | Ambient to 220 °C |
| Loop Volume | 1 mL |
| Pressure Control Range | 0–0.4 MPa (adjustable) |
| Purge Flow Rate | 0–400 mL/min (adjustable) |
| Temperature Stability | < ±0.1 °C |
| Precision | RSD ≤ 1% (200 ppm ethanol in water, n = 5) |
| Brand | APL |
|---|---|
| Origin | Sichuan, China |
| Manufacturer Type | Direct Manufacturer |
| Origin Category | Domestic (China) |
| Model | HS-45 |
| Instrument Type | Static Headspace Sampler |
| Automation Level | Fully Automated |
| Vial Heating Range | Ambient to 260 °C (1 °C increments) |
| Valve Temperature Control Range | Ambient to 240 °C (1 °C increments) |
| Sample Loop Volume | 1 mL |
| Temperature Control Accuracy | ±0.1 °C |
| Vial Capacity | 45 positions |
| Compatible Vial Sizes | 10 mL and 20 mL |
| Brand | APL |
|---|---|
| Origin | Sichuan, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Static Headspace Sampler |
| Automation Level | Fully Automated |
| Sample Tray Capacity | 80 positions |
| Vial Sizes Supported | 10 mL and 20 mL |
| Oven Temperature Range | Ambient to 260 °C (1 °C increments) |
| Valve Temperature Range | Ambient to 240 °C (1 °C increments) |
| Loop Volume | 1 mL |
| Temperature Control Accuracy | ±0.1 °C |
| Independent Heated Zones | Sample oven, injection valve, transfer line, and needle |
| Agitation | Adjustable speed, integrated into each of 15 heated positions |
| System Purge | Automatic inert gas flush after each injection |
| Leak Detection | Real-time vial presence verification |
| Software Interface | 7-inch touchscreen with bilingual (English/Chinese) UI, method storage, real-time GC status display (carrier gas & pressurization pressure), AFM-based flow monitoring |
| Compliance Support | Designed for GLP/GMP environments with audit-ready method logging, event timestamping, and system self-test at power-on |
| Mechanical Architecture | Dual three-axis rotary gantry for precise vial handling, piercing, sampling, and injection |
| Brand | APL |
|---|---|
| Origin | Sichuan, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Static Headspace Sampler |
| Automation Level | Semi-Automatic |
| Sample Vial Heating Range | Ambient to 250 °C |
| Valve Temperature Control Range | Ambient to 220 °C |
| Loop Volume | 2 mL |
| Vial Positions | 9 |
| Vial Capacity | 20 mL |
| Temperature Setting Increment | 1 °C |
| Temperature Stability | < ±0.1 °C |
| RSD (Repeatability) | < 1.5% |
| Pressurization Range | 0–0.4 MPa (adjustable) |
| Purge Flow Rate | 0–20 mL/min (adjustable) |
| Interface | Touchscreen with Time-Programmed Sequence Control |
| GC Synchronization | Supported via TTL or external trigger |
| Brand | APL |
|---|---|
| Origin | Sichuan, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Classification | Domestic (China) |
| Model | HS-Auto126 |
| Instrument Type | Static Headspace Sampler |
| Automation Level | Fully Automatic |
| Sample Vial Heating Range | Ambient to 280 °C |
| Valve Temperature Control Range | Ambient to 280 °C |
| Sample Loop Volume | 1 mL / 2 mL |
| Temperature Control Accuracy | ±0.1 °C |
| Sample Capacity | 126 positions |
| Vial Format | 20 mL standard (10 mL optional) |
| Sample Zone Heating Range | Ambient to 260 °C |
| Valve & Transfer Line Heating Range | Ambient to 220 °C |
| Precision | RSD ≤1% (200 ppm ethanol in water, n=5) |
| Pressurization Range | 0–0.4 MPa (adjustable) |
| Purge Flow Rate | 0–100 mL/min (adjustable) |
| Vial Heating Positions | 15 |
| Oscillation Mode | Vertical wave-like agitation during equilibration |
| Display | 7-inch capacitive touchscreen |
| Method Storage | Preloaded compliance methods (e.g., EPA 502.2, USP <467>, ISO 11843-3) |
| Brand | APL Optol |
|---|---|
| Model | PT-75D |
| Sample Capacity | 75 positions |
| Injection Precision | RSD < 3% |
| Trap Temperature Range | −30 °C to 400 °C |
| Sample Heating Range | Ambient to 120 °C |
| Sample Vial Cooling | −30 °C |
| Water Removal Trap Temp | Ambient to 240 °C |
| Valve & Transfer Line Temp | Ambient to 220 °C |
| Purge Flow | 0–100 mL/min (adjustable) |
| Desorption Time | 1–3 min |
| Bake-out Temp | Up to 250 °C |
| Vial Format | 40 mL |
| Brand | APL Optolab |
|---|---|
| Origin | Sichuan, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Model | APL-PTC30 |
| Sample Capacity | 30 positions |
| Injection Precision | RSD < 3% |
| Trap Temperature Range | −30 °C to 400 °C |
| Sample Heating Temperature | Ambient to 120 °C |
| Vial Cooling Temperature | −30 °C |
| Purge Flow Rate | 0–100 mL/min (adjustable) |
| Desorption Time | 1–3 min |
| Bake-out Temperature | Up to 250 °C |
| Trap Desorption Efficiency | Optimized for VOCs with C2–C12 volatility range |
| Compliance | ASTM D6866, EPA Method 502.2, EPA Method 524.2, EPA Method 8260D, HJ 605–2011, HJ 639–2012, HJ 686–2014, HJ 713–2014, HJ 735–2015, HJ 866–2017, HJ 893–2017, HJ 896–2017, HJ 1020–2019, SL 393–2007 |
| Brand | APL |
|---|---|
| Origin | Sichuan, China |
| Manufacturer Type | Manufacturer |
| Region of Origin | Domestic (China) |
| Model | APL-TD25 |
| Instrument Type | Dual-Stage Thermal Desorber |
| Automation Level | Fully Automated |
| Desorption Temperature Range | −35 °C to 400 °C |
| Valve Injection Zone Temperature Range | Ambient to 300 °C |
| Transfer Line Temperature Range | Ambient to 300 °C |
| Cold Trap Temperature Range | −35 °C |
| Temperature Control Accuracy | < ±0.1 °C |
| Analyte Recovery Rate | >98% (compound-dependent) |
| Sample Capacity | 25 adsorption tubes |
| Brand | APL Optolong |
|---|---|
| Model | APL-TD-2D |
| Origin | Sichuan, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Dual-Stage Thermal Desorber |
| Desorption Temperature Range | Ambient to 400 °C |
| Cryo-Focusing Trap Temperature | −20 °C (Peltier-cooled) |
| Analyte Recovery Rate | >98% |
| Sample Position Capacity | 1 tube per run |
| Valve System | Motorized 6-Port Rotary Valve + Solenoid Valves |
| Sample Tube Standard | 89 mm length × 6.4 mm OD, max. 420 °C tolerance |
| Flash Heating Rate (2nd Stage) | >3000 °C/min |
| Transfer Line Temp Control | Ambient to 260 °C, ±1 °C |
| GC Trigger Output | TTL-compatible synchronous pulse |
| Brand | APL Optolong |
|---|---|
| Origin | Sichuan, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | APL-TD-50A |
| Instrument Type | Two-Stage Thermal Desorber / Thermal Desorption Unit |
| Automation Level | Fully Automatic |
| Desorption Temperature Range | −35 °C to 400 °C |
| Valve & Injection Zone Temperature Range | Ambient to 220 °C |
| Transfer Line Temperature Range | Ambient to 260 °C |
| Cold Trap Temperature Range | −35 °C |
| Temperature Control Accuracy | ±1 °C |
| Desorption Recovery Rate | >98% (compound-dependent) |
| Sample Capacity | 50 positions |
| Brand | APL Optolong |
|---|---|
| Origin | Sichuan, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | APL-TD20N |
| Instrument Type | Dual-Stage Thermal Desorber |
| Desorption Temperature Range | –35 °C to 400 °C |
| Cold Trap Temperature Range | –35 °C |
| Desorption Recovery Rate | >98% (compound-dependent) |
| Sample Capacity | 20 adsorption tubes |
| Brand | APL |
|---|---|
| Origin | Sichuan, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | PT30D |
| Instrument Type | Water & Soil Integrated VOC Analyzer |
| Sample Tray Capacity | 30 positions |
| Injection Precision | RSD < 3% |
| Trap Temperature Range | –30 °C to 400 °C |
| Sample Heating Temperature | Ambient to 120 °C |
| Vial Cooling Temperature | –30 °C |
| Desiccant Trap Temperature | Ambient to 240 °C |
| Valve & Transfer Line Temperature | Ambient to 220 °C |
| Purge Flow Rate | 0–100 mL/min (adjustable) |
| Back-Flush Flow Rate | 0–100 mL/min (adjustable) |
| Vial Volume | 40 mL |
| Brand | APL |
|---|---|
| Origin | Sichuan, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | APL-PTC100 |
| Instrument Type | Water & Soil VOC Analysis System |
| Sample Tray Capacity | 1 position |
| Injection Precision | RSD < 3% |
| Trap Temperature Range | –30 °C to 220 °C |
| Sample Heating Temperature Range | Ambient to 220 °C |
| Sample Vial Cooling Temperature | 20 °C |