Chromatography Accessories
Filter
Showing 181–210 of 437 results
| Brand | CoMetro |
|---|---|
| Model | CF-2 |
| Type | Liquid-phase Fraction Collector |
| Collection Modes | Time-based, Droplet-count-based |
| Max Capacity | 174 Tubes (12/13 mm) |
| Tube Switching Time | 0.35 s (for 12/13 mm tubes) |
| Operating Temperature | 0–40 °C |
| Power Supply | 115 VAC or 230 VAC, 50/60 Hz |
| Dimensions | 28 × 12 × 38 cm |
| Weight | 5 kg |
| Compliance | Designed for GLP-compliant chromatographic workflows |
| Brand | CoMetro |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Instrument Type | Liquid Chromatography Fraction Collector |
| Collection Mode | Volume-Based |
| Dimensions | 28 × 12 × 38 cm |
| Weight | 5 kg (11 lbs) |
| Operating Temperature | 0–40 °C |
| Power Supply | 115 VAC or 230 VAC, 50/60 Hz |
| Tube Switching Time | 0.35 s (for 12/13 mm tubes) |
| Collection Range | 1–9999 drops (1-drop increment) |
| Timer Range | 6 sec–999 min 59 sec (1-sec increment) |
| Max. Tube Capacity | 174 × 12/13 mm tubes (with standard rack) |
| Brand | CoMetro |
|---|---|
| Model | CF-2 |
| Type | Stepwise Fraction Collector |
| Collection Modes | Time-based, Drop-count-based, Volume-derived (via drop calibration) |
| Max Capacity | 174 tubes (12–13 mm diameter) or 42 flash vials (28 mm) |
| Tube Switching Time | ≤0.35 s (for 12/13 mm tubes) |
| Operating Temperature Range | 0–40 °C |
| Power Supply | 115 VAC or 230 VAC, 50/60 Hz |
| Dimensions | 28 × 12 × 38 cm |
| Weight | 5 kg |
| Construction | Anodized aluminum frame and stainless-steel components |
| Compliance | Designed for GLP-compliant chromatographic workflows |
| Brand | CoMetro |
|---|---|
| Model | CF-2 |
| Type | Mixed-Mode Fraction Collector |
| Collection Mode | Volume-Based |
| Dimensions | 28 × 12 × 38 cm |
| Weight | 5 kg (10 lbs) |
| Power Supply | 115 VAC or 230 VAC, 50/60 Hz |
| Operating Temperature | 0–40 °C |
| Droplet Count Range | 1–9999 (incremental by 1) |
| Time-Based Collection Range | 6 sec–999 min 59 sec (incremental by 1 sec) |
| Tube Switching Time | ≤0.35 sec (for 12/13 mm diameter tubes) |
| Max. Fraction Capacity | 174 tubes (with standard rack) |
| Construction | Anodized aluminum frame and stainless steel components |
| Compatibility | Integrates with UV detectors (e.g., Spectra/Chrom 280), peak fractionation modules, and multi-column systems via optional 4-column adapter |
| Brand | CoMetro |
|---|---|
| Model | CF-2 |
| Type | Mixed-Mode Fraction Collector |
| Collection Modes | Drop Count, Time, Optional Volume (via Flow Sensor Integration) |
| Max Capacity | 174 Tubes (12/13 mm) |
| Tube Switching Time | 0.35 s (for 12/13 mm tubes) |
| Operating Temperature | 0–40 °C |
| Power | 115 VAC or 230 VAC, 50/60 Hz |
| Power Consumption | <10 W |
| Dimensions | 28 × 12 × 38 cm |
| Weight | 5 kg (11 lb) |
| Compliance | CE-marked |
| Material | Anodized Aluminum Frame + Stainless Steel Components |
| Optional Accessories | 3-Way Split Valve (Cat. #124849), High-Flow 3-Way Valve (Cat. #124838), 2-Way Shut-Off Valve (Cat. #124848), 4-Column Adapter (Cat. #124876), Extension Mounting Bracket (Cat. #124874), Acrylic Dust Cover (Cat. #124858), Multiple Tube Rack Configurations (Cat. #124853–#124856) |
| Brand | CoMetro |
|---|---|
| Model | CF-2 |
| Type | Liquid-phase Fraction Collector |
| Collection Modes | Drop-count, Time-based, Volume-derived (via drop calibration) |
| Max Capacity | 174 tubes (12–13 mm diameter) |
| Tube Switching Time | ≤0.35 s (for 12/13 mm tubes) |
| Operating Temperature | 0–40 °C |
| Power Input | 115 VAC or 230 VAC, 50/60 Hz |
| Power Consumption | <10 W |
| Dimensions | 28 × 12 × 38 cm |
| Weight | 5 kg |
| Compliance | CE-marked |
| Brand | CoMetro |
|---|---|
| Model | CF-2 |
| Type | Mixed-Mode Fraction Collector |
| Collection Modes | Time-Based, Droplet-Count-Based, Volume-Based (via flow rate calibration) |
| Max Capacity | 174 tubes (12/13 mm diameter) or 42 flash vials (28 mm) |
| Tube Switching Time | ≤0.35 s (for 12/13 mm tubes) |
| Operating Temperature Range | 0–40 °C |
| Power Supply | 115 VAC or 230 VAC, 50/60 Hz |
| Power Consumption | <10 W |
| Dimensions (W×D×H) | 28 × 12 × 38 cm |
| Weight | 5 kg (11 lb) |
| Material | Anodized aluminum frame with stainless steel components |
| Compliance | Designed for GLP-compliant chromatographic workflows |
| Brand | CoMetro |
|---|---|
| Model | CF-2 |
| Type | Mixed-Mode Fraction Collector |
| Collection Modes | Time-based, Drop-count-based, Volume-derived (via drop calibration) |
| Max Capacity | 174 tubes (12/13 mm diameter) |
| Tube Switching Time | 0.35 s (for 12/13 mm tubes) |
| Operating Temperature | 0–40 °C |
| Power Input | 115 VAC or 230 VAC, 50/60 Hz |
| Dimensions | 28 × 12 × 38 cm |
| Weight | 5 kg |
| Construction | Anodized aluminum frame and stainless steel components |
| Compliance | Designed for GLP-compliant chromatographic workflows |
| Brand | CoMetro |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Model | CF-2 |
| Instrument Type | Mixed-Mode Fraction Collector |
| Collection Mode | Drop Counting |
| Dimensions | 28 × 12 × 38 cm |
| Weight | 5 kg (10 lbs) |
| Operating Temperature | 0–40 °C |
| Power Supply | 115 VAC or 230 VAC, 50/60 Hz |
| Drop Range | 1–9999 drops (increment: 1 drop) |
| Time Range | 6 sec–999 min 59 sec (increment: 1 sec) |
| Tube Switching Time | ≤0.35 sec (for 12/13 mm diameter tubes) |
| Tube Capacity | Up to 174 positions (with standard rack) |
| Compliance | CE-marked, RoHS-compliant, compatible with GLP/GMP workflows requiring audit-trail-capable chromatography systems |
| Brand | CoMetro |
|---|---|
| Origin | Imported |
| Model | COM 6000 |
| Temperature Range | Ambient + 5 °C to 150 °C |
| Derivatization Reagent Flow Rate | 0.001–5 mL/min or 0.01–10 mL/min |
| Reaction Flow Path | Full PEEK |
| Brand | CoMetro |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Model | COM 6000 Series |
| Temperature Control Range | ±1 °C (accuracy), ±0.4 °C (reproducibility), 20–150 °C (operating range) |
| Derivatization Solvent Flow Rate | 0.001–10 mL/min |
| Reaction Coil Volumes | 0.15 / 0.5 / 1.5 mL (user-selectable) |
| Flow Path Material | All-PEEK |
| Pressure Range | 0–4000 psi |
| Flow Accuracy | ±1% |
| Flow Precision | ≤0.2% RSD |
| Safety Cutoff Temperature | 160 °C |
| Warm-up Time to 150 °C | ≤30 min |
| Brand | CoMetro |
|---|---|
| Model | Com6000 Series |
| Temperature Range | Ambient +10 °C to 150 °C |
| Derivatization Reagent Flow Rate | 0.001–10 mL/min |
| Reaction Coil Material | PEEK |
| Reactor Volume Options | 0.15 / 0.5 / 1.5 mL |
| Temperature Accuracy | ±1 °C |
| Temperature Reproducibility | ±0.4 °C |
| Maximum Safety Cut-off | 160 °C |
| Pump Pressure Range | 0–4000 psi |
| Flow Accuracy | ±1% |
| Flow Precision | 0.2% RSD |
| System Fluidic Path | Full PEEK |
| Brand | CoMetro |
|---|---|
| Origin | Imported |
| Model | COM6000 |
| Temperature Range | Ambient +10 °C to 150 °C |
| Derivatization Reagent Flow Rate | 0.001–10 mL/min |
| Brand | CoMetro |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Model | COM6000 for Free Formaldehyde Analysis |
| Temperature Range | Up to 150 °C |
| Derivatization Reagent Flow Rate | 0.001–10 mL/min (standard operating range: 10 mL/min) |
| Reaction Coil | Full PEEK construction |
| Reaction Volume Options | 0.15 / 0.5 / 1.5 mL |
| Temperature Accuracy | ±1 °C |
| Temperature Reproducibility | ±0.4 °C |
| Pressure Range | 0–4000 psi |
| Flow Accuracy | ±1% |
| Flow Precision | 0.2% RSD |
| Brand | CoMetro |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Model | COM6000 |
| Temperature Range | Ambient +10 °C to 150 °C |
| Derivatization Reagent Flow Rate | 0.001–10 mL/min |
| Brand | CoMetro |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Model | Com6000 Series |
| Temperature Range | Ambient +10 °C to 150 °C |
| Derivatization Reagent Flow Rate | 0.001–10 mL/min |
| Reaction Loop Material | Full PEEK fluidic path |
| Brand | CoMetro |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Model | Com6000 Series |
| Temperature Range | 150 °C (max) |
| Derivatization Reagent Flow Rate | 0.001–10 mL/min |
| Reaction Coil Material | PEEK |
| Reaction Volume Options | 0.15 / 0.5 / 1.5 mL |
| Temperature Accuracy | ±1 °C |
| Temperature Reproducibility | ±0.4 °C |
| Pressure Range | 0–4000 psi |
| Flow Accuracy | ±1% |
| Flow Precision | 0.2% RSD |
| Brand | CoMetro |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Model | Com6000 Series |
| Temperature Range | RT+10°C to 150°C (Ready Indicator Activated Within 30 min at 150°C) |
| Derivatization Reagent Flow Rate | 0.001–10 mL/min |
| Reaction Coil Material | Full PEEK |
| Reaction Volume Options | 0.15 / 0.5 / 1.5 mL |
| Temperature Accuracy | ±1°C |
| Temperature Reproducibility | ±0.4°C |
| Max Safety Cut-off | 160°C |
| Flow Accuracy | ±1% |
| Flow Precision | 0.2% RSD |
| Pressure Range | 0–4000 PSI |
| Control Interface | Front-panel keypad + RS232 |
| Brand | CoMetro |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Model | CoMetro6000 |
| Temperature Range | Ambient +10 °C to 150 °C |
| Derivatization Reagent Flow Rate | 0.001–10 mL/min |
| Reaction Coil Material | Stainless Steel |
| Flow Path Material | PEEK |
| Temperature Accuracy | ±1 °C |
| Temperature Reproducibility | ±0.4 °C |
| Reaction Volume Options | 0.15 / 0.5 / 1.5 mL |
| Pressure Range | 0–4000 psi |
| Flow Accuracy | ±1% |
| Flow Precision | 0.2% RSD |
| Safety Cutoff Temperature | 160 °C |
| Warm-up Time to 150 °C | ≤30 min |
| Brand | CoMetro |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Instrument Type | Isocratic Pump |
| Max Pressure | 6000 psi |
| Flow Rate Range | 0.001–12 mL/min |
| Pump Head Configuration | Parallel Dual-Head |
| Flow Accuracy | ±1% |
| Flow Precision | ≤0.1% RSD |
| Pressure Units | psi, MPa, bar |
| Control Modes | Front-panel keypad, RS-232/USB PC interface, analog input (0–5 V / 4–20 mA) |
| Compressibility Compensation | Adjustable |
| Auto-Purge & Solvent Flush | Supported |
| Optional Multi-Pump Gradient Expansion | Up to 4 units |
| Brand | CoMetro |
|---|---|
| Model | CP050 / CP100 |
| Pump Type | Binary Isocratic HPLC Pump |
| Max Pressure | 6000 psi |
| Flow Rate Range | 0.001–12 mL/min |
| Flow Accuracy | ±1% |
| Flow Precision | 0.1% RSD |
| Pump Head Configuration | Parallel Dual Plunger Heads |
| Pressure Units | psi, MPa, bar |
| Control Modes | Front-panel Keypad, RS-232/USB PC Interface, Analog Input (0–5 V or 4–20 mA) |
| Compressibility Compensation | Adjustable |
| Auto-Purge & Solvent Flush | Yes |
| Seal & Plunger Self-Cleaning Function | Supported for Buffer Applications |
| Brand | CoMetro |
|---|---|
| Model | CP-M |
| Type | Isocratic High-Pressure Liquid Chromatography Pump |
| Max Pressure | 6000 psi |
| Flow Rate Range | 0.01–10 mL/min |
| Accuracy | ±2% |
| Precision | ≤0.2% RSD |
| Dimensions | 175(H) × 225(W) × 305(D) mm |
| Weight | 11 kg |
| Power Supply | 115/230 V, 50/60 Hz |
| Wetted Materials | PEEK or 316 Stainless Steel |
| Control Interface | Keypad & RS232 Digital Communication |
| Pressure Monitoring | Optional (CP-M3xx models) |
| Flow Stability | Pulse-free via Electronic Compensation and Low-Dead-Volume Accumulator |
| Brand | CoMetro |
|---|---|
| Model | CPT |
| Pump Type | Binary HPLC Pump |
| Max Pressure | 6000 psi (42 MPa) |
| Flow Rate Range | 0.001–5 mL/min |
| Temperature Control Range | +10°C to 120°C above ambient |
| Temperature Accuracy | ±0.5°C |
| Flow Accuracy | ±2% |
| Flow Precision | ≤0.2% RSD |
| Wetted Materials | 316L Stainless Steel |
| Interface | RS232, Analog Voltage/Frequency Input |
| Power Supply | 220 V, 50 Hz |
| Brand | CoMetro |
|---|---|
| Model | CP-M250 |
| Instrument Type | Binary Pump |
| Max Operating Pressure | 1500 psi |
| Flow Rate Range | 0.1–50 mL/min |
| Flow Accuracy | ±1% |
| Flow Precision | 0.2% RSD |
| Dimensions | 175(H) × 225(W) × 305(D) mm |
| Weight | 11 kg |
| Power Supply | 230 V / 115 V, 50 / 60 Hz |
| Fluid Path Materials | 316 Stainless Steel (standard) or PEEK (optional) |
| Control Interface | Keypad + RS232 digital communication |
| Remote Analog Input | 0–5 V or 4–20 mA |
| Compliance | Designed for GLP/GMP-aligned lab environments |
| Brand | CoMetro |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Instrument Type | Isocratic (Single-Solvent) High-Pressure Liquid Chromatography Pump |
| Maximum Pressure | 6000 psi (standard), up to 10,000 psi (customizable) |
| Flow Rate Range | 0.1–100 mL/min |
| Flow Accuracy | ±1% |
| Flow Precision | ≤0.1% RSD |
| Pump Head Configuration | Dual parallel piston heads |
| Wetted Materials | SS316L and PEEK options available |
| Compliance | Designed for GLP/GMP-aligned workflows and compatible with USP <1058> analytical instrument qualification practices |
| Brand | CoMetro |
|---|---|
| Model | CP100-LDI |
| Pump Type | Isocratic Binary-Compatible Dual-Head HPLC Pump |
| Max Pressure | 6000 psi |
| Flow Rate Range | 0.001–12 mL/min |
| Flow Accuracy | ±1% |
| Flow Precision | ≤0.1% RSD |
| Pump Head Configuration | Parallel Dual Plunger Heads |
| Pressure Units | psi / MPa / bar |
| Control Modes | Front-panel Keypad, RS-232/USB PC Interface, Analog Input (0–5 V or 4–20 mA) |
| Compressibility Compensation | Adjustable |
| Solvent Degassing & Purge | Integrated Low/High-Pressure Flush Function |
| Auto-Cleaning Mode | Available for Salt-Containing Mobile Phases |
| Compliance | Designed for GLP/GMP environments |
| Brand | CoMetro |
|---|---|
| Model | R1 |
| Type | Mixed-Mode Fraction Collector |
| Collection Principle | Volume-Based |
| Max Flow Rate | 100 mL/min |
| Dimensions (W×D×H) | 31 × 33 × 35.5 cm |
| Weight (excl. rack) | 7.7 kg |
| Power Supply | 115/230 VAC, 50/60 Hz |
| Tube Capacity | Up to 144 × 13 mm tubes (with optional 144-13 rack) |
| Collection Modes | Volume, Time, Drop, Peak Triggered |
| Valve Type | Solenoid-Actuated Switching Valve |
| Compliance | CE-marked architecture |
| Brand | CoMetro |
|---|---|
| Model | R1/R2 |
| Type | Mixed-Mode Fraction Collector |
| Collection Principle | Volume-Based, Drop-Counting, Time-Based, and Peak-Triggered |
| Max Flow Rate | 100 mL/min |
| Dimensions (R1) | 31 × 33 × 35.5 cm |
| Dimensions (R2) | 31 × 53 × 38 cm |
| Weight (R1, excl. rack) | 7.7 kg |
| Weight (R2, excl. rack) | 10.6 kg |
| Power Supply | 115 VAC or 230 VAC, 50/60 Hz |
| Tube Capacity Options | Up to 144 × 13 mm tubes, 100 × 16 mm tubes, 72 × 18 mm tubes, 36 × 25 mm tubes, 60 × 1.5 mL microcentrifuge tubes, 36 × 50 mL centrifuge tubes, or 96-well plates |
| Standard Configurations | R1 — single rack + valve |
| Brand | CoMetro |
|---|---|
| Model | R1/R2 Fraction Collector |
| Type | Mixed-Mode Fraction Collector |
| Collection Modes | Drop Counting, Time-Based, Volume-Based, Peak-Triggered |
| Max Flow Rate | 100 mL/min |
| Dimensions (R1) | 31 × 33 × 35.5 cm |
| Dimensions (R2) | 31 × 53 × 38 cm |
| Weight (R1, excl. rack) | 7.7 kg |
| Weight (R2, excl. rack) | 10.6 kg |
| Power Supply | 115 VAC or 230 VAC, 50/60 Hz |
| Tube Capacity Options | 144 × 12–13 mm tubes, 100 × 16 mm tubes, 72 × 18 mm tubes, 36 × 25 mm tubes, 60 × 1.5 mL microcentrifuge tubes, 36 × 50 mL centrifuge tubes, 96-well plate support |
| Safety Features | Leak Detection, Electrical Isolation Protection |
| Mounting | Optional instrument stand for space-efficient integration |
| Brand | CoMetro |
|---|---|
| Model | R1/R2 Fraction Collector |
| Type | Stepwise (Programmable) Fraction Collector |
| Collection Modes | Time-based, Drop-counting, Volume-based, Peak-triggered |
| Max Flow Rate | 100 mL/min |
| Dimensions (R1) | 31 × 33 × 35.5 cm |
| Dimensions (R2) | 31 × 53 × 38 cm |
| Weight (R1, w/o rack) | 7.7 kg |
| Weight (R2, w/o rack) | 10.6 kg |
| Power Supply | 115 VAC or 230 VAC, 50/60 Hz |
| Tube Rack Options | 144-12, 144-13, 100-16, 72-18, 36-25, 60-1.5, 36-50, 96-well plate compatible |
| Safety Features | Leak-proof design, electrical insulation protection |
| Mounting | Optional instrument stand for space optimization |
| Compliance | Designed for GLP-compliant laboratory environments |
