| Brand | Fortelab |
|---|---|
| Origin | Chongqing, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | CP300 |
| Price Range | USD 1,400 – 7,000 (based on current exchange rate) |
| Instrument Type | Secondary Thermal Desorber, Thermal Desorption Unit |
| Brand | Frontier |
|---|---|
| Origin | Japan |
| Model | EGA/PY3030D |
| Pyrolyzer Type | Microfurnace-based Tubular Pyrolyzer |
| Temperature Range | 10 °C above ambient to 1050 °C (0.1 °C resolution) |
| Heating Rate | Programmable up to 600 °C/min (8-step temperature program) |
| Hold Time & Pyrolysis Time | 0.1–999.9 min (0.1 min step) |
| Cooling | Liquid nitrogen or liquid air |
| Interface Temperature Control (ITF) | 40–450 °C (1 °C step) |
| Reproducibility | RSD < 2% (GC-FID, certified per ASTM D7260 and ISO 17253) |
| Application Modes | EGA, TD, Single-shot Py, TD/PY Double-shot, Heart-cut Release Gas Analysis |
| Sample Introduction Options | Liquid injector, Dual-shot injector, Thermal Desorption (TD) module, Derivatization reactor, UV-assisted pyrolysis injector |
| Brand | Fuli |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | FL1092C |
| Instrument Type | Gas Chromatography Autosampler |
| Maximum Sample Capacity | 150 positions (with optional extended sample tray) |
| Optional Modules | Integrated internal standard addition, programmable heating/stirring, barcode scanning, full-tray temperature control (via recirculating water bath) |
| Brand | Fuli |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Gas Chromatography Autosampler |
| Model | FL1092T |
| Sample Capacity | 16 vials per tray |
| Configuration Options | Single-tower or dual-tower operation |
| Module Options | Vial agitation, temperature control (cooling/heating), barcode scanning |
| Compliance | Designed for integration with GC systems compliant with ISO/IEC 17025 laboratory practices and compatible with FDA 21 CFR Part 11–enabled data acquisition software |
| Brand | Fuli |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Instrument Type | Dynamic Headspace Sampler |
| Automation Level | Fully Automated |
| Sample Tray Capacity | 24-position or 91-position |
| Heated Positions | 12 independent temperature-controlled vial positions |
| Sampling Modes | Static and Dynamic (with optional trap enrichment) |
| Electronic Pneumatic Control | Advanced AFC/EPC (Analog Flow Control / Electronic Pressure Control) |
| Equipped with Vial Agitation | Yes, programmable orbital shaking |
| Software Interface | Integrated intelligent workstation with method sequencing, audit trail, and GC trigger synchronization |
| Brand | Fulit |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Manufacturer |
| Product Category | Domestic |
| Model | PT800 |
| Instrument Type | Multifunctional Autosampler |
| Flow Control Precision | ±0.001 psi (EPC) |
| Sample Capacity | 96-position water/soil dual-mode autosampler |
| Trapping System | High-efficiency U-shaped trap with integrated spiral water removal |
| Sample Preservation | Optional refrigerated sample tray (4–10 °C) |
| System Inertness | Fully passivated flow path (inertized valves, tubing, and fittings) |
| Cleaning Protocol | Hot water and methanol purge cycles |
| Stirring | Integrated magnetic stirring for soil matrix enhancement |
| Software Interface | Modular workstation with guided workflow buttons |
| Compliance Support | Audit-trail ready |
| Brand | Fulu |
|---|---|
| Origin | Russia |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | TDA |
| Instrument Type | Two-Stage Thermal Desorber / Thermal Desorption Unit |
| Sample Capacity | 50-position Auto-sampler |
| Sample Tube Format | US Standard Adsorption Tubes (89 mm × OD 6.4 mm) |
| Temperature Control Range | –20 °C to 450 °C |
| Cold Trap Heating Rate | Up to 3000 °C/min |
| Carrier Gas Control | Full Electronic Pressure Control (EPC) |
| System Liner | Fully Inert Flow Path |
| Peak Area Repeatability | RSD ≤ 2% |
| Operating Interface | Integrated Touchscreen Display |
| Functional Modes | Analysis, Tube Conditioning (Aging), Cold Trap Cleaning, Cold Trap Performance Test |
| Cooling Method | Thermoelectric (No Liquid Nitrogen Required) |
| Brand | GERSTEL |
|---|---|
| Origin | Germany |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | PYRO |
| Instrument Type | Filament-Based Pyrolyzer |
| Temperature Range | 10–1000 °C |
| Heating Technology | Four-Point Resistance Measurement on Platinum Filament |
| Sample Introduction | Valveless, Transfer-Line-Free Direct Coupling to GC/MS |
| Optional Cryogenic Trapping | Compatible with CIS (Cold Injection System) for Dual-Stage Thermal Desorption |
| Automation | Fully Integrated with MPS Robotic Sample Handling Platform |
| Compliance | Designed for GLP/GMP environments |
| Brand | Tianjin HengAo |
|---|---|
| Origin | Tianjin, China |
| Manufacturer Type | Direct Manufacturer |
| Model | HT-230A |
| Temperature Control Range | Ambient +5°C to 80°C |
| Cooling | None (Heating-Only) |
| Control Accuracy | ±0.1°C |
| Heating Technology | TPC & Thin-Film Heater |
| Controller | Imported PID Digital Temperature Controller |
| Safety Features | Over-Temperature Alarm, Open-Circuit Protection |
| Mounting | Modular Side-Mount Design for HPLC Stacks |
| Orientation | Vertical or Horizontal Installation |
| Port Configuration | Inlet/Outlet Ports on Top, Bottom, Left, and Right |
| Brand | Hengxi Instruments |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | HS-951A |
| Instrument Type | Static Headspace Sampler |
| Automation Level | Fully Automated |
| Oven Temperature Range | Ambient to 260 °C |
| Valve Temperature Range | Ambient to 220 °C |
| Sample Transfer Line Temperature Range | Ambient to 220 °C |
| Temperature Control Accuracy | < ±0.1 °C |
| Temperature Uniformity | < ±0.1 °C |
| Sample Position Capacity | 12 vials |
| Vial Format | Standard 20 mL (10 mL optional) |
| Loop Volume | 1 mL |
| Pressurization Range | 0–0.4 MPa (continuously adjustable) |
| Pressure Monitoring Range | 0–0.4 MPa (digital gauge) |
| RSD for Repeatability | < 1.5% (200 ppm ethanol in water, GC-dependent) |
| Power Supply | AC 220 V, 50 Hz |
| Power Consumption | 450 W |
| Dimensions (W×D×H) | 505 × 295 × 535 mm |
| Weight | ~32 kg |
| Brand | HMC |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | PHRED |
| Price Range | USD 1,400–2,800 (FOB) |
| Operating Temperature | Ambient |
| Derivatization Flow Rate | 0.3 mL/min |
| Reaction Capillary ID | 0.25 mm |
| Dimensions (L×W×H) | 330 × 50 × 70 mm |
| Power Supply | 220 V / 50 Hz |
| Power Consumption | 8 W |
| Capillary Material | PTFE |
| Maximum Pressure Rating | 500 psi (35 bar) |
| Weight | ~4 kg |
| Regulatory Compliance | AOAC 2005.08, AOAC 2008.02, AOAC Aa 11-05, Taiwan Food Agency Notice No. 0981800370, Ph. Eur. 2.8.18, GB/T 18979–2003, SN/T 1109–2002 |
| Brand | HTA |
|---|---|
| Origin | Italy |
| Model | HT4150L |
| Instrument Type | Multifunctional Autosampler |
| Max Sample Capacity | 32 tubes (2 × 16-position racks) |
| Minimum Dispensing Volume | 0.1 mL |
| Quantitative Loop Volumes | 1 mL and 2.5 mL |
| Positioning Accuracy | < 0.2 mm |
| Motion Architecture | XYZ three-axis robotic arm |
| Needle Wash | Internal and external wall rinsing |
| Repeat Injection Capability | Unlimited cycles |
| Brand | HUANKONG |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Model | APK1200 |
| Temperature Range | Ambient to 400 °C |
| Gas Flow Rate | 200 mL/min |
| Tube Capacity | 20 tubes |
| Compliance | HJ 644–2013, HJ 734–2014, HJ 583–2010 |
| Brand | Huapaikeyi |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Product Origin | Domestic (China) |
| Model | HS10A |
| Temperature Range | +5–150 °C |
| Derivatization Reagent Flow Rate | 0–5 mL/min |
| Reaction Capillary | Stainless Steel, 10 m × 0.2 mm ID |
| Brand | HuaShengPuXin (HSPX) |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Two-Stage Thermal Desorber |
| Automation Level | Fully Automated |
| Desorption Temperature Range | Ambient to 400 °C |
| Valve Injection Zone Temperature Range | Ambient to 220 °C |
| Transfer Line Temperature Range | Ambient to 240 °C |
| Cold Trap Temperature Range | −35 °C to Ambient |
| Temperature Control Accuracy | ±0.1 °C |
| Analyte Recovery Rate | >98% (compound-dependent) |
| Sample Capacity | ≥10 positions |
| Brand | Huayisanpu |
|---|---|
| Origin | Beijing, China |
| Model | PTC-100 |
| Sample Capacity | 100-position carousel |
| Injection Precision | RSD < 2.5% (GC-dependent) |
| Trap Temperature Range | Ambient to 380 °C |
| Purge Heating Temperature | Ambient to 250 °C |
| Sample Chilling Temperature | 4–10 °C |
| Cold Trap Temperature | Ambient to −40 °C |
| Water Removal Trap Temperature | Ambient to −30 °C |
| Desorption Ramp Rate | >2000 °C/min (low-voltage controlled) |
| Purge Flow Control | 0–100 mL/min, adjustable with digital readout |
| Carrier Gas Pressure Regulation | 0–0.4 MPa |
| Programmable External Events | 15 independent time-controlled functions (0.1–99 min, timing accuracy <0.1%) |
| Sample Vial Format | Standard 40 mL vials |
| System Dimensions | 580 × 640 × 850 mm (H×W×D) |
| Weight | ~50 kg |
| Power Consumption | <1000 VA |
| Interlock Signal Latency | <2 s |
| Brand | Huayisanpu |
|---|---|
| Origin | Beijing, China |
| Model | TDS-3410 |
| Temperature Range | Ambient to 400 °C |
| Gas Flow Rate | 10–250 mL/min |
| Tube Capacity | 12 tubes |
| Temperature Control Resolution | 1 °C |
| Temperature Accuracy | ±0.5% of setpoint |
| Timer Range | 0–655 min |
| Power Consumption | <500 W |
| Dimensions (W×D×H) | 170×390×400 mm |
| Weight | ~8 kg |
| Brand | Instrumax |
|---|---|
| Origin | Tianjin, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | CADetector a1 |
| Price Range | USD 42,000 – 49,000 (FOB Tianjin) |
| Compatible Systems | HPLC, UPLC, SFC |
| Detector Type | Charged Aerosol Detector (CAD), classified as a universal mass-sensitive detector distinct from ELSD |
| Brand | Instrumax |
|---|---|
| Origin | Tianjin, China |
| Manufacturer Type | OEM Manufacturer |
| Instrument Type | Quaternary Solvent Delivery Pump |
| Max Pressure | 10000 psi |
| Flow Rate Range | 0.01–5 mL/min |
| Flow Accuracy | ±0.2% RSD |
| Flow Precision | ≤0.2% RSD |
| Brand | ISCO |
|---|---|
| Model | R1/R2 |
| Instrument Type | Liquid-Phase Fraction Collector |
| Collection Modes | Volume-, Time-, Drop-, and Peak-Triggered |
| Maximum Flow Rate | 100 mL/min |
| Dimensions (R1) | 31 × 33 × 35.5 cm |
| Dimensions (R2) | 31 × 53 × 38 cm |
| Weight (R1, without rack) | 7.7 kg |
| Weight (R2, without rack) | 10.6 kg |
| Power Supply | 115 VAC or 230 VAC, 50/60 Hz |
| Tube Rack Options | 144-12, 144-13, 100-16, 72-18, 36-25, 60-1.5, 36-50, 96-well plate compatible |
| Safety Features | Leak detection, electrical insulation protection |
| Mounting | Optional instrument stand for space optimization |
| Brand | Jiapeng |
|---|---|
| Model | BS-100A |
| Type | Liquid-phase Fraction Collector |
| Collection Mode | Time-based |
| Tube Capacity | 100 × 12 mL |
| Timing Range | 1 s – 24 h (adjustable in 1-s increments) |
| Power Supply | AC 220 V, 50/60 Hz |
| Dimensions (W×D×H) | 265 × 390 × 390 mm |
| Weight | 8.35 kg |
| Data Retention After Power Loss | ≥10 years |
| Display | Large Blue-backlit Chinese LCD with Menu-driven Interface |
| Housing Material | ABS Plastic (Injection-molded, Closed-loop Design) |
| Panel Angle | 35° Ergonomic Tilt |
| Tube Rack | Circular, Digitally Labeled (1–100), Interchangeable with Standard 12-mL Tube Formats |
| Valve Type | Keebio Fluid Shut-off Solenoid Valve |
| Compatibility | External Trigger via RS-232 COM Port (for Synchronization with Peristaltic Pumps) |
| Brand | Kezhe / KEZHE SHANGHAI |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | ELSD-2000KS |
| Instrument Type | Evaporative Light Scattering Detector (ELSD) |
| Wavelength Range | 195–600 nm |
| Detection Method | Dual-beam |
| Light Source | Xenon lamp |
| Laser Wavelength (Standard) | 650 nm |
| Gas Flow Range | 0–5 L/min |
| Nebulization Pressure | 0–100 psi |
| Temperature Control Range | Ambient to 150 °C (±1 °C resolution) |
| Mobile Phase Flow Rate Compatibility | 0–5 mL/min |
| Detector | Imported large-area silicon photodiode |
| Power Supply | 220 V AC |
| Compatible Carrier Gases | Compressed air or nitrogen |
| Core Components | Stainless-steel evaporation tube, maintenance-free stainless-steel nozzle, laser source, photodetector, dedicated ELSD-2000KS chromatography workstation |
| Brand | Kezhe / KEZHE SHANGHAI |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | ELSD-3000KS |
| Instrument Type | Evaporative Light Scattering Detector (ELSD) |
| Wavelength Range | 195–600 nm |
| Detection Method | Dual-beam |
| Light Source | Xenon Lamp |
| Brand | Kezhe / KEZHE SHANGHAI |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Evaporative Light Scattering Detector (ELSD) |
| Wavelength Range | 195–600 nm |
| Detection Mode | Dual-Beam |
| Light Source | Xenon Lamp |
| Gas Flow Range | 0–5 L/min |
| Nebulizer Pressure | 0–100 psi |
| Temperature Control Range | Ambient to 150 °C (±1 °C resolution) |
| Mobile Phase Flow Rate Compatibility | 0–0.5 mL/min |
| Light Source (Standard) | 650 nm Laser |
| Detector | Imported Photomultiplier Tube (PMT) |
| Power Supply | 220 V AC |
| Compatible Carrier Gases | Compressed Air or Nitrogen |
| Brand | KEZHE SHANGHAI |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Fluorescence Detector (FD) |
| Wavelength Range | 195–650 nm (Excitation), 200–800 nm (Emission) |
| Measurement Mode | Dual-Beam |
| Light Source | Xenon Lamp |
| Flow Rate Range | 0–10 mL/min |
| Flow Accuracy | ±0.3% |
| Flow Precision (RSD) | ≤0.1% |
| Injection Valve Pressure Rating | 35.0 MPa (5000 psi) |
| Spectral Bandwidth | 10 nm / 20 nm |
| AD Resolution | 24-bit |
| Software Platform | FStar-2000 Chromatography Data System (CDS) for Windows 7/8/10 |
| Compliance | Fully aligned with Chinese Pharmacopoeia (2015 Edition), GLP/GMP principles, and FDA 21 CFR Part 11 audit trail requirements |
| Brand | Kezhe Shanghai |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | KH-FL20E |
| Instrument Type | Fluorescence Detector (FD) |
| Excitation Wavelength Range | 190–800 nm |
| Emission Wavelength Range | 190–800 nm |
| Spectral Bandwidth Options | 2 / 5 / 10 / 20 nm |
| Wavelength Accuracy | ±0.2 nm |
| Wavelength Precision | ±1 nm |
| Light Source | Solid-State Discharge Lamp |
| Monochromator | 1200-line Holographic Grating |
| Detector | Photomultiplier Tube (PMT) |
| AD/DA Resolution | 24-bit |
| Temperature Control Range (Flow Cell) | Ambient to 50 °C |
| Compliance | Meets GMP/GLP requirements |
| Brand | Kezhe Shanghai |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | KH-FL30E |
| Instrument Type | Fluorescence Detector (FD) |
| Wavelength Range | 190–900 nm (Excitation & Emission) |
| Measurement Mode | Dual-Beam |
| Light Source | 150 W DC Xenon Lamp |
| Spectral Bandwidth | 10 nm / 15 nm |
| Wavelength Accuracy | ±0.2 nm |
| Wavelength Precision | ±1 nm |
| Monochromator | 1200-line Holographic Grating |
| Detector | Photomultiplier Tube (PMT) |
| AD/DA Resolution | 24-bit |
| Temperature Control Range (Flow Cell) | Ambient to 50 °C |
| Software | FM-2000 Chromatography Workstation |
| Compliance | Chinese Pharmacopoeia (2010 & 2015 Editions), GLP/GMP-ready, LIMS-compatible, FDA 21 CFR Part 11 support (audit trail & electronic signature enabled) |
| Brand | Kezhe Shanghai |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | KH-FL30Plus |
| Instrument Type | Fluorescence Detector (FD) |
| Wavelength Range | 190–900 nm (Excitation & Emission) |
| Wavelength Accuracy | ±0.2 nm |
| Wavelength Precision | ±1 nm |
| Spectral Bandwidth | 10 nm / 15 nm |
| Light Source | 150 W DC Xenon Lamp |
| Monochromator | 1200-line Holographic Grating |
| Detector | Photomultiplier Tube (PMT) |
| AD/DA Resolution | 24-bit |
| Temperature Control Range | Ambient to 50 °C (Optional) |
| Compliance | Chinese Pharmacopoeia 2010/2015 Edition, GLP/GMP-Ready, LIMS-Compatible |
| Brand | Kezhe Shanghai |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Model | KH-FL50E |
| Instrument Type | Fluorescence Detector (FD) |
| Excitation/Emission Wavelength Range | 190–900 nm |
| Detection Modes | Fluorescence, Phosphorescence, Chemiluminescence |
| Light Source | 150 W DC Xenon Lamp or 5 W Pulsed Xenon Lamp |
| Monochromator | 1200-line Holographic Grating |
| Spectral Bandwidth (Excitation & Emission) | 5/10/15/20 nm selectable |
| Wavelength Accuracy | ±0.2 nm |
| Wavelength Precision | ±1 nm |
| AD/DA Resolution | 24-bit |
| Flow Cell Temperature Control | 5–50 °C |
| Detector Options | Single-Photon Counting Module (SPCM) or Variable-Voltage High-Sensitivity PMT |
| Compliance | Chinese Pharmacopoeia 2010/2015, GLP/GMP-ready, LIMS-compatible |
| Brand | KEZHE SHANGHAI |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Evaporative Light Scattering Detector (ELSD) |
| Model | ELSD-5000KS |
| Wavelength Range | 200–800 nm (standard), optional 200–400 nm or 200–1100 nm |
| Detection Mode | Dual-beam |
| Light Source | Standard 650 nm laser + D₂/W lamp combination |
| Nebulizer Gas Flow | 0–5 L/min |
| Nebulizer Pressure | 0–150 psi |
| Drift Tube Temperature | Ambient to 200 °C (1 °C resolution) |
| Mobile Phase Flow Rate | 0–200 mL/min |
| Fraction Capacity | 160 positions |
| Collection Mechanism | X-Y-Z three-axis robotic arm |
| Gas Supply | Compressed air or nitrogen |
| Software | ELSD-5000KS Preparative Chromatography Workstation |