Chromatography Instruments
Filter
Showing 1–30 of 662 results
| Brand | 3i |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | 1/16″ OD × 0.3 mm ID |
| Material Grades | ASTM A213/A269/A312-compliant TP304, TP321, TP316L, TP304L, Monel 400, Inconel 600 |
| Outer Diameter Tolerance | ±0.1 mm |
| Wall Thickness Tolerance | ±0.1 mm |
| Max Length per Coil | 1000 m |
| Surface Finish | Electropolished (optional) |
| Pressure Rating | Up to 900 psi (6.2 MPa) at 25°C |
| Temperature Range | –200°C to +450°C (dependent on grade and configuration) |
| Packaging | Anti-vibration, dust-proof, abrasion-resistant coil packaging |
| Brand | 3i |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | 6×1 mm (OD×Wall) |
| Instrument Type | Laboratory Gas Chromatograph Accessory |
| Application Scope | General-Purpose GC Fluidic Path |
| Material Grades | ASTM TP304, TP321, TP316L, TP304L, Monel 400, Inconel 600 |
| Standards Compliance | ASTM A269, A213, ASME SA-312 |
| Outer Diameter Range | 1–25 mm |
| Wall Thickness Range | 0.4–2.1 mm |
| Tolerance | ±0.05 mm (OD and WT) |
| Delivery Condition | Annealed & Soft |
| Surface Finish | Bright-Annealed |
| Maximum Coil Length | ≤1000 m per spool |
| Packaging | Vibration- and abrasion-resistant |
| Brand | AB SCIEX |
|---|---|
| Origin | Netherlands |
| Model | EKSPERT CHIPLC nanoLC 425 |
| Type | Nano-flow Liquid Chromatography System |
| Configuration | Used (Refurbished & Verified) |
| Intended Use | Analytical-scale and nano-scale LC separation for proteomics, metabolomics, and biomarker discovery |
| Brand | AB SCIEX |
|---|---|
| Origin | Singapore |
| Model | ekspert nanoLC 400 |
| Instrument Type | Nano-flow Liquid Chromatography System |
| Configuration | Pre-owned (Refurbished & Functionally Verified) |
| Flow Rate Range | 50 nL/min – 20 µL/min |
| Column Compatibility | 50–150 µm ID capillary columns |
| Detection Interface | ESI-compatible, designed for coupling with mass spectrometers (e.g., AB SCIEX TripleTOF®, QTRAP® systems) |
| Operating Software | ekspert microLC / nanoLC Control v3.x or later |
| Compliance | Designed to support GLP/GMP workflows with audit-trail-capable software options |
| Brand | AB SCIEX |
|---|---|
| Origin | USA |
| Model | M3 MicroLC |
| Configuration | Refurbished Unit |
| Category | Microflow Liquid Chromatography System |
| Intended Use | Coupled with Mass Spectrometry (MS) for High-Sensitivity Bioanalysis |
| Brand | Acchrom-Tech |
|---|---|
| Origin | Liaoning, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Country of Origin | China |
| Model | PAH Analysis System |
| Instrument Type | Dedicated High-Performance Liquid Chromatography (HPLC) System |
| Application Scope | Specialized for Polycyclic Aromatic Hydrocarbons (PAHs) in Environmental Matrices |
| Configuration | Online Solid-Phase Extraction (SPE) coupled with HPLC and Fluorescence Detection (FLD) |
| Optional Upgrade Path | Online SPE–LC–MS/MS Interface Module |
| Brand | Acchrom-Tech |
|---|---|
| Origin | Liaoning, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Country of Origin | China |
| Model | S3000 |
| Instrument Type | Conventional HPLC System |
| Application Scope | General-Purpose Analytical HPLC |
| Brand | Acchrom-Tech |
|---|---|
| Origin | Liaoning, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Country of Origin | China |
| Model | S6000 Comprehensive 2D-LC System |
| Instrument Type | Conventional High-Performance Liquid Chromatograph (HPLC) |
| Application Scope | General-purpose complex matrix analysis |
| Regulatory Compliance | Supports GB 5009.296–2023 and GB 5009.82–2016 for fat-soluble vitamins |
| Brand | Acchrom-Tech |
|---|---|
| Origin | Liaoning, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic HPLC System |
| Model | S6000 |
| Instrument Type | Conventional High-Performance Liquid Chromatograph |
| Application Scope | General-Purpose Analytical HPLC |
| Flow Rate Range | 0.001–10.000 mL/min |
| Maximum Operating Pressure | 45 MPa / 62 MPa |
| Injection Volume | 100 µL (expandable to 1000 µL) |
| Data Acquisition Frequency | 160 Hz |
| Brand | Acchrom-Tech |
|---|---|
| Origin | Liaoning, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Country of Origin | China |
| Model | S6000 Online SPE–2D-LC System |
| Instrument Category | Conventional High-Performance Liquid Chromatograph (HPLC) |
| Application Scope | General-purpose analytical platform for complex matrix samples |
| Brand | Acchrom-Tech |
|---|---|
| Origin | Liaoning, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic HPLC System |
| Model | S6000PLUS |
| Instrument Type | Conventional High-Performance Liquid Chromatograph |
| Application Scope | General-Purpose Analytical HPLC |
| Pump Configuration | Binary High-Pressure Gradient or Quaternary Low-Pressure Gradient Optional |
| Max Operating Pressure | 70 MPa |
| Flow Rate Range | 0.001–10.000 mL/min |
| Injection Volume | 0.1–30 µL (expandable to 100 µL) |
| Autosampler Capacity | 120 × 2 mL vials or 96-well microplate |
| Autosampler Temperature Control | 1–45 °C (Peltier-based, ±0.3 °C stability) |
| Column Oven Temperature Range | 1–90 °C (Peltier heating/cooling, ±0.1 °C uniformity) |
| Detector Options | UV, DAD (1024-pixel diode array), FLR, RI, ELS |
| DAD Specifications | Built-in Hg lamp wavelength calibration, 160 Hz acquisition rate, multi-channel reference background fitting, user-defined reference wavelengths per channel |
| Sample Carryover | <0.003% |
| Column Compatibility | Up to 300 mm length, ≥2.5 µm particle size columns |
| Integrated Column Switching Valve | Optional internal valve with up to 6-position configuration |
| Brand | Acchrom-Tech |
|---|---|
| Origin | Liaoning, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Instrument Type | Ultra-High-Performance Liquid Chromatograph |
| Maximum Operating Pressure | 150 MPa |
| Sample Capacity | 162 × 2 mL vials + 4 × 4 mL vials |
| Column Oven Temperature Range | 1.0–90.0 °C (0.1 °C resolution) |
| UV-Vis Detection Wavelength Range | 190–900 nm |
| Data Acquisition Rate | 500 Hz |
| Detector Options | UV-Vis, Diode Array (DAD), Fluorescence (FLR), Refractive Index (RI), Evaporative Light Scattering (ELS) |
| Brand | Advion Interchim Scientific |
|---|---|
| Origin | USA |
| Distributor Type | Authorized Distributor |
| Import Status | Imported |
| Model | Plate Express TLC |
| Operation Mode | Automated |
| Desolvation | Nitrogen Purge |
| Sample Platform | Adjustable for Standard TLC Plates (e.g., 20 × 20 cm, 10 × 20 cm, 5 × 10 cm) |
| Compatibility | Designed for Integration with Expression® CMS Compact Mass Spectrometer |
| Brand | Advion Interchim Scientific |
|---|---|
| Origin | France |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model | puriFlash 5.015-XL |
| Application Level | Industrial-Scale Preparative |
| Instrument Type | Medium-Low Pressure Preparative Liquid Chromatography |
| Flow Rate Range | 0–825 mL/min |
| Maximum Operating Pressure | 15 bar |
| UV Detection Wavelength Range | 200–800 nm |
| Brand | Advion Interchim Scientific |
|---|---|
| Origin | France |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | puriFlash 5.020 |
| Application Level | Laboratory Grade |
| Instrument Type | Medium- to Low-Pressure Preparative LC |
| Flow Rate Range | 0–300 mL/min |
| Maximum Operating Pressure | 20 bar |
| UV Wavelength Range | 200–800 nm (with optional extended UV pack) |
| Data Acquisition Rate | 1 Hz (not amu — corrected per instrument context) |
| Brand | Advion Interchim Scientific |
|---|---|
| Origin | France |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model | puriFlash 5.050 |
| Application Level | Laboratory-Scale |
| Instrument Type | Medium-Low Pressure Preparative LC |
| Flow Rate Range | 0–250 mL/min |
| Maximum Operating Pressure | 50 bar |
| UV Detection Wavelength Range | 200–800 nm |
| Brand | Advion Interchim Scientific |
|---|---|
| Origin | France |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model | puriFlash 5.250 |
| Instrument Type | High-Pressure Preparative LC System |
| Flow Rate Range | 0.1–250 mL/min |
| Maximum Operating Pressure | 250 bar |
| UV-Vis Wavelength Range | 200–800 nm |
| Application Level | Laboratory-Scale to Pilot-Scale Purification |
| Brand | Advion Interchim Scientific |
|---|---|
| Origin | France |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | puriFlash 5.250P |
| Application Level | Laboratory-Scale |
| Instrument Type | High-Pressure Preparative Liquid Chromatography |
| Flow Rate Range | 0.1–125 mL/min |
| Maximum Operating Pressure | 250 bar |
| UV Wavelength Range | 200–800 nm |
| Detection Cell | 1.3 mm pathlength, 55 µL volume |
| Gradient Capability | Quaternary solvent delivery with automated degassing |
| Column Compatibility | Up to 60 mm internal diameter |
| Fraction Collection | 132-position rack (18 × 150 mm tubes, configurable) |
| Control Interface | 15″ HD capacitive touchscreen |
| Software Platform | InterSoft X Genius (KISS-compliant, drag-and-drop gradient editor, method automation, audit-trail-ready) |
| Brand | Advion Interchim Scientific |
|---|---|
| Origin | France |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | puriFlash 5.400 |
| Flow Rate Range | 0–125 mL/min |
| Maximum Pressure | 400 bar |
| Wavelength Range | 200–800 nm |
| Wavelength Reproducibility | ±0.5 nm |
| Detection Channels | Dual-wavelength (UV-Vis) with full-spectrum acquisition capability |
| Column ID Support | Up to 60 mm |
| Sample Capacity | 132-tube rack (18 × 150 mm), configurable for alternative formats |
| Touchscreen Interface | 15-inch HD capacitive touchscreen |
| Gradient Capability | Quaternary solvent delivery |
| Injection Modes | Liquid injection and dry-load (Load&Go) via 6-port + 10-port valve manifold |
| Flow Cell | 1.0 mm pathlength, 20 µL volume |
| Compliance | Designed for GLP-compliant workflow execution |
| Brand | Advion Interchim Scientific |
|---|---|
| Origin | France |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model | puriFlash 535-XL |
| Application Level | Industrial-Scale Preparative |
| Instrument Type | Medium-Low Pressure Preparative LC |
| Flow Rate Range | 0–400 mL/min |
| Maximum Operating Pressure | 35 bar |
| UV Detection Wavelength Range | 200–800 nm |
| Brand | Advion Interchim Scientific |
|---|---|
| Origin | France |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model | puriFlash XS 520plus |
| Application Level | Laboratory Grade |
| Instrument Type | Medium- to Low-Pressure Preparative LC |
| Flow Rate Range | 0.1–300 mL/min |
| Maximum Operating Pressure | 20 bar |
| Column ID Compatibility | Up to 80 mm |
| Typical Prep Scale | 4–800 g |
| Detector Options | UV/Vis, iELSD, Mass Spectrometry (MS) Interface Capable |
| Software Platform | InterSoft X |
| Brand | AECS |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | LabPrep |
| Pricing | Upon Request |
| Brand | AECS |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | PrepPlus |
| Pricing | Upon Request |
| Brand | AECS |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | QuickPrep |
| Pricing | Upon Request |
| Brand | AES |
|---|---|
| Origin | Canada |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | CEInfinite |
| Voltage Input | 100/240 VAC, 50–60 Hz |
| Cooling Method | Liquid-based Thermostatic Control |
| Sample Temperature Range | 4–10 °C |
| Detector | Scientific CMOS (sCMOS) Imaging Sensor |
| Separation Mode | Voltage Gradient iCIEF |
| Sample Introduction | Automated Capillary Injection |
| Brand | AGC |
|---|---|
| Origin | Ireland |
| Model | AGC 600DID |
| Instrument Type | Laboratory Gas Chromatograph |
| Application | Ultra-High-Purity (UHP) Gas Analysis |
| Oven Temperature Range | 5°C above ambient to 450°C |
| Oven Ramp Rate | 0.1–40°C/min (0.1°C increments) |
| Oven Cool-Down | 300°C to 50°C in ≤5 min |
| Carrier Gas Flow Control Range | 0–500 mL/min |
| Carrier Gas Pressure Control Range | 0–900 kPa |
| Injector Maximum Temperature | 450°C |
| Injector Pressure Setting Range | 0–700 kPa |
| Injector Total Flow Setting Range | 10–500 mL/min |
| Brand | AGC |
|---|---|
| Origin | Ireland |
| Model | AGC NC1000 |
| Instrument Type | Laboratory Gas Chromatograph |
| Application | Ultra-High-Purity Semiconductor Gas Analysis |
| Temperature Control Range | 0–300 °C |
| Ramp Rate | 0.1–40 °C/min (0.1 °C increment) |
| Cool-down Time | ~5 min (300 °C → 50 °C) |
| Carrier Gas Flow Range | 0–900 mL/min |
| Carrier Gas Pressure Range | 0–700 kPa |
| Injector Max Temp | 450 °C |
| Injector Pressure Setpoint Range | 0–700 kPa |
| Injector Total Flow Setpoint Range | 0–500 mL/min |
| Detector | Pulsed Helium Discharge Ionization Detector (DID) |
| Detection Range | ppb to % level |
| Accuracy | ±1% of full scale |
| Response Time (90%) | 0.5 s |
| Warm-up Time | 60 min |
| Display | 6.5″ color LCD with resistive touchscreen |
| Dimensions (W×H×D) | 483 mm × 219 mm × 564 mm (19″ rack-mount, 5U) |
| Weight | 25 kg |
| Carrier Gas | Ultra-high-purity helium (N6.0, 20–60 mL/min) |
| Sample Flow | 10–500 mL/min (recommended: 200 mL/min) |
| Drive Gas | Dry, oil-free air at 300 kPa |
| Electronic Pressure/Flow Control | 0–5 bar output (5–10 bar input) |
| Output Signals | 0–1 V analog |
| Compliance | Designed for ASTM D7527, ISO 8573-5, IEC 61511, and aligned with USP <621>, FDA 21 CFR Part 11 data integrity requirements for electronic records |
| Brand | AGC |
|---|---|
| Origin | Ireland |
| Model | NovaCHROM 1000 |
| Instrument Type | Online Gas Chromatograph |
| Application | High-Purity Gas Impurity Analysis |
| Oven Temperature Range | 4 °C to 450 °C |
| Temperature Stability | < ±0.05 °C/h (after 30 min warm-up) |
| Cooling Rate | 300 °C to 50 °C in ~5 min |
| Carrier Gas Flow Control Range | 0–500 mL/min |
| Carrier Gas Pressure Control Range | 0–900 kPa |
| Injector Max Temperature | 300 °C |
| Injector Pressure Setting Range | 0–700 kPa |
| Injector Total Flow Setting Range | 10–500 mL/min |
| Brand | AGC |
|---|---|
| Origin | Ireland |
| Model | NovaCHROM 1000 DID |
| Instrument Type | Laboratory Gas Chromatograph |
| Application | Dedicated to High-Purity Hydrogen Analysis |
| Temperature Control Range | +5 °C to 450 °C |
| Oven Ramp Rate | 0.1–40 °C/min (0.1 °C increments) |
| Cool-down Time | ~5 min (300 °C to 50 °C) |
| Carrier Gas Flow Range & Control | 0–500 mL/min |
| Carrier Gas Pressure Range & Control | 0–700 kPa |
| Injector Maximum Operating Temperature | 450 °C |
| Injector Pressure Setpoint Range | 0–700 kPa |
| Injector Total Flow Setpoint Range | 10–500 mL/min |
| Detector | Helium Ionization Detector (DID) |
| DID Measurement Range | ppb to % level |
| DID Accuracy | ±1% of full-scale reading |
| DID Operating Temperature | 30–45 °C |
| Ambient Operating Temperature | 10–30 °C |
| DID Response Time (90%) | 0.5 s |
| DID Warm-up Time | 60 min |
| Display | 6.5″ color LCD with LED backlight and resistive touchscreen |
| Carrier Gas | Ultra-high-purity helium (He, N6.0), 20–60 mL/min |
| Sample Gas Flow | 10–500 mL/min (recommended: 200 mL/min) |
| Drive Gas | Clean, dry air at 300 kPa (3 bar) |
| Electronic Gas Control | 5–10 bar input → 0–5 bar regulated output |
| Standard Fittings | 1/8″ stainless steel Swagelok® and VCR |
| Output Signal | 0–1 V analog |
| Alarm Outputs | Detector, system, flow, maintenance, temperature, pressure |
| Data Interface | TrendVision PLUS with 4–20 mA, Profibus, Modbus, RS-485 |
| Power Supply | 220 V AC |
| Dimensions (W×H×D) | 483 mm × 219 mm × 564 mm (19″ rack, 5U) |
| Weight | 25 kg |
| Brand | AGC |
|---|---|
| Origin | Ireland |
| Model | AGC100 Series |
| Instrument Type | Laboratory Gas Chromatograph |
| Application | High-Purity Gas Analysis |
| Oven Temperature Range | +5–450 °C |
| Oven Ramp Rate | 0.1–40 °C/min (0.1 °C increment) |
| Cooling Rate | 300–50 °C in ~5 min |
| Carrier Gas Flow Control Range | 0–500 mL/min |
| Carrier Gas Pressure Control Range | 0–700 kPa |
| Injector Max Temp | 450 °C |
| Injector Pressure Setting Range | 0–700 kPa |
| Injector Total Flow Setting Range | 10–500 mL/min |
| DID Operating Temp | 30–45 °C |
| Ambient Temp Requirement | 10–30 °C |
| Response Time (90%) | 0.5 s |
| Warm-up Time | 60 min |
| Display | 6.5″ color LCD with LED backlight and resistive touchscreen |
| Carrier Gas | Ultra-high-purity helium (He, N6.0), 20–60 mL/min |
| Sample Gas Flow | 10–500 mL/min (recommended: 200 mL/min) |
| Drive Gas | Clean, dry air at 300 kPa |
| Electronic Gas Control | Input 5–10 bar, output control 0–5 bar |
| Output Signal | 0–1 V analog |
| Communication | 4–20 mA, Profibus, Modbus RTU, RS-485 via TrendVision PLUS |
| Power Supply | 220 V AC |
| Dimensions (W×H×D) | 483 mm × 219 mm × 564 mm (19″ rack, 5U) |
| Weight | 25 kg |