| Brand | KeChuang |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Category | Domestic (China) |
| Model | GC9800 LPG-Dedicated Gas Chromatograph |
| Instrument Type | Laboratory Gas Chromatograph |
| Application Field | Petrochemical Industry-Specific |
| Oven Temperature Range | Ambient + 8 °C to 400 °C |
| Ramp Rate | 0.1–40 °C/min |
| Cooling Rate | 400 °C → 50 °C in ≤4 min |
| Carrier Gas Flow Range & Control | 0–100 mL/min |
| Carrier Gas Pressure Range & Control | 0–250 kPa |
| Injector Max Operating Temperature | 300 °C |
| Injector Pressure Setpoint Range | 0–250 kPa |
| Injector Total Flow Setpoint Range | 0–1200 mL/min |
| Brand | Ke Chuang |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Laboratory Gas Chromatograph |
| Model | GC2002 |
| Temperature Control Range | 3–450 °C |
| Oven Ramp Rate | 0–120 °C/min |
| Cooling Time | <4 min (450 °C → 50 °C at 22 °C ambient) |
| Carrier Gas Flow Range | 0–1200 mL/min |
| Carrier Gas Pressure Range | 0–600 kPa |
| Injector Max Temp | 3–450 °C |
| Injector Pressure Setpoint Range | 0–600 kPa |
| Injector Total Flow Setpoint Range | 0–1200 mL/min |
| EPC/EFC Pressure Accuracy | ±0.001 psi |
| EPC/EFC Flow Accuracy | ±0.001 mL/min |
| Temperature Stability | ±0.01 °C |
| Retention Time RSD | <0.008% |
| Peak Area RSD | <1.0% |
| Brand | Kechuang |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | OEM Manufacturer |
| Product Category | Domestic |
| Model | GC910B Portable/Vehicle-Mountable Gas Chromatograph |
| Instrument Type | Portable Gas Chromatograph |
| Application Scope | General-Purpose |
| Oven Temperature Range | Ambient + 8 °C to 400 °C |
| Heating Rate | 0.1–40 °C/min |
| Cooling Rate | 400 °C to 50 °C in ≤4 min |
| Carrier Gas Flow Range & Control | 0–100 mL/min |
| Carrier Gas Pressure Range & Control | 0–250 kPa |
| Injector Maximum Operating Temperature | 300 °C |
| Injector Pressure Setting Range | 0–250 kPa |
| Injector Total Flow Setting Range | 0–1200 mL/min |
| Brand | Kechuang |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Laboratory Gas Chromatograph |
| Model | GC9800N + Liquid Autosampler |
| Temperature Control Range | Ambient + 3 °C to 450 °C |
| Maximum Ramp Rate | 0–40 °C/min (adjustable in 0.1 °C/min increments) |
| Cooling Time | ≤4 min (350 °C → 50 °C, with motorized backdoor) |
| Carrier Gas Flow Range | 0–1200 mL/min |
| Carrier Gas Pressure Range | 0–970 kPa |
| Injector Temperature Max | 450 °C |
| Injector Pressure Setting Range | 0–970 kPa |
| Injector Total Flow Setting Range | 0–1200 mL/min |
| EPC/EFC Precision | ±0.001 psi (pressure), ±0.001 mL/min (flow) |
| Column Oven Dimensions | 305 × 160 × 278 mm (W × D × H) |
| Unit Weight | ≤50 kg |
| Power Supply | 220 V ±10%, 50 Hz ±5% |
| Operating Environment | 5–35 °C, ≤85% RH |