| Brand | AIRTECH (Sujing Antai) |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | BLB-1000 |
| Instrument Type | Vertical Laminar Flow Clean Bench |
| Cleanliness Class | ISO 5 (Class 100 @ ≥0.5 µm, per US Federal Standard 209E) |
| Noise Level | ≤62 dB(A) |
| User Capacity | Single-user, single-front configuration |
| Airflow Pattern | Vertical downward laminar flow |
| Work Surface Material | Seamless stainless steel (AISI 304) |
| Viewing Panels | Tempered glass side windows |
| Cabinet Construction | Cold-rolled steel with white electrostatic powder coating |
| Pre-filter | Washable aluminum mesh |
| HEPA Filter | 915 × 610 × 50 mm, single unit, H14 grade (EN 1822) |
| Average Air Velocity | ≥0.3 m/s (adjustable via 3-speed electronic control) |
| Illumination | ≥300 lx (LED lighting system) |
| Power Supply | AC 220 V, 1-phase, 50 Hz |
| Rated Power | 250 W |
| Net Weight | 190 kg |
| Working Area Dimensions (W×D×H) | 800 × 615 × 720 mm |
| Overall Dimensions (W×D×H) | 1000 × 810 × 1795 mm |
| Settling Microbial Count | ≤0.5 CFU/plate·0.5 h |
| UV Lamp | 254 nm germicidal lamp with programmable on/off scheduling |
| Safety Interlock | Lighting and UV sterilization systems mutually interlocked |
| Casters | Dual-mode—swivel with brake + adjustable leveling feet |
| Compliance | Meets YY 0569–2011 (Chinese standard for biological safety cabinets), GB/T 25220–2010 (clean bench performance testing), and general requirements of ISO 14644-1 for cleanroom equipment |
| Brand | AIRTECH |
|---|---|
| Origin | Jiangsu, China |
| Model Variants | HHS-1000-U / HHS-1300-U / HHS-1600-U / HHS-1800-U |
| Cleanliness Class | ISO Class 5 (100 @ ≥0.5 µm, per US FED-STD-209E) |
| Airflow Pattern | Horizontal laminar flow |
| Noise Level | ≤62 dBA |
| User Configuration | Single-user single-front or dual-user single-front |
| Compliance | YY/T 1539–2017 (China CFDA Medical Device Standard), Class II Medical Device Registration Certificate |
| Control Interface | Full-color LCD touchscreen with real-time display of airflow velocity, filter status, and fault diagnostics |
| Safety Interlocks | Integrated interlock between sash position, UV germicidal lamp activation, and LED lighting |
| Construction | Seamless curved stainless steel work surface (304 grade), ergonomically optimized for prolonged operation |
| Brand | AIRTECH |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model Variants | HS-840, HS-840-U, HS-1300, HS-1300-U |
| Instrument Category | Horizontal Laminar Flow Clean Bench |
| Cleanliness Class | ISO Class 5 (equivalent to Federal Standard 209E Class 100 @ ≥0.5 µm) |
| Noise Level | ≤62 dBA |
| User Configuration | Single-user single-face or dual-user single-face |
| Airflow Pattern | Horizontal unidirectional laminar flow |
| Regulatory Compliance | YY/T 1539–2017 (China CFDA Medical Clean Bench Standard), Class II Medical Device Registration Certificate issued |
| Brand | AIRTECH |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | HS-840-II |
| Instrument Type | Horizontal Laminar Flow Clean Bench |
| Cleanliness Class | ISO 5 (Class 100 per Fed. Std. 209E) |
| Noise Level | ≤62 dB(A) |
| User Capacity | Single-user, single-front configuration |
| Average Air Velocity | ≥0.3 m/s (adjustable) |
| Illumination | ≥300 lx |
| Power Supply | AC 220 V, 1φ, 50 Hz |
| Rated Power | 250 W |
| Net Weight | 125 kg |
| Work Area Dimensions (W×D×H) | 720 × 650 × 570 mm |
| Overall Dimensions (W×D×H) | 840 × 825 × 1430 mm |
| HEPA Filter Specification | 760 × 610 × 50 mm × 1 unit |
| Settling Microbial Count | ≤0.5 CFU/plate·0.5 h |
| Pre-filter | Quick-release, washable design |
| Safety Compliance | Meets GB/T 25225–2010 (Chinese National Standard for Laminar Flow Clean Benches), IEC 61010-1:2010 (Safety Requirements for Electrical Equipment for Measurement, Control, and Laboratory Use) |
| Brand | AIRTECH |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model Variants | HS-840-II, HS-1300-II, HS-840-U-II, HS-1300-U-II |
| Instrument Category | Horizontal Flow Clean Bench |
| Cleanliness Class | ISO Class 5 (equivalent to Federal Standard 209E Class 100 @ ≥0.5 µm) |
| Sound Pressure Level | ≤62 dBA |
| User Configuration | Single-user single-face or dual-user single-face |
| Airflow Pattern | Horizontal unidirectional laminar flow |
| Control Interface | Digital display with touch-sensitive keypad |
| Fan Speed | 3-step adjustable |
| UV Lamp Control | Programmable on/off scheduling |
| Runtime Monitoring | Real-time cumulative operating time for fan, UV lamp, and filter |
| Viewing Panels | Embedded tempered glass on both side walls |
| Work Surface | Seamless 304 stainless steel with front-radius edge design |
| Cabinet Material | Cold-rolled steel with ivory-white electrostatic powder coating |
| Structural Design | Aerodynamically optimized chassis minimizing airflow turbulence |
| Mobility System | Dual-mode casters (swivel + locking brake) with leveling feet |
| Pre-filter Access | Tool-free rapid replacement and washable design |
| Safety Interlock | UV lamp and lighting circuits mutually interlocked |
| Power Features | Integrated backup socket with power-fail protection |
| Factory Certification | Performed per ISO 14644-1, IEST-RP-CC002.3, and GB/T 25227–2010 performance validation protocols |
| Brand | AIRTECH |
|---|---|
| Origin | Jiangsu, China |
| Model Variants | HVS-1000-U, HVS-1300-U, HVS-1600-U, HVS-1800-U |
| Classification | Vertical Laminar Flow Clean Bench |
| Cleanliness Class | ISO Class 5 (equivalent to Federal Standard 209E Class 100 @ ≥0.5 µm) |
| Noise Level | ≤62 dBA |
| Operator Configuration | Single-user single-front or dual-user single-front |
| Airflow Pattern | Vertical downward laminar flow |
| Regulatory Compliance | YY/T 1539–2017 (China CFDA Medical Clean Bench Standard), Class II Medical Device Registration Certificate issued |
| Control Interface | Full-color LCD touchscreen with real-time display of inflow velocity, filter status, and fault alerts |
| Safety Interlocks | Integrated interlock between sash position, UV germicidal lamp activation, and lighting system |
| Construction | Seamless curved stainless steel work surface (304 grade), ergonomically contoured front edge |
| Fan System | Variable-air-volume (VAV) EC motor-driven blower with high-efficiency low-energy operation |
| Lighting | Uniform LED illumination (≥600 lux at work surface) |
| Pre-shipment Testing | 100% factory validation per ISO 14644-1 and YY/T 1539–2017 performance & safety protocols |
| Brand | AIRTECH |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model Variants | SW-CJ-1B, SW-CJ-1BU, SW-CJ-1C, SW-CJ-1CU |
| Instrument Category | Horizontal Flow Clean Bench |
| Cleanliness Class | ISO Class 5 (100 @ ≥0.5 µm, per US Federal Standard 209E) |
| Noise Level | ≤62 dBA |
| User Configuration | Single-user single-face or dual-user single-face |
| Airflow Pattern | Horizontal laminar flow |
| Regulatory Compliance | YY/T 1539–2017 (CFDA Medical Device Standard), Class II Medical Device Registration Certificate |
| Brand | AIRTECH |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Models | SW-CJ-1F, SW-CJ-1FD, SW-CJ-2F, SW-CJ-2FD |
| Instrument Type | Vertical Flow Clean Bench |
| Cleanliness Class | ISO Class 5 (100 @ ≥0.5 µm, per US Federal Standard 209E) |
| Noise Level | ≤62 dBA |
| User Configuration | Single-Operator Single-Face, Single-Operator Dual-Face, Dual-Operator Single-Face, Dual-Operator Dual-Face |
| Airflow Pattern | Vertical Downflow |
| Regulatory Compliance | YY/T 1539–2017 (China CFDA Medical Clean Bench Standard), Class II Medical Device Registration Certificate Issued |
| Brand | AIRTECH (Suzhou Antai) |
|---|---|
| Origin | Jiangsu, China |
| Instrument Type | Vertical Laminar Flow Clean Bench |
| Cleanliness Class | ISO 5 (equivalent to US FED STD 209E Class 100) |
| Noise Level | ≤62 dB(A) |
| User Configuration | Dual-operator, dual-sided (SW-CJ-2F) or dual-operator, single-sided (SW-CJ-2FD) |
| Airflow Pattern | Vertical unidirectional laminar flow |
| Average Air Velocity | ≥0.3 m/s (adjustable) |
| Illumination | ≥300 lx |
| Power Supply | AC 220 V, 1φ, 50 Hz |
| Rated Power | 500 W |
| Weight | 170 kg |
| Work Area Dimensions (W×D×H) | 1360×690×520 mm (SW-CJ-2F), 1360×690×520 mm (SW-CJ-2FD) |
| Overall Dimensions (W×D×H) | 1500×750×1600 mm (SW-CJ-2F), 1500×730×1600 mm (SW-CJ-2FD) |
| HEPA Filter Specification | 610×610×50 mm ×2 units |
| Settling Microbial Count | ≤0.5 CFU/plate·0.5 h |
| Pre-filter | Quick-access washable design |
| Control Interface | Digital display with touch keys |
| Safety Interlock | UV lamp and lighting circuit interlocked |
| UV Timer Function | Programmable on/off scheduling |
| Runtime Monitoring | Real-time cumulative operating hours for fan, UV lamp, and HEPA filter |
| Construction | Stainless steel monolithic work surface |
| Mobility | Locking omnidirectional casters |
| Brand | AIRTECH |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Models | SW-CJ-1B / SW-CJ-1BU / SW-CJ-1C / SW-CJ-1CU-II |
| Instrument Type | Horizontal Flow Clean Bench |
| Cleanliness Class | ISO Class 5 (100 @ ≥0.5 µm, per US Federal Standard 209E) |
| Noise Level | ≤62 dBA |
| User Configuration | Single- or Dual-Operator, Front-Access Only |
| Airflow Pattern | Horizontal Laminar Flow |
| Control Interface | Digital Display with Touch-Sensitive Keypad |
| UV Timer Function | Programmable On/Off Scheduling |
| Runtime Monitoring | Real-Time Accumulated Hours for Fan, UV Lamp, and Pre-Filter |
| Viewing Panels | Embedded Tempered Glass on Both Sides |
| Work Surface | Seamless Stainless Steel (AISI 304) |
| Enclosure Material | Cold-Rolled Steel with Ivory White Electrostatic Powder Coating |
| Structural Design | Aerodynamically Optimized Cabinet Profile |
| Mobility System | Locking Swivel Casters (360° Rotation) |
| Pre-Filter Access | Tool-Free Quick-Release Mechanism |
| Safety Interlock | UV Lamp Deactivation When Lighting Circuit Is Active |
| Power Protection | Built-in Backup Socket with Emergency Power-Off Capability |
| Compliance | Factory-Tested per GB/T 25227–2010 (Chinese National Standard for Clean Benches), Meets IEC 61010-1 Safety Requirements for Laboratory Equipment |
| Brand | AIRTECH |
|---|---|
| Origin | Jiangsu, China |
| Model Variants | SW-CJ-1F, SW-CJ-1FD, SW-CJ-2F, SW-CJ-2FD-II |
| Airflow Type | Vertical Downflow |
| Cleanliness Class | ISO Class 5 (100 @ ≥0.5 µm, per US Federal Standard 209E) |
| Noise Level | ≤62 dBA |
| Operator Configurations | Single-Person/Single-Side, Single-Person/Double-Side, Double-Person/Single-Side, Double-Person/Double-Side |
| Construction | Stainless Steel Work Surface, Powder-Coated Cold-Rolled Steel Enclosure |
| Pre-Filter | Quick-Release Design for Easy Cleaning and Replacement |
| UV Lamp Control | Programmable On/Off Scheduling with Runtime Monitoring |
| Fan Speed | Three-Step Adjustable |
| Safety Interlock | Lighting and UV Sterilization Systems Are Electrically Interlocked |
| Power Protection | Built-in Uninterruptible Power Backup Function |
| Mobility | Locking Swivel Casters with Brake Mechanism |
| Compliance | Factory-Tested per GB/T 25223–2010 (Chinese National Standard for Clean Benches), Meets General Requirements of YY 0569–2011 (Medical Device Safety for Biological Safety Cabinets) |
| Brand | AIRTECH |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | VS-840K-II |
| Instrument Type | Vertical Flow Clean Bench |
| Cleanliness Class | ISO 5 (Class 100 per Fed. Std. 209E) |
| Noise Level | ≤62 dB(A) |
| User Capacity | Single-user, single-front configuration |
| Airflow Pattern | Vertical unidirectional laminar flow |
| Average Air Velocity | ≥0.3 m/s (adjustable in three stages) |
| Illumination | ≥300 lx |
| Power Supply | AC 220 V, 1φ, 50 Hz |
| Rated Power | 250 W |
| Net Weight | 145 kg |
| Work Area Dimensions (W×D×H) | 680 × 650 × 570 mm |
| Overall Dimensions (W×D×H) | 840 × 825 × 1625 mm |
| HEPA Filter Specification | 760 × 610 × 50 mm × 1 unit |
| Settling Microbial Count | ≤0.5 CFU/plate·0.5 h |
| Pre-filter | Quick-release, washable design |
| UV Lamp | Scheduled on/off control with runtime logging |
| Safety Interlock | Lighting and UV sterilization systems mutually interlocked |
| Foot Mobility | Dual-mode casters (swivel + locking leveling feet) |
| Brand | Allentown |
|---|---|
| Origin | Canada |
| Model | Phantom2 |
| Certification | ISO 14644-1 Class 3 Verified |
| Filtration | Dual-stage HEPA (≥99.995% @ 0.3 µm) |
| Airflow System | Unidirectional laminar flow with Active Barrier Control (ABC) |
| Work Area Opening Height | Up to 406 mm |
| Height Adjustment | Motorized, 305 mm travel with 4 programmable memory positions |
| Lighting | Adjustable-intensity LED (6000K white + red-light mode) |
| Display | Full-color touchscreen interface (8 languages) |
| Construction | Tempered safety glass (6 mm), polycarbonate rear panel (6 mm), IP-rated USB 2.0 ports |
| Motor | Energy-efficient ECM fan with ±1% airflow stability under variable filter load |
| Cabinet Temperature Rise | <1 °C during operation |
| Mobility | 127 mm polyurethane casters with brakes |
| Compliance | Designed for GLP/GMP-aligned animal facilities |
| Brand | AnTai |
|---|---|
| Origin | Jiangsu, China |
| Model | BCM-1000A |
| Instrument Category | Vertical Flow Clean Bench |
| Cleanliness Class | ISO Class 5 (equivalent to US FED-STD-209E Class 100) |
| Noise Level | ≤62 dB(A) |
| User Configuration | Single-operator, dual-front access |
| Airflow Pattern | Vertical downward laminar flow |
| Average Air Velocity | 0.25–0.45 m/s (adjustable) |
| Exhaust Air Volume | 2 m³/min |
| Vibration (Half-Peak) | ≤5 µm |
| Illuminance | ≥300 lx |
| Power Supply | AC 220 V, 50 Hz |
| Max. Power Consumption | 0.8 kW |
| Net Weight | 300 kg |
| Work Area Dimensions (W×D×H) | 1000 × 700 × 620 mm |
| Overall Dimensions (W×D×H) | 1160 × 760 × 1780 mm |
| Supply HEPA Filter | 915 × 610 × 50 mm (1 unit) |
| Exhaust HEPA Filter | 480 × 90 × 50 mm (1 unit) |
| Fluorescent Lamp | 20 W × 2 |
| UV Lamp | 20 W × 2 |
| Optional Outlets | 2 kW rated socket |
| Brand | AnTai |
|---|---|
| Origin | Jiangsu, China |
| Model | HS-1300-U |
| Cleanliness Class | ISO Class 5 (equivalent to Fed. Std. 209E Class 100) |
| Airflow Pattern | Horizontal unidirectional laminar flow |
| Noise Level | ≤62 dB(A) |
| Operating Configuration | Dual-user, single-face workstation |
| Average Air Velocity | 0.3–0.6 m/s (adjustable) |
| Vibration (half-peak) | ≤3 µm |
| Illuminance | ≥300 lx |
| Power Supply | AC 220 V, 50 Hz |
| Max. Power Consumption | 0.4 kW |
| Net Weight | 160 kg |
| Work Area Dimensions (W×D×H) | 1180 × 650 × 570 mm |
| External Dimensions (W×D×H) | 1300 × 825 × 1430 mm |
| Pre-filter Airflow Control | Adjustable aluminum damper |
| Filter Type | Ultra-thin, bag-type HEPA filter (no separator design) |
| Work Surface | Imported stainless steel |
| Side Panels | Tempered glass |
| Brand | Chuanheng Instrument |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Direct Manufacturer |
| Equipment Category | Vertical Laminar Flow Clean Bench |
| Model | SW-CJ-1D |
| Cleanliness Class | ISO Class 5 (100 @ ≥0.5 µm, per US Federal Standard 209E) |
| Average Air Velocity | 0.25–0.45 m/s (dual-speed control) |
| Noise Level | ≤62 dB(A) |
| User Configuration | Single-user, front-access |
| Airflow Pattern | Vertical downward laminar flow |
| Work Area Dimensions | 700 × 500 × 520 mm |
| Overall Dimensions | 850 × 580 × 1550 mm |
| Power Supply | AC 220 V, 50 Hz |
| Rated Power | 0.3 kW |
| HEPA Filter | 695 × 460 × 38 mm, single unit |
| Lighting | 15 W fluorescent lamp + 15 W UV germicidal lamp |
| Control | Infrared remote (fan speed high/low, lighting, UV sterilization, power on/off) |
| Brand | Erlab |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | Flow 483 Smart |
| Pricing | Upon Request |
| Instrument Type | Vertical Laminar Flow Clean Bench |
| Cleanliness Class | ISO Class 5 (equivalent to Federal Standard 209E Class 100) |
| Noise Level | 61 dB(A) |
| User Capacity | Single-user, front-access only |
| Airflow Pattern | Vertical downward laminar flow |
| Filter Options | HEPA H14 (≥99.995% @ 0.1 µm) or ULPA U17 (≥99.999995% @ 0.1 µm) |
| Compliance | EN ISO 14644-1:2015 |
| Brand | Erlab |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model Series | PCR Clean Bench |
| Pricing | Upon Request |
| Instrument Type | Horizontal Laminar Flow Clean Bench |
| Filtration | HEPA/ULPA U17 (99.999995% @ 0.12 µm) |
| Brand | Esco |
|---|---|
| Model | VBD |
| Origin | Singapore |
| Type | ULPA-Filtered Clean Bench for Animal Facility Use |
| Power Supply | 220–240 VAC, 50 Hz |
| Inflow Air Velocity | 0.35 m/s (70 fpm) |
| External Dimensions (H min/max) | 1247 × 760 × 1966 mm / 1247 × 760 × 2271 mm |
| Internal Work Area | 1040 × 680 × 594 mm |
| Filter System | ULPA + Nanocarb Activated Carbon + Pre-filter |
| Surface Finish | Stainless Steel (ISOCEDE® Antimicrobial Coating) |
| Integrated Waste Container | 40-gallon NSF-certified |
| Height Adjustment | Hydraulic Mechanism |
| Control System | Sentinel Microprocessor-based Controller |
| Compliance | NSF/ANSI 49 Class I Equivalent Design Principles, ISO 14644-1 Class 5 (at work surface), GLP-ready configuration |
| Brand | Esco |
|---|---|
| Origin | Singapore |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | VDA-4A8 / VDA-5A8 |
| Pricing | Available Upon Request |
| External Dimensions (L×W×H) | VDA-4A8 – 1340 × 762 × 1961 mm (low height) / 1340 × 762 × 2245 mm (high height) |
| Work Area Dimensions (L×W×H) | VDA-4A8 – 1100 × 465 × 564 mm |
| Downflow Velocity | 0.24 m/s (47 fpm) |
| Power Supply | 220–240 VAC, 50/60 Hz, 1-phase |
| Brand | FUXIA |
|---|---|
| Origin | Zhejiang, China |
| Model | SW-CJ-2F |
| Instrument Type | Vertical Laminar Flow Clean Bench |
| Cleanliness Class | ISO Class 5 (100 @ ≥0.5 µm, Fed. Std. 209E) |
| Noise Level | ≤62 dB(A) |
| Operator Capacity | Dual-operator, dual-sided |
| Airflow Pattern | Vertical downward laminar flow |
| Average Air Velocity | 0.25–0.45 m/s |
| Illumination | ≥300 lx |
| UV Lamp | 15 W × 2 |
| Fluorescent Lamp | 16 W × 2 |
| Power Supply | AC 220 V / 50 Hz |
| Power Consumption | 800 W |
| Net Weight | 200 kg |
| Working Area Dimensions | 1360 × 600 × 520 mm |
| Overall Dimensions | 1540 × 680 × 1600 mm |
| Microbial Contamination | <0.5 CFU/plate·hour (90 mm Petri dish) |
| Vibration | ≤0.5 µm (peak-to-peak, XYZ axes) |
| Control Interface | Digital LCD with three-speed fan control |
| Safety Interlock | UV lamp and lighting circuits mutually interlocked |
| Brand | HJ Purification |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Vertical Laminar Flow Clean Bench |
| Model | SW-CJ-1D |
| Cleanliness Class | ISO Class 5 (100 @ ≥0.5 µm, Fed. Std. 209E) |
| Noise Level | ≤62 dB(A) |
| User Capacity | Single Operator, Front-Access Configuration |
| Airflow Pattern | Vertical Downflow |
| Average Air Velocity | 0.25–0.45 m/s (Dual-Speed Control) |
| Microbial Contamination | ≤0.5 CFU/plate·hr (Φ90 mm settle plate) |
| Vibration | ≤5 µm peak-to-peak (X/Y/Z axes) |
| Illumination | ≥300 lux |
| Power Supply | AC 220 V, 50 Hz |
| Max. Power Consumption | 300 W |
| Net Weight | 85 kg |
| Work Area Dimensions (W×D×H) | 700 × 490 × 515 mm |
| Overall Dimensions (W×D×H) | 855 × 550 × 1600 mm |
| HEPA Filter Spec. | 695 × 460 × 38 mm (1 unit) |
| Fluorescent Lamp | 15 W (1 unit) |
| UV Lamp | 15 W (1 unit) |
| Pre-filter | Integrated coarse particulate pre-filter |
| Control Interface | Digital LCD panel with interlocked safety logic |
| Brand | HJ Purification |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | HS-840U |
| Instrument Type | Horizontal Flow Clean Bench |
| Cleanliness Class | ISO Class 5 (100 @ ≥0.5 μm, Fed. Std. 209E) |
| Noise Level | ≤62 dB(A) |
| User Capacity | Single Operator, Front-Access Configuration |
| Airflow Pattern | Horizontal Laminar Flow |
| Pre-filter Material | Aluminum Alloy |
| HEPA Filter Specification | 695 × 600 × 38 mm, Single Unit |
| Illumination | ≥300 lx |
| Average Air Velocity | 0.25–0.45 m/s (Dual-Speed Control) |
| Vibration Amplitude | ≤0.5 μm (peak-to-peak, XYZ axes) |
| Power Supply | AC 220 V / 50 Hz |
| Max. Power Consumption | 400 W |
| Net Weight | 100 kg |
| Work Area Dimensions (W×D×H) | 700 × 560 × 580 mm |
| Overall Dimensions (W×D×H) | 855 × 765 × 1765 mm |
| UV Lamp | 20 W × 1 |
| Fluorescent Lamp | 20 W × 1 |
| Microbial Recovery | ≤0.5 CFU/plate·hr (90 mm Petri dish) |
| Brand | MILLET |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | MLT-BCV Series |
| Price Range | USD 1,400 – 7,000 |
| Instrument Type | Vertical Laminar Flow Clean Bench |
| Cleanliness Class | ISO 5 (Class 100) |
| Noise Level | ≤ 62 dB(A) |
| User Capacity | Single-Operator Single-Face or Dual-Operator Dual-Face Configurations |
| Airflow Pattern | Vertical Downflow |
| Filtration Efficiency | ≥ 99.99% @ 0.3 µm (HEPA H14 per EN 1822) |
| Average Air Velocity | 0.30–0.50 m/s (adjustable in 0.01 m/s increments) |
| Illumination | ≥ 900 lx |
| Vibration Amplitude | ≤ 3–4 µm (depending on model) |
| Power Supply | 220 V AC / 50 Hz |
| Max Power Consumption | 250–750 VA |
| Working Area Dimensions (W×D×H) | 920×620×645 mm to 1820×620×645 mm |
| Overall Dimensions (W×D×H) | 1060×720×1745 mm to 1960×720×1745 mm |
| Microbial Contamination | ≤ 0.5 CFU/plate/hour (90 mm Petri dish) |
| Origin | Jiangsu, China |
|---|---|
| Manufacturer Type | Distributor |
| Origin Category | Domestic |
| Model | SW-CJ-1B |
| Price | USD 850 (est.) |
| Instrument Type | Horizontal Laminar Flow Clean Bench |
| Cleanliness Class | ISO Class 5 (equivalent to Fed. Std. 209E Class 100) |
| Noise Level | ≤62 dB(A) |
| User Capacity | Single-user, single-front configuration |
| Airflow Pattern | Horizontal laminar flow |
| Average Air Velocity | 0.3–0.6 m/s (adjustable) |
| Vibration (Half-Peak) | ≤3 µm |
| Illumination | ≥300 lx |
| Power Supply | AC 200 V, 1Φ, 50 Hz |
| Max. Power Consumption | 0.4 kW |
| Net Weight | 110 kg |
| Work Area Dimensions (W×D×H) | 820 × 480 × 600 mm |
| Overall Dimensions (W×D×H) | 900 × 700 × 1450 mm |
| HEPA Filter Spec. | 820 × 600 × 50 mm, single unit |
| Lighting | 20 W fluorescent lamp (1×), optional UV lamp (20 W, 1×) |
| Surface Material | Imported stainless steel work surface |
| Differential Pressure Gauge | Integrated |
| Fan System | Variable-speed centrifugal blower with touch-control voltage regulation |
| Brand | Zhicheng |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | ZHJH-C1106B |
| Pricing | Available Upon Request |
| Airflow Pattern | Vertical Laminar Flow |
| Work Surface | Single Opening |
| Filtration Standard | ISO 14644-1 Class 5 (equivalent to Fed Std 209E Class 100) |
| Particle Count | ≤0.5 CFU/plate (90 mm Petri dish) |
| Adjustable Air Velocity | 0.3–0.6 m/s (7-step LED digital control) |
| Noise Level | ≤62 dB(A) |
| Vibration Peak-to-Peak | ≤6 µm |
| Illumination | ≥300 lx |
| Pre-filter Initial Resistance | ≤120 Pa (at max airflow) |
| Working Area Dimensions (W×D×H) | 600 × 625 × 645 mm |
| Overall Dimensions (W×D×H) | 720 × 740 × 1700 mm |
| Net Weight | 118 kg |
| Power Consumption | 380 W |
| Electrical Supply | AC 220 V, 50/60 Hz |
| UV Germicidal Lamp | Included (254 nm) |
| Lighting | Fluorescent Task Lamp |
| Construction | Stainless Steel Work Surface, Electrostatically Powder-Coated Steel Casing |
| Mobility | Four Swivel Casters with Locking Brakes |
| Window Mechanism | Counterbalanced Vertical Sliding Sash |
| Viewing Panels | Dual Side Tempered Glass |
| Compliance | Meets ISO 14644-1, GB/T 16292–2010, and JIS K 3800:2014 for clean bench performance verification |
| Brand | Zhicheng |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | ZHJH-C1106C |
| Pricing | Upon Request |
| Airflow Pattern | Vertical Downflow |
| Work Surface | Single Opening |
| Working Area Dimensions (W×D×H) | 600 × 625 × 645 mm |
| Overall Dimensions (W×D×H) | 720 × 740 × 1700 mm |
| Net Weight | 118 kg |
| Power Supply | AC 220 V, 50/60 Hz |
| Rated Power | 380 W |
| Noise Level | ≤62 dB(A) |
| Illumination | ≥300 lx |
| Vibration Semi-Peak | ≤3 µm |
| HEPA Filtration Efficiency | ≥99.995% @ 0.3 µm |
| Cleanliness Class | ISO Class 5 (FS209E Class 100) |
| Microbial Contamination | ≤0.5 CFU/plate (90 mm Petri dish) |
| Adjustable Air Velocity Range | 0.1–1.0 m/s |
| Operational Air Velocity Range | 0.3–0.6 m/s (infinitely variable, ±0.05 m/s control accuracy) |
| Air Velocity Resolution | 0.1 m/s |
| HEPA Differential Pressure Range | 0–500 Pa |
| Pressure Display Accuracy | ±1% |
| Initial Resistance | ≤120 Pa (at maximum airflow) |
| Pre-filter | Washable aluminum mesh |
| UV Lamp | High-output quartz germicidal lamp (253.7 nm) |
| Control Interface | Backlit LCD touchscreen with Chinese UI |
| Operating Modes | Manual / Auto-selectable |
| Timer Functions | Cumulative runtime counter, programmable UV disinfection schedule |
| Safety Features | Dual-side tempered glass viewport, self-balancing sliding sash, stainless steel work surface (electropolished finish), rounded internal corners |
| Brand | Zhicheng |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | ZHJH-C1109B |
| Pricing | Available Upon Request |
| Airflow Pattern | Vertical Laminar Flow |
| Work Surface | Single-sided |
| Filtration Efficiency | ≥99.995% @ 0.3 µm (HEPA H14) |
| Cleanliness Class | ISO Class 5 (US FED STD 209E Class 100) |
| Microbial Recovery | ≤0.5 CFU/plate (90 mm Petri dish) |
| Adjustable Air Velocity | 0.3–0.6 m/s (7-step LED digital control) |
| Noise Level | ≤62 dB(A) |
| Vibration Peak-to-Peak | ≤6 µm |
| Illuminance | ≥300 lx |
| Pre-filter Initial Resistance | ≤120 Pa (at max airflow) |
| Working Area Dimensions (W×D×H) | 900 × 625 × 645 mm |
| Overall Dimensions (W×D×H) | 1020 × 740 × 1700 mm |
| Net Weight | 153 kg |
| Power Consumption | 380 W |
| Electrical Supply | AC 220 V, 50/60 Hz |
| Construction | Electrophoretically coated steel frame with stainless steel work surface |
| Mobility | Four swiveling casters with locking brakes |
| Brand | Zhicheng |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Category | Vertical Laminar Flow Clean Bench |
| Cleanliness Class | ISO Class 5 (100 @ ≥0.5 µm, per Fed. Std. 209E) |
| Noise Level | ≤62 dB(A) |
| User Capacity | Single-user, front-facing operation |
| Airflow Pattern | Vertical downward laminar flow |
| Work Area Dimensions | 900 × 625 × 645 mm (W × D × H) |
| Overall Dimensions | 1020 × 740 × 1700 mm (W × D × H) |
| Net Weight | 153 kg |
| Power Supply | AC 220 V, 50/60 Hz |
| Rated Power | 380 W |
| Illumination | ≥300 lx |
| Vibration Peak-to-Peak | ≤3 µm |
| Adjustable Air Velocity Range | 0.1–1.0 m/s (settable), Operational Range: 0.3–0.6 m/s |
| Velocity Control Accuracy | ±0.05 m/s |
| Velocity Resolution | 0.1 m/s |
| HEPA Differential Pressure Range | 0–500 Pa |
| Pressure Display Accuracy | ±1% FS |
| Initial Resistance | ≤120 Pa (at max airflow) |
| Brand | Zhicheng |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | ZHJH-C1112B |
| Pricing | Upon Request |
| Airflow Direction | Vertical Laminar Flow |
| Work Surface | Single |
| Filtration Efficiency | ISO Class 5 (equivalent to Federal Standard 209E Class 100) @ ≥0.5 µm |
| Microbial Contamination | ≤0.5 CFU/plate (90 mm Petri dish) |
| Adjustable Air Velocity Range | 0.3–0.6 m/s (7-step LED digital control) |
| Noise Level | ≤62 dB(A) |
| Vibration Peak-to-Peak Amplitude | ≤4 µm |
| Illumination | ≥300 lx |
| Initial Filter Resistance | ≤120 Pa (at maximum airflow) |
| Working Area Dimensions (W×D×H) | 1200 × 625 × 645 mm |
| Overall Dimensions (W×D×H) | 1320 × 740 × 1700 mm |
| Net Weight | 215 kg |
| Power Consumption | 680 W |
| Input Voltage/Frequency | AC 220 V, 50/60 Hz |