| Brand | Sundy |
|---|---|
| Model | SDLM1250 |
| Origin | Hunan, China |
| Type | Fixed-mount 3D LiDAR-based coal stockpile volume measurement system |
| Measurement Range | 250 m |
| Scan Angle | 360° horizontal, ±30° vertical (typical) |
| Accuracy | <0.3% relative error |
| Measurement Time per Stack | ≤20 min (for up to 100,000 m³ pile, coverage area 280 × 60 m) |
| Data Acquisition Interval | ≥10 ms |
| Response Time | ≤20 s |
| Operating Temperature | −40 °C to +70 °C |
| Power Supply | 24 V DC ±15% |
| Total Power Consumption | 36 W (scanner), 140 W (heating unit) |
| Ingress Protection | IP67 |
| Mounting | Integrated with stacker-reclaimer or bucket-wheel stacker via rigid mechanical interface |
| Travel Sensor Compatibility | Optional encoder-based linear displacement sensor for synchronized motion compensation |
| Brand | Sundy |
|---|---|
| Model | SDLM300 |
| Origin | Hunan, China |
| Type | Portable 3D Laser-Based Volumetric Measurement System for Bulk Material Stacks |
| Volume Accuracy | ≤1.5% (V < 1000 m³), ≤1.0% (V ≥ 1000 m³) |
| Operating Temperature | −30 °C to +55 °C (laser unit: −30 °C to +60 °C) |
| Battery Life | 4 h (laser rangefinder, single battery), 3 h (rugged tablet, full charge) |
| IP Rating | IP56 |
| Drop Resistance | MIL-STD-810G compliant (tablet) |
| Laser Range | 1900 m (≥10% reflectivity), ±4 cm accuracy (typical target < 400 m) |
| Inclination Measurement | ±85°, ±0.1° resolution |
| Horizontal Angle | 0–360°, ±0.01° resolution |
| Total Unit Weight | ~3.5 kg (varies with tablet/stabilization mount) |
| Compliance | ASTM D6172 (standard practice for volumetric measurement of stockpiles), ISO 11222:2017 (geospatial data quality for volume estimation), GLP-aligned data traceability |
| Brand | Sundy |
|---|---|
| Origin | Hunan, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | SDUAV |
| Pricing | Available Upon Request |
| Endurance | 40 min |
| Wind Resistance | 12 m/s |
| Camera Resolution | 20 MP |
| Volumetric Measurement Accuracy | < 0.5% |
| Ground Sampling Distance (GSD) | 4 cm |
| Operating Temperature Range | −35 °C to +50 °C |
| UAV Weight | 915 g |
| Brand | SUNJUNE |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | VP-TA1 |
| RF Frequency | 13.56 MHz |
| RF Power | 500 W |
| Maximum Chamber Temperature | ≤150 °C |
| Continuous Unattended Operation | ≥8 h |
| Vacuum Display | Digital Real-Time Readout |
| Gas Inlets | 2 Independent Mass-Flow-Controlled Ports |
| Control Interface | Touchscreen with Integrated Plasma Control Software (Registration No. 2021SR1026389) |
| Warranty | 2 Years Comprehensive |
| Brand | Tianyan |
|---|---|
| Model | TY-HRD |
| Origin | Shandong, China |
| Temperature Range | 0–1600 °C (±3 °C accuracy) |
| Resolution | 1 °C (temperature), 1 min (time |
| Heating Rate | 15–20 °C/min up to 900 °C |
| Thermocouple Type | S-type (Platinum-Rhodium/Platinum) |
| Max Control Current | 30 A |
| Power Supply | 220 V ±10%, 50 Hz |
| Power Consumption | 10 W |
| Dimensions (W×H×D) | 305×390×120 mm |
| Operating Environment | 0–40 °C, RH ≤80% |
| Communication Interface | RS232 |
| Compliance | GB/T 219–2008 (Chinese National Standard for Coal Ash Fusibility) |
| Brand | Trace Elemental Instruments |
|---|---|
| Origin | Netherlands |
| Model | XPLORER TX/TS |
| Detection Principle | Combustion Microcoulometry |
| Sample Types | Solids, Liquids, Gases, LPG |
| Measurement Range (S) | 0.0020–500 mg |
| Measurement Range (Cl) | 0.0025–1000 mg |
| LOD (S) | 0.020 mg/L |
| LOD (Cl) | 0.025 mg |
| Combustion Furnace Temperature | 1050 °C |
| Software | TEIS 2 Professional |
| Brand | Yuntang |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | YT-CSL |
| Power Supply | AC 220 V ±10%, 50 Hz |
| Max. Power Consumption | ≤3 kW |
| Dimensions (L×W×H) | 770×460×410 mm |
| Sample Capacity | 1–15 samples per run (continuous loading enabled) |
| Sulfur Measurement Range | 0–40 wt% |
| Combustion Time per Sample | ~5–7 min (including 45 s at 500 °C and 4 min 45 s at 1050 °C) |
| Temperature Control Accuracy | ±5 °C |
| High-Temperature Zone | ≥90 mm length, stabilized at 1050 °C ±5 °C |
| Thermocouple Class | 0.5 |
| Electrolytic Cell Volume | 450 mL |
| Platinum Electrode Area | 150 mm² |
| Heating Rate | 20–25 °C/min (reaches 1050 °C in ~30 min) |
| Repeatability (St,ad) | ≤0.05% (St <1%), ≤0.10% (1%≤St≤4%), ≤0.20% (St >4%) |
| Reproducibility (St,d) | ≤0.10% (St <1%), ≤0.20% (1%≤St≤4%), ≤0.30% (St >4%) |
| Temperature Compensation | Automatic |
| Data Storage | Permanent digital archive with query & print capability |
| Multi-PC Data Sharing | Supported |
| Safety Protections | Silicon Carbide Tube Auto-Protection, Overcurrent Protection |
| Brand | Yuntang |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | YT-CSL· |
| Detection Principle | Coulometric Titration (ASTM D3177, ISO 351, GB/T 214-2007) |
| Sulfur Range | 0–40 wt% |
| Sample Capacity | 1–15 samples per batch (continuous loading enabled) |
| Analysis Time | ~5–7 min per sample |
| Furnace Temp Control | 1050 °C ±5 °C (adjustable), High-Temp Zone ≥90 mm |
| Heating Element | Silicon Carbide Tube |
| Electrolytic Cell Volume | 450 mL |
| Pt Electrode Area | 150 mm² |
| Temp Sensor Accuracy | Class 0.5 |
| Repeatability | ≤0.05% (St <1%), ≤0.10% (1%≤St≤4%), ≤0.20% (St>4%) |
| Reproducibility | ≤0.10% (St <1%), ≤0.20% (1%≤St≤4%), ≤0.30% (St>4%) |
| Power Supply | AC 220 V ±10%, 50 Hz, ≤3 kW |
| Dimensions (L×W×H) | 770×460×410 mm |
| Brand | Yuntang |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | YT-LR1 |
| Price Range | USD 1,600 – 5,300 (FOB) |
| Heat Capacity | 10,500 J/K |
| Ambient Temperature Range | 5–35 °C |
| Ignition Voltage | 24 V DC |
| Ignition Duration | 5 s |
| Temperature Measurement Range | 0–40 °C |
| Temperature Resolution | 0.0001 K |
| Power Consumption | ≤80 W |
| Supply Voltage | AC 220 V ±10 %, 50 Hz ±1 Hz |
| Net Weight | 35 kg |
| Dimensions (W×D×H) | 420 × 600 × 470 mm |
| Packaged Weight | 45 kg |
| Packaged Dimensions | 470 × 650 × 500 mm |
| Brand | Yuntang |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | YT-LR1 Oxygen Bomb Calorimeter |
| Price Range | USD 1,600 – 5,300 (FOB) |
| Measurement Principle | Isoperibol Bomb Calorimetry |
| Thermal Capacity | 10,500 J/K |
| Temperature Resolution | 0.0001 K |
| Ambient Temp. Range | 5–35 °C |
| Ignition Voltage | 24 V DC |
| Ignition Duration | 5 s |
| Measuring Temp. Range | 0–40 °C |
| Relative Humidity Limit | ≤80% RH |
| Max. Ambient Temp. Fluctuation | ±1 K during test |
| Power Supply | AC 220 V ±10%, 50 Hz ±1 Hz |
| Power Consumption | ≤80 W |
| Net Weight | 35 kg |
| Dimensions (W×D×H) | 420 × 600 × 470 mm |
| Gross Weight (incl. packaging) | 45 kg |
| Package Dimensions | 470 × 650 × 500 mm |
| Brand | Yuntang |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | YT-LR1 |
| Price Range | USD 1,600 – 5,300 (FOB) |
| Measurement Principle | Isoperibol Oxygen Bomb Calorimetry |
| Temperature Resolution | 0.0001 K |
| Thermal Capacity | 10,500 J/K |
| Ambient Temperature Range | 5–35 °C |
| Relative Humidity Limit | ≤80% RH |
| Ignition Voltage | 24 V DC |
| Ignition Duration | 5 s |
| Temperature Range | 0–40 °C |
| Power Consumption | ≤80 W |
| Supply | AC 220 V ±10%, 50 Hz ±1 Hz |
| Net Weight | 35 kg |
| Dimensions (W×D×H) | 420 × 600 × 470 mm |
| Packaged Weight | 45 kg |
| Packaged Dimensions | 470 × 650 × 500 mm |
| Brand | Yuntang |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | YT-QLC |
| Detection Principle | Coulometric Titration |
| Sulfur Range | 0.01–100% |
| Resolution | 0.001% |
| Combustion Temperature | 1150 °C (coal/coke), 900 °C (petroleum) |
| Temperature Control Accuracy | ±2 °C |
| Sample Mass | 50±5 mg (coal/coke), 100±10 mg (petroleum) |
| Sample Capacity | 1–13 positions per batch, with online sample insertion capability |
| Analysis Time | ~4 min per sample |
| Compliance | GB/T 214–2007 |
| Brand | ZEISS |
|---|---|
| Origin | Germany |
| Model | MY 5000 |
| Compliance | ISO 7404, GB/T 6948 |
| Measurement Principle | Polarized Light Microscopy + Photometric Reflectance Quantification |
| Reflectance Resolution | ≤ 0.01% R<sub>max</sub> |
| Measurement Speed | ≥ 1,000 points/min |
| Minimum Measurable Pore Diameter | 5 µm |
| Temperature Compensation | Automatic, traceable to 20 °C reference |
| Data Output Formats | CSV, Excel, Word, PDF |
| Software Compliance | FDA 21 CFR Part 11–ready audit trail, GLP/GMP-compatible metadata logging |
| Brand | Zhongke Aobo |
|---|---|
| Model | TL0610 |
| Temperature Range | Up to 1000 °C |
| Furnace Volume | 6 L |
| Heating Rate | <30 min (100 °C to 1000 °C) |
| Power Supply | AC 220 V, 16 A |
| Control Accuracy | ±1 °C |
| Thermal Insulation | Ceramic Fiber |
| Heating Element | HRE Resistance Wire |
| Thermocouple Type | K |
| Net Weight | 50 kg |
| Compliance | ASTM D3174, ISO 3987, GB/T 212–2008 |