Colorimeter
Filter
Showing 31–60 of 76 results
| Brand | Lovibond (Tintometer Ltd.) |
|---|---|
| Origin | United Kingdom |
| Model | AF325 |
| Light Path | 113 mm |
| Standard Scale Range | 0–250 mg Pt/L (APHA/Hazen) |
| Compliant Standards | ASTM D1209, ISO 2211, ISO 6271, AOCS Td 1b-64, BS 5339 |
| Sample Compatibility | Clear, pale-yellow liquids |
| Calibration Method | Nessleriser 2150 comparator disc system |
| Scale Segments | NSH (10–90), NSB (70–250) |
| Brand | Lovibond (Tintometer Ltd.) |
|---|---|
| Origin | United Kingdom |
| Model | AF327 |
| Measuring Range | 0–70 mg Pt/L (Platinum-Cobalt Units) |
| Cell Path Length | 288 mm |
| Standard Discs | 1209/1 (0–30 APHA), 1209/2 (30–70 APHA) |
| Compliant Standards | ASTM D1209, ISO 2211, ISO 6271, AOCS Td 1b-64, BS 5339 |
| Brand | Lovibond (Tintometer Ltd.) |
|---|---|
| Origin | United Kingdom |
| Model | AF328 |
| Measuring Range | 0–70 mg Pt/L (Platinum-Cobalt Units) |
| Cell Path Length | 250 mm |
| Standard Discs | CAA (0–30 APHA), CAB (30–70 APHA) |
| Compliant Standards | ASTM D1209, ISO 2211, ISO 6271, AOCS Td 1b-64, BS 5339 |
| Brand | Lovibond (Tintometer Ltd.) |
|---|---|
| Origin | United Kingdom |
| Model | AF329 |
| Measuring Range | 0–250 mg Pt/L (APHA/Pt-Co Scale) |
| Cell Pathlengths | 113 mm and 250 mm |
| Standard Discs | CAA (0–30), CAB (30–70), NSB (70–250) |
| Compliant Standards | ASTM D1209, AOCS Td 1b-64, ISO 2211, ISO 6271, BS 5339 |
| Brand | Lovibond (Tintometer) |
|---|---|
| Origin | United Kingdom |
| Model | AF607 |
| Light Source | CIE Illuminant B (Tungsten-Halogen Lamp) |
| EBC Scale Range | 2–27 |
| Resolution | 0.5 EBC units (2–10), 1.0 EBC unit (10–27) |
| Viewing Method | Triple-Field Visual Comparison |
| Compliance | EBC Method No. 4.1.1 (European Brewery Convention), ISO 4833-1:2013 (referenced for color standardization in fermented beverages) |
| Optical Path Options | Standard 10 mm, optional 20 mm and 50 mm cuvettes for extended range dilution |
| Brand | Lovibond (Tintometer) |
|---|---|
| Origin | United Kingdom |
| Model | AF650 |
| Measurement Range | 0.5–8.0 ASTM Colour Scale |
| Light Source | 12 V / 20 W Halogen Tungsten Lamp (CIE Illuminant C) |
| Viewing Geometry | Triple-Field Visual Comparison |
| Cell Path Length | 33 mm |
| Standard Discs | Two Rotating Glass Filter Discs (Disc 1: 0.5, 1.5, ..., 7.5 |
| Disc 2 | 1.0, 2.0, ..., 8.0) |
| Compliance | ASTM D1500, ISO 2049, IP 196, DIN 51578, BS 5859, JIS K 2580, NF T60-104, NBN T52-109, FTM 719-102 |
| Certification | CE |
| Brand | Lovibond / Tintometer |
|---|---|
| Origin | United Kingdom |
| Model | AF710-3 |
| Compliance | AOCS Cc 13b-45, ASTM E313, ASTM D848 |
| Sample Cell | Flat-bottom glass tube with calibrated oil column markings at ½", 1", and 5¼" |
| Optical Path | Fixed-path visual comparison system |
| Color Scale | AOCS-Tintometer® RY (Red-Yellow) scale, distinct from standard Lovibond® RYBN |
| Light Shielding | Integrated dual-tube holder with side-light exclusion design |
| Intended Use | Visual color assessment of transparent to semi-transparent liquids in edible oils, fats, petrochemicals, waxes, and distilled spirits |
| Brand | Lovibond (Tintometer) |
|---|---|
| Origin | United Kingdom |
| Model | Comparator 2000 Series |
| Compliance Standards | ASTM D1209, ASTM D1500, ASTM D6045, ISO 2049, IP 196, EBC, IFU, Ph. Eur. 2.2.2, USP, DIN 6162, IMSI |
| Light Source Compatibility | Daylight 2000 Illumination System (optional, recommended for critical measurements) |
| Measurement Principle | Visual color comparison against standardized glass color standards |
| Application Scope | Pharmaceuticals, Clinical Diagnostics, Food & Beverage, Petrochemicals, Water & Wastewater, Edible Oils & Fats |
| Brand | Lovibond (Tintometer) |
|---|---|
| Origin | United Kingdom |
| Model | Comparator 3000 Series |
| Measurement Principle | Tristimulus Visual Comparison Against Certified Glass Standards |
| Light Source | CIE-A Compliant Halogen Tungsten Lamp (2856 K) |
| Viewing Field | Triple-Field Simultaneous Comparison |
| Standard Compliance | ASTM D1544, ASTM D1500, ASTM D6045, AOCS Cc 13a-43, DIN EN ISO 4630-1, GB/T 4928-2001, ISO 2049, IP 196 |
| Optical Path Lengths | 10.65 mm (Gardner, FAC), 25 mm (EBC), 33 mm (ASTM) |
| Included Accessories | Model-Specific Certified Glass Color Discs, Calibration Certificate Traceable to NPL/UKAS |
| Brand | Lovibond (Tintometer) |
|---|---|
| Origin | UK |
| Model | EC2000 & EC3000 |
| EC2000 Pt-Co Range | 0–500 Pt-Co, Resolution: 1 Pt-Co, Repeatability: ±3% or ±1 Pt-Co, Path Length: 50 mm, Standard: ASTM D1209 |
| EC2000 Gardner Range | 0–18 Gardner, Resolution: 0.1 Gardner, Repeatability: ±0.2 Gardner, Path Length: 10 mm, Standard: ASTM D1544, D6166 |
| EC3000 ASTM Range | 0–8 ASTM, Resolution: 0.1 ASTM, Repeatability: ±0.1 ASTM, Path Length: 33 mm, Standard: ASTM D1500, D6045 |
| EC3000 Saybolt Range | −16 to +30 Saybolt, Resolution: 1 Saybolt, Repeatability: ±1 Saybolt, Path Length: 50 mm, Standard: ASTM D156, D6045 |
| Viewing Field | 2-field (EC2000), 3-field (EC3000) |
| Cuvettes | Plastic and glass W100 cells in multiple path lengths (10 mm, 33 mm, 50 mm) |
| Calibration Standards | Bottled reference liquids (60 mL) and certified interference filters |
| Brand | Lovibond (Tintometer) |
|---|---|
| Origin | United Kingdom |
| Model | EC2000 & EC3000 |
| Light Source | White LED (25-year lifetime) |
| Detector | Trichromatic sensor |
| Display | 3.5-inch TFT color LCD, 320×240 resolution, 24-bit color depth |
| Operation Modes | Resistive touchscreen + physical keypad |
| Sample Holder | W100-series cuvette slots (for EC and W100 cuvettes) |
| Housing | Flame-retardant ABS, 106 × 210 × 57 mm (W × D × H) |
| Interface | USB 2.0 (Mini-B) |
| Power Supply | 4 × AA batteries or USB bus power |
| Storage Capacity | ≥20,000 test results |
| Max. Sample Temperature | 80 °C |
| EC2000 Pt-Co Range | 0–500 Pt-Co, Resolution: 1 Pt-Co, Repeatability: ±3% or ±1 Pt-Co (whichever greater), Pathlength: 50 mm, Standard: ASTM D1209 |
| EC2000 Gardner Range | 0–18 Gardner, Resolution: 0.1 Gardner, Repeatability: ±0.2 Gardner, Pathlength: 10 mm, Standards: ASTM D1544, D6166 |
| EC3000 ASTM D1500 Range | 0–8, Resolution: 0.1, Repeatability: ±0.1, Pathlength: 33 mm, Standards: ASTM D1500, D6045 |
| EC3000 Saybolt Range | −16 to +30 Saybolt, Resolution: 1 Saybolt, Repeatability: ±1 Saybolt, Pathlength: 50 mm, Standards: ASTM D156, D6045 |
| Viewing Field | Dual-field (EC2000) / Triple-field (EC3000) |
| Cuvettes | W100 plastic and glass cuvettes (50 mm, 33 mm, 10 mm pathlengths) |
| Calibration Standards | Pre-filled 60 mL reference solutions and certified EC-series interference filters |
| Brand | Lovibond (Tintometer) |
|---|---|
| Origin | United Kingdom |
| Model | EC2000 Gardner |
| Measurement Range | 0–18 Gardner |
| Resolution | 0.1 Gardner |
| Repeatability | ±0.2 Gardner |
| Path Length | 10 mm |
| Compliance | ASTM D1544, ASTM D6166 |
| Viewing Field | Dual-field |
| Cuvettes | 3 × 10 mm plastic (W100), 1 × 10 mm glass (W100) |
| Calibration Standards | 60 mL reference liquid vial, certified filter set |
| Brand | Lovibond (Tintometer) |
|---|---|
| Origin | United Kingdom |
| Model | EC2000 Pt-Co |
| Measurement Range | 0–500 Pt-Co |
| Resolution | 1 Pt-Co |
| Repeatability | ±3% or ±1 Pt-Co (whichever is greater) |
| Path Length | 50 mm |
| Standard Compliance | ASTM D1209, ISO 6271, APHA Method 2120 B, USP <631> |
| Viewing Field | Dual-field (2-field) comparator display |
| Cuvettes | 3 × plastic 50 mm cuvettes (W100), 1 × glass 50 mm cuvette (W100) |
| Calibration Standards | 60 mL certified Pt-Co reference solution |
| Filter Set | Integrated certified interference filters (traceable to NPL/UKAS) |
| Brand | Lovibond (Tintometer) |
|---|---|
| Origin | United Kingdom |
| Model | EC3000 ASTM |
| Measurement Range | 0–8 ASTM units |
| Resolution | 0.1 unit |
| Repeatability | ±0.1 unit |
| Path Length | 33 mm |
| Standard Compliance | ASTM D1500, ASTM D6045 |
| Field of View | 3-field |
| Cuvette Types | Two 33 mm plastic cuvettes (W100), Two 33 mm glass cuvettes (W100) |
| Calibration Standards | Two 60 mL reference liquid standards |
| Filter Set | Two certified interference filters |
| Brand | Lovibond (Tintometer) |
|---|---|
| Origin | United Kingdom |
| Model | EC3000 Saybolt |
| Measurement Range | –16 to +30 Saybolt |
| Resolution | 1 Saybolt Unit |
| Repeatability | ±1 Saybolt Unit |
| Path Length | 50 mm |
| Standard Compliance | ASTM D156, ASTM D6045 |
| Field of View | Triple-field viewing system |
| Cuvettes | Two 50 mm plastic cuvettes (W100), two 50 mm glass cuvettes (W100) |
| Calibration Standards | Two 60 mL certified reference liquids |
| Filter Set | Two calibrated interference filters |
| Brand | Lovibond / Tintometer |
|---|---|
| Origin | United Kingdom |
| Model | ICx |
| Measurement Principle | Benchtop Transmittance Spectrophotometry |
| Standards Compliance | ASTM D1209, ASTM D5386, ISO 6271, ASTM E313 |
| Color Scales | Pt-Co/Hazen/APHA, CIEL*a*b*, Yellowness Index (YI) |
| Repeatability (Instrument) | ±0.5 Pt-Co (0–20), ±2 Pt-Co (>20) |
| Measurement Time | <10 s |
| Light Source | 12 V / 20 W Halogen Lamp (User-Replacable) |
| Sample Chamber | Sealed, Laser-Etched, Chemically Resistant |
| Optical Path Length Range | 0.1–152.4 mm |
| Display | 4.3" Full-Color LCD |
| Data Storage Capacity | >100,000 Measurements |
| Interface | USB, RS232 |
| Power Input | 110–250 V AC, 60 W, External 24 V Adapter |
| Dimensions (W×H×D) | 301 × 152 × 331 mm |
| Net Weight | 5.2 kg |
| Housing Material | Anodized Aluminum with Chemical-Resistant Textured Coating |
| Optical Components | Precision Glass Optics |
| Baseline Calibration | One-Touch Automatic |
| Illuminants & Observer | CIE Standard Illuminants A, C, D65 |
| Language Support | English, Chinese, French, German, Italian, Portuguese, Russian, Spanish, Japanese |
| Certifications | CE, RoHS, WEEE |
| Warranty | 2 Years (Excluding Light Source and Consumables) |
| Brand | Lovibond (Tintometer) |
|---|---|
| Origin | United Kingdom |
| Manufacturer Status | Authorized Distributor |
| Product Origin | Imported |
| Model | Model F |
| Price Range | USD 6,800 – 13,600 (FOB) |
| Color Scale | Lovibond RYBN |
| Red Scale | 0.1–79.9 |
| Yellow Scale | 0.1–79.9 |
| Blue Scale | 0.1–49.9 |
| Neutral Scale | 0.1–3.9 |
| Resolution | 0.1 Lovibond Unit |
| Light Source | Dual 12 V / 10 W Tungsten-Halogen Lamps |
| Illuminant Compliance | CIE Standard Illuminant C |
| Sample Chamber | Removable White Liner with Precision-Registered Cell Notch |
| Power Supply | External Low-Voltage DC Adapter |
| Brand | Lovibond/Tintometer |
|---|---|
| Origin | United Kingdom |
| Model | Model Fx (PFXeo) |
| Light Source | Tungsten-Halogen Lamp |
| Wavelength Range | 380–780 nm |
| Wavelength Accuracy | ±0.2 nm |
| Spectral Bandwidth | <15 nm |
| Photometric Range | 0–100% Transmittance (T) |
| Photometric Linearity | ±0.01% T |
| Stray Light | <0.01% T |
| Repeatability | ±0.5% T |
| Detector Type | Spectrophotometric |
| Housing Material | Anodized Aluminum |
| Dimensions | 301 mm (W) × 152 mm (H) × 331 mm (D) |
| Weight | 5.16 kg |
| Operating Environment | 5–40 °C, ≤90% RH (non-condensing) |
| Storage Environment | −20–85 °C, ≤90% RH (non-condensing) |
| Power Supply | 190–240 V AC |
| Data Interfaces | USB, RS-232 |
| Certifications | CE |
| Supported Languages | English, Chinese, French, German, Italian, Spanish, Portuguese, Russian, Japanese |
| Compliant Standards | ISO 15305, AOCS Cc 13b-45 / Cc 8d-55 / Cc 13j-97 / Cc 13e / Cc 13j, BS 684 Section 2.20, MS 252 Part 16, IP 17, GB/T 22460-2008, Lovibond® RYBN, Lovibond RY10:1 |
| Brand | Lovibond (Tintometer) |
|---|---|
| Origin | United Kingdom |
| Manufacturer Status | Authorized Distributor |
| Product Origin | Imported |
| Model | Model Fx |
| Price Range | USD 6,800 – 13,600 |
| Brand | Lovibond (Tintometer) |
|---|---|
| Origin | United Kingdom |
| Model | MODEL-F |
| Measurement Principle | Dual-field visual comparison against Lovibond® RYBN glass filter standards |
| Color Scale | Lovibond Red (R): 0.1–79.9, Yellow (Y): 0.1–79.9, Blue (B): 0.1–49.9, Neutral (N): 0.1–3.9 |
| Resolution | 0.1 Lovibond Unit |
| Light Source | Twin 12 V / 10 W tungsten-halogen lamps |
| Illumination | Daylight-mimicking (CIE Standard Illuminant C approx.) with integrated blue filter for spectral consistency |
| Optical System | Precision prism-based dual-view field with standardized viewing geometry |
| Sample Path Length | Adjustable from 0.1 to 153 mm (0.004 to 6 in) |
| Power Supply | 220 V AC / 12 V DC adapter |
| Dimensions & Weight | 330 × 410 × 230 mm |
| Certifications | CE compliant |
| Accessories | Interchangeable R/Y/B/N filter discs (e.g., Part Nos. 180200, 180300–180400), RYBN standard filter sets (184000–187000) |
| Brand | Lovibond (Tintometer) |
|---|---|
| Origin | United Kingdom |
| Product Type | Nesslerization-Compatible Glass Color Comparator Tubes |
| Model Designations | AF228, DB420, AF262, DB421, AF306, DB423, AF306/P, DB424/13.5 |
| Tube Format | Paired Sets (Matched Optical Path Length) |
| Material | Borosilicate Glass, ASTM E2020-22 Compliant |
| Nominal Path Length | 10 mm, 13.5 mm, 20 mm, 25 mm, 50 mm (Model-Dependent) |
| Calibration Traceability | NIST-Traceable Reference Standards Available |
| Compliance | ISO 7887, ASTM D1209, ASTM D5391, USP <631>, EN ISO 7887-2 |
| Brand | Lovibond (Tintometer Ltd.) |
|---|---|
| Origin | United Kingdom |
| Model | PFXi 950 |
| Compliance | ASTM D1209, ASTM D1500, ASTM D6045, AOCS Cd 13b-97, ISO 2761, ISO 4630, ISO 6271, Gardner ASTM D1544, Saybolt ASTM D156 |
| Measurement Principles | Transmission colorimetry using tungsten-halogen light source and precision interference filters |
| Display | High-resolution LCD with multilingual interface (including English & Chinese) |
| Sample Path Length Options | 10 mm, 20 mm, 33.3 mm, 50 mm, 100 mm |
| Output Data | CIE L*a*b*, CIE XYZ, CIE Yellowness Index (YI), Whiteness Index (WI), spectral reflectance/transmittance (380–720 nm, 10 nm intervals), and proprietary color scales |
| Connectivity | RS-232, USB, optional Ethernet |
| Software Compatibility | ColorSoft™ PC software for data export, audit trail, and report generation |
| Regulatory Support | FDA 21 CFR Part 11 compliant configuration available (with user authentication, electronic signatures, and full audit trail) |
| Brand | Lovibond (Tintometer) |
|---|---|
| Origin | United Kingdom |
| Model | PFXi-195 |
| Optical Configuration | 9-band interference filter photometer |
| Spectral Range | 420–710 nm |
| Spectral Bandwidth | 10 nm |
| Repeatability | Δx,y ≤ ±0.0004 |
| Measurement Time | <30 s |
| CIE Illuminants | A, B, C, D65 |
| Standard Observer Angles | 2°, 10° |
| Pathlength Range | 0.1–50 mm |
| Data Storage Capacity | 100,000 measurements |
| Interface | USB, LAN, RS232 |
| Display | 240 × 128 backlit LCD |
| Power Supply | 90–240 VAC (external adapter) |
| Dimensions (W×H×D) | 435 × 195 × 170 mm |
| Weight | 6.8 kg |
| Compliance | CE, RoHS, WEEE |
| Calibration | One-touch automated baseline calibration |
| Brand | Lovibond (Tintometer) |
|---|---|
| Origin | United Kingdom |
| Model | PFXi195 |
| Spectral Range | 420–710 nm |
| Spectral Bandwidth | 10 nm |
| Repeatability | ±0.0004 in CIE x,y chromaticity coordinates |
| Measurement Time | <30 s |
| Light Source | 5 V, 10 W tungsten-halogen lamp |
| Illuminants | CIE A, B, C, D65 |
| Observer Angles | 2° and 10° |
| Path Length Range | 0.1–50 mm |
| Data Interfaces | USB, LAN, RS232 |
| Data Storage Capacity | 100,000 measurements |
| Display | 240 × 128 backlit LCD |
| Keypad | 23 tactile membrane keys with audible feedback |
| Languages | English, Chinese, French, German, Italian, Portuguese |
| Housing Material | Steel with textured epoxy coating |
| Dimensions (W×D×H) | 435 × 195 × 170 mm |
| Weight | 6.8 kg |
| Compliance | CE, RoHS, WEEE |
| Built-in Color Scales | Pt-Co/Hazen/APHA, Gardner, Iodine, Saybolt, ASTM Color, FAC, EBC, ASBC, ICUMSA, Pfund, ADMI, EP, USP, CIE L*C*h, Hunter Lab, spectral reflectance/data |
| Brand | Lovibond (Tintometer) |
|---|---|
| Origin | United Kingdom |
| Model | PFXi195/1 |
| Spectral Range | 420–710 nm |
| Spectral Bandwidth | 10 nm |
| Repeatability | ±0.0004 in CIE x,y coordinates |
| Measurement Time | <30 s |
| Light Source | 5 V, 10 W Tungsten-Halogen Lamp |
| CIE Illuminants | A, B, C, D65 |
| Standard Observer Angles | 2°, 10° |
| Path Length Range | 0.1–50 mm |
| Data Interfaces | USB, LAN, RS232 |
| Data Storage Capacity | 100,000 measurements |
| Display | 240 × 128 backlit LCD |
| Keypad | 23 tactile polyester membrane keys with audible feedback |
| Operating Languages | English, Chinese, French, German, Italian, Portuguese |
| Housing Material | Steel with textured epoxy coating |
| Dimensions & Weight | 435 × 195 × 170 mm / 6.8 kg |
| Compliance | CE, RoHS, WEEE |
| Built-in Color Scales | Pt-Co/Hazen/APHA (ASTM D1209), Gardner (ASTM D1544/D6166), Iodine (DIN 6162), CIE XYZ/Lab, Spectral Reflectance Data |
| Brand | Lovibond (Tintometer) |
|---|---|
| Origin | United Kingdom |
| Model | PFXi195/2 |
| Spectral Range | 420–710 nm |
| Spectral Bandwidth | 10 nm |
| Repeatability | ±0.0004 in CIE x,y chromaticity coordinates |
| Measurement Time | <30 s |
| Light Source | 5 V, 10 W tungsten-halogen lamp |
| Illuminants | CIE A, B, C, D65 |
| Observer Angles | 2° and 10° |
| Pathlength Range | 0.1–50 mm |
| Data Interfaces | USB, LAN, RS232 |
| Internal Memory | 100,000 measurements |
| Display | 240 × 128 backlit LCD |
| Keypad | 23 tactile polyester membrane keys with audible feedback |
| Languages | English, Chinese, French, German, Italian, Portuguese |
| Housing | Powder-coated steel enclosure |
| Dimensions & Weight | 435 × 195 × 170 mm / 6.8 kg |
| Compliance | CE, RoHS, WEEE |
| Built-in Color Scales | Saybolt (ASTM D6045/D156), ASTM D1500, Pt-Co/Hazen/APHA (ASTM D1209), CIE XYZ/Lab values, spectral reflectance data |
| Brand | Lovibond |
|---|---|
| Origin | United Kingdom |
| Model | PFXi195/3 |
| Spectral Range | 420–710 nm |
| Spectral Bandwidth | 10 nm |
| Repeatability (CIE x,y) | ±0.0004 |
| Measurement Time | <30 s |
| Light Source | 5 V, 10 W Tungsten-Halogen Lamp |
| CIE Illuminants | A, B, C, D65 |
| Observer Angles | 2°, 10° |
| Path Length Range | 0.1–50 mm |
| Data Interfaces | USB, LAN, RS232 |
| Data Storage Capacity | 100,000 measurements |
| Display | 240 × 128 pixel backlit LCD |
| Keypad | 23 tactile polyester membrane keys with audible feedback |
| Housing Material | Steel enclosure with textured epoxy coating |
| Dimensions (W×H×D) | 435 × 195 × 170 mm |
| Weight | 6.8 kg |
| Compliance | CE, RoHS, WEEE |
| Brand | Lovibond (Tintometer) |
|---|---|
| Origin | United Kingdom |
| Model | PFXi880 / PFXi950 / PFXi995 |
| Spectral Range | 420–710 nm |
| Spectral Bandwidth | 10 nm |
| Colorimetric Repeatability | Δx,y ≤ ±0.0002 |
| Measurement Time | <30 s |
| Light Source | 5 V, 10 W Tungsten-Halogen Lamp |
| CIE Illuminants | A, B, C, D65 |
| Standard Observer Angles | 2°, 10° |
| Pathlength Range | 0.1–153 mm (0.004–6 in) |
| Filter Set | 16 Interference Filters |
| Data Storage Capacity | 100,000 Measurements |
| Interface | USB, LAN, RS232 |
| Display | 240 × 128 Backlit LCD |
| Keypad | 23 Membrane Keys with Audible Feedback |
| Language Support | English, Chinese, French, German, Italian, Portuguese, Russian, Spanish, Japanese |
| Power Supply | 90–240 V AC (External Adapter) |
| Dimensions | 515 × 196 × 170 mm |
| Weight | 7.7 kg |
| Compliance | CE, RoHS, WEEE |
| GLP Features | Timestamped Audit Trail, User ID, Sample ID, Calibration Log |
| Brand | Lovibond (Tintometer) |
|---|---|
| Origin | United Kingdom |
| Model | PFXi 950/P |
| Spectral Range | 420–710 nm |
| Spectral Bandwidth | 10 nm |
| Repeatability | ±0.0002 in CIE x,y chromaticity coordinates |
| Measurement Time | <30 s |
| Path Length Range | 0.1–153 mm (0.004–6 in) |
| Light Source | 5 V, 10 W Tungsten-Halogen Lamp |
| CIE Illuminants | A, B, C, D65 |
| Standard Observer Angles | 2°, 10° |
| Built-in Color Scales | ASTM D1500 (Petroleum), Saybolt, CIE L*a*b*, L*C*h*, Yellowness Index (ASTM E313), Whiteness Index (CIE/ISO 11475), and Spectral Data Output |
| Calibration | One-Touch Automatic Baseline Calibration |
| Data Storage Capacity | 100,000 measurements |
| Interface Options | USB, LAN, RS232 |
| Display | 240 × 128 backlit LCD |
| Keypad | 23 tactile membrane keys with audible feedback, polyester overlay |
| Operating Languages | English, Chinese, French, German, Italian, Portuguese, Russian, Spanish, Japanese |
| Housing | Steel chassis with textured epoxy coating |
| Dimensions (W×H×D) | 515 × 195 × 170 mm |
| Weight | 7.7 kg |
| Compliance | CE, RoHS, WEEE |
| Optional Heated Cell Holder | Up to 95 °C temperature control |
| Brand | Lovibond (Tintometer) |
|---|---|
| Origin | United Kingdom |
| Model | PFXi995 |
| Spectral Range | 420–710 nm |
| Spectral Bandwidth | 10 nm |
| Repeatability | ±0.0002 in CIE x,y coordinates |
| Measurement Time | <30 s |
| Optical Path Length | 0.1–153 mm |
| Light Source | 5 V, 10 W tungsten-halogen lamp |
| CIE Illuminants | A, B, C, D65 |
| Observer Angles | 2°, 10° |
| Data Storage Capacity | 100,000 measurements |
| Interface | USB, LAN, RS232 |
| Display | 240 × 128 backlit LCD |
| Keypad | 23 tactile polyester membrane keys with audible feedback |
| Optional Heater | Up to 95 °C |
| Operating Voltage | 90–240 VAC (external power supply) |
| Enclosure | Steel housing with textured epoxy coating |
| Dimensions & Weight | 515 × 195 × 170 mm / 7.7 kg |
| Compliance | CE, RoHS, WEEE |
| Built-in Color Scales | Lovibond RYBN, AOCS, Gardner, Pt-Co/Hazen/APHA, FAC, Chlorophyll A/B, β-Carotene, Iodine, Hess-Weis, Klett (Blue filter KS-42), Kreis, CIE XYZ/L*a*b*, spectral reflectance data |