Combined Temperature Humidity Vibration Test Chamber
Filter
Showing 31–60 of 191 results
| Brand | Other Brands |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Price | USD 21,500 (FOB) |
| Compliance | IEC 60068-2-6, IEC 60068-2-14, IEC 60068-2-30, ISO 16750-4, MIL-STD-810H (Environmental Engineering Considerations) |
| Brand | OEM / Custom-Built |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Price | USD 21,500 (FOB) |
| Temperature Range | −70°C to +180°C |
| Humidity Range | 10%–98% RH |
| Vibration Interface | ISO 10816-compliant mounting flange (standard), compatible with electrodynamic shakers up to 10 kN force |
| Control System | 7″ or 10″ capacitive touchscreen HMI with real-time PID tuning, Ethernet/RS-485 communication, data logging (SD card & USB), alarm notification via email/SMS |
| Construction | Interior – mirror-finish 304 stainless steel (TIG-welded seams) |
| Compliance | Meets ASTM D4332, IEC 60068-2-1, -2-2, -2-30, -2-64 |
| Brand | Other Brands |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Price | USD 21,500 (FOB) |
| Cooling Medium | R404A |
| Heating System | Stainless Steel (SUS#304) Immersion-Type Electric Heaters with PTFE Coating |
| Humidification System | SUS#304 Steam Generator with Level Sensor & Solenoid Valve |
| Water Reservoir | 25 L Integrated Drawer-Type Tank with Auto-Replenishment |
| Air Circulation | Multi-Blade Centrifugal Fan with Sealed Motor & Adjustable Horizontal/Vertical Outlet Dampers |
| Refrigeration | Dual-Stage Cascade System with Air-Cooled Condenser (Optional Water-Cooled) |
| Safety Features | Low-Water-Level Cut-off, Over-Temperature Protection, Visual Alarm Indicator, Low-Conductivity Electrolyte Warning |
| Brand | Other Brands |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Price | USD 21,500 (FOB) |
| Key | Temperature Range: -70°C to +150°C |
|---|---|
| Humidity Range | 5–98% RH (standard: 20–98% RH) |
| Temperature Resolution & Uniformity | ±0.1°C / ±2.0°C |
| Humidity Resolution & Uniformity | ±0.1% RH / ±3.0% RH |
| Temperature Control Accuracy | ±0.5°C |
| Humidity Control Accuracy | ±2.5% RH |
| Heating Rate | ~4.0°C/min |
| Cooling Rate | ~1.0°C/min |
| Construction | Interior & Exterior – SUS304 stainless steel |
| Insulation | High-density polyurethane foam (chlorinated ethyl carbamate-based, high-temp resistant) |
| Refrigeration System | Air-cooled |
| Safety Protections | Fuseless circuit breaker, compressor overload protection, refrigerant HP/LP cut-off, over-temperature/over-humidity safeguards, fuse, fault alarm system, low-water warning |
| Controller | Touchscreen LCD with bilingual (EN/CN) interface, 100 programmable profiles × 1000 segments × 999 cycles, max segment duration: 99h 59m, screen lock function, real-time curve display, RS-232/RS-485 interface for PC-based programming and remote monitoring |
| Structural Features | A3 carbon steel outer shell with powder coating, SUS304 mirror-finish inner chamber, double-layer high-tensile silicone gasket seal, anti-rebound door handle, multi-layer laminated tempered glass viewport with conductive ITO film, Ø50 mm cable port (left side), removable vibration table mounted on precision linear rails, low-noise Sanyo Denki blower with multi-wing centrifugal impeller, epoxy-silicone hybrid sealing between shaker table and chamber base |
| Key | Brand: Other Brands |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Price | USD 21,000 (FOB) |
| Compliance | GB/T 2423.1–2008, GB/T 2423.2–2008, GB/T 2423.3–2006, GB/T 2423.10–1999, JJG 190–1997 |
| Brand | Other Brands |
|---|---|
| Origin | Imported |
| Manufacturer Type | General Distributor |
| Price | USD 21,500 (FOB) |
| Temperature Range | −70°C to +180°C |
| Humidity Range | 10%–98% RH |
| Vibration Frequency Range | 5–3000 Hz |
| Max Sinusoidal Force | 14.2 kN |
| Max Random Force (rms) | 14.2 kN |
| Max Acceleration | 1000 m/s² |
| Max Velocity | 2.00 m/s |
| Max Displacement (p-p) | 51 mm |
| Payload Capacity | 300 kg |
| Refrigeration System | Twin-stage cascade refrigeration with French Tecumseh compressors |
| Humidity Control | Steam generator + ultrasonic humidifier |
| Structural Insulation | High-density fiberglass wool |
| Internal Chamber Material | SUS304 stainless steel mirror finish |
| External Frame | A3 steel with epoxy powder coating |
| Key | Temperature Range Options: -20°C to 150°C |
|---|---|
| Humidity Range | 20–98% RH |
| Temperature Uniformity | ≤ ±0.5°C |
| Temperature Stability | ≤ ±2°C |
| Humidity Deviation | +2 / –3% RH |
| Heating Rate (–20°C → 100°C) | ~35 min |
| Cooling Rate (25°C → –40°C) | ~50 min |
| Vibration System | Electrodynamic Shaker (OK-ES), Sinusoidal/Random/Shock Control, Vertical Magnesium Alloy Table (VT0404), Accelerometer (BW), DA-6 Power Amplifier, Excitation Supply, RS232 & USB Data Interface |
| Optional Add-ons | LN2V Liquid Nitrogen Rapid Cooling Unit, LHC Low-Humidity Sensor with Regenerative Desiccant Dryer |
| Compliance | Designed for IEC 60068-2, MIL-STD-810, ASTM D4332, ISO 16750-4, and GLP/GMP-aligned test documentation workflows |
| Brand | OEM / Custom-Built |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Price | USD 21,500 (FOB) |
| Temperature Range | −70°C to +180°C |
| Humidity Range | 10%–98% RH |
| Vibration System | Electrodynamic Shaker with Hydraulic Assist |
| Max. Payload | 1,000 kg |
| Table Surface | 2090 × 1600 × 1615 mm (L×W×H) |
| Enclosure Height | 1000 mm |
| Vibration Mode | Reciprocating (Rotary Eccentric Drive) |
| Frequency Range | 1–600 Hz |
| Displacement Peak-to-Peak | 25.4 mm |
| Acceleration Range | 0.5–100 g (adjustable) |
| Sweep Type | Logarithmic & Linear |
| Programmable Timer | 0.1 s – 99 h 59 min |
| Power Supply | 380 V / 220 V, 50 Hz, 3-Phase |
| Total Weight | 1200 kg |
| Compliance | ASTM D999, ISTA 3A/3E/3F, EN 71-1, UL 60950-1, ISO 16750-3, IEC 60068-2-6 & -2-64 |
| Brand | Other Brands |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Internal Volume | Customizable (L) |
| Temperature Range | -70 °C to +150 °C |
| Temperature Uniformity | ≤2 °C |
| Temperature Stability | ≤±0.5 °C |
| Temperature Deviation | ≤±2 °C |
| Humidity Range | 20–98 %RH (at +20 °C to +80 °C) |
| Humidity Tolerance | ≤±3 %RH (≤75 %RH), ≤±5 %RH (>75 %RH) |
| Rapid Thermal Range | -55 °C to +85 °C |
| Ramp Rate | 5 °C/min or 10 °C/min (average or linear mode) |
| Inner Liner | Mirror-finish SUS304 stainless steel |
| Outer Casing | Brushed SUS304 or galvanized cold-rolled steel |
| Insulation | Glass fiber wool / rigid polyurethane foam |
| Heating System | Ni-Cr alloy electric heaters |
| Cooling System | Twin-stage mechanical refrigeration (Bizerba semi-hermetic compressors) |
| Refrigerants | HFC-R404A / HFC-R23 |
| Condenser | Stainless steel brazed plate heat exchanger |
| Air Circulation | Forced convection via centrifugal fan, bottom-in top-out airflow |
| Humidification | Built-in water tank with booster pump |
| Control System | PLC-based programmable controller with bilingual (English/Chinese) color touchscreen interface |
| Vibration Subsystem | Optional electrodynamic or servo-hydraulic shaker system (custom-configured per user requirements) |
| Compliance Standards | GB/T 5170.2, GB/T 2423.1–2423.3, GJB 150.3–150.4 |
| Key | Temperature Range: -20°C to +130°C |
|---|---|
| Temperature Uniformity | ±2°C (unloaded) |
| Temperature Fluctuation | ±0.5°C (unloaded) |
| Humidity Range | 40–98% RH |
| Humidity Fluctuation | ±2% RH |
| Temperature Deviation | ≤±2°C |
| Humidity Deviation | ≤±2% RH |
| Heating Rate | -20°C to +120°C ≤ 60 min (unloaded) |
| Cooling Rate | Ambient to -20°C ≤ 45 min (unloaded) |
| Vibration Force (Sine) | 2.94 kN (300 kgf) |
| Frequency Range | 5–2000 Hz |
| Max Acceleration | 980 m/s² (100 g) |
| Max Velocity | 1.1 m/s |
| Max Displacement | 25 mm p-p |
| Moving Mass | 2.7 kg |
| Payload Capacity | 120 kg |
| Table Diameter | 150 mm |
| Vibration Axis | Vertical (Z-axis) |
| Timer Range | 0–999 h |
| Compliance | GB/T 2423.1, GB/T 2423.3, GB/T 2423.4, IEC 60068-2-1, IEC 60068-2-3, IEC 60068-2-30 |
| Key | Vibration Table Dimensions (L×W): 30×30 / 50×50 / 75×75 / 100×100 cm |
|---|---|
| Cabinet Dimensions (L×H×W) | Vertical Mode: 30×15×30 to 100×20×100 cm |
| Horizontal Mode | 30×25×30 to 100×25×100 cm |
| Temperature Range | −100 °C to +180 °C |
| Temperature Uniformity | ≤ ±2 °C |
| Temperature Stability | ≤ ±0.5 °C |
| Control Accuracy | ±1.0 °C |
| Ramp Rate | ≥60 °C/min |
| Vibration Axes | Triaxial, 6-DOF |
| Frequency Range | 10–5,000 Hz (pseudo-random acceleration profile) |
| Acceleration Range | 1–50 g |
| Max Vibration Table Surface | 1220 mm × 1220 mm |
| LN₂ Consumption | 50 L/min |
| Operating Ambient | +5 °C to +35 °C |
| Key | Brand: Other Brands |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Price | USD 21,500 (FOB) |
| Temperature Range | −70 °C to +150 °C |
| Humidity Range | 5–98% RH |
| Temp. Control Accuracy | ±0.5 °C |
| Humidity Control Accuracy | ±2.5% RH |
| Temp. Ramp Rate | Up to 4.0 °C/min (heat), 1.0 °C/min (cool) |
| Vibration Interface | Customizable electrodynamic or servo-hydraulic shaker integration |
| Controller | LCD Touchscreen with R232/RS485 interface |
| Compliance | Designed per IEC 60068-2-6, -14, -30 |
| Brand | OEM / Custom-Built |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Price | USD 21,500 (FOB) |
| Internal Volume | 120 L / 250 L / 500 L |
| Internal Dimensions (W×D×H, mm) | 400×550×700 |
| Temperature Range | −40 °C to +150 °C or −60 °C to +150 °C |
| Temp. Uniformity | ≤ ±2.0 °C |
| Temp. Stability | ±0.5 °C |
| Humidity Range | 30–98% RH |
| Humidity Tolerance | ±5% RH (<75% RH) |
| Vibration Interface | Isolated stainless-steel mounting platform with elastomeric sealing gasket |
| Compliance | GB/T 2423.1–2008, GB/T 2423.2–2008, GB/T 2423.3–2006, GB/T 2423.10–1999, JJG 190–1997 |
| Brand | OEM Industrial Grade |
|---|---|
| Origin | Imported (EU/JP Engineering Design) |
| Manufacturer Type | Authorized Distributor |
| Quotation | USD 21,500–48,000 (FOB, depending on configuration and chamber volume) |
| Key | Temperature Range: -60°C to +150°C |
|---|---|
| Temperature Uniformity | ≤ ±2°C |
| Temperature Stability | ±0.5°C |
| Temp. Deviation | ≤ ±2°C |
| Ramp Rate | 0.7–1.0°C/min |
| Time Setting Range | 0–9999 h |
| Vibration Force (Sine) | 2.94 kN (300 kgf) |
| Frequency Range | 5–500 Hz |
| Max Acceleration | 980 m/s² (100 g) |
| Max Velocity | 1.1 m/s |
| Max Displacement | 25 mm p-p |
| Moving Mass | 2.7 kg |
| Payload Capacity | 120 kg |
| Table Surface | 150 mm × 150 mm |
| Vibration Axis | Vertical (Z-axis only) |
| Power Supply | AC 380 V ±10%, 50 Hz, 3-phase 5-wire |
| Refrigeration | Twin-stage mechanical cascade system with R404A/R23 refrigerants |
| Compressor | Semi-hermetic Copeland (Germany) |
| Cooling Method | Water-cooled |
| Humidity Control | Built-in stainless steel water tank with booster pump |
| Air Circulation | Wide-band forced convection via extended-shaft centrifugal blower, bottom-in/top-out airflow |
| Control System | PLC-based programmable controller with bilingual (EN/CN) color touchscreen (OYO or TIME) |
| Compliance | GB/T 5170.2, GB/T 2423.1–3, GJB 150.3–4 |
| Key Features | 350×350 mm customizable vibration table surface |
|---|---|
| Load capacity options | 25 / 50 / 75 / 100 kg |
| Vibration axis | vertical, horizontal, or simultaneous dual-axis |
| Frequency range | 1–600 Hz / 1–3000 Hz / 1–5000 Hz (model-dependent) |
| Displacement amplitude | 0–5 mm peak-to-peak |
| Maximum acceleration | <20 g |
| Programmable test duration | 0–9999 h/min/sec |
| Frequency resolution | 0.01 Hz, accuracy ±0.1 Hz |
| Power supply | AC220V/50Hz or AC380V/50Hz |
| Key | Function Modes: Programmable, Sweep, Time-Controlled |
|---|---|
| External Dimensions (approx.) | 500 × 200 × 500 mm (H × W × D) |
| Vibration Axis | Vertical (Horizontal optional) |
| Max. Load Capacity | 60 kg |
| Frequency Range | 1–400 Hz (Programmable in 0.01 Hz increments) |
| Acceleration | Up to 20 g (peak) |
| Displacement Amplitude | 0–5 mm p-p (adjustable) |
| Vibration Waveform | Sinusoidal |
| Drive Power | 2.2 kW |
| Frequency Resolution & Accuracy | 0.01 Hz display / ±0.1 Hz accuracy |
| Time Control Unit | Second-level programmability |
| Input Voltage | 220 V ±20% |
| Max. Current Draw | 5 A |
| Platform Options | 250×250 mm to 800×800 mm |
| Max. Shock Acceleration (optional high-shock mode) | Up to 650 g |
| Max. Shock Velocity Change | 7.4 m/s (HS mode) |
| Max. Shock Pulse Duration | 1–3 ms (selectable) |
| Compressed Air Requirement | 6–8 kgf/cm² |
| Compliance | Designed for ISO 16750-3, IEC 60068-2-64, MIL-STD-810H, GB/T 2423.10, GB/T 2423.34 |
| Key | Temperature Range: -20°C to +150°C / -40°C to +150°C / -60°C to +150°C |
|---|---|
| Temperature Uniformity | ≤ ±2°C |
| Temperature Fluctuation | ±0.5°C |
| Temperature Deviation | ≤ ±2°C |
| Ramp Rate | 0.7–1.0°C/min |
| Time Setting Range | 0–9999 h |
| Sinusoidal Force Capacity | 2.94 kN (300 kgf) |
| Frequency Range | 5–500 Hz |
| Max Acceleration | 980 m/s² (100 g) |
| Max Velocity | 1.1 m/s |
| Max Displacement | 25 mm p-p |
| Moving Mass | 2.7 kg |
| Payload Capacity | 120 kg |
| Table Surface | 150 mm × 150 mm |
| Vibration Axis | Vertical (Z-axis only) |
| Power Supply | AC 380 V ±10%, 50 Hz, 3-phase 5-wire |
| Refrigeration | Dual-stage cascade system with French Tecumseh hermetic compressors |
| Humidity Control | Steam generator + precision PID humidity controller |
| Construction | A3 steel exterior with powder coating |
| Sealing | Dual-layer high-tension silicone gasket |
| Compliance | Designed per IEC 60068-2-6, IEC 60068-2-14, IEC 60068-2-30, ISO 16750-4, MIL-STD-810H (vibration & environmental profiles) |
| Key | Vibration Frequency Range: 100–300 rpm (continuous adjustment, ASTM-compliant) |
|---|---|
| Vibration Amplitude | 25.4 mm (1 inch) |
| Max Payload Capacity | 60 kg (standard), up to 100 kg (customizable) |
| Operating Time Range | 0–9999 h / min / sec |
| Motor Power | 1 HP (746 W) |
| Max Current Draw | 4 A |
| Worktable Dimensions | 1000 × 1200 mm (standard, customizable) |
| Base Frame | Structural steel channel (100 × 50 mm), 6 mm powder-coated steel top plate |
| Test Platform | 10 mm anodized aluminum plate |
| Main Mast | Solid 45# steel, surface-hardened, 1900 mm total length, Ø95 mm |
| Primary Drive Rod | Solid 60# steel leadscrew with hardened nut assembly, 1700 mm effective stroke, Ø30 mm |
| Fixture Rod | Solid 45# steel, surface-hardened, 1000 mm length, Ø15 mm |
| Standard Fixture | Six-point adjustable corner clamping system with hardened steel angle brackets |
| Compliance | Designed per ASTM D999, ASTM D3580, ISO 2247, ISO 8767, and EN 1185 for transport simulation testing |
| Key | Vibration Frequency Range: 100–300 rpm |
|---|---|
| Amplitude | 25.4 mm (1 in) |
| Max Load Capacity | 100 kg (customizable) |
| Operating Time | Up to 9999 h/min/sec |
| Motor Power | 1 HP |
| Rated Current | 4 A |
| Worktable Dimensions | 100 cm × 120 cm (customizable) |
| Compliance | ASTM D999, ISTA 3A/3E, EN 15308, ANSI MH1, UL 60730 |
| Humidity Control | Integrated vapor compression + steam injection system |
| Temperature Range | −70°C to +180°C (typical configuration) |
| Humidity Range | 10–98% RH (non-condensing) |
| Key | Table Size: 350 × 350 mm (customizable) |
|---|---|
| Max Load Capacity | 25 / 50 / 75 / 100 kg |
| Vibration Axis | Vertical, Horizontal, or Dual-Axis (selectable) |
| Frequency Range | 1–600 Hz / 1–3000 Hz / 1–5000 Hz |
| Peak-to-Peak Displacement | 0–5 mm (5 mm p-p) |
| Max Acceleration | <20 g |
| Frequency Resolution | 0.01 Hz, Accuracy: ±0.1 Hz |
| Power Supply | AC 220 V / 50 Hz or AC 380 V / 50 Hz |
| Compliance | GB/T 2423.10 |
| Operating Ambient | 15–35 °C, ≤85% RH, Non-corrosive, Low-EMI Environment |
| Key | Temperature Range: -20 °C to 150 °C |
|---|---|
| Optional Ranges | -40 °C to 150 °C |
| Temp. Uniformity | ≤ ±2 °C |
| Temp. Fluctuation | ±0.5 °C |
| Temp. Deviation | ≤ ±2 °C |
| Ramp Rate | 0.7–1.0 °C/min |
| Time Setting Range | 0–9999 h |
| Vibration Force (Sine) | 2.94 kN (300 kgf) |
| Frequency Range | 5–500 Hz |
| Max. Acceleration | 980 m/s² (100 g) |
| Max. Velocity | 1.1 m/s |
| Max. Displacement | 25 mm p-p |
| Moving Mass | 2.7 kg |
| Payload Capacity | 120 kg |
| Tabletop Size | 150 mm × 150 mm |
| Vibration Axis | Vertical (Z-axis) |
| Power Supply | AC 380 V ±10%, 50 Hz, 3-phase 5-wire |
| Refrigeration | Dual-stage cascade system with Copeland/Tecumseh-compatible compressors, Danfoss filter-driers, and Castel solenoid valves |
| Internal Dimensions (L×W×H) | 500×600×750 mm (OK-ZTH-225) |
| Key | Construction Material: SUS#304 stainless steel interior & exterior |
|---|---|
| Insulation | High-density polyurethane foam (chlorinated ethyl carbamate-based, high-temp resistant) |
| Cooling System | Air-cooled |
| Temperature Range | −70 °C to +150 °C (selectable low-temp tiers: −70/−60/−40/−20/0/25 °C |
| high-temp options | 100 °C or 150 °C) |
| Humidity Range | 5–98% RH (standard: 20–98% RH |
| Temp/Humidity Resolution | 0.1 °C / 0.1% RH |
| Temp Uniformity | ±2.0 °C |
| Humidity Uniformity | ±3.0% RH |
| Control Accuracy | ±0.5 °C / ±2.5% RH |
| Heating Rate | ~4.0 °C/min |
| Cooling Rate | ~1.0 °C/min |
| Controller | OYO 8226 touchscreen HMI (Japanese-made), bilingual UI (EN/CN), 100 programs × 1000 segments × 999 cycles, max segment duration: 99 h 59 min |
| Communication | RS-232 / RS-485 interface for PC-based test scheduling, real-time monitoring, and remote start/stop |
| Safety Protections | Fuseless circuit breaker, compressor overload protection, refrigerant HP/LP cut-off, over-temp/over-humidity interlock, water shortage alarm, fault diagnostic display |
| Structural Features | A3 carbon steel outer shell (powder-coated), SUS#304 mirror-finish inner chamber, multi-layer tempered observation window with conductive ITO film, Φ50 mm cable port (left side), double-lip high-tensile silicone door seal, counterforce-free door handle, retractable vibration table rail system, low-noise centrifugal blower (single-cycle airflow), epoxy-silicone hybrid sealing between shaker table and chamber base |
| Compliance | Designed per IEC 60068-2 series, MIL-STD-810H environmental test methodology frameworks, supports GLP/GMP audit-ready data logging when integrated with compliant software |
| Key | Brand: OEM/White-Label |
|---|---|
| Origin | Imported (Global Sourcing) |
| Manufacturer Type | Authorized Distributor |
| Price | USD 21,000 (FOB) |
| Temperature Range Options | -20°C to +150°C |
| Humidity Range | 20–98% RH |
| Temp. Uniformity | ≤ ±2.0°C |
| Temp. Stability | ≤ ±0.5°C |
| Humidity Deviation | +2 / −3% RH |
| Heating Rate | −20°C → +100°C in ≈35 min |
| Cooling Rate | +25°C → −40°C in ≈50 min |
| Refrigeration System | Twin-stage or cascade refrigeration with hermetic compressors (e.g., Tecumseh/Tecumseh-derived or equivalent industrial-grade units) |
| Air Circulation | Multi-blade centrifugal blower with optimized ducted airflow for uniform chamber distribution |
| Control Algorithm | PID-based digital controller with auto-tuning and parameter lockout |
| Compliance Standards | GB/T 2423.1–2023, GB/T 2423.2–2023, GB/T 5170.2–2017, GB/T 2424.1–2023, GB 11158–2012, GB 10592–2023 |
| Key | Brand: OEM / Third-Party Manufacturer |
|---|---|
| Origin | Imported |
| Supplier Type | Authorized Distributor |
| Price | USD 21,000 (FOB) |
| Compliance | GB/T 5170.2–1996, GB/T 2423.3–1993, GB/T 2423.1–1989, GB/T 2423.2–1989, GJB 150.3–1986, GJB 150.4–1986 |
| Refrigerant | R134a or R507 (ODP = 0, non-flammable, non-explosive) |
| Humidity Sensor | Capacitive electronic type, ±1.5% RH accuracy |
| Cooling System | Twin-stage or cascade refrigeration circuit with hermetic Tecumseh (France) compressors |
| Airflow | Multi-blade centrifugal blower, uniform velocity distribution, ΔT ≤ ±1.0°C across working volume |
| Control Algorithm | PID auto-tuning with disturbance rejection and setpoint ramping |
| Brand | OEM / Custom-Built |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Price | USD 21,000 (FOB) |
| Internal Liner | Mirror-Finish SUS304 Stainless Steel |
| External Casing | Brushed SUS304 or Galvanized Cold-Rolled Steel |
| Insulation | Glass Wool + Rigid Polyurethane Foam |
| Heating System | Ni-Cr Alloy Heaters |
| Cooling System | Two-Stage Mechanical Refrigeration (Bitzer or Copeland Semi-Hermetic Compressors) |
| Refrigerants | HFC-404A / HFC-23 |
| Condenser | Stainless Steel Brazed Plate Heat Exchanger |
| Evaporator | Finned-Tube Air Cooler |
| Cooling Method | Water-Cooled |
| Humidification | Built-in Reservoir with Precision Submersible Pump |
| Air Circulation | Single-Cycle Forced Convection (Bottom-In/Top-Out), Extended-Shaft Centrifugal Fan with Wide-Band Stainless Blades |
| Control System | Dual-Language (English/Chinese) Color Touchscreen + PLC-Based Controller (OYO or TIME) |
| Vibration Interface | Optional Electrodynamic or Electromechanical Shaker Mounting Kit (User-Specified) |
| Compliance | GB/T 5170.2, GB/T 2423.1–2423.3, GJB 150.3–150.4 |
| Key | Temperature Range: −20 °C to +150 °C / −40 °C to +150 °C / −60 °C to +150 °C |
|---|---|
| Temperature Uniformity | ≤ ±2 °C |
| Temperature Fluctuation | ±0.5 °C |
| Temperature Deviation | ≤ ±2 °C |
| Ramp Rate | 0.7–1.0 °C/min |
| Time Setting Range | 0–9999 h |
| Sinusoidal Force Capacity | 2.94 kN (300 kgf) |
| Frequency Range | 5–500 Hz |
| Max Acceleration | 980 m/s² (100 g) |
| Max Velocity | 1.1 m/s |
| Max Displacement | 25 mm p-p |
| Moving Mass | 2.7 kg |
| Payload Capacity | 120 kg |
| Tabletop Dimensions | 150 mm × 150 mm |
| Vibration Axis | Vertical (Z-axis only) |
| Power Supply | AC 380 V ±10%, 50 Hz, 3-phase 5-wire |
| Cooling Method | Water-cooled |
| Refrigerant | R404A/R23 (HFC-based, non-ozone-depleting) |
| Control System | PLC-based programmable controller with bilingual (English/Chinese) color touchscreen interface (OYO or TIME brand) |
| Tabletop Dimensions | 500 × 500 mm |
|---|---|
| Vibration Axis | Vertical |
| Maximum Payload | 100 kg |
| Frequency Range | 1–600 Hz |
| Sweep Frequency Range | 1–600 Hz |
| Displacement Amplitude | 0–5 mm (peak-to-peak) |
| Maximum Acceleration | 20 g |
| Time Control Resolution | 1 second (up to 1 year duration) |
| Waveforms | Sine, Half-Sine |
| Drive Power | 2.2 kVA |
| Input Voltage | 220 V ±10% AC |
| Maximum Current | 5 A |
| Frequency Resolution | 0.01 Hz (displayed to 0.1 Hz) |
| Shaker Body Dimensions (H×W×D) | 500 × 500 × 160 mm |
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |