| Brand | FTT |
|---|---|
| Origin | United Kingdom |
| Model | FRP |
| Standards Compliance | EN ISO 9239-1, ASTM E648, ASTM E970, NFPA 253, GB/T 11785 |
| Radiation Source | Gas-fired flat-panel radiator inclined at 30° |
| Radiant Heat Flux Range | 1.1–10.9 kW/m² (extendable to 25.0 kW/m²) |
| Critical Radiant Flux Resolution | 0.1 kW/m² |
| Sample Orientation | Horizontal |
| Ignition | Pilot burner with stainless steel nozzle |
| Smoke Measurement | DIN 50055-compliant optical smoke density system mounted on exhaust duct |
| Dimensions (W×D×H) | 1900 × 750 × 1900 mm |
| Construction | Stainless steel hood, calibrated angular positioning plate, dual-access observation door with sliding platform |
| Brand | FTT |
|---|---|
| Origin | United Kingdom |
| Model | iCone |
| Compliance | ISO 5660-1 & -2, ASTM E1354, ASTM E1740, ASTM F1550, ASTM D5485, ASTM D6113, NFPA 271, NFPA 264, CAN/ULC-S135, BS 476-15, GB/T 16172 |
| Heat Flux Range | Up to 100 kW/m² |
| Sample Size | 100 mm × 100 mm (max thickness 50 mm) |
| Mass Loss Resolution | 0.01 g |
| Exhaust Flow Rate | 24 L/s |
| Oxygen Analysis | Paramagnetic or Zirconia-based O₂ sensor |
| Smoke Obscuration | He–Ne laser (0.5 mW), Si photodiode detector with ND filters (0.3 & 0.8) |
| Ignition Source | 10 kV spark igniter with auto-positioning and safety cutoff |
| Data Acquisition | Synchronized multi-channel, 100 Hz sampling rate |
| Software | ConeCalc v6.x (Windows-based, multilingual UI) |
| Brand | FTT |
|---|---|
| Origin | United Kingdom |
| Model | NBS |
| Compliance | ASTM E662, ASTM F814, ISO 5659-2, NFPA 258, BS 6401, GB/T 8323, IMO FTPC Part 2, NES 711 |
| Chamber Dimensions | 914 mm × 914 mm × 610 mm (L×H×W) |
| Radiant Heat Flux Range | 10–50 kW/m² (calibrated at 25 kW/m² ±1 kW/m²) |
| Optical System | 6.5 V Tungsten Lamp + S-4 Spectral Response Photomultiplier Tube (dark current <10⁻⁹ A) |
| Light Beam Transmission Accuracy | 0.01% |
| Optical Density Resolution | 0.01 |
| Mass Loss Measurement Accuracy | ±0.1% |
| Timer Resolution | 0.1 s |
| Cone Heater Power | 2600 W |
| Thermocouples | Dual K-type armored (Cu/Alumel) |
| Heat Flux Meter | Thermopile-based, calibrated to ±1 kW/m² at 25 & 50 kW/m² |
| Ignition | Horizontal single-flame burner (30 mm ±5 mm), spark-ignited without chamber opening |
| Brand | FTT |
|---|---|
| Origin | United Kingdom |
| Model | Oxygen Bomb Calorimeter |
| Standards Compliance | ISO 1716, ISO 1928, ASTM D240, ASTM D4809, ASTM D5468, ASTM D5865, ASTM E711 |
| Application Scope | Gross Calorific Value (GCV) determination of solid, liquid, and heterogeneous fuels and combustible materials |
| Configuration | Includes main calorimeter unit, high-pressure oxygen bomb assembly, oxygen charging station, calibration accessories (benzoic acid standard, ignition wire, crucibles), and installation kit |
| Brand | Guance |
|---|---|
| Origin | Beijing, China |
| Model | GCYZS-75A |
| Measurement Range | 0–100% O₂ |
| Resolution | 0.1% O₂ |
| Accuracy | ±0.4% O₂ |
| Response Time | <10 s |
| Display Precision | 0.1% ±1 digit |
| Drift | <3% per year |
| Combustion Tube ID | 90 mm, Length: 480 mm |
| Gas Flow Velocity in Tube | 40 ±10 mm/s |
| Chamber Temperature Control | 23 ±2 °C |
| Ignition Flame Length | 5–50 mm (adjustable) |
| Power Supply | 220 V ±15%, 50 Hz, 100 W |
| Operating Pressure | 0.1 MPa |
| Input Pressure Range | 0.25–0.4 MPa |
| Gas Requirements | Industrial-grade O₂ (GB/T 3863) and N₂ (GB/T 3864), each with pressure regulator (user-supplied) |
| Brand | Aerospace Vertical |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | HAG-Type |
| Price Range | USD 6,000 – 10,000 (FOB) |
| Application | Halogen acid gas quantification in flame-retardant cables |
| Sample Form | Solid wire & cable specimens |
| pH Repeatability | ±0.02 pH units |
| Combustion Boat | Fused quartz tube, 100 mm × 25 mm × 10 mm (L × W × D) |
| Air Filtration | Activated carbon + silica gel dual-stage drying & purification |
| Thermocouple | K-type, 0–1300 °C, stainless-steel sheathed |
| Heating Furnace | 600 mm effective length × Ø42 mm ID, 10 kW electric heating, PID-controlled |
| Gas Collection | Dual 500 mL absorption flasks |
| Air Flow Control | 20–200 mL/min adjustable rotameter |
| Power Supply | 220 V AC, 30 A |
| Conductivity Range | 0–1×10⁵ µS/cm |
| pH Measurement Range | 0–14, resolution 0.01 pH |
| Origin | Japan |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | HFM-201 |
| Pricing | Upon Request |
| Brand | Insment |
|---|---|
| Model | KS-118D |
| Origin | Shanghai, China |
| Radiation Source Power | 500 W |
| Radiation Surface Diameter | Φ100 mm ± 5 mm |
| Sample Holder Inner Diameter | 118 mm (stainless steel ring) |
| Stainless Steel Mesh | Wire diameter 0.70 mm, aperture 2.10 mm |
| Sample Dimensions | 70 mm × 70 mm, max thickness 13 mm |
| Drip Catcher Diameter | Φ118 mm, depth 12 mm |
| Distance from Sample Upper Surface to Radiant Source | 30 mm |
| Distance from Sample Holder to Drip Catcher (cotton pad) | 300 mm |
| Heat Flux Meter Range | 10 W/cm² |
| Overall Dimensions | 1120 mm (W) × 580 mm (D) × 1350 mm (H) |
| Exhaust Port Diameter | Φ100 mm |
| Power Supply | AC 220 V, 50 Hz, ≤1000 W |
| Compliance | UN ECE Regulation No. 118, Annex 7 |
| Origin | Tianjin, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | ISO 9150 |
| Pricing | Available Upon Request |
| Origin | Germany |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | ISO 9151 |
| Pricing | Available Upon Request |
| Brand | Jiubin Instruments |
|---|---|
| Model | JB-319B |
| Origin | Shanghai, China |
| Applicable Standard | GB/T 8333–2008 |
| Burner Inner Diameter | Φ9.5 ± 0.5 mm |
| Burner Length | 102 mm |
| Adjustable Flame Height | 20–175 mm |
| Maximum Flame Temperature | 1100 °C (Bunsen burner flame at 960 °C ± 20 °C) |
| Timing Range | 0–99 min 99 sec (flame application & afterflame duration) |
| Gas Supply | Liquefied Petroleum Gas (LPG) or Town Gas |
| Air Adjustment Port | Integrated |
| Compliance | GB/T 8333–2008 (equivalent to ISO 5657:1997 for vertical flame propagation on rigid cellular plastics) |
| Warranty | 12-month parts and labor coverage |
| Brand | Jianhu |
|---|---|
| Origin | Shanghai, China |
| Model | H-8925 (8820G) |
| Combustion Time Range | 0–99.99 s/min/h |
| Burner Nozzle Inner Diameter | 9.5 mm |
| Nozzle Center Position | 19 mm below free end center of specimen |
| Metal Hood Dimensions | 385 × 204 × 360 mm |
| Control Box Dimensions | 305 × 320 × 285 mm |
| Comb Comb Length | ≥110 mm |
| Steel Ruler Accuracy | ±1 mm |
| Fuel | Liquefied Petroleum Gas (LPG), user-supplied |
| Power Supply | 220 V AC, 50 Hz |
| Compliant Standards | GB 8410–2006, TL 1010, GM 6090M, DIN 75200, GM 9070P |
| Brand | KARG |
|---|---|
| Origin | Germany |
| Model | UL94 |
| Chamber Material | Polished Stainless Steel |
| Burner Adjustment | Horizontal travel 240 mm, angular tilt 0°/20°/45° |
| Specimen Holder Travel | Horizontal 840 mm, Vertical 730 mm |
| Specimen Holders | 5 types for multi-standard compliance |
| Timer Range | 0–100 s in 1-s increments |
| Airflow Control | Integrated mass-flow regulated exhaust system |
| Exhaust Fan | Variable-speed centrifugal fan |
| External Dimensions (W×H×D) | 1500 × 1500 × 600 mm |
| Net Weight | 200 kg |
| Applicable Standards | UL 94, ASTM D635, ASTM D3801, ASTM D4804, ASTM D5048, ASTM D4986, IEC 60695-11-10 (replaces ISO 1210), IEC 60695-11-20 (replaces ISO 10351), ISO 9772, ISO 9773 |
| Brand | Loobo |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | LB-FHB08 |
| Price | USD 495 (FOB Qingdao) |
| Compliance | MEP “Guidelines for Standardization of Comprehensive Ecological and Environmental Protection Law Enforcement Equipment (Standard Configuration, 2020 Edition)” |
| Construction | Anodized aluminum frame chassis |
| Configuration Flexibility | Modular slot-based layout for field-customizable PPE integration |
| Transport Form Factor | Dual-option — rugged wheeled trolley case or ergonomic dual-shoulder backpack |
| Brand | MOTIS |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | GCF |
| Pricing | Available Upon Request |
| Temperature Control | Programmable controller with standard temperature ramp profile (e.g., BS 8414 Annex A) |
| Test Duration | Up to 24 h continuous monitoring and control |
| Compliance | BS 8414-1:2015, BS 8414-2:2015 (aligned with draft GB/T 39173 under development) |
| Data Acquisition | Real-time display of furnace interior and specimen surface temperatures |
| Thermocouple Configuration | Integrated internal furnace thermocouples + dedicated specimen surface thermocouples |
| Specimen Handling | Freely accessible test chamber with standardized mounting interface for façade system assemblies |
| Brand | MOTIS |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | HTI |
| Pricing | Available Upon Request |
| Standard Compliance | EN 367, ISO 9151, AQ 6103–2007 |
| Heat Flux | 80 kW/m² |
| Thermocouple Type | Copper Disc Calorimeter (ISO 9151-compliant) |
| Temperature Rise Thresholds | 12 °C and 24 °C above baseline (25 °C) |
| Cooling | Forced-air cooling for calorimeter |
| Control | Pneumatic actuation + PC-based software automation |
| Power Supply | 220 V, 50 Hz |
| Gas Supply | Propane + compressed air |
| Dimensions (W×H×D) | 500 × 500 × 500 mm |
| Ambient Test Environment | 25 ± 5 °C |
| Brand | MOTIS |
|---|---|
| Origin | Shanghai, China |
| Model | PFET |
| Compliance | IMO A.753, ISO 19921–1 & 19921–2, ISO 10497, FTP Code Annex 2 (Res. A.753) |
| Test Pressure Range | 0–20 bar |
| Thermal Radiation Sensor | Calibrated heat flux meter (kW/m²) |
| Cooling System | Integrated water-cooled calorimeter mount |
| Temperature Monitoring | Dual K-type thermocouples (0–1200 °C) |
| Sample Positioning | Motorized X-Y-Z adjustable test platform |
| Data Acquisition | PC-based real-time logging software with time-synchronized thermal, pressure, and radiation curves |
| Brand | MOTIS |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | SBI |
| Pricing | Available Upon Request |
| Compliance | EN 13823, GB/T 20284 |
| Core Measurement Principle | Oxygen Consumption Calorimetry & Optical Smoke Density Analysis |
| Key Outputs | FIGRA, THR, SMOGRA, TSP, LFS, Droplet Observation |
| Brand | MOTIS |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | SBI |
| Pricing | Available Upon Request |
| Standards Compliance | EN 13823, GB/T 20284 |
| Core Measurement Principles | Oxygen depletion calorimetry, optical smoke density analysis, flame spread observation, droplet collection |
| Key Outputs | FIGRA, THR, SMOGRA, TSP, LFS, flaming droplets/particles |
| Brand | MOTIS |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | SBI |
| Pricing | Upon Request |
| Standards Compliance | EN 13823, GB/T 20284 |
| Measurement Principles | Oxygen depletion calorimetry, optical smoke density analysis, flame spread observation, droplet collection |
| Key Outputs | FIGRA, THR, SMOGRA, TSP, LFS, flaming droplets/particles |
| Brand | MOTIS |
|---|---|
| Model | SDB |
| Origin | Shanghai, China |
| Chamber Internal Dimensions | 914 × 914 × 610 mm |
| Optical Detection System | Side-window Photomultiplier Tube (PMT), S-4 spectral response, transmittance resolution ≤ 0.0001% |
| Radiation Sources | ASTM E662 Radiant Panel (25 kW/m²) and ISO 5659-2 Radiant Cone (50 kW/m²) |
| Ignition Sources | ASTM E662 Flame Burner, ISO 5659-2 Flame Burner, NES 711 Flame Burner with Mixing Fan |
| Temperature Control | External Auxiliary Heating Jacket |
| Pressure Regulation | Automatic Pressure Relief Valve with Calibrated Volume Bottle |
| Safety Features | Explosion-Proof Aluminum Foil Liner, Top/Bot Pneumatic Cylinders, Full-Access Front Door |
| Cooling Options | Air-Cooled Copper Heat Flux Meter, Water-Cooled MEDTHERM Heat Flux Meter (NIST-traceable), Self-contained Recirculating Chiller |
| Mass Loss Measurement | Integrated Balance (0–5000 g, ±0.01 g) |
| Compliance Standards | ASTM E662, ISO 5659-2, NES 711, GB/T 8323 |
| Software | Integrated Touchscreen PC with Real-time Transmittance Logging, Report Generation, and Calibration Workflow |
| Optional Add-ons | Dräger Gas Detection Tubes, FTIR Coupling Interface for Smoke Toxicity & Speciation Analysis |
| Brand | Netzsch |
|---|---|
| Origin | Germany |
| Model | FRG Structural Adhesion Tester |
| Compliance | DIN EN 520 |
| Sample Dimensions (L × W × T) | 300 × 45 × 9.5 / 12.5 / 15.0 mm |
| Propane Purity | ≥95%, Operating Pressure: 4.0 bar |
| Device Dimensions (W × D × H) | 450 × 400 × 300 mm |
| Weight | 37 kg |
| Brand | Netzsch |
|---|---|
| Origin | Germany |
| Model | HBK Horizontal Burning Chamber |
| Compliance Standards | ISO 3795, DIN 75200, FMVSS 302, GB 8410, CMVSS 302, FAR 25.853 |
| Sample Dimensions | 356 × 100 × ≤13 mm |
| Fuel | ≥95% purity propane |
| Gas Pressure | 4.0 bar |
| Chamber Dimensions (W×D×H) | 385 × 210 × 365 mm |
| Weight | 26 kg |
| Brand | Netzsch |
|---|---|
| Origin | Germany |
| Model | KBK Flammability Test Chamber |
| Compliance | EN ISO 11925-2 |
| Sample Dimensions | 250 × 90 × ≤60 mm |
| Fuel | Propane (≥95% purity) |
| Gas Pressure | 4.0 bar |
| Airflow Velocity Accuracy | ±0.1 m/s |
| Operating Temperature | +23 ± 5 °C |
| Chamber Dimensions (W×D×H) | 700 × 400 × 980 mm |
| Construction Material | Corrosion-Resistant Stainless Steel |
| Viewing Windows | Dual Large-Sized Fire-Rated Glass Doors |
| Adjustable Sample Holder | Horizontal & Vertical Positioning |
| Brand | Netzsch |
|---|---|
| Origin | Germany |
| Model | KBT Cable Fire Testing System |
| Standards Compliance | EN 50399, IEC 60332-3, GB/T 31248, GB/T 18380.31, IEC 60332-3-10 |
| Chamber Dimensions (W × D × H) | 135 × 235 × 430 cm |
| Exhaust Opening (W × D) | 100 × 30 cm |
| Fume Hood Dimensions (H × W × D) | 100 × 150 × 100 cm |
| Temperature Measurement Range | −100 to 1300 °C, Resolution: 0.1 K |
| Mass Flow Controller Range | 0–1 L/min, Accuracy: ±0.3 L/min |
| Paramagnetic O₂ Analyzer | 16–21 % (v/v), Max. Resolution: 0.001 % |
| NDIR CO₂ Analyzer | 0–10 % (v/v) |
| Peltier Condenser | Min. Temp. −10 °C, Dryer-Free Operation |
| Gas Sampling Probes | High-Precision Bidirectional |
| Control System | Siemens Gas Analyzers with Auto-Calibration & Dual-Direction Data Exchange |
| Brand | NETZSCH |
|---|---|
| Origin | Germany |
| Model | LOI Oxygen Index Analyzer |
| Compliance | ISO 4589-2, DIN 22117, ASTM D2863 |
| Dimensions (W × D × H) | 360 × 360 × 630 mm |
| Glass Column Dimensions (Ø × H) | 75 × 450 mm |
| Test Accuracy | ±0.1% O₂ |
| Weight | 8.2 kg |
| Oxygen Sensor Type | Paramagnetic |
| Display | Color High-Resolution Touchscreen |
| Sample Holders | Supported & Unsupported Configurations |
| Data Interface | USB & Ethernet |
| Automation | Fully Automated Calibration & Test Sequence |
| Brand | NETZSCH |
|---|---|
| Origin | Germany |
| Model | SBI Single Burning Item Test System |
| Compliance | EN 13823, GB/T 20284, GB/T 20248 |
| Sample Configuration | Two perpendicular non-flooring building material specimens mounted on a trolley |
| Ignition Source | Sand-boxed J-type burner |
| Exhaust Duct | Ø(315 ± 5) mm |
| Mass Flow Controller Range | >0–2.1 g/s, accuracy better than ±1.5% of reading |
| Burner Switching Response Time | ≤12 s |
| Oxygen Analyzer | Paramagnetic, 16–21% (v/v), resolution 0.001% |
| CO₂ Analyzer | NDIR, 0–10% (v/v) |
| Smoke Measurement | White-light or laser-based optical density system |
| Cooling | Peltier-cooled gas conditioning unit |
| Data Acquisition | Integrated modular control and acquisition platform |
| Interface | High-resolution color touchscreen HMI |
| Gas Analysis | Siemens OEM analyzer with bidirectional communication and auto-calibration capability |
| Brand | Netzsch |
|---|---|
| Origin | Germany |
| Model | SBK Flammability Test Chamber for Toys |
| Compliance | EN 71-2 |
| Sample Dimensions (H × W) | 610 (310) × 100 mm |
| Sample Holder | Adjustable in Horizontal and Vertical Planes |
| Fuel | Propane (≥95% purity) |
| Gas Pressure | 4.0 bar |
| Operating Temperature | +23 ± 5 °C |
| Chamber Dimensions (W × D × H) | 70 × 70 × 121 cm |
| Construction | Corrosion-Resistant Stainless Steel |
| Viewing | Dual Large Fire-Rated Glass Doors |
| Gas Control | Front-Mounted Main Shut-Off Valve and Fine-Tuning Burner Control Valve |
| Pressure Monitoring | Integrated Pressure Gauge Regulator |
| Burner Positioning | Contaminant-Shielded Burner Displacement Mechanism |
| Application Scope | Textiles, Furnishings, Toy Accessories (e.g., Wigs, Facial Hair Simulants, Plush Trim) |
| Brand | Netzsch |
|---|---|
| Origin | Germany |
| Model | TBB Radiant Panel Test Apparatus |
| Standard Compliance | EN ISO 9239-1 |
| Chamber Dimensions (H×W×D) | 212 × 53 × 142 cm |
| Specimen Dimensions (H×W×D) | 2.2 × 32.5 × 114 cm |
| Radiant Heat Source Temperature Range | 300–1000 °C |
| Temperature Resolution | 0.1 K |
| Heat Flux Measurement Range (Schmidt-Boelte Type) | 0–20 kW/m² |
| Light Source | 10 W Halogen Spot Lamp, Color Temperature 2900 K |
| Brand | Netzsch |
|---|---|
| Origin | Germany |
| Model | TCC918 Cone Calorimeter |
| Cone Heater | 220 V, 5 kW, adjustable heat flux 0–100 kW/m² |
| Thermocouple Accuracy | ±0.5 °C, tolerance 0.004 |
| Specimen Holder | 100 × 100 × 50 mm (expandable for vertical drip testing) |
| Load Cell | 8.2 kg max capacity, resolution 0.01 g, linearity ±0.02 g |
| Heat Flux Meter | fully automated control, accuracy ±2%, repeatability ±0.5% |
| O₂ Analyzer | paramagnetic, 0–25% vol, accuracy 0.001%, noise & drift <100 ppm |
| CO₂ Analyzer | NDIR, 0–10% vol, accuracy 0.001% |
| CO Analyzer | NDIR, 0–1% vol, accuracy 0.001% |
| C-factor Range | 0.036–0.044, calibration deviation ≤5% |
| Peltier Cooling | down to −10 °C |