Concentrators
Filter
Showing 1–30 of 42 results
| Brand | Amerlab |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | AE100 |
| Instrument Type | Automated Quantitative Concentrator |
| Temperature Range | Ambient to 250 °C |
| Temperature Control Accuracy | ±1 °C |
| Maximum Sample Capacity per Vial | 100 mL |
| Brand | ANAYN |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | CYNS-16K |
| Instrument Type | Vacuum Parallel Evaporator |
| Temperature Range | Ambient to 100 °C |
| Temperature Control Accuracy | ±1 °C |
| Throughput | 16 × 150–200 mL samples |
| Vacuum Pump Flow Rate | 20–30 L/min |
| Ultimate Vacuum | ≤8 mbar |
| Condensation System | Dual-tower cold trap with recirculating chiller |
| Display | 7-inch capacitive touchscreen interface |
| Sealing Interface | PFA-coated lid with threaded glass tube coupling |
| Chamber Volume | ≥8 L, triple-transparent viewing window |
| Safety Features | Low-water-level alarm, solvent recovery buffer bottle, PTFE diaphragm vacuum pump, PEEK/PTFE/glass fluid path |
| Compliance | Designed for GLP-compliant workflows |
| Brand | Annuo |
|---|---|
| Origin | Henan, China |
| Model | SC-4223 |
| Instrument Type | Automated Quantitative Gas Preconcentrator |
| Cold Trap Temperature Range | −30 °C to 300 °C (at 25 °C ambient) |
| Valve & Transfer Line Temperature Range | Ambient to 160 °C |
| Cooling Method | Peltier Thermoelectric |
| Sample Volume | 1–2000 mL |
| Maximum Concentration Ratio | 2000:1 |
| Precision | RSD ≤ 3% |
| Power Supply | AC 220 V, 50 Hz |
| Dimensions | 550 × 260 × 427 mm |
| Weight | ~20 kg |
| Interface Options | RS-232, Ethernet |
| GC Trigger Modes | Time-based or GC reverse control |
| Analysis Time Range | 0.1–999 min |
| Max Power Consumption | 1000 W |
| Brand | Annuo |
|---|---|
| Origin | Henan, China |
| Model | SC-4224 |
| Instrument Type | Automated Quantitative Gas Preconcentrator |
| Temperature Range (Valve & Tubing) | +5°C to 160°C |
| Cold Trap Temperature Range | −50°C to 300°C |
| Sample Volume Capacity | 1–2000 mL |
| Concentration Ratio | Up to 2000:1 |
| Temperature Control Accuracy | RSD ≤3% |
| Reproducibility | RSD ≤3% |
| Sample Introduction | Vacuum Pressure Sampling with MFC Flow Control |
| Cooling Method | Compressor-based |
| Dimensions (W×D×H) | 550 × 260 × 427 mm |
| Power Supply | AC 220 V, 50 Hz |
| Max Power Consumption | 1000 W |
| Weight | ~40 kg |
| Compliance | GB/T 14678–1993 |
| Brand | ANYAN (Hangzhou Anyan Instrument Co., Ltd.) |
|---|---|
| Origin | Zhejiang, China |
| Model | AYAN-25K |
| Instrument Type | Vacuum Parallel Concentrator |
| Temperature Range | Ambient to 100 °C |
| Temperature Control Accuracy | ±1 °C |
| Oscillation Speed | 0–300 rpm |
| Sample Capacity | 25 positions (150–200 mL vials) |
| Timer Range | 0–999 min |
| Heating Method | Water Bath |
| Included Systems | Integrated Vacuum Pump, Dual-Tower Condensation Module, Closed-Loop Water Circulation Chiller |
| Brand | Anyan Instrument |
|---|---|
| Origin | Zhejiang, China |
| Model | CHNS-25K |
| Instrument Type | Vacuum Parallel Concentrator |
| Temperature Range | Ambient to 100 °C |
| Temperature Control Accuracy | ±0.5 °C |
| Sample Capacity | 25 × 150–200 mL |
| Timing Range | 0–999 min |
| Heating Method | Circulating Water Bath |
| Condensation System | Dual-Tower Cold Trap with External Recirculating Chiller Support |
| Sealing Architecture | Individual Sample-Specific Vacuum Seals |
| Compliance | Designed for GLP-aligned workflows |
| Brand | Anyanyiqi |
|---|---|
| Origin | Zhejiang, China |
| Model | CHNS-16K |
| Instrument Type | Vacuum Parallel Concentrator |
| Temperature Range | Ambient to 100 °C |
| Temperature Control Accuracy | ±1 °C |
| Sample Capacity per Vial | 150 mL or 200 mL |
| Throughput | 1–16 samples simultaneously |
| Timer Range | 0–999 min |
| Heating Method | Water Bath |
| Brand | ATR |
|---|---|
| Origin | USA |
| Model | AutoVap S8 |
| Instrument Type | Automated Quantitative Concentrator |
| Temperature Range | Ambient to 99°C |
| Temperature Control Accuracy | ±0.5°C |
| Sample Volume Capacity | 0–50 mL (standard), optional 0–200 mL |
| Endpoint Detection | 0.5 mL or 1.0 mL optical sensing |
| Parallel Channels | 8 independent channels |
| Concentration Speed | 3–5× faster than conventional nitrogen blow-down systems |
| Sample Recovery Rate | ≥90% (typical, matrix-dependent) |
| Endpoint Precision | <5% volume error |
| Brand | ATR |
|---|---|
| Origin | USA |
| Model | S60 |
| Instrument Type | Automatic Quantitative Concentrator |
| Temperature Range | Ambient to 99°C |
| Temperature Control Accuracy | ±0.5°C |
| Sample Volume Capacity | 0–60 mL |
| Heating Method | Water Bath (Manufactured in Singapore) |
| Power Rating | 800 W |
| Gas Flow Rate | 0–8 L/min |
| Compatible Tube Sizes | 1.5 mL to 50 mL |
| Application Fields | Environmental (EPA), Pharmaceutical (FDA, USP), Clinical (CDC), Food Safety, Academic Research, and Chemical Analysis |
| Brand | Ji Aim |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | Auto C1 |
| Price Range | USD 28,000 – 56,000 |
| Instrument Type | Vacuum Centrifugal Concentrator |
| Temperature Range | Ambient to 70°C |
| Temperature Control Accuracy | ±2°C |
| Rotational Speed | 1500 rpm |
| Vacuum Display Range | 0.1–99.9 mbar |
| Vacuum Control | Yes |
| Heating Power | 1500 W |
| Power Supply | AC 220 V, 50/60 Hz, 10 A |
| Dimensions (W×D×H) | 657 × 518 × 465 mm |
| Lid Opening Mechanism | Vertical Lift |
| Positioning Accuracy | <1 mm |
| Rotor Configuration | Horizontal Dual-Plate Carrier (2 × 96-well Deep-Well Plates or Sample Vial Baskets) |
| Corrosion Resistance | Solvent-Compatible Materials (e.g., PTFE-coated Seals, 316 Stainless Steel Components) |
| Brand | BIOCOOL |
|---|---|
| Origin | Tianjin, China |
| Model | FastDry-1 |
| Instrument Type | Vacuum Centrifugal Concentrator |
| Temperature Range | Ambient to –80 °C |
| Temperature Control | Gradient PID Control |
| Sample Capacity | 132 × 1.5 mL tubes |
| Vacuum Pump Options | Diaphragm or Direct-Coupled Rotary Vane Pump |
| Ultimate Vacuum | <10 Pa |
| Rotational Speed | 400–1800 rpm (variable frequency drive) |
| Chamber & Rotor Coating | PTFE (Teflon®) |
| Control Interface | 7-inch Industrial Touchscreen + PLC |
| Safety Features | Vacuum-delayed spin initiation, Auto Venting, Overheat/Overpressure/Imbalance Protection |
| Compliance | Designed for GLP/GMP-aligned workflows |
| Brand | Biotage |
|---|---|
| Origin | Sweden |
| Model | Isolera Prime |
| Instrument Type | Automated Flash Chromatography System |
| Flow Rate | 1–100 mL/min |
| Maximum System Pressure | 10 bar (150 psi) |
| UV Detection Range | 200–400 nm (standard), optional 200–800 nm |
| Gradient Capability | Dual-solvent channels with TLC-driven gradient generation |
| Fraction Collection Options | 13 mm, 16 mm, 18 mm, 25 mm test tubes |
| Display | 10.4-inch capacitive touchscreen |
| Operating System | Embedded Linux |
| Connectivity | Ethernet-enabled for remote control, data logging, and network printing |
| Compliance | Compatible with GLP/GMP workflows via audit trail-ready software architecture |
| Brand | Biotage |
|---|---|
| Origin | USA |
| Model | V-10 Touch |
| Instrument Type | Vacuum Centrifugal Concentrator |
| Temperature Range | Ambient to 99 °C |
| Temperature Control Accuracy | ±0.1 °C |
| Sample Capacity | 0–1000 mL |
| Built-in Vacuum Pump | 2 mbar ultimate pressure |
| Maximum Rotor Speed | 8000 rpm |
| Brand | Detelogy |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Vacuum Parallel Concentrator |
| Model | MultiPro-V20 |
| Temperature Range | 0–100 °C |
| Temperature Control Accuracy | ±0.1 °C |
| Sample Capacity per Vial | 50–250 mL |
| Throughput | 20 Samples Simultaneously |
| Display | 10.1″ Capacitive Touchscreen |
| Vacuum System | Corrosion-Resistant Diaphragm Pump |
| Cooling | Dual Optional Condenser Tower |
| Automation | Auto Fill/Drain, Gradient Vacuum Control (20 Steps), Method Storage (32 Protocols) |
| Data Management | Audit Trail, USB Export, Remote Monitoring via DTLabs App |
| Brand | EURO TECH |
|---|---|
| Origin | Shanghai, China |
| Model | ET3301A |
| Instrument Type | Purge-and-Trap Nitrogen Evaporator |
| Temperature Range | Ambient to 95 °C |
| Temperature Control Accuracy | ±1 °C |
| Maximum Sample Capacity | 60 samples |
| Gas Inlet Pressure | 60–100 psi |
| Maximum Gas Flow per Nozzle | 2 L/min |
| Timer Range | 1–999 min |
| Power Supply | 230 V, 50 Hz (optional 110 V, 60 Hz) |
| Dimensions (W×H×D) | 54 × 31 × 35 cm |
| Net Weight | 25 kg |
| Shipping Weight | 35 kg |
| Brand | EURO TECH |
|---|---|
| Origin | Shanghai, China |
| Model | ET3302B |
| Sample Capacity | 6 × 50 mL or 6 × 200 mL |
| Temperature Range | Ambient to 95 °C |
| Temperature Control Accuracy | ±1 °C |
| Gas Flow Control Range | 4–25 psi |
| Endpoint Detection Options | 0.5 mL or 1.0 mL (optical sensor) |
| Operating Modes | Auto-Endpoint, Manual, Timer, Auto-Endpoint + Timer |
| Water Bath Temp Range | Ambient to 60 °C |
| Power Supply | 220 VAC, 50 Hz |
| Dimensions (W×D×H) | 54 × 31 × 35 cm |
| Net Weight | 25 kg |
| Exhaust Port | 5 cm ID × 3 m exhaust hose included |
| Gas Inlet | 8 mm OD tubing |
| Recommended Gas Supply Pressure | ≥40 psi (regulated), max 100 psi |
| Typical Evaporation Rate | 2–8 mL/min (dependent on bath temp & gas flow) |
| Brand | EYELA (Tokyo Rikakikai Co., Ltd.) |
|---|---|
| Origin | Japan |
| Model | TVE-1100A / TVE-1100B |
| Concentration Principle | Vortex-assisted vacuum evaporation |
| Temperature Range | Ambient +5°C to 60°C (TVE-1100A), Ambient +5°C to 40°C (TVE-1100B) |
| Temperature Accuracy | ±0.2°C |
| Oscillation Speed | 100–1100 rpm (50/60 Hz) |
| Oscillation Amplitude | 3 mm |
| Gas Line Materials | PTFE, Polypropylene (PP), Viton®, Silicone Rubber, Borosilicate Glass |
| Vacuum & Vent Port OD | 10 mm |
| Drain Tube OD | 12 mm |
| Compatible Vessels | Centrifuge tubes (29 mm OD × 110 mm), Standard test tubes (Φ12–Φ18 mm × 100–180 mm), Straight-, flip-, screw-, and standard ground-glass joint formats |
| Operating Ambient | 5–35°C |
| Dimensions (W×D×H) | 300 × 500 × 670 mm |
| Brand | EYELA (Tokyo Rikakikai Co., Ltd.) |
|---|---|
| Origin | Japan |
| Model | VTX-2000 / VTX-2500 |
| Instrument Type | Automated Quantitative Vacuum Concentrator |
| Temperature Range | +10–80°C |
| Temperature Control Accuracy | ±1°C |
| Sample Capacity | 250 mL × 6 positions |
| Rotational Speed | 20–350 rpm |
| Ultimate Vacuum | 7 hPa (5 mmHg) |
| Cooling Water & Vacuum Port ID | 10 mm |
| Dimensions (W×D×H) | 670 × 570 × 710 mm |
| Weight | 35 kg |
| Brand | KEZHE SHANGHAI |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Vacuum Centrifugal Concentrator |
| Temperature Range | 25–80 °C |
| Temperature Control Accuracy | ±1 °C |
| Sample Capacity per Tube | 3 mL (tail tube volume) |
| Final Absolute Vacuum | 30 mbar |
| Vacuum Pump Flow Rate | 30 L/min |
| Cooling Circulator Temp Range | 10 °C to Ambient |
| Heating Platform Max Temp | 100 °C |
| Rotational Speed | 0–250 rpm |
| Power Supply | 220–240 V, 50/60 Hz |
| Max Power Consumption | 2200 W |
| Brand | KEZHE SHANGHAI |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Category | Vacuum Centrifugal Concentrator |
| Temperature Range | 10–40 °C |
| Temperature Control Accuracy | ±0.5 °C |
| Maximum Sample Volume per Position | 120 mL |
| Sample Capacity | 1–6 parallel positions |
| Final Absolute Vacuum | 8 mbar |
| Cooling Circulator Range | −10 to +25 °C |
| Vacuum Pump Flow Rate | 3 L/min at 0.6 bar |
| Vacuum Pump Speed Control | Yes |
| Rotational Agitation | 0–600 rpm |
| Tail Tube Volumes Supported | 0.3, 1, or 3 mL |
| Brand | KEZHE SHANGHAI |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Model | VNH-1200 |
| Instrument Category | Automated Quantitative Concentrator |
| Temperature Range | Ambient to 150 °C |
| Sample Capacity | 5–120 mL per tube (12-position) |
| Final Absolute Vacuum | 8 mbar |
| Vacuum Pump Flow Rate | 1.8 m³/h |
| Condenser Cooling Range | −10 °C to +25 °C |
| Programmable Temperature Profile | 9-step gradient (0–10 h per step) |
| Vortex Agitation Speed | 0–600 rpm |
| Tail-Tube Volumes | 0.3 mL / 1 mL / 3 mL |
| Control Interface | Touchscreen LCD |
| Power Supply | 220–240 V, 50/60 Hz, Max 1500 W |
| Brand | KEZHE SHANGHAI |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Vacuum Centrifugal Concentrator |
| Temperature Range | Ambient to 100 °C |
| Temperature Control Accuracy | ±1 °C |
| Sample Capacity | 1–6 / 12 (standard), up to 48 (customizable) |
| Final Absolute Vacuum | 30 mbar |
| Solvent Recovery | Integrated Condensation System |
| Vacuum Pump Flow Rate | 30 L/min |
| Cooling Circulator Range | 10 °C to Ambient |
| Programmable Temperature Profile | 6-step, 0–10 h per step |
| Vortex Agitation Speed | 0–250 rpm |
| Tail-tube Volumes | 0.3 / 1 / 3 mL |
| Heating Method | Selectable Metal Bath or Water Bath |
| Power Supply | 220–240 V, 50/60 Hz, Max 2200 W |
| Control Interface | PC-based Software with Audit Trail |
| Brand | KEZHE SHANGHAI |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Vacuum Centrifugal Concentrator |
| Temperature Range | Ambient to 100 °C |
| Temperature Control Accuracy | ±1 °C |
| Sample Capacity | 1–48 positions (standard: 24) |
| Final Absolute Vacuum | 30 mbar |
| Condensate Recovery | Integrated |
| Heating Options | Metal Bath or Water Bath (selectable) |
| Programmable Stages | 6-step gradient temperature control (0–10 h per stage) |
| Rotational Speed | 0–250 rpm |
| Solvent Recovery Efficiency | >95% |
| Cooling Circulator Compatibility | 10 °C to ambient |
| Vacuum Pump Flow Rate | 30 L/min |
| Power Supply | 220–240 V, 50/60 Hz |
| Max Power Consumption | 2200 W |
| Brand | KEZHE SHANGHAI |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Vacuum Centrifugal Concentrator |
| Temperature Range | Ambient to 100 °C |
| Temperature Control Accuracy | ±1 °C |
| Sample Capacity | 1–48 positions (6/12 standard, 24/48 optional) |
| Vacuum Range | 30 mbar to atmospheric pressure |
| Vortex Speed | 0–250 rpm |
| Cold Trap Condensation | Integrated |
| Solvent Recovery | Yes |
| Heating Options | Metal Bath or Water Bath (selectable) |
| Final Volume Precision | 0.3 / 1 / 3 mL tail-tube options |
| Power Supply | 220–240 V, 50/60 Hz, max 2200 W |
| Brand | KEZHE SHANGHAI |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Vacuum Centrifugal Concentrator |
| Temperature Range | Ambient to 80 °C |
| Temperature Control Accuracy | ±0.5 °C |
| Sample Capacity Options | 80 mL, 100 mL, 120 mL, or 500 mL (120 mL standard) |
| Throughput | 16 or 36 samples (configurable) |
| Heating Platform Range | Ambient to 90 °C |
| Vacuum Range | 20 mbar to atmospheric pressure |
| Vortex Shaking Speed | 0–300 rpm |
| Programmable Temperature Profiles | Up to 9-step gradient control |
| Timer Range | 0–10 hours |
| Vacuum Pump Flow Rate | 30 L/min |
| Power Supply | 220–240 V, 50/60 Hz |
| Max. Power Consumption | 2200 W |
| Control Interface | Touchscreen LCD |
| Brand | KEZHE SHANGHAI |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Region Classification | Domestic (China) |
| Model | VNH-300 |
| Instrument Type | Automated Quantitative Concentrator |
| Temperature Range | Ambient to 80 °C |
| Temperature Control Accuracy | ±0.5 °C |
| Sample Capacity per Channel | 250 mL |
| Final Volume Setpoint Range | 0–1 mL |
| Heating Method | Dry Block Heating |
| Number of Channels | 6 |
| Maximum Gas Flow per Channel | 10 L/min |
| Control Interface | Touchscreen HMI |
| Brand | KEZHE SHANGHAI |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | VNH-500 |
| Instrument Type | Automated Quantitative Concentrator |
| Temperature Range | Ambient to 100 °C |
| Temperature Control Accuracy | ≤ 0.5 °C |
| Sample Capacity per Vial | 10–80 mL |
| Maximum Simultaneous Samples | 72 (customizable) |
| Gas Flow Rate | Up to 15 L/min (N₂ or inert gas) |
| Heating Method | Water Bath |
| Operating Modes | Manual / Method-Based / Timer-Based |
| Brand | KEZHE SHANGHAI |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | VNH-600 |
| Instrument Type | Automated Quantitative Concentrator |
| Temperature Range | Ambient to 80 °C |
| Temperature Control Accuracy | ±0.5 °C |
| Sample Vessel Capacity Options | 80 mL, 100 mL, 120 mL, 500 mL (120 mL standard) |
| Sample Throughput | 6 / 24 / 48 positions |
| Compatible Tube Volume | 1.5–200 mL |
| Heating Method | Water Bath |
| Gas Source | Nitrogen or Inert Gas |
| Max Gas Flow Rate | 15 L/min |
| Endpoint Detection | Infrared-based Quantitative Termination |
| Gas Flow Control | Independent per-channel with on/off valve |
| Airflow Design | Vortex-shear gas delivery |
| Safety Features | Real-time overheat/overpressure/low-water-level alerts |
| Viewing Window | Triple-side optical-grade transparent acrylic |
| Illumination | Adjustable 4-color LED bath lighting |
| Condensation Prevention | High-capacity axial exhaust fan |
| Brand | LabTech |
|---|---|
| Origin | Beijing, China |
| Model | Flex-MVP |
| Instrument Type | Vacuum Parallel Concentrator |
| Temperature Range | Ambient to 100 °C |
| Temperature Control Accuracy | ±1 °C |
| Throughput | 16-position |
| Sample Vial Compatibility | 200 mL, 50 mL, 40 mL (and other standard formats) |
| Sealing Architecture | Dual-mode (bulk + individual vial sealing) |
| Condensation System | Dual-tower cold trap for solvent vapor and off-gas recovery |
| Control Interface | 10-inch capacitive touchscreen with real-time parameter adjustment and gradient curve visualization |
| Brand | Lanjing |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Vacuum-Assisted Parallel Nitrogen Concentrator |
| Temperature Range | 15–35 °C (ambient operating range) |
| Temperature Control Accuracy | ±0.5 °C |
| Sample Vial Capacity | 0.5 mL and 1 mL (optical endpoint detection) |
| Max Channel Count | 64 |
| Heating Method | PTC-heated water bath with internal circulation |
| Display | 8-inch HD touch screen (800×480 resolution) |
| Power Supply | 220 V / 110 V, 50 Hz |
| Rated Power | 2200 W |
| Nitrogen Input Pressure Range | 7–145 psi |
| Output Pressure Range | 0–72.5 psi |
| Gas Flow Control | Electromagnetically actuated per-channel valves with calibrated needle valves and real-time pressure display |
| Sensor Technology | Fiber-optic level detection for automatic endpoint termination at 0.5 mL or 1 mL |
| Compliance | Designed for GLP-compliant laboratories |