Concentrators
Filter
Showing 1–30 of 67 results
| Brand | Amerlab |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | AE100 |
| Instrument Type | Automated Quantitative Concentrator |
| Temperature Range | Ambient to 250 °C |
| Temperature Control Accuracy | ±1 °C |
| Maximum Sample Capacity per Vial | 100 mL |
| Brand | ANAYN |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | CYNS-16K |
| Instrument Type | Vacuum Parallel Evaporator |
| Temperature Range | Ambient to 100 °C |
| Temperature Control Accuracy | ±1 °C |
| Throughput | 16 × 150–200 mL samples |
| Vacuum Pump Flow Rate | 20–30 L/min |
| Ultimate Vacuum | ≤8 mbar |
| Condensation System | Dual-tower cold trap with recirculating chiller |
| Display | 7-inch capacitive touchscreen interface |
| Sealing Interface | PFA-coated lid with threaded glass tube coupling |
| Chamber Volume | ≥8 L, triple-transparent viewing window |
| Safety Features | Low-water-level alarm, solvent recovery buffer bottle, PTFE diaphragm vacuum pump, PEEK/PTFE/glass fluid path |
| Compliance | Designed for GLP-compliant workflows |
| Brand | Annuo |
|---|---|
| Origin | Henan, China |
| Model | SC-4223 |
| Instrument Type | Automated Quantitative Gas Preconcentrator |
| Cold Trap Temperature Range | −30 °C to 300 °C (at 25 °C ambient) |
| Valve & Transfer Line Temperature Range | Ambient to 160 °C |
| Cooling Method | Peltier Thermoelectric |
| Sample Volume | 1–2000 mL |
| Maximum Concentration Ratio | 2000:1 |
| Precision | RSD ≤ 3% |
| Power Supply | AC 220 V, 50 Hz |
| Dimensions | 550 × 260 × 427 mm |
| Weight | ~20 kg |
| Interface Options | RS-232, Ethernet |
| GC Trigger Modes | Time-based or GC reverse control |
| Analysis Time Range | 0.1–999 min |
| Max Power Consumption | 1000 W |
| Brand | Annuo |
|---|---|
| Origin | Henan, China |
| Model | SC-4224 |
| Instrument Type | Automated Quantitative Gas Preconcentrator |
| Temperature Range (Valve & Tubing) | +5°C to 160°C |
| Cold Trap Temperature Range | −50°C to 300°C |
| Sample Volume Capacity | 1–2000 mL |
| Concentration Ratio | Up to 2000:1 |
| Temperature Control Accuracy | RSD ≤3% |
| Reproducibility | RSD ≤3% |
| Sample Introduction | Vacuum Pressure Sampling with MFC Flow Control |
| Cooling Method | Compressor-based |
| Dimensions (W×D×H) | 550 × 260 × 427 mm |
| Power Supply | AC 220 V, 50 Hz |
| Max Power Consumption | 1000 W |
| Weight | ~40 kg |
| Compliance | GB/T 14678–1993 |
| Brand | ANYAN (Hangzhou Anyan Instrument Co., Ltd.) |
|---|---|
| Origin | Zhejiang, China |
| Model | AYAN-25K |
| Instrument Type | Vacuum Parallel Concentrator |
| Temperature Range | Ambient to 100 °C |
| Temperature Control Accuracy | ±1 °C |
| Oscillation Speed | 0–300 rpm |
| Sample Capacity | 25 positions (150–200 mL vials) |
| Timer Range | 0–999 min |
| Heating Method | Water Bath |
| Included Systems | Integrated Vacuum Pump, Dual-Tower Condensation Module, Closed-Loop Water Circulation Chiller |
| Brand | Anyan Instrument |
|---|---|
| Origin | Zhejiang, China |
| Model | CHNS-25K |
| Instrument Type | Vacuum Parallel Concentrator |
| Temperature Range | Ambient to 100 °C |
| Temperature Control Accuracy | ±0.5 °C |
| Sample Capacity | 25 × 150–200 mL |
| Timing Range | 0–999 min |
| Heating Method | Circulating Water Bath |
| Condensation System | Dual-Tower Cold Trap with External Recirculating Chiller Support |
| Sealing Architecture | Individual Sample-Specific Vacuum Seals |
| Compliance | Designed for GLP-aligned workflows |
| Brand | Anyanyiqi |
|---|---|
| Origin | Zhejiang, China |
| Model | CHNS-16K |
| Instrument Type | Vacuum Parallel Concentrator |
| Temperature Range | Ambient to 100 °C |
| Temperature Control Accuracy | ±1 °C |
| Sample Capacity per Vial | 150 mL or 200 mL |
| Throughput | 1–16 samples simultaneously |
| Timer Range | 0–999 min |
| Heating Method | Water Bath |
| Brand | ATR |
|---|---|
| Origin | USA |
| Model | AutoVap S8 |
| Instrument Type | Automated Quantitative Concentrator |
| Temperature Range | Ambient to 99°C |
| Temperature Control Accuracy | ±0.5°C |
| Sample Volume Capacity | 0–50 mL (standard), optional 0–200 mL |
| Endpoint Detection | 0.5 mL or 1.0 mL optical sensing |
| Parallel Channels | 8 independent channels |
| Concentration Speed | 3–5× faster than conventional nitrogen blow-down systems |
| Sample Recovery Rate | ≥90% (typical, matrix-dependent) |
| Endpoint Precision | <5% volume error |
| Brand | ATR |
|---|---|
| Origin | USA |
| Model | S60 |
| Instrument Type | Automatic Quantitative Concentrator |
| Temperature Range | Ambient to 99°C |
| Temperature Control Accuracy | ±0.5°C |
| Sample Volume Capacity | 0–60 mL |
| Heating Method | Water Bath (Manufactured in Singapore) |
| Power Rating | 800 W |
| Gas Flow Rate | 0–8 L/min |
| Compatible Tube Sizes | 1.5 mL to 50 mL |
| Application Fields | Environmental (EPA), Pharmaceutical (FDA, USP), Clinical (CDC), Food Safety, Academic Research, and Chemical Analysis |
| Brand | Ji Aim |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | Auto C1 |
| Price Range | USD 28,000 – 56,000 |
| Instrument Type | Vacuum Centrifugal Concentrator |
| Temperature Range | Ambient to 70°C |
| Temperature Control Accuracy | ±2°C |
| Rotational Speed | 1500 rpm |
| Vacuum Display Range | 0.1–99.9 mbar |
| Vacuum Control | Yes |
| Heating Power | 1500 W |
| Power Supply | AC 220 V, 50/60 Hz, 10 A |
| Dimensions (W×D×H) | 657 × 518 × 465 mm |
| Lid Opening Mechanism | Vertical Lift |
| Positioning Accuracy | <1 mm |
| Rotor Configuration | Horizontal Dual-Plate Carrier (2 × 96-well Deep-Well Plates or Sample Vial Baskets) |
| Corrosion Resistance | Solvent-Compatible Materials (e.g., PTFE-coated Seals, 316 Stainless Steel Components) |
| Brand | BIOCOOL |
|---|---|
| Origin | Tianjin, China |
| Model | FastDry-1 |
| Instrument Type | Vacuum Centrifugal Concentrator |
| Temperature Range | Ambient to –80 °C |
| Temperature Control | Gradient PID Control |
| Sample Capacity | 132 × 1.5 mL tubes |
| Vacuum Pump Options | Diaphragm or Direct-Coupled Rotary Vane Pump |
| Ultimate Vacuum | <10 Pa |
| Rotational Speed | 400–1800 rpm (variable frequency drive) |
| Chamber & Rotor Coating | PTFE (Teflon®) |
| Control Interface | 7-inch Industrial Touchscreen + PLC |
| Safety Features | Vacuum-delayed spin initiation, Auto Venting, Overheat/Overpressure/Imbalance Protection |
| Compliance | Designed for GLP/GMP-aligned workflows |
| Brand | Biotage |
|---|---|
| Origin | Sweden |
| Model | Isolera Prime |
| Instrument Type | Automated Flash Chromatography System |
| Flow Rate | 1–100 mL/min |
| Maximum System Pressure | 10 bar (150 psi) |
| UV Detection Range | 200–400 nm (standard), optional 200–800 nm |
| Gradient Capability | Dual-solvent channels with TLC-driven gradient generation |
| Fraction Collection Options | 13 mm, 16 mm, 18 mm, 25 mm test tubes |
| Display | 10.4-inch capacitive touchscreen |
| Operating System | Embedded Linux |
| Connectivity | Ethernet-enabled for remote control, data logging, and network printing |
| Compliance | Compatible with GLP/GMP workflows via audit trail-ready software architecture |
| Brand | Biotage |
|---|---|
| Origin | USA |
| Model | V-10 Touch |
| Instrument Type | Vacuum Centrifugal Concentrator |
| Temperature Range | Ambient to 99 °C |
| Temperature Control Accuracy | ±0.1 °C |
| Sample Capacity | 0–1000 mL |
| Built-in Vacuum Pump | 2 mbar ultimate pressure |
| Maximum Rotor Speed | 8000 rpm |
| Brand | Detelogy |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Vacuum Parallel Concentrator |
| Model | MultiPro-V20 |
| Temperature Range | 0–100 °C |
| Temperature Control Accuracy | ±0.1 °C |
| Sample Capacity per Vial | 50–250 mL |
| Throughput | 20 Samples Simultaneously |
| Display | 10.1″ Capacitive Touchscreen |
| Vacuum System | Corrosion-Resistant Diaphragm Pump |
| Cooling | Dual Optional Condenser Tower |
| Automation | Auto Fill/Drain, Gradient Vacuum Control (20 Steps), Method Storage (32 Protocols) |
| Data Management | Audit Trail, USB Export, Remote Monitoring via DTLabs App |
| Brand | LabTech |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | ET Series |
| Instrument Type | Automatic Quantitative Concentrator |
| Temperature Range | Contact Manufacturer |
| Temperature Control Accuracy | Contact Manufacturer |
| Sample Capacity | Contact Manufacturer |
| Brand | EURO TECH |
|---|---|
| Origin | Shanghai, China |
| Model | ET3301A |
| Instrument Type | Purge-and-Trap Nitrogen Evaporator |
| Temperature Range | Ambient to 95 °C |
| Temperature Control Accuracy | ±1 °C |
| Maximum Sample Capacity | 60 samples |
| Gas Inlet Pressure | 60–100 psi |
| Maximum Gas Flow per Nozzle | 2 L/min |
| Timer Range | 1–999 min |
| Power Supply | 230 V, 50 Hz (optional 110 V, 60 Hz) |
| Dimensions (W×H×D) | 54 × 31 × 35 cm |
| Net Weight | 25 kg |
| Shipping Weight | 35 kg |
| Brand | EURO TECH |
|---|---|
| Origin | Shanghai, China |
| Model | ET3302B |
| Sample Capacity | 6 × 50 mL or 6 × 200 mL |
| Temperature Range | Ambient to 95 °C |
| Temperature Control Accuracy | ±1 °C |
| Gas Flow Control Range | 4–25 psi |
| Endpoint Detection Options | 0.5 mL or 1.0 mL (optical sensor) |
| Operating Modes | Auto-Endpoint, Manual, Timer, Auto-Endpoint + Timer |
| Water Bath Temp Range | Ambient to 60 °C |
| Power Supply | 220 VAC, 50 Hz |
| Dimensions (W×D×H) | 54 × 31 × 35 cm |
| Net Weight | 25 kg |
| Exhaust Port | 5 cm ID × 3 m exhaust hose included |
| Gas Inlet | 8 mm OD tubing |
| Recommended Gas Supply Pressure | ≥40 psi (regulated), max 100 psi |
| Typical Evaporation Rate | 2–8 mL/min (dependent on bath temp & gas flow) |
| Brand | EYELA (Tokyo Rikakikai Co., Ltd.) |
|---|---|
| Origin | Japan |
| Model | TVE-1100A / TVE-1100B |
| Concentration Principle | Vortex-assisted vacuum evaporation |
| Temperature Range | Ambient +5°C to 60°C (TVE-1100A), Ambient +5°C to 40°C (TVE-1100B) |
| Temperature Accuracy | ±0.2°C |
| Oscillation Speed | 100–1100 rpm (50/60 Hz) |
| Oscillation Amplitude | 3 mm |
| Gas Line Materials | PTFE, Polypropylene (PP), Viton®, Silicone Rubber, Borosilicate Glass |
| Vacuum & Vent Port OD | 10 mm |
| Drain Tube OD | 12 mm |
| Compatible Vessels | Centrifuge tubes (29 mm OD × 110 mm), Standard test tubes (Φ12–Φ18 mm × 100–180 mm), Straight-, flip-, screw-, and standard ground-glass joint formats |
| Operating Ambient | 5–35°C |
| Dimensions (W×D×H) | 300 × 500 × 670 mm |
| Brand | EYELA (Tokyo Rikakikai Co., Ltd.) |
|---|---|
| Origin | Japan |
| Model | VTX-2000 / VTX-2500 |
| Instrument Type | Automated Quantitative Vacuum Concentrator |
| Temperature Range | +10–80°C |
| Temperature Control Accuracy | ±1°C |
| Sample Capacity | 250 mL × 6 positions |
| Rotational Speed | 20–350 rpm |
| Ultimate Vacuum | 7 hPa (5 mmHg) |
| Cooling Water & Vacuum Port ID | 10 mm |
| Dimensions (W×D×H) | 670 × 570 × 710 mm |
| Weight | 35 kg |
| Brand | Genevac |
|---|---|
| Origin | United Kingdom |
| Model | EZ-2 4.0 Bionic |
| Instrument Type | Vacuum Centrifugal Concentrator |
| Temperature Range | 30 °C to 80 °C |
| Brand | Genevac |
|---|---|
| Origin | United Kingdom |
| Model | EZ-2 4.0 |
| Instrument Type | Automated Quantitative Concentrator |
| Temperature Range | 30–80 °C (±1 °C control accuracy) |
| Sample Volume Capacity | 1.5 mL to 500 mL |
| Maximum Rotor Load per Position | 1.5 kg |
| Centrifugal Force | Up to 500 × g |
| Solvent Boiling Point Limit | Up to 220 °C |
| Condenser Capacity | Unlimited (auto-drain enabled) |
| Refrigerant | Low-GWP hydrofluoroolefin (HFO) blend |
| Vacuum Source | Integrated scroll pump |
| Inert Gas Purge | IGP-compatible (N₂ or Ar) |
| Acid Resistance | HCl, HNO₃ compatible |
| Solvent Compatibility | Ethanol, DCM, EtOAc, ACN, H₂O, TFA, DMF, DMSO, ether, and others |
| Brand | Genevac |
|---|---|
| Origin | United Kingdom |
| Model | HT-3i |
| Instrument Type | Automated Quantitative Concentrator |
| Temperature Range | Ambient to 60 °C |
| Temperature Control Accuracy | ±1 °C within 50 °C |
| Sample Capacity | 0.2 mL to 6 L |
| Condenser | Integrated |
| User Interface | Touchscreen Control Software |
| Safety Features | Anti-bumping (Dri-Pure™), Auto-shutdown, HCl-resistant Construction, Inert Gas Purge Capability |
| Advanced Modes | LyoSpeed™ Fast Freeze-Drying, EXALT™ Controlled Crystallization |
| Design | Front-access Door, Multi-layer Rotor Architecture, Compact Footprint |
| Compatibility | Full Interchangeability with Genevac HT-Series Sample Holders |
| Automation Integration | Lab-automation Ready (e.g., robotic arm interface support) |
| Brand | Genevac |
|---|---|
| Origin | United Kingdom |
| Model | DNA |
| Instrument Type | Vacuum Centrifugal Concentrator |
| Temperature Range | Ambient, 30–80 °C (adjustable in 1 °C increments) |
| Vacuum Level | 10 mbar |
| Rotational Speed | 1465 rpm |
| Dimensions (W×D×H) | 360 × 597 × 300 mm |
| Weight | 34 kg |
| Rotor Configurations | 48 × 1.5 mL tubes, 12 × 15 mL tubes, 8 × 50 mL tubes, 96-well microplates |
| Cold Trap | Not included |
| Pressure Controller | Not included |
| Operating Modes | Water, Alcohol, Other Solvents |
| Sample Compatibility | Tubes, microcentrifuge tubes, vials, round-bottom flasks, 96-well plates |
| Brand | GeneVac |
|---|---|
| Origin | United Kingdom |
| Model | DUO |
| Instrument Type | Vacuum Centrifugal Concentrator |
| Sample Capacity | 50 mL (max per rotor position) |
| Temperature Range | Ambient, 30–80 °C (1 °C increments) |
| Vacuum Level | Down to 10 mbar |
| Rotational Speed | 1465 rpm |
| Cold Trap Temperature | −50 °C |
| Cold Trap Operation Modes | Manual Defrost / Auto-Defrost / Continuous Condensation |
| Rotor Configurations | 48 × 1.5 mL tubes, 12 × 15 mL tubes, 8 × 50 mL tubes, 96-well microplates |
| Operating Modes | Water, Alcohol, Other Solvent Profiles |
| Brand | GeneVac |
|---|---|
| Origin | United Kingdom |
| Model | QUATTRO |
| Instrument Type | Vacuum Centrifugal Concentrator |
| Temperature Range | Ambient to 80 °C (adjustable in 1 °C increments) |
| Vacuum Level | 2 mbar |
| Rotational Speed | 1130 rpm |
| Cold Trap Temperature | −50 °C |
| Cold Trap Modes | Manual Defrost / Auto Defrost / Continuous Condensation |
| Rotor Configurations | 200 × 1.5 mL tubes, 72 × 15 mL tubes, 36 × 50 mL tubes, 96-well microplates |
| Operating Modes | Water, Alcohol, Other Solvents |
| Brand | GeneVac |
|---|---|
| Origin | United Kingdom |
| Model | Rocket Synergy2 |
| Instrument Type | Vacuum Centrifugal Concentrator |
| Temperature Range | +5 °C to 60 °C (±1 °C accuracy) |
| Temperature Control Precision | ±1 °C across 30–80 °C operating band |
| Rotational Speed | 1800 rpm |
| Relative Centrifugal Force (RCF) | 700 × g |
| Maximum Sample Volume per Vessel | 450 mL |
| Standard Capacity | 6 positions (450 mL each) |
| Expandable Capacity | 18 positions with Puck accessory |
| Sample Vessel Options | 60 mL, 250 mL, 400 mL, 450 mL |
| Automated Solvent Addition | Up to 100 L total (via integrated peristaltic dosing module) |
| Ultimate Vacuum | 3 mbar (oil-free PTFE diaphragm pump) |
| Cold Trap | Dual-stage, frost-free, auto-drain capable |
| Real-time Monitoring | Stroboscopic viewing window |
| Programmability | 15 user-storable methods |
| Data Interface | USB for method upload/download and audit log export |
| SampleGenie™ Compatibility | Yes (direct-to-vial concentration & quantitative endpoint control) |
| Dri-Pure® Anti-Bumping Technology | Integrated |
| Brand | Tianjin HengAo |
|---|---|
| Origin | Tianjin, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Automated Quantitative Concentrator |
| Temperature Range | Ambient +5 °C to 100 °C |
| Temperature Control Accuracy | ±0.5 °C |
| Sample Capacity per Position | 150 mL |
| Throughput | 12 Samples Simultaneously |
| Endpoint Detection | Fixed Volume (0.5 mL or 1 mL) Automatic Termination |
| Vacuum & Heating & Orbital Shaking | Integrated Simultaneous Operation |
| Solvent Recovery | Condensate Collection Enabled |
| Cooling Water Circulator & Vacuum Controller | Optional Accessories |
| Brand | Tianjin HengAo |
|---|---|
| Origin | Tianjin, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Vacuum Centrifugal Concentrator |
| Temperature Range | Ambient +5°C to 100°C |
| Temperature Control Accuracy | ±0.5°C |
| Sample Capacity per Position | 30 mL (24-position configuration) |
| Total Throughput Capacity | 720 mL (24 × 30 mL) |
| Position Designation | “HPE-24” indicates 24 sample positions |
| Quantitative Mode Option | Available with “A” suffix for endpoint volume control (e.g., 0.5 mL or 1.0 mL stop points) |
| Brand | Tianjin HengAo |
|---|---|
| Origin | Tianjin, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Automated Quantitative Concentrator |
| Temperature Range | Ambient +5°C to 100°C |
| Temperature Control Accuracy | ±0.5°C |
| Sample Capacity per Position | 200 mL |
| Maximum Throughput | 24 Samples Simultaneously |
| Evaporation Mode | Simultaneous Vacuum Reduction, Heated Water Bath, and Orbital Vortex Agitation |
| Solvent Recovery Efficiency | High |
| Footprint | Benchtop, Ventilation Hood-Compatible |
| Brand | Tianjin HengAo |
|---|---|
| Origin | Tianjin, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Vacuum Centrifugal Concentrator |
| Model | HPE-66B |
| Temperature Range | Ambient +5°C to 100°C |
| Temperature Control Accuracy | ±0.5°C |
| Sample Capacity per Position | 1 mL (compatible with 50–200 mL tubes) |
| Rotational Radius | 5 mm |
| Speed Range | 0–600 rpm |
| Heating Method | PTC Water Bath with Lid Heating |
| Vacuum Control Range | Adjustable down to ≤5 mbar (display resolution: 1 mbar |
| manual control precision | 10 mbar) |
| Gradient Programs | Up to 5 segments, 30 pre-stored methods |
| Max Total Program Duration | 42.5 hours |
| Display | 5-inch capacitive touchscreen with real-time pressure/temperature curve logging |