| Brand | TAITEC |
|---|---|
| Origin | Japan |
| Model | VC-36R / VC-96R |
| Instrument Type | Vacuum Centrifugal Concentrator |
| Temperature Range | +4°C to +70°C |
| Temperature Control Accuracy | ±0.1°C |
| Sample Capacity | 2.0 mL × 96 (VC-96R) |
| Rotational Speed | 300–2000 rpm (max 440 × g with 36A rotor) |
| Vacuum Range | 0 to –0.1 MPa |
| Timer | 1 min to 99 h 59 min (digital) |
| Chamber Material | SUS304 stainless steel with PTFE coating |
| Lid Material | PVC |
| Vacuum & Vent Nozzle Diameters | Exhaust Φ14 mm, Vent Φ6 mm, Cooling Water Φ12 mm |
| Safety Features | Overcurrent protection, automatic shutdown upon lid opening (heater/rotor/vacuum pump), real-time thermal and motor diagnostics with non-volatile memory logging |
| Brand | TAITEC |
|---|---|
| Origin | Japan |
| Model | VC-96W |
| Instrument Type | Vacuum Centrifugal Concentrator |
| Temperature Range | Room Temperature +5°C to +65°C |
| Temperature Control Accuracy | ±0.1°C |
| Maximum Sample Capacity | 200 mL |
| Rotational Speed | 100–2600 rpm (up to 800 × g with 96S swing rotor) |
| Timer Range | 1–99 min |
| Chamber Material | SUS316 stainless steel with PTFE coating |
| Lid Material | PVC |
| Vacuum Gauge | 0 to –0.1 MPa (Bourdon tube) |
| Vacuum Release | Manual |
| Heating Method | Far-infrared heater |
| Safety Features | Lid interlock power cutoff, independent overheat protection sensor, motor circuit breaker, real-time anomaly display (power failure, rotation error, lid open) |
| Brand | Titan Instruments |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Category | Domestic |
| Model | APNE-12 |
| Pricing | Available Upon Request |
| Instrument Type | Automated Quantitative Concentrator |
| Temperature Range | Ambient to 70 °C |
| Temperature Control Accuracy | ±0.1 °C |
| Maximum Sample Volume per Vial | ≤200 mL |
| Brand | Titan Instruments |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | APNE-12 |
| Instrument Type | Automated Quantitative Nitrogen Concentrator |
| Temperature Range | Ambient to 70 °C |
| Temperature Control Accuracy | ±0.1 °C |
| Maximum Sample Volume per Vial | ≤200 mL |
| Brand | TOMY |
|---|---|
| Origin | Japan |
| Model | MV-100 |
| Maximum Speed | 2,600 rpm (50 Hz) / 2,800 rpm (60 Hz) |
| Maximum RCF | 400 × g (50 Hz) / 465 × g (60 Hz) |
| Capacity | 12 × 1.5 mL tubes |
| Drive System | Magnetic coupling drive |
| Vacuum Pump | Integrated oil-free vacuum pump |
| Ultimate Vacuum | 27 hPa (20 Torr) |
| Vacuum Range | 0–0.1 MPa (0–76 cmHg) |
| Heating Capability | Ambient to 55 °C (adjustable, with thermal cutoff) |
| Chamber Material | SUS-304 stainless steel |
| Lid Material | Transparent acrylic resin |
| Inlet Filter | 0.2 µm hydrophobic membrane |
| Exhaust Filter | Aerosol trap |
| Safety Interlock | Lid-open/stop motor interlock + 5 A fuse |
| Net Weight | 7.2 kg |
| Dimensions (W×D×H) | 200 × 205 × 230 mm |
| Power Input | AC 110–120 V, 50/60 Hz, 3 A |
| Brand | WIGGENS |
|---|---|
| Origin | Germany |
| Model | WB-502C |
| Temperature Range | 4–80 °C |
| Temperature Accuracy | ±0.1 °C |
| Sample Capacity | 132 × 1.5 mL tubes |
| Max Rotor Speed | ≤1500 rpm |
| Vacuum System | PTFE-coated diaphragm pump (WIGGENS C410), ultimate vacuum ≥13 mbar |
| Integrated Cold Trap | −20 °C |
| Heating Options | IR-only / IR + conductive / conductive-only |
| Timer Range | 00:01–99:59 (h:min) |
| Dimensions (W×D×H) | 670 × 685 × 480 mm |
| Power Supply | 220 V, 50/60 Hz, 1200 W |
| Brand | WIGGENS |
|---|---|
| Origin | Germany |
| Model | WB-504C |
| Instrument Type | Vacuum Centrifugal Concentrator |
| Temperature Range | 4–80 °C |
| Temperature Control Accuracy | ±0.1 °C |
| Sample Capacity | 250 mL × 4 positions |
| Rotational Speed | ≤1500 rpm |
| Ultimate Vacuum | ≥2 mbar |
| Cold Trap | −20 °C, 2 L collection volume |
| Dimensions (W×D×H) | 600 × 630 × 1085 mm |
| Weight | 138 kg |
| Power Supply | 220 V, 50/60 Hz |