| Brand | ATSFAAR |
|---|---|
| Origin | Italy |
| Manufacturer Authorization Status | Authorized Distributor |
| Import Status | Imported |
| Model No. | 10097101 |
| Power Supply | 400 V AC, 50 Hz, 3-phase, 32 A |
| Fuel Gas | Methane |
| Display | 17-inch integrated touchscreen |
| Standards Compliance | ISO 5660-1, ASTM E1354, BS EN ISO 5660-1, NFPA 271 |
| Key Measured Parameters | Heat Release Rate (HRR), Time to Ignition (TTI), Mass Loss Rate (MLR), Effective Heat of Combustion (EHC), Smoke Production Rate (SPR), CO/CO₂ Yield, Oxygen Consumption |
| Brand | FTT |
|---|---|
| Origin | United Kingdom |
| Model | iCone |
| Compliance | ISO 5660-1 & -2, ASTM E1354, ASTM E1740, ASTM F1550, ASTM D5485, ASTM D6113, NFPA 271, NFPA 264, CAN/ULC-S135, BS 476-15, GB/T 16172 |
| Heat Flux Range | Up to 100 kW/m² |
| Sample Size | 100 mm × 100 mm (max thickness 50 mm) |
| Mass Loss Resolution | 0.01 g |
| Exhaust Flow Rate | 24 L/s |
| Oxygen Analysis | Paramagnetic or Zirconia-based O₂ sensor |
| Smoke Obscuration | He–Ne laser (0.5 mW), Si photodiode detector with ND filters (0.3 & 0.8) |
| Ignition Source | 10 kV spark igniter with auto-positioning and safety cutoff |
| Data Acquisition | Synchronized multi-channel, 100 Hz sampling rate |
| Software | ConeCalc v6.x (Windows-based, multilingual UI) |
| Brand | FTT |
|---|---|
| Origin | United Kingdom |
| Model | Oxygen Bomb Calorimeter |
| Standards Compliance | ISO 1716, ISO 1928, ASTM D240, ASTM D4809, ASTM D5468, ASTM D5865, ASTM E711 |
| Application Scope | Gross Calorific Value (GCV) determination of solid, liquid, and heterogeneous fuels and combustible materials |
| Configuration | Includes main calorimeter unit, high-pressure oxygen bomb assembly, oxygen charging station, calibration accessories (benzoic acid standard, ignition wire, crucibles), and installation kit |
| Brand | MOTIS |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | SBI |
| Pricing | Available Upon Request |
| Compliance | EN 13823, GB/T 20284 |
| Core Measurement Principle | Oxygen Consumption Calorimetry & Optical Smoke Density Analysis |
| Key Outputs | FIGRA, THR, SMOGRA, TSP, LFS, Droplet Observation |
| Brand | MOTIS |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | SBI |
| Pricing | Available Upon Request |
| Standards Compliance | EN 13823, GB/T 20284 |
| Core Measurement Principles | Oxygen depletion calorimetry, optical smoke density analysis, flame spread observation, droplet collection |
| Key Outputs | FIGRA, THR, SMOGRA, TSP, LFS, flaming droplets/particles |
| Brand | MOTIS |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | SBI |
| Pricing | Upon Request |
| Standards Compliance | EN 13823, GB/T 20284 |
| Measurement Principles | Oxygen depletion calorimetry, optical smoke density analysis, flame spread observation, droplet collection |
| Key Outputs | FIGRA, THR, SMOGRA, TSP, LFS, flaming droplets/particles |
| Brand | Netzsch |
|---|---|
| Origin | Germany |
| Model | TCC918 Cone Calorimeter |
| Cone Heater | 220 V, 5 kW, adjustable heat flux 0–100 kW/m² |
| Thermocouple Accuracy | ±0.5 °C, tolerance 0.004 |
| Specimen Holder | 100 × 100 × 50 mm (expandable for vertical drip testing) |
| Load Cell | 8.2 kg max capacity, resolution 0.01 g, linearity ±0.02 g |
| Heat Flux Meter | fully automated control, accuracy ±2%, repeatability ±0.5% |
| O₂ Analyzer | paramagnetic, 0–25% vol, accuracy 0.001%, noise & drift <100 ppm |
| CO₂ Analyzer | NDIR, 0–10% vol, accuracy 0.001% |
| CO Analyzer | NDIR, 0–1% vol, accuracy 0.001% |
| C-factor Range | 0.036–0.044, calibration deviation ≤5% |
| Peltier Cooling | down to −10 °C |