| Brand | Shanghai Yiheng |
|---|---|
| Origin | Chongqing, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | DHG-9005 (Drying Oven Series) |
| Instrument Type | Precision Drying Oven |
| Temperature Range | RT+10°C to 300°C |
| Temperature Uniformity | ±3% at 100°C |
| Temperature Fluctuation | ±1.0°C |
| Interior Material | Mirror-Finish Stainless Steel (A-Series) |
| Heating Method | Forced-Air Convection |
| Brand | Shanghai Yiheng |
|---|---|
| Origin | Shanghai, China |
| Model | DU-20 / DU-30 / DU-30G |
| Bath Volume | 12 L / 20 L |
| Temperature Range | RT+20 °C to 200 °C |
| Temperature Stability | ±0.5 °C |
| Control Mode | Heating-only PID |
| Circulation Type | Internal & External |
| Stirring | Magnetic (DU-20G/DU-30G only) |
| Power Input | 1000 W (DU-20/DU-20G/DU-30G), 1600 W (DU-30) |
| Timer Range | 0–9999 min |
| Alarm Threshold | +2 °C above setpoint |
| Inner Chamber Dimensions (W×D×H) | 250×250×200 mm (DU-20/DU-20G), 400×250×200 mm (DU-30/DU-30G) |
| Brand | Shanghai Yiheng |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Models | DU-3GW / DU-3GO |
| Instrument Type | Water Bath / Oil Bath |
| Circulation Function | Non-circulating |
| Temperature Control Mode | Heating-Only |
| Bath Volume | 5.5 L |
| Temperature Range | RT+5–99°C (DU-3GW) / RT+5–200°C (DU-3GO) |
| Temperature Stability | ±0.5°C |
| Temperature Fluctuation | ±0.5°C |
| Stirring Speed Range | 0–1800 rpm |
| Internal Bath Dimensions (Ø × H) | Ø230 × 130 mm |
| Heating Power | 1000 W |
| Max Flask Capacity | 3000 mL |
| Power Supply | 220 V, 50 Hz |
| Display | LCD with Rotary Knob Interface |
| Dual-Sensor System | Bath Fluid Temp / External Vessel Temp |
| Safety Features | Independent Over-Temperature Alarm, Flame-Retardant Housing, Fume Hood Compatible Design |
| Motor Type | High-Durability DC Brushless Motor |
| Heating Element Material | ASTM A240 Type 304 Stainless Steel |
| Magnet Type | High-Temperature Rare-Earth Permanent Magnet (Rated >200°C Continuous Duty) |
| Brand | Shanghai Yiheng |
|---|---|
| Origin | Shanghai, China |
| Model | DZF-6030A |
| Type | Vacuum Oven |
| Temperature Range | RT+10°C to 200°C |
| Temperature Uniformity | ±1°C |
| Temperature Resolution | 0.1°C |
| Achievable Vacuum Level | 133 Pa |
| Interior Dimensions | 320 × 320 × 300 mm |
| Exterior Dimensions | 630 × 510 × 490 mm |
| Interior Material | Stainless Steel |
| Heating Power | 400 W |
| Shelf Capacity | 1 adjustable stainless steel shelf |
| Door | Double-layer tempered glass with silicone gasket seal |
| Brand | Shanghai Yiheng |
|---|---|
| Origin | Shanghai, China |
| Model | DZF-6030B |
| Temperature Range | RT+10 to 65 °C |
| Temperature Uniformity | ±1 °C |
| Temperature Resolution | 0.1 °C |
| Ultimate Vacuum | 133 Pa |
| Interior Dimensions | 320 × 320 × 300 mm (W×D×H) |
| Exterior Dimensions | 610 × 510 × 490 mm (W×D×H) |
| Chamber Material | Stainless Steel (AISI 304) |
| Heating Method | Electric Resistive Heating |
| Power Consumption | 250 W |
| Standard Shelf | 1 pc |
| Door Type | Double-Layer Tempered Glass with Silicone Gasket |
| Brand | Shanghai Yiheng |
|---|---|
| Origin | Shanghai, China |
| Model | DZF-6053 |
| Instrument Type | Vacuum Oven |
| Temperature Range | RT+10°C to 200°C |
| Temperature Uniformity | ±1°C |
| Temperature Resolution | 0.1°C |
| Achievable Vacuum Level | 133 Pa |
| Internal Chamber Dimensions | 415 × 370 × 345 mm |
| External Dimensions | 730 × 560 × 550 mm |
| Chamber Material | Stainless Steel (SUS304) |
| Heating Method | Electric Resistance Heating |
| Power Input | 1400 W |
| Standard Shelves | 3 pcs |
| Door | Double-layer Tempered Glass with Silicone Sealing Gasket |
| Brand | Shanghai Yiheng |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic (China-Made) |
| Model Series | GRX Series |
| Instrument Type | High-Temperature Forced-Air Oven |
| Temperature Range | RT+10°C to 200°C / RT+10°C to 250°C |
| Temperature Uniformity | ±1°C |
| Heating Method | Forced Convection with Adjustable Fan Speed |
| Key | Brand: Shanghai Yiheng |
|---|---|
| Origin | Shanghai, China |
| Model | HWS-12 / HWS-24 / HWS-26 / HWS-28 |
| Power Consumption | 500 W / 1000 W / 1500 W / 2000 W |
| Temperature Range | RT+5 °C to 99 °C |
| Temperature Stability | ±0.5 °C |
| Bath Volume | 4.9 L / 9.9 L / 14.8 L / 19.8 L |
| Inner Chamber Dimensions (W×D×H, mm) | 347×201×155 / 376×347×165 / 496×347×165 / 600×300×110 |
| External Dimensions (W×D×H, mm) | 455×201×183 / 483×347×194 / 603×347×194 / 752×345×210 |
| Timer Range | 0–999 min |
| Alarm Threshold | +2 °C above setpoint |
| Chamber Material | Stainless Steel 304 |
| Well Configurations | 2-, 4-, 6-, or 8-hole dual-row layout |
| Well Diameters | Ø32 / Ø52 / Ø72 / Ø92 / Ø112 mm |
| Brand | Shanghai Yiheng |
|---|---|
| Origin | Shanghai, China |
| Model Series | MP / MPG / CD Series |
| Temperature Range | +5 °C to +100 °C (MP/MPG), −20 °C to +150 °C (CD-200F) |
| Temperature Stability | ±0.03 °C to ±0.2 °C |
| Bath Volume | 6.7 L to 22.5 L |
| Bath Opening × Depth | 150×160×150 mm to 240×390×650 mm |
| Circulation Flow Rate | 8 L/min |
| Heating Power | 1050 W (MP/MPG), unspecified for CD-200F |
| Refrigeration | Yes (CD-200F only) |
| Control System | Microprocessor-based PID with LCD display, programmable ramp/soak profiles |
| External Circulation | Yes, with pressure-suction pump and dual external ports |
| Safety Features | Over-temperature, low-temperature, and low-level audiovisual alarms |
| Compliance | Designed for GLP-compliant laboratory environments |
| Brand | Shanghai Yiheng |
|---|---|
| Origin | Shanghai, China |
| Model Series | MP, MPG, MPE, MPGE |
| Temperature Range | −50 °C to 100 °C (model-dependent) |
| Temperature Stability | ±0.02 °C (MPE/MPGE high-precision models) |
| Control Accuracy | ±0.1 °C (MP/MPG standard models) |
| Bath Opening × Depth | 150 mm × 160 mm × 150 mm (standard) / 240 mm × 170 mm × 200 mm (large-volume MPG/MPGE) |
| Reservoir Volume | 4.5 L to 13 L |
| Circulation Flow Rate | 8 L/min (adjustable) |
| Heating Power | 2300 W to 3100 W |
| Refrigeration | Eco-friendly R-404A or R-507 refrigerant |
| Power Supply | AC 220 V, 50 Hz |
| External Circulation | Yes (pressure-suction pump with dual-port interface) |
| Internal/External Dual-Circulation Mode | Yes |
| Safety Features | Over-temperature, low-temperature, and low-level liquid alarms with audible/visual alerts |
| Optional | RS-485, USB data export (U-disk), printer interface, multi-segment programmable controller (7 programs × 63 steps, time per step: 1–99 h 59 min) |
| Brand | TAITEC |
|---|---|
| Origin | Japan |
| Model | DC-280 |
| Instrument Type | Vacuum Oven |
| Temperature Range | +30 °C (heating plate surface under vacuum) |
| Chamber Dimensions | 258 × 250 mm (W × D), 3 shelves (aluminum) |
| External Dimensions | 430 × 400 × 615 mm (W × D × H) |
| Weight | ~21 kg |
| Power Supply | AC 100 V, 3 A (main unit) |
| Heating Power | 100 W per shelf, independently switchable |
| Vacuum Gauge | Bourdon tube type |
| Exhaust/Inlet Nozzles | Two Ø14 mm ports (separate vacuum evacuation and gas inlet/exchange) |
| Vacuum Release | Manual needle valve (Ø9 mm, dual-purpose for venting and gas exchange) |
| Internal Socket | AC 100 V, 3 A rated, for in-chamber devices (e.g., magnetic stirrers) |
| Recommended Vacuum Pump | 50–100 L/min displacement |
| Compliance | Designed for laboratory use in accordance with JIS Z 8101-1 (general principles of drying equipment) and compatible with ISO 17025-accredited workflows requiring traceable thermal conditioning |
| Brand | TAITEC |
|---|---|
| Origin | Japan |
| Model | DTU-1BN / DTU-2BN / DTU-1CN / DTU-2CN |
| Temperature Range | Ambient +5°C to +110°C (B-series) or +200°C (C-series) |
| Temperature Accuracy | ±0.1°C |
| Heating Time to 100°C | ≤15 min |
| Dimensions (W×D×H) | 210×318×130 mm (DTU-1BN/1CN), 318×318×130 mm (DTU-2BN/2CN) |
| Net Weight | 4 kg (DTU-1BN/1CN), 6 kg (DTU-2BN/2CN) |
| Power Supply | AC 100 V, 1.3–2.8 A |
| Heating Power | 100 W (DTU-1BN), 150 W (DTU-2BN), 180 W (DTU-1CN), 250 W (DTU-2CN) |
| Timer Range | 1 min – 99 h 59 min |
| Safety Features | Auto-reset high-temp cutoff, overcurrent protection, overheat protection, sensor fault detection (open/short circuit) |
| Display | Dual-digit LED (setpoint & real-time temperature) |
| Optional Accessories | Interchangeable deep-well aluminum blocks (AL-xxx series), nitrogen blow-down heads (E1/E2 series, 5–72 nozzles) |
| Brand | TAITEC |
|---|---|
| Origin | Japan |
| Model | eB-ShakerUnit |
| Oscillation Mode | Reciprocating |
| Speed Range | 30–150 rpm |
| Amplitude | 10 mm |
| Operating Ambient Temperature | +5°C to +35°C |
| Unit Dimensions | 150 × 120 × 190 mm (W × D × H) |
| Platform Dimensions | 85 × 115 × 20 mm (W × D × H) |
| Power Supply | AC 100 V, 0.25 A |
| Compatible Units | EIB, ECB, ETB (EFB excluded) |
| Optional Accessory | PCA-01 Mounting Kit for Thermo Minder C-Type Plastic Bath (Min. Internal Dimensions: 180 × 320 × 155 mm |
| Max. Temp. Resistance | +70°C) |
| Brand | TAITEC |
|---|---|
| Origin | Japan |
| Model | M-130 |
| Temperature Range | 3–50°C (Standard), 10–45°C (Illuminated Version) |
| Temperature Uniformity | ±0.1–0.5°C (Precision Mode), ±1.0–2.0°C (Eco Mode) |
| Control Resolution | 0.1°C (Precision), 1.0°C (Eco) |
| Internal Volume | ~85 L |
| Interior Dimensions | 563 × 378 × 412 mm (W×D×H) |
| External Dimensions | 633 × 435 × 1078 mm (W×D×H) |
| Net Weight | ~60 kg (Standard), ~85 kg (Illuminated) |
| Power Supply | AC 100 V, 6 A / 8 A |
| Heating Capacity | 350 W |
| Cooling Capacity | 75 W |
| Internal Socket | 1 × 3 A outlet |
| Air Circulation | Forced-air convection with internal fan |
| Defrost Control | Manual override button for auto-defrost disable |
| Interior Material | SUS304 stainless steel |
| Door Lock | Sliding mechanical lock with key |
| Accessories | Drip tray ×1, water collection pan ×1, waterproof plug ×1, sliding door lock ×1 |
| Brand | TAITEC |
|---|---|
| Origin | Japan |
| Model | M-16N |
| Instrument Type | General-Purpose Forced-Convection Oven |
| Temperature Range | Ambient +5°C to 80°C |
| Temperature Uniformity | ±0.25°C to ±0.95°C |
| Chamber Dimensions (W×D×H) | 460 × 400 × 1200 mm |
| External Dimensions (W×D×H) | 610 × 535 × 1630 mm |
| Heating Power | 400 W × 5 elements |
| Air Circulation | Forced convection via internal blower |
| Sterilization Lamp | 6 W UV-C lamp with 60-min mechanical timer |
| Control System | Pt-based proportional-integral time-ratio controller |
| Interior Material | Stainless steel (SUS304) |
| Door | Full-view tempered glass |
| Shelving | 3 adjustable stainless steel shelves |
| Drain Pan | Integrated removable drip tray |
| Filtration | Built-in particulate air filter |
| Power Supply | AC 100 V, 21 A |
| Weight | Approx. 98 kg |
| Brand | TAITEC |
|---|---|
| Origin | Japan |
| Model | M-210FN |
| Temperature Range | 0°C to +45°C (Standard) |
| Temperature Uniformity | ±1.0–2.0°C |
| Internal Volume | ~392 L |
| Internal Dimensions | 494 × 646 × 1200 mm (W × D × H) |
| External Dimensions | 600 × 800 × 1905 mm (W × D × H) |
| Net Weight | ~103 kg (Standard), ~112 kg (Illuminated) |
| Power Supply | AC 100 V, 6.5 A (Standard), 9 A (Illuminated) |
| Heating Capacity | 200 W |
| Refrigeration | Sealed Air-Cooled System, 200 W |
| Air Circulation | Forced Convection |
| Interior Material | SUS304 Stainless Steel |
| Exterior Material | SUS304 Stainless Steel |
| Max Load Capacity | ~50 kg |
| Built-in Outlets | 2 × Airtight 5 A Sockets |
| Defrost Control | Toggleable Auto-Defrost (6-hr cycle, 15-min intervals) |
| Illumination | 4 × 40 W Fluorescent Lamps, ~8000 lux (M-210FN Illuminated Variant Only) |
| Accessories | Drip Tray ×1, Shelf Plates ×3, Water Collection Pan ×1, Shelf Supports ×1 |
| Brand | TAITEC |
|---|---|
| Origin | Japan |
| Model | Monosin II-A |
| Oscillation Mode | Dual-configuration (Orbital Balance Mode & Linear Reciprocating Mode) |
| Speed Range | 20–160 rpm |
| Amplitude Adjustment | 0°–24° (orbital, continuous) |
| Chamber Internal Dimensions (Orbital) | 355 × 460 × 165 mm (H) |
| Chamber Internal Dimensions (Reciprocating) | 290 × 460 × 165 mm (H) |
| Platform Type | Spring-grid platform (reciprocating) / L-shaped tube fixture array (orbital) |
| Compatible Vessels | ∅18 mm L-tubes (17 × 2 rows), ∅16 mm vertical tubes (144 pcs), 100 mL conical flasks (15 pcs), 200 mL (8 pcs), 300 mL (6 pcs), 500 mL (3 pcs) |
| Max Clamp Thickness | ≤70 mm |
| Power Supply | AC 100 V, 1 A |
| Net Weight | ~15 kg (orbital), ~16 kg (reciprocating) |
| Compliance | Designed for ISO/IEC 17025-aligned laboratory environments |
| Key | Brand: TAITEC |
|---|---|
| Origin | Japan |
| Model(s) | SM-05N, SJ-07N, SP-12N |
| Temperature Range | RT+5°C to +85°C (SM-05N), RT+5°C to +95°C (SJ-07N), RT+5°C to +100°C (SP-12N) |
| Temperature Stability | ±0.1°C |
| Control Method | PID with Thermistor Sensor |
| Circulation Type | Internal Recirculation Only |
| Heating Power | 500 W (SM-05N), 700 W (SJ-07N), 1200 W (SP-12N) |
| Bath Volume Capacity | Not Specified (Compatible with Optional Polyethylene C-type Bath: 6 L nominal) |
| Stirring Mechanism | Adjustable Jet Flow |
| Timer Functions | Set-Time Alert Timer (1 min–99 h 59 min), Auto-Off Timer (1 min–99 h 59 min) |
| Safety Features | Dry-run Prevention Float Switch, Over-Temperature & Low-Water Alarms, Sensor Fault Detection, Non-Volatile Memory Error Logging, Heater Guard Enclosure, Circuit Protection (8 A / 10 A / 15 A), Fuse (2 A) |
| Power Supply | AC 100 V, 50/60 Hz |
| Compliance | Designed for GLP-compliant lab environments |
| Brand | Taitec |
|---|---|
| Origin | Japan |
| Model | SX-10N, SH-10N |
| Temperature Range | RT+5°C to +105°C (SX-10N), RT+5°C to +180°C (SH-10N) |
| Temperature Stability | ±0.05°C (SX-10N), ±0.1°C (SH-10N) |
| Control Type | Heating-Only, Platinum Pt100 PID Controller |
| Circulation | Internal Jet-Type Flow |
| Stirring Adjustment | Continuously Variable Flow Knob |
| Timer Functions | Set-Time Alert Timer (1 min–99 h 59 min), OFF Timer (1 min–99 h 59 min), Temperature-Transition Timer |
| Temperature Memory | 1 Preset Slot |
| Safety Features | Dry-run Prevention (Float-Type for SX-10N, Flow-Sensing for SH-10N), Over-Temp/Under-Temp Alarm, Low-Level Detection, Sensor Fault Detection, Non-Volatile Memory Error Monitoring, Heater Guard, Circuit Protection (10A/15A), Dual Fuses (2A) |
| Power Supply | AC100V, 50/60Hz, 5.5A (SX-10N), 11A (SH-10N) |
| Weight | 3.4 kg (SX-10N), 5.0 kg (SH-10N) |
| Compliance | RoHS Directive |
| Brand | Tamson Instruments |
|---|---|
| Origin | Netherlands |
| Model | TC16 / TC40 / TC58 |
| Bath Volume | 16 L / 40 L / 58 L |
| Temperature Range | Ambient to 250 °C |
| Temperature Stability | ±0.02 °C |
| Circulation Type | Internal recirculation |
| Compliance | CE-marked |
| Safety Feature | Mechanical resettable safety thermostat |
| Communication Interface | RS232 |
| Software | Free Tamcom control and data logging software |
| Unit Options | °C (standard), °F (on request) |
| Brand | Tamson Instruments |
|---|---|
| Origin | Netherlands |
| Model | TLB50 |
| Instrument Type | Constant-Temperature Circulating Bath |
| Circulation Mode | Internal & External |
| Temperature Control | Refrigeration & Heating |
| Bath Volume | 50 L |
| Temperature Range | −5 °C to +80 °C |
| Temperature Stability | ±0.02 °C |
| Brand | Tamson Instruments |
|---|---|
| Origin | Netherlands |
| Model | TLC15-5 |
| Bath Volume | 5 L |
| Temperature Range | –15 °C to +60 °C |
| Temperature Stability | ±0.02 °C |
| Circulation Type | Internal & External |
| Cooling/Heating Mode | Dual-function |
| Display Unit | °C or °F selectable |
| Refrigerant | Ozone-friendly (CFC-/HCFC-free) |
| Safety Features | Mechanical safety thermostat, liquid level float indicator |
| Compliance | CE-marked |
| Interface | RS232 with Tamcom software support |
| Control System | Microprocessor-based PID with user-adjustable parameters |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Model | F6000-60 / F30400-60 |
| Temperature Range | 100–975 °C |
| Chamber Volume | 15 L or 45 L |
| Air Flow Control | 0–80 L/min (adjustable via front-mounted flowmeter) |
| Temperature Stability at 750 °C | ±3 °C |
| Heating Rate | 8 °C/min (≤500 °C), 6 °C/min (500–750 °C) |
| Compliance | ASTM D3174 |
| Gas Inlet Ports | 1 × 0.95 cm thermocouple port, 1 × 0.635 cm or 0.876 cm soft-hose barb for inert gas supply |
| Control Options | B1 (single-setpoint), C1 (8-segment single program), D1 (16-segment × 4 programs, RS232 interface) |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Model | FB1300 / FB1400 |
| Temperature Range | 100–1100 °C |
| Chamber Volume | 1.3 L / 2.1 L |
| Insulation | Ceramic Fiber |
| Heating Element Layout | Top + Dual Side Mounting |
| Door Operation | Downward-Opening Hinged Door |
| Safety Interlock | Integrated Door-Activated Power Cut-off |
| Thermocouple Fault Protection | Automatic Heater Disengagement |
| Rear Port | 0.95 cm Diameter for External Sensor Integration |
| Control System | Digital Single-Setpoint Controller with Dual-Mode Display (Actual/Setpoint Temperature) |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Type | Tube Furnace |
| Temperature Range | 1100°C to 1700°C |
| Heating Zone Lengths | 304.8 mm, 609.6 mm, or 914.4 mm |
| Configuration | Single-Zone or Triple-Zone |
| Controller | Integrated or External Microprocessor-Based Programmable Controller |
| Orientation | Horizontal or Vertical |
| Compliance | Designed for ASTM E1142, ISO/IEC 17025-compliant laboratory environments |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer | Lindberg/Blue M |
| Model | BF517xxC / BF518xxC Series |
| Chamber Volume | 1.99 L, 5.3 L, 18.4 L, or 42.5 L |
| Max Operating Temperature | 1100°C |
| Control Options | Digital Single-Setpoint or Multi-Step Programmable Controller |
| Power Supply | 208–240 V, 50/60 Hz |
| Heating Power | 1.8 kW (1.99–5.3 L), 3.5 kW (18.4 L), or 5.6 kW (42.5 L) |
| External Cooling Surface Temp | <60°C at 1100°C operation |
| Safety Features | Door-Interlocked Power Cut-off, Adjustable Over-Temperature Protection, K-Type Thermocouple |
| Gas Ports | 1" Top Exhaust + 3/8" Rear Inlet |
| Construction | Dual-Wall Insulated Steel Housing with Embedded Heating Elements |
| Compliance | Designed for GLP/GMP environments |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Circulating Water Bath |
| Models | TSCIR19 / TSCIR35 / TSCIR89 |
| Bath Capacity | 19 L / 35 L / 89 L |
| Temperature Range | +5 °C to 100 °C |
| Temperature Stability | ±0.1 °C (±0.05 °C at 70 °C) |
| Circulation Type | Internal Recirculation |
| Control System | Microprocessor-Based PID Controller |
| Display | Icon-Driven Graphical LCD |
| Safety Features | Low-Level Fluid Detection, Audible Alarm, Over-Temperature Protection |
| Construction | Stainless Steel Bath Chamber with Removable Perforated Lid and Diffuser Tray |
| Power Rating | 1200 W (TSCIR19), 1500 W (TSCIR35 & TSCIR89) |
| Working Chamber Dimensions (L × W × H) | 305 × 387 × 192 mm (TSCIR19), 305 × 692 × 192 mm (TSCIR35), 483 × 914 × 241 mm (TSCIR89) |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | USA |
| Model | F1600 / F1700 / F1800 |
| Temperature Range | 150–1360 °C |
| Chamber Volume | 5.7–41.4 L |
| Construction | Heavy-duty refractory brick lining + reinforced steel cabinet |
| Heating Element Configuration | Four-wall embedded in refractory cement |
| Standard Floor Protection | Ceramic hearth plate |
| Power Supply | Requires external hardwiring |
| Controller | Sold separately |
| Safety Design | Top-hinged door with heat-shielded orientation (hot surface directed away from operator) |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | USA |
| Model | F30400 |
| Temperature Range | 100–1093 °C (up to 1200 °C short-term) |
| Chamber Volume | 45 L |
| Heating Element Layout | Top, Bottom, Left & Right Walls |
| Safety | 35 A Circuit Breaker + Interlocked Door Switch |
| Control Options | B1 (Single-Setpoint), C1 (8-Step Single Program), D1 (16-Step × 4 Programs, RS232) |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | USA |
| Model | F31700 |
| Temperature Range | 150–1093 °C |
| Chamber Volume | 254.4 L |
| Maximum Sample Load | 227 kg |
| Heating Rate (no load) | 0–870 °C in ≤120 min |
| Door Opening Mechanism | Gas Spring-Assisted Upward-Lifting |
| Safety Interlock | Automatic Power Cut-off Upon Door Opening |
| Heating Element Embedment | Refractory Cement |
| Floor Lining | Silicon Carbide Hearth |
| Base Support | Refractory Brick Bed |
| Structural Frame | Welded Steel Stand (Standard) |
| Controller | External (Not Included) |
| Electrical Connection | Required External Wiring |