Constant Temp/Heating/Drying Equipment
Filter
Showing 841–870 of 886 results
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | USA |
| Model | F47900 (2 L) / F48000 (5.8 L) |
| Temperature Range | 100–1200 °C |
| Chamber Volume | 2 L or 5.8 L |
| Heating Element Layout | Dual-side mounted |
| Max. Operating Temperature | 1200 °C |
| Rear Port Diameter | 9.5 mm |
| Control Options | A1 (single-setpoint), B1 (delayed ramp), C1 (8-segment single program), D1 (16-segment × 4 programs, RS232 interface) |
| Venting | Integrated exhaust port |
| Construction | Heat-treated ceramic chamber lining |
| Compliance | Designed for GLP-compliant thermal processing in analytical and materials laboratories |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | USA |
| Model | F6000 |
| Temperature Range | 100–1200 °C |
| Chamber Volume | 15 L |
| Heating Element Layout | Top, Bottom, Left & Right Walls |
| Standard Exhaust Port | 0.95 cm Diameter |
| Door Safety Interlock | Yes |
| Thermocouple Fault Protection | Yes |
| Control Options | A1 (Single Setpoint), B1 (Setpoint + Ramp Delay), C1 (8-Step Single Program), D1 (4 × 16-Step Programs with RS232) |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | USA |
| Model | FD1500 |
| Temperature Range | 100–1200 °C |
| Chamber Volume | 2.2 L |
| Heating Elements | 4 independent embedded in refractory cement |
| Safety Features | Door-activated power cutoff, dual overtemperature protection (mechanical relay + thermocouple fault detection), adjustable audible alarm |
| Interface Options | B1 (single-setpoint digital controller with ramp delay) or C1 (8-segment programmable digital controller) |
| Rear Port | 0.95 cm diameter for external temperature monitoring |
| Construction | Refractory brick-lined chamber with firebrick door seal |
| Power Cord | Included |
| Compliance | Designed for GLP-compliant weight loss and ashing workflows per ASTM E1868, ISO 1171, and USP <281> |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | USA |
| Model Variants | BF51731, BF51732, BF51841, BF51842 |
| Max Temperature | 1200°C |
| Temperature Uniformity | ±2°C @ 1200°C |
| Control Accuracy | ±0.3% of setpoint |
| Max Power | 4500 W |
| Ramp Time to 1200°C | 20 min |
| Heating Method | Calibrated tubular heating elements |
| Internal Dimensions (H×D×W) | 177.8 × 279.4 × 330.2 mm (BF517xx) / 381 × 381 × 381 mm (BF518xx) |
| External Dimensions (H×D×W) | 685.8 × 584.2 × 609.6 mm (BF517xx) / 838.2 × 711.2 × 736.6 mm (BF518xx) |
| Voltage/Frequency | 208–240 V, 50/60 Hz |
| Net Weight | 75 kg (BF517xx) / 127 kg (BF518xx) |
| Controller Options | Single-setpoint, multi-segment single-program, or multi-segment multi-program digital controllers with optional Over-Temperature Control (OTC), RS485 interface, and inert gas flow meter (FM) integration |
| Safety Features | Door-interlocked power cutoff, Platinel II R thermocouple, top 25.4-mm exhaust port, rear 9.5-mm inlet port |
| Insulation | Moldatherm® high-density ceramic fiber board with embedded LGO (Low-Glow Oxide) heating elements |
| Construction | Dual-wall steel housing with air-gap thermal barrier |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | USA |
| Model | OGH180-S |
| Instrument Type | Precision Drying Oven |
| Temperature Range | 50–330 °C |
| Temperature Uniformity (at 150 °C) | ±2.9 °C |
| Temperature Accuracy (at 150 °C) | ±0.3 °C |
| Chamber Volume | 168 L |
| Internal Dimensions (W×H×D) | 438 × 680 × 564 mm |
| External Dimensions (W×H×D) | 640 × 920 × 738 mm |
| Chamber Material | Stainless Steel 1.4016 (AISI 430) |
| Heating Method | Natural Convection |
| Standard Shelves | 2 (max. 19) |
| Max. Load per Shelf | 25 kg |
| Rated Voltage/Frequency | 230 V / 50 Hz |
| Power Rating | 3100 W |
| Weight | 69 kg |
| Footprint Area | 0.47 m² |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | USA |
| Model | OGS180 |
| Instrument Type | Precision General-Purpose Oven |
| Temperature Range | 50–250 °C |
| Temperature Uniformity (at 150 °C) | ±4 °C |
| Temperature Stability (at 150 °C) | ±0.4 °C |
| Chamber Dimensions (W×H×D) | 438×680×589 mm |
| External Dimensions (W×H×D) | 640×920×738 mm |
| Chamber Volume | 176 L |
| Chamber Material | Stainless Steel 1.4016 (EN 10088-1) |
| Heating Method | Natural Convection |
| Floor Area | 0.47 m² |
| Standard Shelves | 2 (max. 19) |
| Max. Shelf Load | 25 kg |
| Power Supply | 230 V / 50 Hz |
| Rated Power | 3100 W (13.5 A) |
| Net Weight | 66 kg |
| Interface | RS232 serial port |
| Display | Vacuum Fluorescent Display (VFD) |
| Timer Function | On/Off programmable |
| Door Opening Angle | 180° |
| Over-Temperature Protection | Automatic cut-off with audible alarm |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | USA |
| Model | OGS60 |
| Instrument Type | Precision Drying Oven |
| Temperature Range | 50–250 °C |
| Temperature Uniformity (at 150 °C) | ±4 °C |
| Temperature Stability (at 150 °C) | ±0.4 °C |
| Chamber Dimensions (W×H×D) | 328×480×415 mm |
| External Dimensions (W×H×D) | 530×720×565 mm |
| Chamber Volume | 65 L |
| Chamber Material | Stainless Steel 1.4016 (EN 10088-1) |
| Heating Method | Natural Convection |
| Shelf Capacity | 2 standard / up to 13 shelves |
| Max. Load per Shelf | 25 kg |
| Power Supply | 230 V / 50 Hz |
| Rated Power | 1800 W |
| Weight | 42 kg |
| Interface | RS232 standard |
| Brand | Top Instrument |
|---|---|
| Model | HW-3A |
| Type | Benchtop Infrared Drying Oven |
| Temperature Range | 70–150 °C |
| Temperature Uniformity | ±0.5 °C |
| Internal Chamber Dimensions | 206 mm × 200 mm × 294 mm (L×W×H) |
| External Dimensions | 235 mm × 260 mm × 445 mm (L×W×H) |
| Rated Voltage/Frequency | AC 220 V, 50 Hz |
| Total Rated Power | 600 W (Infrared Heater: 250 W |
| Convection Heater | 350 W) |
| Net Weight | 3.5 kg |
| Gross Weight | 4.0 kg |
| Timer Range | 0–15 min (adjustable in 1-min increments) |
| Heating Modes | Dual-mode (infrared irradiation + resistive convection) |
| Safety Compliance | CE-marked design principles |
| conforms to IEC 61010-1 | 2010 for laboratory electrical equipment |
| Vacuum Range | 0–0.1 MPa |
|---|---|
| Temperature Range | 30–150 °C (adjustable in 1 °C increments) |
| Temperature Uniformity | ±2 °C across working chamber |
| Input Voltage | AC 220 V ±10%, 50 Hz |
| Power Consumption | 300 W |
| Integrated Vacuum Pump Socket Rating | ≤220 V, 5 A |
| External Dimensions | 350 × 350 × 240 mm (L×W×H) |
| Manufacturer | Top Instrument (Tianjin, China) |
| Origin | China |
| Type | Benchtop Vacuum Drying Oven |
| Brand | Torrey Pines |
|---|---|
| Origin | USA |
| Model | IC/SC |
| Temperature Range | −20 to 100°C |
| Temperature Accuracy | ±0.5°C |
| Heating/Cooling Time (to 37°C from 25°C) | ≤3 min |
| Dimensions (W×D×H) | 18 × 13 × 26 cm |
| Net Weight | 5 kg |
| Compliance | UL, CSA, CE |
| Interface | RS232 |
| Calibration | Electronic, User-Adjustable |
| Timer Function | Up to 30 days |
| Alarm | Visual and Audible |
| Brand | Totech |
|---|---|
| Origin | Japan |
| Model | SDA-800S / SDA-400S / SDA-200S / SDA-050S / SDA-070S |
| Humidity Control | 3% RH or 20% RH |
| Construction | Aluminum Frame + Acrylic Body |
| Shelf Material | Stainless Steel (ESD-Safe) |
| Optional | Digital Humidity Display Panel |
| Application | Laboratory & Academic Research Environments |
| Compliance | Designed for ISO/IEC 17025-aligned storage conditions |
| Brand | Totech |
|---|---|
| Origin | Japan |
| Model | SD-02 Series (e.g., SD-1106-02, SD-1104-02, SD-702-02, SD-502-02, SD-302-02, SD-252-02, SD-151-02) |
| Minimum Relative Humidity | <2% RH |
| Dew Point | −28°C (for SD-1106-02) |
| Operating Environment | 23°C, 50% RH |
| Compliance | Designed for ISO/IEC 17025-compliant storage environments, compatible with JEDEC J-STD-033 moisture sensitivity level (MSL) handling protocols |
| Brand | Tousimis |
|---|---|
| Origin | USA |
| Model | 931 Series |
| Temperature Range | −40 °C to +60 °C |
| Pressure Range | 0–2000 psi |
| Display | LCD Touchscreen Interface |
| Sample Chamber Diameters | 31.75 mm, 63.50 mm, 86.36 mm (all × 31.75 mm depth) |
| Power Supply | 120 V, 50–60 Hz (optional voltages available) |
| Compliance | UL, CE, U.S. Military Standards |
| Filtration | Integrated 0.5 µm particulate filter (internal and external purge path) |
| Cooling | Closed-loop internal refrigeration system |
| Software | Stasis™ automated drying protocol engine |
| Brand | Tousimis |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | AutoSamdri-934, Series C |
| Pressure Range | 0–2000 psi |
| Temperature Range | −30 °C to 60 °C |
| Brand | Tousimis |
|---|---|
| Origin | USA |
| Model | SAMDRI-795 |
| Chamber ID | 1.25" |
| Temperature Range | −30 °C to 60 °C |
| Pressure Range | 0–2,000 psi |
| Control Mode | Semi-Automatic with Integrated Temperature/Pressure Regulation |
| Cooling Time | ~1 min (from ambient) |
| Brand | Tousimis |
|---|---|
| Origin | USA |
| Model | SAMDRI-PVT-3D |
| Chamber ID | 1.25" |
| Temp Range | -30 °C to 60 °C |
| Pressure Range | 0–2,000 psi |
| Control | Fully Automated Temperature & Pressure Regulation |
| Flow Control | Micrometer-Adjustable Needle Valve |
| Cooling Time | ~1 min (from ambient) |
| Chamber Access | Top-Loading with View Window |
| Internal Surface | CO₂- and High-Purity Ethanol-Compatible Materials |
| Filtration | Integrated Particulate Filter |
| Optional | Condenser for Ethanol Recovery & Noise Reduction |
| Brand | TRILOS |
|---|---|
| Model | HC250 |
| Origin | USA |
| Instrument Type | Circulating Bath |
| Temperature Range | −10 °C to +90 °C |
| Heating Power | 600 W |
| Cooling Capacity | 250 W @ 20 °C ambient / 20 °C bath setpoint |
| Pump Flow Rate (Max) | 8 L/min |
| Voltage/Frequency | 220 V~, 50 Hz |
| Rated Current | 10 A |
| IP Rating | IP20 |
| Refrigerant | R404A |
| Dimensions (W×D×H) | 250 mm × 480 mm × 535 mm |
| Circulation Mode | Internal & External |
| Brand | WIGGENS |
|---|---|
| Origin | Germany |
| Model | WA8 |
| Bath Volume | 3–8 L |
| Temperature Range | Ambient +5 to 99.9 °C |
| Temperature Stability | ±0.2 °C |
| Temperature Resolution | 0.1 °C |
| Heating Power | 2.0 kW |
| Circulation Type | Internal & External |
| Control Mode | Heating-Only |
| Ingress Protection | IP52 (Control Panel), IP43 (Unit) |
| Construction | Mirror-Finish Stainless Steel Interior, Corrosion-Resistant Coated Exterior |
| Safety Features | Low-Level Liquid Alarm, Over-Temperature Cut-Off at 105 °C, Waterproof Sealed Keypad |
| Brand | WIGGENS |
|---|---|
| Origin | Germany |
| Model | WB-350S |
| Temperature Range | Ambient +5 to 130 °C |
| Accuracy | ±0.1 °C (at setpoint) |
| Temperature Uniformity (at 80 °C) | ±0.1 °C (stability), ±0.5 °C (gradient across block) |
| Control System | PID feedback with overshoot suppression |
| Display | VFD (dual-channel: setpoint & real-time temperature) |
| Timer Modes | Two independent modes — delay start or dwell time after reaching setpoint |
| Safety Features | Dual thermal cutoffs (heating plate >150 °C, PCB overtemperature), current limiting, auto power-off, visual high-temp warning (red LED) |
| External Dimensions (W×D×H) | 276 × 334 × 120 mm |
| Internal Chamber (W×D×H) | 154 × 99 × 37 mm |
| Net Weight | 3.9 kg |
| Power Supply | 230 V, 50/60 Hz, 2.8 A |
| Operating Environment | 2–60 °C, ≤80% RH (non-condensing) |
| Standard Accessories | Main unit, protective lid |
| Heating blocks | Optional, application-specific |
| Brand | WIGGENS |
|---|---|
| Origin | Germany |
| Model | WD310 |
| Temperature Range | 40–150 °C (with PT100) / 50–150 °C (without PT100) |
| Resolution | ±0.1 °C |
| Accuracy | ±0.1 °C |
| Overheat Cut-off | 170 °C |
| Timer Setting | 1–9959 min or OFF |
| Display | 4-digit LED |
| Heating Block Dimensions | 79 × 104 × 50 mm |
| Unit Dimensions (W × L × H) | 200 × 270 × 80 mm |
| Interface | RS232 |
| Safety | Dual thermal cut-off protection |
| Operating Modes | OFF, OFF-TIME, WAIT-TIME |
| Brand | WIGGENS |
|---|---|
| Origin | Germany |
| Model | WD325 |
| Temperature Range | 60–200 °C (with dedicated 150 °C COD program) |
| Accuracy | ±2 °C at 150 °C |
| Timer Range | 1–1999 min |
| Heating Block Capacity | 25 × Ø16.5 × 55 mm tubes |
| Display | 4-digit LED |
| Safety Features | Visual over-70 °C warning light, automatic shutdown at >240 °C |
| Memory | 3 programmable heating protocols |
| Power Supply | 220 V, 50 Hz |
| Dimensions (W×H×D) | 189 × 116 × 315 mm |
| Weight | 4.5 kg |
| Standard Configuration | Main unit + aluminum block with 25 tube wells |
| Brand | WIGGENS |
|---|---|
| Origin | Germany |
| Model | WH-410D |
| Display | LED |
| Speed Range | 150–1500 rpm |
| Number of Stirring Positions | 4 |
| Max. Volume per Position | 2000 mL |
| Stirring Plate Dimensions (W×L) | 313 × 303 mm |
| Overall Dimensions (W×L×H) | 344 × 377 × 48 mm |
| Housing Material | Powder-Coated Stainless Steel |
| Drive Type | Brushless DC Motor |
| Control Method | Analog Knob with Real-Time Digital Feedback |
| Power Regulation | Viscosity-Compensated Output |
| Compliance | CE, RoHS, IEC 61010-1 |
| Brand | WIGGENS |
|---|---|
| Origin | Germany |
| Model | WH200D-1K |
| Temperature Range | 50–300 °C |
| Control Accuracy (PID) | ±1 °C |
| Plate Material | Anodized Aluminum with Ceramic Coating |
| Plate Dimensions | 170 × 170 mm |
| Power Rating | 680 W |
| Temp Uniformity | ±1 °C |
| External Sensor Support | Pt100 |
| Safety Features | Over-Temp Alarm, >60 °C Status LED, Factory Reset, OFF/OFF-Time/WAIT-Time Scheduling (1–9959 min) |
| Brand | Yacheng / PILOTECH |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | YC-015 |
| Maximum Feed Rate | 1500 mL/h |
| Particle Size Range | 1–25 µm |
| Inlet Air Temperature Range | Up to 250 °C |
| Drying Residence Time | 1.0–1.5 s |
| Temperature Control Accuracy | ±1 °C (PID-controlled) |
| Noise Level | <60 dB(A) |
| Standard Nozzle Orifice | 1.0 mm (optional: 0.5/0.8/1.5/2.0 mm) |
| Construction Material | 316 Stainless Steel + Borosilicate Glass |
| Power Supply | 3.5 kW, 220 V, Single-phase |
| Brand | YaCheng / PILOTECH |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | YC-1800 |
| Price | Upon Request |
| Max Feed Rate | 1800 mL/h |
| Minimum Sample Volume | 50 mL |
| Drying Inlet Temperature Range | 110–150 °C |
| Temperature Control Accuracy | ±1 °C (PID) |
| Nozzle Orifice Options | 0.5, 0.7, 1.0, 1.5, 2.0 mm |
| Power Supply | 4 kW / 380 V AC |
| Construction | Full 316L Stainless Steel |
| Atomization | Dual-Fluid Pneumatic Nozzle |
| Noise Level | <65 dB(A) |
| Particle Flowability | High (Narrow Normal Size Distribution) |
| Brand | YaCheng / PILOTECH |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | OEM Manufacturer |
| Country of Origin | China |
| Model | YC-510 |
| Sample Type | Aqueous solutions only |
| Max Feed Rate | 500 mL/h |
| Inlet Air Temperature Range | 50–200 °C (vacuum-enabled low-temp mode: ≤55 °C) |
| Particle Size Distribution | 1–25 µm |
| Vacuum Level | −0.08 MPa |
| Temperature Control Accuracy | ±1 °C (PID-regulated) |
| Nozzle Orifice | Standard 1.0 mm (optional: 0.5/0.8/1.5/2.0 mm) |
| Minimum Sample Volume | 10–20 mL (dependent on solids content) |
| Final Moisture Content | <1% w/w |
| Construction | Full 316L stainless steel |
| Power Rating | 3.5 kW |
| Display | Color LCD touchscreen with Chinese UI (factory-default) |
| Brand | YAMATO |
|---|---|
| Origin | Japan |
| Model | DL410 |
| Maximum Water Evaporation Rate | 3000 mL/h |
| Atomization Method | Two-Fluid Nozzle (Orifice Diameter: 0.7 mm) |
| Drying Configuration | Co-Current Downward Spray |
| Inlet Air Temperature Range | 0–300 °C |
| Outlet Air Temperature Monitoring | K-Type Thermocouple |
| Drying Chamber Dimensions | Ø457 mm × H975 mm (Borosilicate Glass) |
| Chamber & Cyclone Material | Ultra-Hard Borosilicate Glass |
| Feed Pump | Precision Peristaltic Type, 0–70 mL/min Adjustable |
| Hot Air Flow Control | DC Brushless Blower, 0.3–1.0 m³/min |
| Heating System | Dual Stainless Steel Heaters, 2.0 kW × 2 |
| Nozzle Maintenance | Automated Pulse Cleaning (Probe Tapping + Purge Air) |
| Safety Features | Independent Over-Temperature Cut-Off, Leakage Current Protection, Feed Pump Reverse Rotation Detection, Electrostatic Discharge Brush, Integrated Safety Enclosure |
| Power Supply | AC 220 V, 50/60 Hz, 24 A |
| Dimensions (W×D×H) | 1060 × 880 × 1770 mm |
| Weight | ~180 kg |
| Brand | YAMATO |
|---|---|
| Origin | Japan |
| Model | GB210-A |
| Input Voltage Range | AC 200–240 V (50/60 Hz) |
| Inlet Air Temperature Range | 40–220 °C (±1 °C PID control) |
| Outlet Air Temperature Range | 0–60 °C |
| Drying Air Flow | 0–0.7 m³/min |
| Atomizing Air Pressure | 0–0.6 MPa |
| Feed Pump Flow Rate | 0–26 mL/min |
| Power Consumption | 2.0–2.88 kW |
| Dimensions (W×D×H) | 760 × 420 × 1350 mm |
| Weight | 110 kg |
| Brand | Yarong |
|---|---|
| Origin | Shanghai, China |
| Model | B-220 |
| Temperature Range | Room Temp + 5°C to 100°C |
| Temperature Stability | ±0.5°C |
| Bath Capacity | 22 L |
| Heating Power | 1000 W |
| External Dimensions (W×D×H) | 570 × 330 × 220 mm |
| Voltage/Frequency | 220 V / 50 Hz |
| Net Weight | 3.6 kg |
| Inner Bath Dimensions | 220 × 115 × 180 mm (L×W×H) |
| Heating Element | Fully Submerged Annular Stainless Steel Heater with PTFE-Coated Interior |
| Brand | Yarong |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | B-260 |
| Quotation | Upon Request |
| Temperature Range | Ambient to 99 °C |
| Temperature Control Accuracy | ±1 °C |
| Bath Chamber Dimensions | 26 cm × 15 cm (L × W) |
| Heating Power | 1.0 kW |
| External Dimensions (W × D × H) | 36 cm × 29 cm × 23 cm |
| Voltage/Frequency | 220 V / 50 Hz |
| Net Weight | 5.5 kg |
