| Brand | AGC |
|---|---|
| Origin | Ireland |
| Model | MAP-PAK Combi |
| Measurement Range | 0.1–100% O₂ and CO₂ |
| Accuracy | ±1% of reading |
| Response Time | <10 s |
| Data Storage Capacity | Up to 5,000 records |
| Display | Backlit LCD |
| Power | Rechargeable battery (4 units) + AC adapter |
| Compliance | CE-marked, ISO 9001-manufactured instrumentation |
| Software | MP Download Software (Windows-compatible) |
| Optional Accessory | Portable thermal printer |
| Language Support | Multilingual UI (English, French, German, Spanish, Italian, Chinese) |
| Brand | MOCON (Dansensor) |
|---|---|
| Model | CheckMate 4 SV |
| Origin | Denmark |
| Gas Measurement | O₂ or O₂ + CO₂ |
| Principle | Zirconia (O₂), Electrochemical (O₂), Dual-Beam Infrared (CO₂), Optical Fluorescence (O₂) |
| Sampling Method | Non-invasive optical probe or minimally invasive needle-penetration |
| Minimum Sample Volume | None |
| Resolution | 0.001% |
| Accuracy | ±0.02% |
| Compliance | Designed for ISO 8573-1, ASTM F2714, USP <1207>, FDA 21 CFR Part 11–ready software architecture |
| User Interface | Multi-language capacitive touchscreen (10 languages) |
| Data Management | On-device storage with timestamped audit trail, optional PC-based Dansensor Insight™ software for multi-line monitoring and GLP/GMP-compliant reporting |
| Brand | MOCON (Dansensor) |
|---|---|
| Model | CheckPoint 4 |
| Origin | Denmark |
| Detection Gases | O₂ and CO₂ (selectable single or dual) |
| Measurement Principle | Electrochemical (O₂), Infrared (CO₂) |
| Portability | Handheld, battery-powered |
| Interface | Capacitive touchscreen with 10 language options |
| Compliance | Designed for ISO 22000, HACCP, and GMP-aligned quality control environments |
| Power | Rechargeable Li-ion battery with rugged charging port |
| Accessories | Standard low-cost hypodermic needle probe (22G), optional protective boot |
| Auto-shutdown | Yes, energy-saving mode |
| Gas flow alarm | Visual and audible alert |
| Certifications | CE, RoHS, FDA-compliant design (non-invasive testing per 21 CFR Part 11 data integrity guidelines) |
| Brand | MOCON |
|---|---|
| Origin | Denmark |
| Model | Lippke 5000 |
| Test Pressure Range | 10–5000 mbar |
| Resolution | 0.1 mbar (0–1000 mbar), 1 mbar (1000–5000 mbar) |
| Accuracy | ±0.5 mbar or ±1% of reading (whichever is greater) |
| Test Volume Capacity | 0–90,000 mL |
| Test Duration | 1–500 s |
| Data Storage | >1,000,000 records |
| Interface | USB 2.0 (Host & Device), RJ-45 Ethernet |
| Compliance | ASTM F1140, F2054, F2095, F2096 |
| Brand | Labthink |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | C650H Headspace |
| Price Range | USD 1,400 – 7,000 |
| O₂ Measurement Range | 0.2–21% (v/v) |
| O₂ Accuracy | ±0.2% (v/v) |
| CO₂ Measurement Range (optional) | 2–100% (v/v) |
| CO₂ Accuracy (optional) | ±2% (v/v) |
| Sample Volume Required | ≥5 mL (O₂), ≥20 mL (CO₂) |
| Dimensions | 350 × 330 × 200 mm (L×W×H) |
| Weight | 5.5 kg |
| Power Supply | 220 VAC 50 Hz / 120 VAC 60 Hz |
| Interface | RS232 |
| Display | LCD with bilingual (EN/CN) menu interface |
| Data Storage | Internal memory |
| Printer | Integrated thermal micro-printer |
| Brand | MOCON / Dansensor |
|---|---|
| Origin | Denmark |
| Model | CheckMate 4 |
| Measurement Gases | O₂ only or O₂ + CO₂ dual-sensor configuration |
| Detection Principle | Electrochemical (O₂) and Infrared (CO₂) |
| Sample Volume Required | < 2 mL |
| Data Storage Capacity | Up to 1,000,000 test records |
| User Profiles | Configurable individual logins with role-based access |
| Interface | 7-inch capacitive multi-touch LCD (English, Spanish, French, German, Chinese, Portuguese, Russian) |
| Connectivity | Ethernet (LAN), USB 2.0 (for barcode scanner, keyboard, printer, or data export via USB drive) |
| Sensor Module Design | Field-replaceable, pre-calibrated modular sensors |
| Compliance | Designed to support GLP/GMP environments |
| Calibration | Factory-calibrated |
| Brand | Mocon |
|---|---|
| Origin | Denmark |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Dansensor ISM-3 |
| Measurement Range | 1 ppm – 100 % O₂ (std. 0–20.9 %) |
| Accuracy | ±1% of reading |
| Sensor Type | Ceramic Solid-State Electrochemical |
| Response Time | <60 s (t₉₀) |
| Flow Rate | 125 mL/min |
| Warm-up Time | 10 min (operational), 20 min (full stabilization) |
| Calibration Interval | 12 months |
| Output Signal | 4–20 mA (standard), optional 0–10 V |
| Alarm Outputs | 2 programmable O₂ alarms + system fault alarm (max. 48 V, 1 A, SPST configurable) |
| Power Supply | 230 VAC ±10% / 115 VAC ±10%, 50–60 Hz |
| Enclosure Material | Stainless steel (IP65-rated housing) |
| Dimensions (H×W×D) | 125 × 185 × 125 mm (ISM-3i), 125 × 185 × 160 mm (ISM-3x w/ integrated display) |
| Weight | 3.7 kg (ISM-3i), 3.8 kg (ISM-3x) |
| Brand | Mocon |
|---|---|
| Model | Dansensor LeakMatic II |
| Origin | Denmark |
| Type | Online Non-Destructive CO₂-Based Leak Detection System for Modified Atmosphere Packaging (MAP) |
| Max. Test Speed | 4 cartons/min |
| Max. Package Dimensions (with fill) | 330 × 610 × 300 mm (L×W×H) |
| Sensor Type | Optical CO₂ Sensor |
| Test Pressure Range | Down to 300 mbar absolute |
| Warm-up Time | 1 min (cold start), 20 sec (from standby) |
| Number of Programmable Test Methods | 16 |
| Interface | Dual RS232 ports, Relay outputs (≤48 V/1 A) |
| Power Supply | 400 VAC |
| Weight | ~450 kg |
| Brand | MOCON |
|---|---|
| Origin | Denmark |
| Model | LeakPointer 3 |
| Detection Limit | 50 µm |
| Test Cycle Time | 10 s per package |
| Max. Chamber Vacuum | –750 mbar |
| CO₂ Sensor Type | NDIR |
| Operating Temperature | +5 °C to +35 °C |
| Power Supply | 100–260 VAC, 50/60 Hz |
| Dimensions (open lid) | 617 mm H × 543 mm W × 400 mm D |
| Weight | 20 kg |
| Data Storage Capacity | >1,000,000 test records |
| Compliance | CE-marked |
| Recommended CO₂ Ambient Level | <1500 ppm |
| Calibration Interval | Every 12 months |
| Brand | Mocon |
|---|---|
| Origin | Denmark |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Dansensor MAP Check 3 |
| Price Range | USD 6,800 – 13,600 |
| Oxygen Sensor Type | Electrochemical, Range: 0–100% O₂, Accuracy: ±0.01% abs (≤1% O₂), ±1% rel (>1% O₂) |
| CO₂ Sensor Type | Heated Dual-Beam NDIR, Range: 0–100% CO₂, Accuracy: ±0.5% abs, ±1.5% rel |
| Warm-up Time | 10 min (O₂), 8 min (CO₂) |
| Gas Flow Rate | 6–500 L/min |
| Inlet Pressure | 2–10 bar |
| Pressure Drop | 1 bar @ 10 bar inlet |
| Communication Interfaces | 2× RS232C, LAN 10/100 Mbit (Modbus TCP), USB, 4–20 mA / 0–10 V analog outputs, 24 VDC logic I/O |
| Power Supply | 103–132 / 207–264 VAC, auto-ranging, 47–63 Hz |
| Dimensions (H×W×D) | 192 × 230 × 375 mm |
| Weight | 8.5–11.5 kg |
| Enclosure Rating (optional) | IP45 (NEMA 3S) |
| Compliance | CE-marked, RoHS-compliant |
| Brand | Mocon |
|---|---|
| Origin | Denmark |
| Model | MAP Mix 9001 ME |
| Gas Channels | 2 or 3 |
| Flow Range | 20–400 L/min (40–850 SCFH) |
| Max Output Pressure | 6 bar |
| Input Pressure Range | 5.5–10 bar (varies by configuration) |
| Accuracy | ±2% (at 15–100% flow, 10–90% blend ratio) |
| Housing Material | Stainless Steel |
| Compliance | CE-marked |
| Dimensions (D×H×W) | 420 × 194 × 235 mm |
| Weight | 10–12 kg |
| Brand | Mocon |
|---|---|
| Origin | Denmark |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | MAP Mix Provectus |
| Price Range | USD 13,500 – 27,000 |
| Gas Types Supported | O₂, N₂, CO₂, Air, Ar (optional) |
| Mixing Configurations | 2-gas or 3-gas |
| Max Total Output Flow | 1500 L/min (3-gas mode) |
| Flow Accuracy | ±2% at ≥50 L/min |
| Input Pressure Range | 2–10 bar |
| Pressure Drop | ≤1 bar at 10 bar inlet |
| Flow Control Range per Gas | 6–500 L/min |
| Operating Temperature | 0–50 °C |
| Display | Touchscreen LCD |
| Connectivity | RS232 ×2, Ethernet (10/100 Mbit, Modbus TCP), USB, 24 VDC I/O |
| Power Supply | 103–132 / 207–264 VAC, 47–63 Hz or 24 VDC |
| Dimensions (H×W×D) | 192 × 230 × 375 mm |
| Weight | 12.0–14.0 kg |
| IP Rating (with optional kit) | IP45 (NEMA 3S) |
| Compliance | CE-marked |
| Predefined Programs | Up to 10 standard gas mixtures |
| Data Logging | Timestamped flow, pressure, mixture ratio, runtime, total consumption |
| Integration | Fully compatible with Dansensor MAP Check 3 gas analyzers |
| Brand | MOCON |
|---|---|
| Origin | Denmark |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | MultiCheck 2 |
| Price Range | USD 13,500 – 27,000 |
| Brand | Mocon |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Optech-O2 P |
| Power Supply | USB-powered (2.5 W) |
| Operating Temperature | 5–40 °C (Headspace Mode), 10–35 °C (Dissolved O₂ Mode) |
| Measurement Principle | Fluorescence-based Confocal Optical Sensing |
| Detection Range (Headspace) | 0.050%–25% O₂ (500 ppm–250,000 ppm) |
| Detection Range (ImPULSE™ Adhesive Sensor) | 0.001%–25% O₂ (10 ppm–250,000 ppm) |
| Repeatability (Needle Probe, 0–150 mmHg) | ±0.100% O₂ or ±5% of reading (whichever is greater) |
| Repeatability (Needle Probe, 150–1000 mmHg) | ±0.015% O₂ or ±2% of reading (whichever is greater) |
| Repeatability (ImPULSE™ Sensor) | ±0.015% O₂ or ±3% of reading (whichever is greater) |
| Probe Dimensions (w/ Needle) | 4.83 × 3.30 × 15.24 cm (H×W×D) |
| Probe Dimensions (w/o Needle) | 4.83 × 3.30 × 22.86 cm (H×W×D) |
| Preheat Time | 20 min |
| Compliance | CE, CSA, UL certified |
| Pressure Compensation | Integrated for needle-based measurements |
| Brand | QKTester |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Origin Category | Domestic (China) |
| Model | OGT-01 |
| Price | USD 145 (FOB) |
| Measured Gases | O₂, CO₂ |
| Measurement Principle | Electrochemical (O₂), Non-Dispersive Infrared (NDIR) Absorption (CO₂) |
| Sample Volume | O₂ < 3 mL |
| Resolution | 0.01% (v/v) |
| Accuracy | ±0.2% (v/v) |
| O₂ Range | 0.2–21.0% (v/v) |
| Standard Sampling Volume | ≥5 mL at 101.3 kPa |
| Dimensions | 350 × 330 × 200 mm (L×W×H) |
| Power Supply | 220 VAC 50 Hz / 120 VAC 60 Hz |
| Net Weight | 5.5 kg |
| Brand | QKTester |
|---|---|
| Model | OGT-01 |
| Origin | Shandong, China |
| Manufacturer | QKTester Instrument Co., Ltd. |
| Gas Measurement | O₂ (standard), CO₂ (optional) |
| Principle | Electrochemical sensor (O₂), NDIR (CO₂, optional) |
| Range | 0–100% O₂ |
| Resolution | 0.01% |
| Accuracy | ±0.2% O₂ |
| Sample Volume | <3 mL |
| Dimensions | 230 × 120 × 82 mm |
| Weight | 1 kg |
| Power | 220 VAC ±10%, 50 Hz / 120 VAC ±10%, 60 Hz |
| Data Storage | 1500 records |
| Display | Backlit LCD, bilingual (English/Chinese) |
| Interface | Built-in thermal printer |
| Compliance | Designed for ISO 8573-1, USP <1207>, ASTM F2476, and GMP-aligned environmental monitoring workflows |
| Brand | QKTester |
|---|---|
| Model | OGT-02 |
| Measurement Principle | Electrochemical (O₂), NDIR Infrared Absorption (CO₂, optional) |
| Gas Types | O₂ (standard), CO₂ (optional) |
| O₂ Range | 0–100% vol, Resolution: 0.01%, Accuracy: ±0.2% |
| CO₂ Range | 2–100% vol, Resolution: 0.01%, Accuracy: ±(0.03% + 5% of reading) |
| Sensor Lifetime | ~2 years (O₂), >15 years (CO₂) |
| Sample Volume | ≥6 mL (O₂), ≥20 mL (CO₂) |
| Power Supply | 220 VAC ±10%, 50 Hz |
| Dimensions | 350 × 310 × 220 mm |
| Weight | 3.2 kg |
| Compliance | Designed for GMP/GLP environments |
| Brand | QuankeRida / qktester |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Region of Origin | Domestic (China) |
| Model | OGT-01 |
| Price | USD 145 (converted from ¥999 at 1:6.9) |
| Measurement Range | 0–21% O₂ (typical) |
| Accuracy | ±0.2% O₂ (full scale) |
| Sample Volume | ≥5 mL (at standard atmospheric pressure) |
| Detection Principle | Fluorescence Quenching or Electrochemical Sensing (user-selectable/configurable per unit) |
| Operation Mode | Manual probe insertion with real-time sensor response |
| Data Storage | Internal non-volatile memory (≥1,000 test records) |
| Power Supply | AC 220 V ±10% or rechargeable Li-ion battery (field-deployable) |
| Dimensions | 350 × 330 × 200 mm (L×W×H) |
| Net Weight | 5.5 kg |
| Brand | ZK Electronics |
|---|---|
| Model | HGT-01H |
| Origin | Shandong, China |
| Manufacturer | Yes |
| Type | Domestic |
| Measured Gases | O₂ (standard), CO₂ (optional) |
| Principle | Electrochemical (O₂), NDIR Infrared Absorption (CO₂) |
| Sample Volume | O₂ ≤ 8 mL, CO₂ ≤ 15 mL (standard mode) |
| Resolution | 0.01% |
| Accuracy | ±0.2% (O₂), ±(0.03% + 5% of reading) (CO₂) |
| Response Time | ≤8 s (O₂), ≤10 s (CO₂) |
| Dimensions | 230 × 120 × 82 mm |
| Weight | 0.7 kg |
| Data Storage | 2000 records |
| Power | AC 220 V, 50 Hz |