Cryogenic Thermostat
Filter
Showing 31–60 of 80 results
| Brand | Orient KOJI |
|---|---|
| Temperature Range | 77 K to 800 K |
| Temperature Stability | ±0.1 K |
| Liquid Nitrogen Capacity | 2 L |
| Hold Time at 78 K | 4 h |
| Compatible Spectrometers | HORIBA FluoroMax, Edinburgh Instruments FLS980/FLS1000, Hitachi F-7000 |
| Origin | Tianjin, China |
| Brand | PHYSIKE |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic (China-Made) |
| Model | CryoAce-50 |
| Quotation | Upon Request |
| Vibration Stability | 10 nm |
| Circulating Medium | Helium Gas |
| Brand | CryoAll |
|---|---|
| Model | TM-P/H |
| Measurement Principle | Resistance-based cryogenic thermometry (RhFe, Diode, Pt100) |
| Temperature Range | 1.1 K to 493 K (−272.05 °C to +219.85 °C) |
| Accuracy | ±10 mK (typical, calibrated against ITS-90 traceable standards) |
| Input Channels | 1 or 6 independent sensor inputs |
| Interface Options | RS-485 (Modbus RTU), USB 2.0 (CDC/VCP), 10/100BASE-T Ethernet (TCP/IP, DHCP/Static IP), 4–20 mA analog output (isolated, loop-powered) |
| Form Factor | Benchtop (150 × 96 × 40 mm) and Handheld (85 × 50 × 20 mm, 60 g) |
| Power Supply | 5 V DC (USB) or 9–36 V DC (terminal block, reverse-polarity protected) |
| Compliance | CE, RoHS, IEC 61326-1 (EMC for laboratory environments) |
| Brand | Herrytech |
|---|---|
| Origin | Shanghai, China |
| Model | YQ-4006 |
| Instrument Type | Vertical |
| Temperature Range | −40 °C to 100 °C |
| Temperature Stability | ±0.1 °C |
| Bath Opening | 180 mm × 140 mm |
| Internal Bath Volume | 6 L |
| Circulation Flow Rate | 12 L/min |
| Refrigeration Capacity | 2300 W (at 20 °C with pure water) |
| Inner Bath Dimensions | 200 mm × 200 mm × 180 mm |
| Control Resolution | 0.1 °C (standard), optional 0.01 °C or 0.001 °C |
| Sensor | PT100 platinum resistance thermometer |
| Refrigerant | Eco-friendly non-CFC/HFC compliant refrigerant |
| Brand | Julabo |
|---|---|
| Origin | Germany |
| Series | F-Series |
| Temperature Range | -10 to +40 °C |
| Stability | ±0.5 °C |
| Refrigeration Power | 0.25 / 0.5 / 1.0 kW |
| Pump Flow Rate | 1.7–9.5 L/min |
| Max. Pressure | 0.35–0.55 bar |
| Reservoir Volume | 1.7–23 L |
| Dimensions (W×L×H) | 24×40×52 cm to 37.5×49×64 cm |
| Compatible Fluids | Water, Water-Glycol Mixtures, Thermal G |
| Brand | JULABO |
|---|---|
| Model | FD200 |
| Origin | Germany |
| Temperature Range | 10 to +30 °C |
| Stability | ±0.2 °C |
| Refrigeration Power | 220 W |
| External Cooling Head Dimensions | 18 × 27 × 39 cm (W × L × H) |
| Weight | 16 kg |
| Connection Type | Flow-through (pumpless, requires external circulation controller) |
| Compliance | CE, RoHS, ISO 9001 certified manufacturing |
| Brand | Julabo |
|---|---|
| Origin | Germany |
| Model Series | FL Series |
| Temperature Range | -20 °C to +40 °C |
| Stability | ±0.5 °C |
| Max Refrigeration Capacity | 20 kW |
| Max Flow Rate | 80 L/min |
| Max Pressure | 6.0 bar |
| Reservoir Volume | up to 80 L |
| Dimensions (W×D×H) | up to 95×115×161 cm |
| Fluid Compatibility | Water, Water/Glycol Mixtures, Thermal G® |
| Max Inlet Fluid Temperature | 80 °C |
| Cooling Method | Air-Cooled (FL) or Water-Cooled (FLW) |
| Brand | JULABO |
|---|---|
| Origin | Germany |
| Model | FT Series |
| Temperature Range | –100 °C to +30 °C |
| Stability (FT402/FT902) | ±0.5 °C / ±1.0 °C |
| Refrigeration Power | 160–450 W |
| Cooling Head Material | Stainless Steel (AISI 316) |
| Temperature Display Resolution | 0.1 °C |
| Cooling Head Dimensions | Ø1.5–5 mm × L=6–65 cm |
| Unit Dimensions (W×L×H) | 18×27×39 cm to 38×55×60 cm |
| Weight | 18–58 kg |
| Brand | Oxford Instruments |
|---|---|
| Origin | United Kingdom |
| Model | Microstat |
| Temperature Range | 1.5 K to 300 K (depending on configuration) |
| Cooling Method | Closed-cycle helium cryocooler or liquid helium flow cryostat |
| Optical Access | Dual windows (UV to FIR transmission, optional AR coatings) |
| Electrical Feedthroughs | Up to 24 low-noise coaxial or twisted-pair leads |
| Footprint | Compact benchtop design (< 300 mm × 300 mm base) |
| Vibration Isolation | Active/passive hybrid stage stabilization |
| Compliance | CE, UKCA, RoHS |
| Brand | Oxford Instruments |
|---|---|
| Origin | United Kingdom |
| Model | MicrostatHiRes |
| Temperature Range | 2.7 K – 500 K (with optional rotary pump) / 3.4 K – 500 K (standard) |
| Base Temperature Stability | ±0.1 K |
| Helium Consumption at 4.2 K | < 0.70 L/hr (with low-loss transfer line) |
| Cool-down Time from RT to 4.2 K | ~15 min (with pre-cooled transfer line) |
| Working Distance | 2.2 mm |
| Sample Vibration | < 20 nm (measured in SEM environment) |
| Mass | 1.5 kg |
| Controller | Mercury iTC |
| Communication Interfaces | RS232, USB (serial emulation), TCP/IP, GPIB |
| Software Integration | LabVIEW driver library and virtual instrument support |
| Compliance | Designed for GLP/GMP-adjacent research environments |
| Brand | Oxford Instruments |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Optistat |
| Price Range | USD 13,500 – 40,500 (FOB UK) |
| Brand | Oxford Instruments |
|---|---|
| Origin | United Kingdom |
| Model | Optistat Dry |
| Temperature Range | < 3 K to 300 K |
| Cool-down Time | ≤120 min to 10 K |
| Optical Aperture | Up to 28 mm diameter |
| Numerical Aperture | f/1 |
| Electrical Feedthroughs | Up to 12 leads |
| Cooling Options | Air-cooled or water-cooled cryocooler |
| Vibration Level | < 10 µm (when mounted on optical table) |
| Compliance | Designed for ISO/IEC 17025-compliant laboratories, compatible with GLP/GMP data integrity requirements |
| Origin | UK |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Optistat Dry |
| Price Range | USD 42,000 – 70,000 |
| Brand | Oxford Instruments |
|---|---|
| Origin | United Kingdom |
| Model | Proteox 5 mK |
| Cooling Principle | Helium-3/Helium-4 Dilution Refrigeration |
| Base Temperature | < 5 mK |
| Magnet Compatibility | Integrated or Standalone Oxford Superconducting Magnets (up to 18 T) |
| Cryogenic Architecture | Dry, Helium-Free Operation |
| System Configuration | Turnkey Cryostat with Vibration-Isolated Mixing Chamber and Thermal Anchoring Stages |
| Brand | Oxford Instruments |
|---|---|
| Origin | United Kingdom |
| Model | Proteox |
| Cooling Principle | Continuous He-3/He-4 Dilution Refrigeration |
| Base Temperature | ≤ 10 mK (typical) |
| Experimental Bore Diameter | 360 mm |
| Secondary Insert Capacity | Up to 2 × ISO100 feedthroughs |
| Additional Feedthroughs | Up to 2 × KF40 + 2 × KF25 |
| Thermal Management | Patented Gas-Gap Heat Switch System |
| Magnet Integration | Fully compatible with Oxford Instruments superconducting magnets |
| Software Platform | Web-based, cross-platform control with audit-trail logging |
| Maintenance Cycle | Extended via automated gas-handling bypass system |
| Sample Exchange | Optional bottom-loading rapid sample transfer mechanism integrated at secondary insert level |
| Compliance | Designed for GLP/GMP-aligned laboratory environments |
| Brand | Oxford Instruments |
|---|---|
| Origin | United Kingdom |
| Model | SpectromagPT |
| Temperature Range | 1.6 K – 300 K |
| Magnetic Field Strength | Up to 7 T |
| Optical Access | Dual-axis (parallel & perpendicular to field) |
| Sample Chamber Diameter | 30 mm |
| Temperature Stability (standard probe) | ±0.1 K |
| Cool-down Time (room temp → 4 K) | ~40 h |
| Probe Cool-down Time (to <2 K, cold insert) | <90 min |
| Field Ramp Time (to max field) | ≤60 min |
| Continuous Operation Duration | >4 weeks |
| Cryocooler Type | Closed-cycle, helium-free |
| Sample Exchange | Top-loading, no lock-in mechanism required |
| Thermal Environment | Static exchange gas cooling (no convective flow) |
| Optional Sample Stage | ±15 mm axial translation + 360° rotation about vertical axis |
| Brand | Oxford Instruments |
|---|---|
| Origin | United Kingdom |
| Model | TeslatronPT |
| Maximum Magnetic Field | 18 T |
| Temperature Range | 1.5 K to 300 K (standard VTI) |
| Sample Bore Diameter | 50 mm |
| Cooling Method | Single-pulse-tube cryocooler |
| Sample Access | Top-loading probe mechanism |
| Vibration Level | Ultra-low (suitable for SQUID, STM, and optical spectroscopy) |
| Internal Cold Trap | Yes |
| Gas Exchange Mode | Static exchange gas (no forced flow across sample) |
| Compliance | Designed for GLP/GMP-adjacent research environments |
| Brand | Oxford Instruments |
|---|---|
| Origin | United Kingdom |
| Model | Triton |
| Cooling Power | >12 µW @ 20 mK (Triton 500), >6 µW @ 20 mK (Triton 300) |
| Base Temperature | < 10 mK |
| Sample Space | Ø290 mm × H240 mm (extendable to 440 mm) |
| Magnetic Field Compatibility | Up to 14 T |
| Helium-3 Inventory | 18 L (Triton 500), 11 L (Triton 300) |
| Cool-down Time | < 24 h |
| Operating Temperature Range | 10 mK – 30 K (full field) |
| Cryocooler | 1–2 W Pulse Tube Refrigerator |
| Compliance | Fully compatible with ISO/IEC 17025-aligned lab infrastructure, supports GLP/GMP audit trails via optional integrated logging |
| Brand | Oxford Instruments |
|---|---|
| Origin | United Kingdom |
| Model | TritonXL |
| Minimum Base Temperature | < 5 mK |
| Refrigeration Power | 1000 µW at 100 mK |
| Maximum Magnetic Field Compatibility | Up to 16 T |
| Integrated Cryocoolers | Dual 1.5 W Pulse Tube Refrigerators |
| Standard Warranty | 3 years (covers all system components, including third-party cryocoolers, pumps, and electronics) |
| Service Support | Factory-authorized service network across UK, Germany, USA, China, Japan, and India |
| Vibration Mitigation | Remote pump rack, rigid floor-standing cryostat support, electrical isolation between cryostat, gas lines, and pump station |
| Gas Handling System | Dry, oil-free pumping stack (roots + diaphragm + turbomolecular pumps), fully welded pneumatic circuit with high-integrity solenoid valves |
| Sample Access | Top- and bottom-loading options |
| RF Wiring Capacity | Up to 72 semi-rigid coaxial lines with optimized attenuators |
| Optical Integration | Optional fiber feedthroughs or optical windows |
| Control Interface | Advanced software suite with remote command protocol (TCP/IP), hardware interlocks, and audit-trail-capable operation logging |
| Brand | Physik |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Origin Category | Domestic (China) |
| Model | Ucryo-300 |
| Pricing | Available Upon Request |
| Brand | Physik |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Product Origin | Domestic (China) |
| Model | Vcryo-V-200 |
| Temperature Setpoint Range | 78.5 K – 500 K |
| Working Distance | 2 mm |
| Vibration Stability | ±5 nm |
| Unit Weight | 1.5 kg |
| Cooling Medium | Liquid Nitrogen |
| Initial Cool-down Time | <10 min |
| LN₂ Consumption Rate | 0.2 L/h |
| Compact Dimensions | 3 cm (thickness) × 29 cm (length) |
| Brand | PHYSIKE |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | CryoAce-100 |
| Cooling Medium | Helium Gas |
| Base Plate Diameters | 5 cm, 10 cm, 15 cm, 20 cm |
| Nominal Vibration Amplitude | 6–12 nm (RMS, dependent on base plate size and operating temperature) |
| Base Temperature Range | 2.4 K – 3.2 K |
| Standard Configuration | Top and/or Side Optical Windows, Vacuum Gauge, Calibrated Platinum Resistance Thermometer (PRT) |
| Integrated Cryo-Pumping | Multi-stage低温 adsorption pumps |
| Compressor Type | Air-Cooled Helium Compressor |
| Power Supply | Single-Phase AC, Low Power Consumption |
| Footprint | Compact Desktop Form Factor |
| Vacuum Maintenance | Self-Sustaining High Vacuum Without Continuous External Pumping |
| Brand | PHYSIKE |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Model | CryoAce-200 |
| Vibration Stability | 12 nm (RMS) |
| Cooling Medium | Helium Gas |
| Baseplate Diameters Available | 5 cm, 10 cm, 15 cm, 20 cm |
| Base Temperature Range | 2.4 K – 3.2 K (dependent on configuration) |
| Standard Viewports | Top and/or Side |
| Power Supply | Single-Phase, Low Power Consumption |
| Footprint | Compact Desktop Form Factor |
| Brand | PHYSIKE |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Model | Cryocloud-100 |
| Ultimate Temperature | < 350 mK |
| Cooling Source | 4 K Pulse Tube or Gifford-McMahon Refrigerator |
| Integrated 4 K Cold Head | Yes |
| Gas Recirculation System | External High-Speed Vacuum Pump Array + Purification & Condensation Loop |
| Liquid Nitrogen Cold Trap | Included |
| Thermal Switch | High-Performance Active Type |
| Optional Configurations | Top-Loading with Load-Lock Insert, Integrated Superconducting Magnet |
| Brand | PHYSIKE |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Model | Cryocloud-200 |
| Base Temperature | < 350 mK |
| Cooling Architecture | Split-system (external Qcryo® helium-recycling cryocooler) |
| Vibration Isolation | Active mechanical decoupling between compressor/coldhead and He-3 insert |
| Vacuum Compatibility | UHV-compatible (bakeable to 150 °C) |
| Optional Integration | Superconducting magnet (up to 9 T, persistent mode) |
| Brand | PHYSIKE |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | Cryocloud-300 |
| Pricing | Upon Request |
| Brand | PHYSIKE |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | Cryocloud-400 |
| Pricing | Upon Request |
| Brand | PHYSIKE |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Model | Cryocloud-500 |
| Pricing | Upon Request |
| Compatible Cryostat Platforms | Acryo-1.5K (top-loading 1.5 K cryostat), CryoM (dry, variable-temperature superconducting magnet system) |
| Base Temperature (no-load) | < 270 mK |
| Hold Time | > 60 hours |
| Cooling Power at 350 mK | > 100 µW |
| Internal Cryopumping | Integrated low-temperature adsorption pump |
| Helium-3 Circuit | Sealed, single-shot operation |
| Sample Environment | High-vacuum standard |
| Brand | PHYSIKE |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Model | Labcryo |
| Temperature Range | -50 °C to +200 °C |
| Temperature Stability | Better than ±25 mK |
| Cooling Method | Multi-stage Peltier (Thermoelectric) |
| Vacuum Feedthrough Options | Multi-pin, SMA / 2.92 mm / 1.85 mm Microwave, BNC, Triax, Fiber Optic |
| Sample Holders | Electrical pucks (DIP, LCC), Transmission holders, Solar cell mounts, Probe-based holders |
| Optical Windows | Gamma-ray, X-ray, UV, Vis, IR, THz-transparent options |
| Low-Temp Cabling | Twisted-pair, Flexible coaxial, Semi-rigid microwave, Triaxial cables |
| Mounting | Omnidirectional (no orientation dependency) |
| Power Supply | Standard AC input (no cryogens required) |
| Brand | PHYSIKE |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Product Origin | Domestic (China) |
| Model | Scryo-S-100 |
| Minimum Temperature | 2 K |
| Cryogen Medium | Helium Gas (Gaseous or Liquid Helium Compatible) |
| Temperature Range | 2 K to 420 K (standard), up to 800 K with high-temperature option |
| Cooling Method | Continuous-flow cryogenic system with integrated high-efficiency vaporizer and ultra-low-loss flexible transfer line |
| Standard Sensor | Calibrated ZrON resistance thermometer |
| Control Precision | High-stability closed-loop temperature control via external precision temperature controller |