Current Voltage Tester
Filter
Showing all 9 results
| Brand | EKO |
|---|---|
| Origin | Japan |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | MP-11 |
| Price Range | USD 4,200 – 7,000 (FOB) |
| Automation Level | Semi-Automatic |
| Effective Test Points per I-V Curve | 400 |
| Voltage Measurement Accuracy | ±1% FS |
| Current Measurement Accuracy | ±1% FS |
| Max Voltage Range | 10–1000 V |
| Max Current Range | 0.1–30 A |
| Power Range | 10 W–18 kW |
| Scan Time | 4–60 ms |
| Internal Storage Capacity | 300 I-V curves |
| Display | 128×64 LED monochrome LCD (no backlight) |
| Host Dimensions | 230 × 320 × 180 mm |
| Host Weight | 2.5 kg |
| Sensor Unit Dimensions | 210 × 85 × 55 mm |
| Sensor Unit Weight | 0.5 kg |
| Battery | 8× Ni-MH rechargeable cells (host), 1× 006P (sensor) |
| Compliance | IEC 61215, IEC 61646, IEC 62446-1, ASTM E1036, UL 1703 |
| Brand | Fluxim |
|---|---|
| Origin | Switzerland |
| Model | PAIOS |
| Price Range | USD 14,000 – 70,000 |
| Automation Level | Semi-Automatic |
| Effective Test Area | 20 mm² |
| Voltage Measurement Resolution | Sub-nanovolt (nV) |
| Current Measurement Resolution | Sub-picoampere (pA) |
| Sampling Rate | 60 MS/s |
| Time Resolution | 16 ns |
| Frequency Range | 10 mHz – 10 MHz |
| LED Rise Time | 100 ns |
| Current Range | ±100 mA |
| Voltage Range | ±12 V (optional ±60 V with SMU module) |
| Spectral Coverage (Multi-LED) | 360–1100 nm |
| Temperature Range (Optional Cryo/Hot Stage) | −120 °C to +150 °C |
| Brand | McScience |
|---|---|
| Origin | South Korea |
| Model | SS-LD50 |
| Automation Level | Fully Automatic |
| Effective Test Area | 55 mm × 55 mm |
| Voltage Measurement Accuracy | ±0.02% of reading |
| Current Measurement Accuracy | ±0.03% of reading |
| Spectral Classification | AAA (IEC 60904-9:2020 Ed.3, ASTM E927-19) |
| Light Source | Multi-channel High-Power LED Array |
| Spectral Tunability | Yes, per-channel LED current control |
| Compliance | IEC 61215, IEC 61646, IEC 62108, UL 1703, JIS C 8912 |
| Brand | PV Measurements |
|---|---|
| Origin | USA |
| Product Type | Imported Reference Solar Cell |
| Model | Outdoor Photovoltaic Reference Cell |
| Certification | Compliant with IEC 60904-2 |
| Effective Area | 1 cm² |
| Open-Circuit Voltage (Voc) Temperature Coefficient (TCR) | < 25 ppm/K |
| Voc Tolerance | ±1% |
| Shunt Resistance | 0.004 Ω (for split 156-cell configuration) or 0.13 Ω (for 20 mm × 40 mm shunt resistor, adjustable) |
| Integrated Sensor | Class A RTD-Pt100 (4-wire) |
| Electrical Interface | Amphenol Eco-Mate connectors (X2) for Voc (2-wire), Isc (2-wire), RTD (4-wire), and optional auxiliary cells (2-wire each) |
| Calibration Traceability | NREL (USA) or NIM (China) |
| Brand | Seaward |
|---|---|
| Origin | United Kingdom |
| Model | PV200 |
| Automation Level | Fully Automatic |
| Effective Test Area | 1 m² (per module or string) |
| Voltage Measurement Accuracy | ±1% of reading |
| Current Measurement Accuracy | ±1% of reading |
| Brand | ZOLIX |
|---|---|
| Model | DSR300 Series |
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Automation Level | Semi-Automatic |
| Effective Test Area | > Ø40 µm |
| Current Measurement Resolution | 10 pA |
| Light Spot Size | 40 µm (diffraction-limited) |
| Compatible Light Sources | Supercontinuum White-Light Laser, Picosecond Pulsed Lasers, Semiconductor Lasers, Halogen Lamps, Xenon Arc Lamps |
| Key Measurement Functions | Spectral Responsivity (A/W), Monochromatic & Power-Variable I–V, Irradiance-Dependent I–t (200 ms resolution), Bias-Dependent I–t, LBIC Mapping, Linearity Analysis, Response Speed (Transient Photovoltage/Photocurrent) |
| Brand | ZOLIX |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Manufacturer |
| Origin Category | Domestic (China) |
| Model | DSR600 |
| Pricing | Upon Request |
| Spectral Range | 200–2400 nm (configurable per variant) |
| Calibration Method | Substitution Method (NIM-traceable) |
| Optical Design | All-reflective, dual off-axis parabolic beam path |
| Spot Size | 1 mm (uniform across spectrum) |
| Measurement Capabilities | Spectral Responsivity (R(λ)), Bias-dependent R(λ), External Quantum Efficiency (EQE), Internal Quantum Efficiency (IQE), Reflectance/Transmittance, Short-Circuit Current Density (J<sub>sc</sub>), I–V Characterization |
| Light Sources | 150 W Xe lamp, 250 W Tungsten-Halogen lamp, EQ-99XFC broadband source |
| Detection | Lock-in amplifier (Stanford Research Systems SR240/SR830 compatible) |
| Imaging Aid | Integrated CCD-based monitoring optical path for real-time beam visualization and sample alignment |
| Brand | ZOLIX |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Domestic (PRC) |
| Model | SolarIV 100 |
| Automation Level | Semi-Automatic |
| Compliance | IEC 60904-1, IEC 60904-9 (Class AAA/ABA Simulators), ISO/IEC 17025-aligned testing workflow |
| Brand | ZOLIX |
|---|---|
| Model | SolarIV Series |
| Origin | Beijing, China |
| Manufacturer | ZOLIX (OEM/ODM Producer) |
| Type | Domestic |
| Automation Level | Semi-Automatic |
| Price Range | USD 14,000 – 72,000 (based on configuration) |
| Compliance | IEC 60904-9:2020 (Class A Solar Simulator), ASTM E927-22 |
| Core Instrumentation | Keithley 2400/2450 SourceMeter® (optional), QE-B1 Reference Cell (calibrated to NREL traceability), IV-Software v3.x |