| Brand | Anton Paar |
|---|---|
| Origin | Austria |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | Julia DSC |
| Instrument Type | Heat-Flux DSC |
| Special Function | Modulated DSC (MDSC®-compatible) |
| Simultaneous Sample Capacity | Up to 70 samples (with auto-sampler) |
| Temperature Range | −170 °C to 700 °C |
| Temperature Accuracy | < 0.1 K |
| Temperature Precision | 0.01 °C |
| Heating Rate | 0–300 K/min |
| Cooling Rate | 0–200 K/min |
| DSC Signal Range | ±2500 mW |
| Temperature Stability | ±0.1 °C |
| Control Modes | Dynamic & Isothermal |
| Measurement Principle | Heat-Flux Differential Scanning Calorimetry |
| Brand | HESON |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | DSC |
| Sample Capacity | Single |
| Temperature Range | Ambient to 600 °C |
| Temperature Accuracy | ±0.1 °C |
| Heating/Cooling Rate | 0.1–100 °C/min |
| Temperature Precision | ±0.01 °C |
| DSC Signal Range | 0 to ±600 mW |
| Temperature Stability (Drift) | ±0.01 °C |
| DSC Resolution | 0.001 mW |
| Temperature Resolution | 0.01 °C |
| Gas Flow Control | Dual-channel automatic switching, 0–300 mL/min (customizable) |
| Calibration Standards Included | Indium, Tin, Lead |
| Thermocouple Configuration | Triple thermocouples (sample, furnace ambient, overheat safety) |
| Power Supply | AC 220 V / 50 Hz |
| Interface | Standard USB |
| Display | 7-inch 24-bit color LCD touchscreen |
| Brand | HESON |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | DSC |
| Sample Capacity | Single-sample |
| Temperature Range | Ambient to 600 °C |
| Temperature Accuracy | ±0.1 °C |
| Heating/Cooling Rate | 0.1–100 °C/min |
| DSC Signal Range | 0–±600 mW |
| Temperature Stability | ±0.1 °C |
| Temperature Resolution | 0.01 °C |
| DSC Resolution & Sensitivity | 0.001 mW |
| Atmosphere Control | Dual-gas auto-switching (N₂/O₂), Flow Range: 0–300 mL/min |
| Calibration Standards Included | Indium, Tin, Lead |
| Compliance | GB/T 41873–2022, GB/T 19466.3–2004 |
| Brand | INNUO |
|---|---|
| Origin | Shanghai, China |
| Model | YND-OM4 |
| Temperature Range | RT to 500 °C |
| Temperature Accuracy | ±0.01 °C |
| Heating/Cooling Rate | 0.1–80 K/min |
| Sample Capacity | Up to 8 samples per run (configurable for 4/6/8) |
| DSC Range | 0 to ±500 mW |
| DSC Resolution | 0.01 mW |
| DSC Sensitivity | 0.01 mW |
| Gas Control | Dual-channel mass flow control (N₂/O₂), 0–200 mL/min, accuracy ±0.2 mL/min |
| Power Supply | AC 220 V, 50 Hz |
| Interface | Integrated USB 2.0 |
| Display | 7-inch color capacitive touchscreen |
| Compliance | GB/T 19466.3–2009 / ISO 11357-3:1999 (OIT determination) |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | DSC 2 |
| Temperature Range | –150 to 700 °C |
| Heating/Cooling Rate | 0.02 to 300 K/min |
| Sensor Type | FRS 6 (56 thermocouples) or HSS8 (120 thermocouples) |
| Autosampler Capacity | 34 positions |
| Compliance | ASTM E794, ISO 11357, USP <1163>, GLP/GMP-ready architecture |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | DSC 3 / DSC 3+ |
| Temperature Range | RT to 1100 °C |
| Temperature Accuracy | ±0.05 °C |
| Heating/Cooling Rate | 0.1–150 K/min (DSC 3) or 0.1–250 K/min (DSC 3+) |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | DSC 3+ |
| Temperature Range | -150 to 700 °C |
| Temperature Accuracy | ±0.1 °C |
| Heating/Cooling Rate | 0.02–300 K/min |
| Sensor Options | FRS 6+ (56 thermocouples) or HSS 9+ (120 thermocouples) |
| TAWN Resolution (FRS/HSS) | 0.12/0.2 °C |
| TAWN Sensitivity (FRS/HSS) | 11.9/56 µW/°C |
| Indium Response Ratio (FRS) | >155 mW/°C |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | DSC 5+ |
| Instrument Type | Differential Scanning Calorimeter (DSC) |
| Sample Capacity | Multi-sample (automated) |
| Operating Modes | Power Compensation & Heat Flux (FlexMode™) |
| Sensor Configuration | MultiStar™ sensor with 136 thermocouple pairs |
| Calibration | FlexCal™ automated calibration |
| Atmosphere Control | Integrated gas-purged crucible chamber |
| Modular Architecture | Yes |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | DSC Series (UV-DSC, Optical DSC, Microscope-DSC) |
| Pricing | Available Upon Request |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | DSC1+ Microscopy System, HP DSC1+ Microscopy System |
| Temperature Range | DSC1+: −150 to 700 °C |
| HP DSC1+ | RT to 700 °C |
| Temperature Accuracy | ±0.1 °C |
| Heating/Cooling Rate | 0.02–300 °C/min |
| Heat Flow Sensitivity | 0.04 µW (FRS5 sensor) / 0.01 µW (HSS8 sensor) |
| Pressure Range (HP variant) | Vacuum to 2 MPa |
| Microscope Integration | Compatible with Olympus, Leica, and other OEM optical platforms |
| Compliance | Designed for GLP/GMP environments with optional 21 CFR Part 11–compliant software audit trail |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | DSC3+ |
| Temperature Range | −150 °C to 700 °C (standard), up to 1100 °C (optional furnace) |
| Temperature Accuracy | ±0.1 °C |
| Heating/Cooling Rate | 0.02–250 K/min |
| Heat Flow Sensitivity | 0.04 µW (FRS 5+ sensor), 0.02 µW (HSS 8+ sensor) |
| Sensor Type | MultiSTAR® DSC Sensor (56- or 120-pair Au/Au-Pd thermocouples, star-arranged on ceramic substrate with Al₂O₃ coating) |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | DSC3+ |
| Temperature Range | –150 to 700 °C |
| Temperature Accuracy | ±0.1 °C |
| Heating/Cooling Rate | 0.02–300 K/min (heating), 0.02–50 K/min (cooling) |
| Heat Flow Sensitivity | 0.04 µW (FRS 6+ sensor), 0.02 µW (HSS 9+ sensor) |
| Sensor Configuration | 56-pair (FRS 6+) or 120-pair (HSS 9+) Au/Au-Pd thermocouples in star geometry |
| Compliance | ASTM E794, ISO 11357, USP <1163>, FDA 21 CFR Part 11 (with optional software modules) |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Instrument Type | DSC |
| Temperature Range | –95 °C to 1000 °C |
| Temperature Accuracy | ±0.1 °C |
| Heating/Cooling Rate | 6–3,000,000 K/min (UFS 1 sensor) or 6–2,400,000 K/min (UFH 1 sensor) |
| Simultaneous Sample Measurement | Multiple |
| Compliance | Designed for GLP/GMP environments with audit-trail-capable software |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | Flash DSC 2+ |
| Temperature Range | −95 °C to 1,000 °C |
| Heating Rate | 6 K/min to 2,400,000 K/min |
| Cooling Rate | 6 K/min to 240,000 K/min |
| Maximum Heat Flow Signal | 20 mW |
| Heat Flow Noise | < 0.5 µW |
| Sensor Type | UFS1 MEMS-based chip calorimeter with 16 thermocouple pairs (8 per sample/reference side) |
| Measurement Principle | Dynamic power compensation |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | FP82HT / FP84HT |
| Temperature Range | –60 to 375 °C |
| Temperature Repeatability | ±0.2 °C |
| Optical Field of View | Ø2.5 mm (FP82HT), Ø2.0 mm (FP84HT) |
| DSC Sensor | Au–Ni thermopile, 5 thermocouple pairs |
| Calorimetric Sensitivity | 13 mV/mW |
| Sample Environment | Sealed furnace chamber with inert gas compatibility |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | HP DSC 2+ |
| Temperature Range | RT to 500 °C / 700 °C |
| Temperature Accuracy | ±0.1 °C |
| Heating/Cooling Rate | 0.1–50 K/min |
| Pressure Range | 0–10 MPa |
| Gas Flow Control | External pressure & mass flow controller supported |
| Atmosphere Compatibility | Inert, oxidizing, reducing, reactive (e.g., N₂, O₂, H₂, CO₂, C₂H₄, CH₃Br), with safety restrictions for combustible/toxic gases |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | HP DSC1 |
| Temperature Range | 22–500 °C (optional to 700 °C) |
| Heating/Cooling Rate | 0.1–50 °C/min |
| Pressure Range | 0–10 MPa |
| Heat Flow Sensitivity | 0.04 µW (FRS5 sensor) / 0.01 µW (HSS8 sensor) |
| Sensor Type | FRS5 (56 thermocouple pairs, star configuration) / HSS8 (120 thermocouple pairs, triple-layer configuration) |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | HS84 |
| Temperature Range | RT to 375 °C (optional cooling to –90 °C) |
| Heating/Cooling Rate | 0.1–20 K/min |
| Light Aperture | 2 mm |
| Sensor Type | DSC ceramic sensor with 56 thermocouple pairs |
| Sample Carriers | Glass slides, top cover glass, aluminum/glass/sapphire crucibles |
| Crucible Dimensions | Ø6 mm / 40 µL |
| Display | 7″ touch-sensitive VGA color screen |
| Supported Languages | English, German, French, Spanish, Chinese, Japanese, Korean, Russian |
| User Shortcuts | 12 per user |
| Compliance | ASTM F766, EN ISO 3146 |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | TOPEM™ TMDSC |
| Category | Imported Instrument |
| Distributor Type | Authorized General Distributor |
| Pricing | Available Upon Request |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | UV-DSC1 |
| Temperature Range | −150 to 700 °C |
| Temperature Accuracy | ±0.1 °C |
| Heating Rate | 0.02–300 °C/min |
| Heat Flow Sensitivity | 0.04 µW (FRS5 sensor) / 0.01 µW (HSS8 sensor) |
| UV Wavelength Range | 240–400 nm (optional extension to 400–700 nm, visible) |
| UV Irradiance | 4500 mW/cm² (at 365 nm) |
| Brand | Nanjing Dazhan |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Direct Manufacturer |
| Origin Category | Domestic (China) |
| Model | DTA-3320A |
| Instrument Type | Differential Thermal Analyzer (DTA) |
| Temperature Range | Ambient to 1150 °C |
| Temperature Accuracy | ±0.1 °C |
| Temperature Resolution | 0.01 °C |
| Temperature Repeatability | ±0.1 °C |
| Heating/Cooling Rate | 0.1–100 °C/min |
| DTA Signal Range | 0–±2000 µV (expandable) |
| DTA Sensitivity | 0.01 µV |
| Baseline Adjustment | Adjustable slope and intercept |
| Calibration | Integrated standard reference materials with one-click temperature calibration |
| Control System | ARM-based embedded controller |
| Interface | USB 2.0 bidirectional communication |
| Display | 7-inch 24-bit color LCD touchscreen |
| Furnace Design | Top-opening vertical furnace architecture |
| Atmosphere Control | Programmable internal gas switching (N₂, Ar, air, O₂) |
| Power Supply | AC 220 V, 50 Hz (custom voltage/frequency available) |
| Brand | Netzsch |
|---|---|
| Origin | Germany |
| Model | DSC 204 F1 Phoenix |
| Instrument Type | Differential Scanning Calorimeter (DSC) |
| Temperature Range | –180 °C to 700 °C |
| Temperature Accuracy | ±0.1 K |
| Heating/Cooling Rate | 0 to 200 K/min |
| Sensor Options | τ-type (time constant 0.6 s), μ-type (high-sensitivity) |
| Cooling Options | Liquid nitrogen (LN₂), mechanical refrigeration (–85 °C to 600 °C), compressed air, cooling cup |
| Sample Capacity | Multi-sample capability (optional 64-position ASC auto-sampler) |
| Atmosphere Control | Integrated mass flow controller, gas-tight furnace design compatible with FTIR/MS coupling |
| Brand | Netzsch |
|---|---|
| Origin | Germany |
| Model | DSC 204 HP Phoenix |
| Instrument Type | Differential Scanning Calorimeter (DSC) |
| Temperature Range | –150 °C to 600 °C (under vacuum to 15 MPa) |
| Temperature Accuracy | ±0.1 K |
| Heating/Cooling Rate | 0–100 K/min |
| Pressure Range | 0–15 MPa (0–150 bar) |
| Atmosphere Compatibility | Static or dynamic O₂, N₂, Ar, He, H₂, CO₂, CH₄, and other process gases |
| Brand | Netzsch |
|---|---|
| Origin | Germany |
| Instrument Type | DSC |
| Temperature Range | −170 °C to 600 °C |
| Temperature Accuracy | ±0.1 K |
| Heating/Cooling Rate | 0 to 500 °C/min |
| Detection Limit | 0.1 μW |
| Atmosphere Control | Dynamic or static inert, reducing, or oxidizing (automated gas switching) |
| Cooling Options | Compressed air, mechanical refrigeration, liquid nitrogen (dual-cooling system optional, software-switchable) |
| Optional Accessories | Photo-DSC module, ASC automatic sample changer (20 positions), TMDSC upgrade |
| Software Features | Intelligent Mode, Expert Mode, Auto-Calibration, Auto-Analysis, Pattern Recognition, Tau-R® advanced thermal lag correction, DSC spectral database and search engine |
| Brand | NETZSCH |
|---|---|
| Origin | Germany |
| Model | DSC 300 Caliris Classic |
| Instrument Type | Differential Scanning Calorimeter (DSC) |
| Temperature Range | −170 °C to 600 °C |
| Heating/Cooling Rate | 0.001–100 K/min |
| Temperature Accuracy | ±0.1 K (intrinsic) |
| Brand | NETZSCH |
|---|---|
| Origin | Germany |
| Model | DSC 300 Caliris Supreme-H |
| Instrument Type | Differential Scanning Calorimeter |
| Temperature Range | −180 °C to 750 °C |
| Heating/Cooling Rate | 0 to 200 K/min |
| Module Architecture | Interchangeable Multi-Module Platform |
| Compliance | GLP, GMP, FDA 21 CFR Part 11 (with optional software package) |
| Brand | Netzsch |
|---|---|
| Origin | Germany |
| Model | DSC 300 Caliris® Select-P |
| Instrument Type | Differential Scanning Calorimeter (DSC) |
| Temperature Range | –170 to 600 °C |
| Heating/Cooling Rate | 0 to 500 K/min |
| Compliance | GLP/GMP, FDA 21 CFR Part 11 (software-enabled), ISO 11357, ASTM E794, ASTM E1356 |
| Brand | Netzsch |
|---|---|
| Origin | Germany |
| Instrument Type | DSC |
| Temperature Range | −170 to 650 °C |
| Heating/Cooling Rate | 0–100 K/min |
| Module Configuration | Sensor + Furnace Assembly (S-Module) |
| Compliance | GLP/GMP, FDA 21 CFR Part 11 (with optional software package) |
| Key Software Features | BeFlat®, Tau-R Correction, TM-DSC (optional), Automatic Baseline Subtraction, Crystallinity Calculation, Cp Measurement |
| Brand | NETZSCH |
|---|---|
| Origin | Germany |
| Model | DSC 3500 Sirius |
| Temperature Range | −170 °C to 600 °C |
| Temperature Accuracy | ±0.1 °C |
| Heating/Cooling Rate | 0–100 K/min |
| Sample Capacity (with ASC) | Up to 20 positions (samples + references) |
| Instrument Type | Differential Scanning Calorimeter |
| 炉 Body Material | Silver-based furnace block |
| Sensor Architecture | Monolithic sensor design |
| Brand | Netzsch |
|---|---|
| Origin | Germany |
| Model | DSC 404 F1 Pegasus |
| Temperature Range | −150 to 2000 °C |
| Temperature Accuracy | ±0.1 K |
| Heating/Cooling Rate | 0–50 K/min |
| Sensor Types | Replaceable DSC (−150 to 1650 °C) and DTA (up to 2000 °C) |
| Vacuum Capability | High-vacuum sealed system |
| Gas Control | Integrated stainless-steel gas lines with metal-encapsulated mass flow controllers (MFCs) |