Differential Scanning Calorimeter
Filter
Showing 31–41 of 41 results
| Brand | Netzsch |
|---|---|
| Origin | Germany |
| Model | DSC 404 F3 Pegasus |
| Temperature Range | −150 to 2000 °C |
| Temperature Accuracy | ±0.1 K |
| Heating/Cooling Rate | 0–50 K/min |
| Brand | PerkinElmer |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | DSC 4000 / DSC 6000 |
| Instrument Type | Differential Scanning Calorimeter (DSC) |
| Temperature Range | –100 °C to 600 °C (with optional cryogenic and high-temp accessories) |
| Temperature Accuracy | ±0.1 °C (traceable to NIST standards) |
| Heating/Cooling Rate | 0.1–100 K/min (programmable in 0.1 K/min increments) |
| Brand | PerkinElmer |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | DSC 8000 |
| Simultaneous Sample Capacity | Multiple |
| Instrument Type | Power-Compensated DSC |
| Temperature Range | –180 °C to 750 °C |
| Heating/Cooling Rate | 0.01 °C/min to 300 °C/min |
| Dynamic Heat Flow Range | ±800 mW |
| Furnace Material | Platinum-Iridium Alloy |
| Modulated DSC (MDSC®) | Standard |
| Cooling Options | Two-stage mechanical cooler, three-stage mechanical cooler, automated liquid nitrogen cooling |
| Dual Digital Mass Flow Controllers | Standard |
| Optional Accessories | 96-position autosampler, high-pressure cell (up to 600 psi), UV photo-DSC module, isolated sample chamber for hazardous materials |
| Brand | PerkinElmer |
|---|---|
| Origin | USA |
| Manufacturer | PerkinElmer, Inc. |
| Model | DSC 8500 |
| Temperature Range | –180 °C to 750 °C |
| Heating/Cooling Rate | up to 750 K/min (controlled), >1000 K/min (free cooling) |
| Heat Flow Dynamic Range | ±800 mW |
| Calorimetric Accuracy | < ±0.2% |
| Sensitivity | 0.18 µW |
| Data Acquisition Rate | up to 100 Hz |
| Standard Features | Dual-channel digital mass flow controllers, automated lid, integrated cooling accessory |
| Optional Accessories | 96-position autosampler, high-pressure DSC cell, isolated DSC module, photo-DSC unit, DSC–Raman hyphenated system |
| Brand | Reinstek |
|---|---|
| Origin | Anhui, China |
| Manufacturer Type | Direct Manufacturer |
| Model | DSC-790 |
| Sample Capacity | Single |
| Instrument Type | Heat-Flow DSC |
| Temperature Range | −150 °C to 700 °C |
| Temperature Accuracy | ±0.1 °C |
| Temperature Precision | ±0.1 °C |
| DSC Heat Flow Range | ±6000 mW |
| Cooling Options | Liquid Nitrogen, Mechanical, or Ambient Air |
| Heating Rate | 0.01–100 °C/min |
| Heat Flow Resolution | 0.1 µW |
| Calorimetric Accuracy | ±0.1% |
| Calorimetric Precision | ±0.1% |
| Atmosphere Control | Dual-gas inlet with software-driven automatic switching |
| Dimensions (W×D×H) | 950 mm × 555 mm × 360 mm |
| Weight | 30 kg |
| Power Supply | 220–240 VAC, 50/60 Hz |
| Brand | Rigaku |
|---|---|
| Origin | Japan |
| Instrument Type | DSC |
| Temperature Range | Ambient to 1500 °C |
| Manufacturer Status | Authorized Distributor (Non-OEM) |
| Origin Category | Imported Instrument |
| Model | DSC8271 |
| Brand | Rigaku |
|---|---|
| Origin | Japan |
| Instrument Type | DSC |
| Temperature Range | −170 °C to 725 °C |
| Configuration | Imported System |
| Distribution Model | Authorized Distributor |
| Brand | Shanda |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | SD-L2 |
| Sample Capacity | Multi-sample simultaneous measurement |
| Instrument Type | Heat-Flow DSC |
| Temperature Range | −100 °C to 600 °C |
| Programmable Temperature Control | Heating, Isothermal, Cooling |
| Heating/Cooling Rate | 0.1–100 K/min |
| Scan Modes | Dynamic heating, dynamic cooling, isothermal hold |
| Temperature Accuracy | ±0.01 °C (typical, calibrated per ASTM E794 & ISO 11357-1) |
| Baseline Stability | <0.5 µW over 30 min at 50 °C |
| Sensor Resolution | 0.01 µW |
| Temperature Sensing | Dual independent platinum RTD sensors (furnace + sample) |
| Control Algorithm | Adaptive dynamic PID with FTC/STC dual-mode selection |
| Data Acquisition | 1–10 Hz user-selectable sampling rate |
| Communication Interface | USB 2.0 with auto-reconnect protocol |
| Atmosphere Control | Dual independent gas channels (N₂, O₂, Ar, air), software-switched via solenoid valves |
| Calibration Standards | Indium, Zinc, Tin, and Sapphire (per ISO 11357-2) |
| Brand | Techcomp |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Product Origin | Domestic (China) |
| Model | CRY-2A / CRY-1A |
| Price Range | USD 7,000–14,000 (FOB Shanghai) |
| Temperature Range | Ambient to 1450 °C |
| Temperature Accuracy | ±0.1 °C |
| Heating/Cooling Rate | 0.1–50 K/min |
| Brand | Techcomp |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Model | DSC30 |
| Temperature Range | Ambient to 750 °C |
| Temperature Accuracy | ±0.1 °C |
| Heating/Cooling Rate | 0.1–100 °C/min |
| Baseline Stability | < ±0.1 µW over 30 min |
| Atmosphere Control | Dual-channel, 0–200 mL/min (0.1 mL/min resolution) |
| Cooling Speed | 550 °C → −40 °C in ≤35 min |
| Temperature Control Precision | < ±0.03 °C (isothermal), Linearity Error < 0.1 °C @ 10 °C/min |
| Sensor | Integrated NiCr/NiSi thermopile with symmetrical sample-stage electrodes |
| Brand | Zhonglu |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Differential Thermal Analysis (DTA) |
| Model | DTA-1350 |
| Temperature Range | RT to 1350 °C |
| Temperature Accuracy | ±0.1 °C |
| Temperature Precision | ±0.1 °C |
| Temperature Stability | ±0.1 °C |
| Heating/Cooling Rate | 0.1–100 K/min |
| DTA Signal Range | 0–±2000 µV |
| DTA Sensitivity | 0.01 µV |
| Temperature Resolution | 0.01 °C |
| Control Method | PID-based Programmable Temperature Control |
| Data Interface | USB 2.0 |
| Display | 7-inch 24-bit color capacitive touchscreen |
| Sensor Material | Corrosion- and oxidation-resistant alloy |
| Atmosphere Control | Automated internal gas switching |
| Calibration Standard | Certified Sn reference material included |
| Compliance | ASTM E794, ISO 11357-1, GB/T 19466.1–2004 |