Direct Reading Spectrometer
Filter
Showing 31–60 of 61 results
| Brand | FPI |
|---|---|
| Origin | Zhejiang, China |
| Instrument Type | Benchtop |
| Excitation Source | Spark |
| Detector | CCD (Charge-Coupled Device) |
| Wavelength Range | Configurable |
| Sample Compatibility | Fe-, Al-, Cu-based alloys |
| Optical Design | Paschen-Runge mount |
| Environmental Operation | Factory-floor compatible |
| Gas Purge | Sealed argon-circulation optical chamber with quad-channel argon purge |
| Software Features | Real-time drift correction, intelligent curve selection, grade identification, CE/CRE calculation, QC limit enforcement, automated system diagnostics |
| Compliance Context | Designed for GLP-compliant metal analysis workflows |
| Brand | FPI |
|---|---|
| Origin | Zhejiang, China |
| Instrument Type | Benchtop |
| Excitation Source | Spark |
| Detector | CCD (Charge-Coupled Device) |
| Wavelength Range | Configurable (130–800 nm typical for spark OES) |
| Optical Configuration | Paschen-Runge mount with dual vacuum-UV/visible chambers |
| Number of Simultaneously Acquired Spectral Lines | >10,000 |
| Analytical Elements | Up to 72 metallic and non-metallic elements (e.g., C, P, S, N, Si, Mn, Cr, Ni, Cu, Al, Ti, Mo, V, Co, Nb, B, Ca, Mg, Zn, Pb, Sn, As, Bi, rare earths) |
| Calibration Flexibility | On-site matrix and element expansion without hardware modification |
| Compliance | Designed to support ISO/IEC 17025, ASTM E415, ASTM E1086, ASTM E3061, and GB/T 4336 workflows |
| Brand | FPI |
|---|---|
| Origin | Zhejiang, China |
| Instrument Type | Benchtop |
| Excitation Method | Spark |
| Detector Type | Charge-Coupled Device (CCD) |
| Wavelength Coverage | Configurable (130–800 nm typical for metal analysis) |
| Spectral Resolution | ≤ 10 pm (typical at 200 nm) |
| Optical System | Paschen-Runge mount with dual vacuum-UV/visible chambers |
| Number of Simultaneous Detection Pixels | > 30,000 per CCD |
| Calibration Flexibility | Multi-matrix, on-site element/basis expansion supported |
| Compliance | Designed to support ISO 17025-compliant workflows, ASTM E415, E1086, and GB/T 4336 methodologies |
| Brand | FPI |
|---|---|
| Origin | Zhejiang, China |
| Instrument Type | Benchtop |
| Excitation Source | Spark |
| Detector | Charge-Coupled Device (CCD) |
| Wavelength Coverage | Configurable (typically 130–800 nm) |
| Spectral Resolution | < 10 pm (at 200 nm) |
| Optical System | Pascchen-Runge Mount with Dual Chambers (UV + VIS) |
| Number of Simultaneous Spectral Lines | > 9,000 |
| Calibration Flexibility | Full-Spectrum Multi-Matrix Capability |
| Compliance | Designed to support ISO/IEC 17025 workflows, ASTM E415, E1086, and GB/T 4336 |
| Brand | FPI |
|---|---|
| Origin | Zhejiang, China |
| Model | M5000 PLUS |
| Instrument Type | Benchtop |
| Excitation Source | Spark |
| Detector Type | Scientific-grade CMOS |
| Wavelength Range | Configurable (UV–VIS, typically 130–800 nm) |
| Optical Design | Dual-chamber with dedicated UV optical path |
| UV Optimization | Uncoated high-quantum-efficiency CMOS for N, C, S, P detection |
| Stability Architecture | Cast aluminum vacuum-sealed spectrometer chamber with 4-stage stress-relief annealing and active temperature stabilization (±0.1 °C) |
| Light Source | Fully digital pulsed spark generator with real-time energy optimization (RTMC) |
| Software Capability | Full-spectrum acquisition, model-free analysis via intelligent calibration curves, remote firmware update & health monitoring |
| Compliance Framework | Designed to support GLP/GMP workflows, ASTM E415, ISO 11573, and GB/T 4336 analytical protocols |
| Brand | FPI |
|---|---|
| Origin | Zhejiang, China |
| Model | M5000 PLUS F |
| Instrument Type | Benchtop |
| Excitation Method | Spark |
| Detector Type | Scientific-grade CMOS |
| Focal Length | 400 mm |
| Grating Line Density | 2400 l/mm (Visible), 3600 l/mm (UV) |
| Wavelength Range | 140–680 nm |
| Spectral Acquisition Mode | Full-Spectrum Direct Reading |
| Brand | FPI |
|---|---|
| Origin | Zhejiang, China |
| Instrument Type | Benchtop |
| Excitation Method | Spark |
| Detector Type | Scientific-grade CMOS |
| Wavelength Range | Configurable (130–800 nm) |
| Optical System | Dual-chamber with dedicated vacuum UV optical path for N, C, S, P |
| Spectral Resolution | ≤ 10 pm at 200 nm |
| Effective Pixel Count | ≥ 4.2 MP (full-frame CMOS) |
| Analysis Speed | < 30 s per sample (including flushing, sparking, and quantification) |
| Calibration Stability | ±0.5% RSD over 8 hours (under controlled lab conditions) |
| Compliance | Meets ISO 11577:2022, ASTM E415-22, GB/T 4333.1–2022 |
| Brand | FPI |
|---|---|
| Origin | Zhejiang, China |
| Instrument Type | Benchtop |
| Excitation Source | Spark |
| Detector | Scientific-grade CMOS |
| Wavelength Coverage | Configurable (130–800 nm typical) |
| Optical Configuration | Dual-chamber (Vacuum UV + Visible/NIR) |
| UV Optimization | Dedicated uncoated UV optical path for N, C, S, P analysis |
| Spectral Resolution | ≤ 10 pm at 200 nm (typical) |
| Channel Flexibility | Full-spectrum acquisition — no fixed channels |
| Software Compliance | Supports ASTM E415, E1086, ISO 11577, and GLP/GMP audit trails per FDA 21 CFR Part 11 requirements |
| Thermal Stability | Thermostatically controlled optical chamber (±0.1 °C) |
| Mechanical Construction | Stress-relieved die-cast aluminum optical housing (4-stage annealing) |
| Brand | FPI |
|---|---|
| Origin | Zhejiang, China |
| Instrument Type | Benchtop |
| Excitation Source | Spark |
| Detector | Charge-Coupled Device (CCD) |
| Wavelength Coverage | Configurable (typically 130–800 nm) |
| Spectral Resolution | ≤ 10 pm (typical at 200 nm) |
| Optical System | Paschen-Runge Mount with Dual Chambers (UV + VIS) |
| Number of Simultaneously Acquired Spectral Lines | > 9,000 |
| Calibration Flexibility | Full-spectrum recalibration without hardware modification |
| Compliance | Designed to support ISO/IEC 17025 workflows, ASTM E415, E1086, and GB/T 4336 methodologies |
| Brand | GNR |
|---|---|
| Origin | Italy |
| Model | S5 |
| Instrument Type | Floor-Standing |
| Excitation Method | Spark |
| Focal Length | 500 mm |
| Groove Density | 3600 lines/mm |
| Wavelength Range | 130–900 nm |
| Detection Mode | Full-Spectrum CCD |
| Vacuum Optical Chamber | Integrated, Sealed |
| Elemental Coverage | C, P, S, N, Al, Ni, Cr, Mn, Cu, Mo, V, Ti, Co, Nb, W, Sn, Pb, Zn, Mg, Ca, Si, Fe, As, Bi, Sb, etc. |
| Brand | Horde Electric |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | OEM Manufacturer |
| Instrument Type | Benchtop |
| Excitation Method | Spark Discharge |
| Detector Type | CCD-based Multi-Channel Array |
| Focal Length | 400 mm |
| Grating Groove Density | 2700 lines/mm |
| Wavelength Range | 120–800 nm |
| Analog-to-Digital Resolution | 16-bit per pixel |
| Optical Architecture | Paschen-Runge Mount with Rowland Circle Design |
| Vacuum System | Intermittent Vacuum Maintenance |
| Compliance | ASTM E415, ISO 11573, GB/T 4336 (Chinese National Standard for Spark OES) |
| Brand | JB |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Instrument Type | Benchtop |
| Excitation Method | Spark |
| Detector Type | CCD-based Multi-Channel Array |
| Focal Length | 401 mm |
| Grating Groove Density | 2400 lines/mm |
| Wavelength Range | 140–680 nm |
| Optical Configuration | Paschen–Runge Mount |
| Number of Simultaneous Analytical Channels | Not Applicable (Full-Spectrum CCD Acquisition) |
| Compliance | Meets ISO 11573:2021 (Metallic materials — Spark optical emission spectrometry), ASTM E415–22 (Standard Test Method for Analysis of Carbon and Low-Alloy Steel by Spark Atomic Emission Spectrometry) |
| Brand | Microlink / BEIJING MICHEM TECHNOLOGY LTD. |
|---|---|
| Origin | Zhejiang, China |
| Instrument Type | Benchtop |
| Excitation Source | Spark |
| Detector | Scientific-grade CMOS array (replacing legacy CCD) |
| Focal Length | 1000 mm |
| Grating Density | 3600 lines/mm |
| Wavelength Range | 140 nm – 680 nm |
| Number of Simultaneous Detection Channels | 96 |
| Optical System | Dual-chamber vacuum-UV + UV-Vis configuration |
| Structural Material | Stress-relieved die-cast aluminum optical chamber (4-stage annealing) |
| Thermal Management | Active chamber temperature stabilization with laminar purge gas flow |
| Spectral Optimization | RTMC (Real-Time Multi-Channel) calibration and drift compensation algorithm |
| Compliance | Designed to support ISO/IEC 17025 workflows, ASTM E415, ASTM E1086, ASTM E3061, and GB/T 4336–2016 methodologies |
| Brand | NCS |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer | NCS (National Center for Steel & Iron Research) |
| Instrument Type | Floor-standing |
| Excitation Method | Spark Discharge |
| Detector Type | Photomultiplier Tube (PMT) |
| Focal Length | 750 mm |
| Grating Line Density | 2400 lines/mm |
| Wavelength Range | 120–800 nm |
| Number of Analytical Channels | 48 |
| Dispersion | 0.55 nm/mm (1st order), 0.275 nm/mm (2nd order) |
| Optical Resolution | < 0.01 nm |
| Selectable Spectral Lines | 240 |
| Dimensions (W×D×H) | 139 cm × 80 cm × 117 cm |
| Weight | ~400 kg |
| Power Supply | 220 V ±10%, Single-phase, 10 A, 2.5 kVA |
| Brand | NCS |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Benchtop |
| Excitation Method | Spark Discharge |
| Detector Type | Charge-Coupled Device (CCD) |
| Focal Length | 500 mm |
| Grating Groove Density | 2700 lines/mm |
| Wavelength Range | 160–500 nm |
| Number of Detection Channels | 128 |
| Power Supply | 220 V ±10%, Single-Phase, 10 A, 2.5 kVA |
| Weight | 80 kg |
| Dimensions (W×D×H) | 470 × 872 × 435 mm |
| CCD Pixel Count | 3648 + 46 |
| Pixel Size | 8 µm |
| Optical Design | Paschen–Runge Mount with Holographic Concave Grating |
| Spectral Resolution (Pixel Level) | 0.005926 nm |
| Linear Dispersion | 0.7407 nm/mm |
| Argon Consumption | 60 mL/min (Standby), Tidal Purge Mode Enabled |
| Brand | NCS (China Iron and Steel Research Institute Group) |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Benchtop |
| Excitation Method | Spark Discharge |
| Detector Type | Charge-Coupled Device (CCD) |
| Focal Length | 500 mm |
| Grating Groove Density | 2700 lines/mm |
| Wavelength Range | 130–800 nm (enabling detection of N, Li, Na, K, and other elements) |
| Spectral Coverage | Full-spectrum acquisition |
| Pixel Array | 3648 + 46 pixels |
| Pixel Size | 8 µm |
| Optical Architecture | Paschen-Runge mounting with holographic concave grating |
| Temperature Stability | ±0.1 °C via integrated thermostatic shielding |
| Argon Consumption | 60 mL/min in standby mode |
| MTBF | >3000 hours |
| Dimensions (W×D×H) | 470 × 872 × 435 mm |
| Weight | 100 kg |
| Power Requirement | 220 V ±10%, single-phase, 10 A, 2.5 kVA |
| Brand | NCS |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Benchtop |
| Excitation Method | Spark Discharge |
| Detector Type | CMOS Array |
| Focal Length | 500 mm |
| Grating Groove Density | 2700 lines/mm |
| Wavelength Range | 130–800 nm |
| Power Supply | 220 V ±10%, Single-Phase, 10 A, 2.5 kVA |
| Weight | 100 kg |
| Argon Consumption (Standby) | 60 mL/min |
| Optical System | Paschen-Runge Mount with Holographic Grating |
| Temperature Control Precision | ±0.1 °C |
| Startup Time (Cold) | 30 min |
| Startup Time (Hot) | 5 min |
| Brand | OBLF |
|---|---|
| Origin | Germany |
| Model | OBLF GS1000 II |
| Instrument Type | Floor-standing |
| Excitation Method | Spark |
| Detector Type | Photomultiplier Tube (PMT) |
| Focal Length | 500 mm |
| Grating Groove Density | 2700 lines/mm |
| Wavelength Range | 120–780 nm |
| Number of Channels | 32 |
| Brand | Shimadzu |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Manufacturer |
| Regional Classification | Domestic |
| Model | PDA-5000 |
| Instrument Type | Floor-standing |
| Excitation Method | Spark |
| Detector Type | Photomultiplier Tube (PMT) |
| Focal Length | 600 mm |
| Grating Groove Density | 2400 lines/mm |
| Wavelength Range | 120–800 nm |
| Maximum Number of Channels | 24 |
| Brand | Shimadzu |
|---|---|
| Origin | Japan |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Instrument Type | Floor-Standing |
| Excitation Source | Spark |
| Detector Type | Photomultiplier Tube (PMT) |
| Focal Length | 600 mm |
| Groove Density | 2400 lines/mm |
| Wavelength Range | 120–800 nm |
| Maximum Channel Count | 64 |
| Brand | Shimadzu |
|---|---|
| Origin | Japan |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | PDA-8000 |
| Configuration | Floor-standing |
| Excitation Source | Spark Discharge |
| Detector Type | Photomultiplier Tube (PMT) |
| Focal Length | 1000 mm |
| Wavelength Range | 120–800 nm |
| Maximum Channel Count | 64 |
| Brand | SPECTRO |
|---|---|
| Origin | Germany |
| Model | SPECTRO M.01 |
| Instrument Type | Benchtop |
| Technology | Spark Optical Emission Spectrometry (OES) |
| Target Matrix | Ferrous Alloys |
| Compliance | ISO/IEC 17025 compatible, ASTM E415, ASTM E1086, EN 10315, DIN 51008 |
| Software | SPECTRO AnalyzeNet v3.x with ICAL 2.0 calibration technology |
| Gas Requirement | High-purity argon (≥99.996%) |
| Cooling | Air-cooled |
| Safety | CE, UL 61010-1 compliant |
| Data Management | Audit trail, user access levels, GLP/GMP-ready reporting |
| Brand | SPECTRO |
|---|---|
| Origin | Germany |
| Model | SPECTROLAB S LAS02 |
| Instrument Type | Floor-Standing |
| Excitation Source | Spark |
| Detector Type | CMOS+T Solid-State Array |
| Focal Length | 750 mm |
| Grating Groove Density | 3600 lines/mm |
| Wavelength Range | 120–800 nm |
| Number of Channels | Application-Defined |
| Brand | SPECTRO |
|---|---|
| Origin | Germany |
| Model | SPECTROMAXx (Desktop) |
| Instrument Type | Desktop |
| Excitation Method | Spark |
| Detector Type | CMOS |
| Focal Length | 400 mm |
| Grating Density | 3600 lines/mm |
| Wavelength Range | User-Configurable |
| Number of Channels | Application-Dependent |
| Brand | SPECTRO |
|---|---|
| Origin | Germany |
| Model | SPECTROMAXx (Floor-standing) |
| Instrument Type | Floor-standing |
| Excitation Method | Spark |
| Detector Type | CMOS |
| Focal Length | 400 mm |
| Grating Density | 3600 lines/mm |
| Wavelength Range | User-configurable |
| Number of Channels | Application-dependent |
| Compliance | ASTM E1184, ISO 11577, ISO 6871, EN 10052, USP <233>, FDA 21 CFR Part 11 (software-enabled), GLP/GMP-ready audit trail |
| Brand | SPECTRO |
|---|---|
| Origin | Germany |
| Model | SPECTROMAXx08 |
| Excitation Source | Spark |
| Detector Type | Charge-Coupled Device (CCD) |
| Focal Length | 400 mm |
| Grating Groove Density | 3600 lines/mm |
| Wavelength Range | User-configurable |
| Number of Channels | Not applicable (Full-spectrum CCD-based system) |
| Instrument Form Factor | Floor-standing |
| Application Domain | Metal & Foundry Quality Control, Incoming/Outgoing Material Inspection, Process Monitoring |
| Brand | SPECTRO |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Product Category | Imported Instrument |
| Model | SPECTROPORT |
| Instrument Type | Portable / Field-Deployable |
| Excitation Method | Spark Discharge |
| Detector Type | CCD (Charge-Coupled Device) |
| Focal Length | 300 mm |
| Grating Groove Density | 3600 lines/mm |
| Wavelength Range | 178–530 nm |
| Brand | SPECTRO |
|---|---|
| Origin | Germany |
| Instrument Type | Portable/Mobile |
| Excitation Method | Spark & Arc |
| Detector Type | CCD (Charge-Coupled Device) |
| Focal Length | 400 mm |
| Grating Groove Density | 3600 lines/mm |
| Wavelength Range | 174–670 nm |
| Number of Channels | Unlimited |
| Power Supply | Rechargeable Battery (up to 800 measurements per charge) |
| Brand | SPECTRO |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | SPECTRO TEST |
| Instrument Type | Portable/Mobile |
| Excitation Method | Spark & Arc |
| Detector Type | CCD (Charge-Coupled Device) |
| Focal Length | 400 mm |
| Grating Groove Density | 3600 lines/mm |
| Wavelength Range | 174–670 nm |
| Spectral Coverage | Full-Spectrum (Echelle + Prism Cross-Dispersion) |
| Price Range | USD 52,000–65,000 (FOB Hamburg) |
| Brand | SPECTRO |
|---|---|
| Origin | Germany |
| Model | SPECTROCHECK LMM02 |
| Instrument Type | Benchtop |
| Excitation Method | Spark |
| Detector Type | CMOS |
| Focal Length | 400 mm |