Dissolution Tester
Filter
Showing 1–30 of 51 results
| Brand | Agilent Technologies |
|---|---|
| Origin | Imported |
| Manufacturer Type | Manufacturer |
| Instrument Type | Offline Disintegration Tester |
| Sample Capacity | 3-Basket Configuration |
| Temperature Range | Ambient +5 °C to 55 °C |
| Temperature Accuracy | ±0.1 °C |
| Rotation Speed | 30 ±1 RPM |
| Water Bath Volume | 8 L |
| Brand | Agilent Technologies |
|---|---|
| Origin | Imported |
| Manufacturer Type | Manufacturer |
| Instrument Type | Offline Dissolution Tester |
| Model | 280-DS |
| Compliance | Supports eMQ and PVT per USP <711>, <724>, ASTM D6519, and FDA Guidance on Dissolution Equipment Verification |
| Brand | Agilent Technologies |
|---|---|
| Origin | Imported |
| Manufacturer Type | Manufacturer |
| Instrument Type | Offline Dissolution Tester |
| Vessel Capacity | 13 positions |
| Temperature Range | Ambient +5 °C to 55 °C |
| Temperature Accuracy | ±0.1 °C |
| Agitation Rate | 1–35 DPM (Dips Per Minute) |
| Brand | Agilent Technologies |
|---|---|
| Origin | Imported |
| Manufacturer Type | Manufacturer |
| Instrument Type | Online Dissolution Tester |
| Vessel Capacity | 8-position |
| Temperature Range | Ambient +5 °C to 55 °C |
| Temperature Accuracy | ±0.1 °C |
| Rotation Speed Range | 10–250 rpm |
| Bath Volume | 18 L |
| Brand | Agilent Technologies |
|---|---|
| Origin | Imported |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Instrument Type | Online Sampling System |
| Model | 850-DS |
| Compliance | Compatible with USP <711>, <724>, and ASTM D8239-22 |
| Pump Architecture | Integrated Rotary Piston Pump |
| Filtration | Optional 8-channel Whatman/Cytiva filter plate module |
| Sample Interface | Direct-to-HPLC vial tray (Agilent 1260/1290-compatible format) |
| Method Support | USP Apparatus 1 (Basket), 2 (Paddle), 3 (Reciprocating Cylinder), 5 (Paddle-over-Disk), 6 (Rotating Cylinder), and 7 (Reciprocating Holder) |
| Brand | Agilent Technologies |
|---|---|
| Origin | Imported |
| Manufacturer Type | Manufacturer |
| Instrument Type | Online Dissolution Tester |
| Vessel Configuration | 7-position or 12-position reciprocating rack |
| Temperature Range | Ambient +5 °C to 55 °C |
| Temperature Accuracy | ±0.1 °C |
| Stroke Rate | 5–40 cycles/min |
| Stroke Distance | 20 mm |
| Water Bath Volume | 25 L |
| Vessel Capacities Supported | 50 mL, 100 mL, 300 mL |
| Maximum Media Exchange Cycles | 6 per test |
| Unattended Operation Duration | Up to 144 hours (6 days) |
| Brand | Agilent Technologies |
|---|---|
| Origin | Imported |
| Manufacturer Type | Manufacturer |
| Instrument Type | Online Dissolution Tester |
| Vessel Capacity | 7-position |
| Temperature Range | Ambient +5 °C to 55 °C |
| Temperature Accuracy | ±0.1 °C |
| Stroke Rate | 5–60 DPM (Double Strokes per Minute) |
| Bath Volume | 25 L |
| Brand | Agilent Technologies |
|---|---|
| Origin | Malaysia |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported Instrument |
| Model Series | VK 7025, VK 7010, VK 705, BIO-DIS (3-Method & 7-Method), 705-DS |
| Instrument Type | Offline Dissolution Testing System |
| Regulatory Compliance | Fully compliant with USP <711>, EP 2.9.3, JP XVII, and ChP 0931 |
| Brand | ANDISSO |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Regional Classification | Domestic (China) |
| Model | D1200 PRO |
| Instrument Type | Online Sampling Dissolution System |
| Vessels | 12 |
| Temperature Range | Ambient to 50 °C |
| Temperature Accuracy | ±0.2 °C |
| Water Bath Volume | 46 L |
| Brand | ANDISSO |
|---|---|
| Origin | Shanghai, China |
| Model | D1200 |
| Instrument Type | Online Dissolution System |
| Vessel Capacity | 12 vessels |
| Temperature Range | Ambient to 50 °C |
| Temperature Accuracy | ±0.2 °C |
| Water Bath Volume | 46 L |
| Compliance | Chinese Pharmacopoeia 2020 Edition, General Chapter <0931> Dissolution and Release Testing |
| Brand | ANDISSO |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Regional Classification | Domestic (China) |
| Model | D1200 PRO Immersion Cell |
| Instrument Type | Online Dissolution Sampling System |
| Dissolution Vessels | 12-position |
| Temperature Range | Ambient to 50 °C |
| Temperature Accuracy | ±0.2 °C |
| Water Bath Volume | 46 L |
| Brand | ANDISSO |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | R3000 PRO |
| Instrument Type | Offline Dissolution System |
| Vessel Configuration | 7-position × 6-row cylinder rack |
| Temperature Range | Ambient to 50 °C |
| Temperature Accuracy | ±0.2 °C |
| Brand | ANDISSO |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | R7000 PRO |
| Instrument Type | Offline Sampling System |
| Vessel Configuration | 7-position × 6-row dissolution cups |
| Temperature Range | Ambient to 50 °C |
| Temperature Accuracy | ±0.2 °C |
| Number of dissolution vessels | 7 |
|---|---|
| Rotational speed range | 25–250 rpm |
| Speed resolution | 1 rpm |
| Speed accuracy | ±2% |
| Water bath temperature range | Ambient +5°C to 60°C |
| Temperature control accuracy | ±0.1°C |
| Maximum cumulative timing | 99 h 59 min |
| Number of programmable sampling intervals | 10 |
| Maximum interval duration | 9 h 59 min |
| Auto power-on/off timer range | 99 h 59 min |
| Power consumption | 1300 W |
| Input voltage | 220 V ±10%, 50 Hz |
| Dimensions (W×H×D) | 670 × 470 × 420 mm |
| Net weight | ~42 kg |
| Brand | Distek |
|---|---|
| Origin | USA |
| Model | Eclipse 5300 |
| Instrument Type | Online Sampling System |
| Sample Vessels | 6–8 vessels |
| Temperature Range | 20–65 °C |
| Temperature Accuracy | ±0.1 °C |
| Rotational Speed Range | 30–300 RPM |
| Paddle Wobble | ≤0.01 inch |
| Basket Wobble | ≤0.03 inch |
| Bath Temperature Control Range | 20–65 °C |
| Bath Temperature Resolution | 0.25 °C |
| Bath Volume | 18 L |
| Brand | Hanson |
|---|---|
| Origin | USA |
| Model | CD14 |
| Instrument Type | Offline Dissolution Tester |
| Vessel Capacity | 14 vessels |
| Temperature Range | 25.0–50.0 °C |
| Temperature Accuracy | ±0.1 °C (at 37 °C) |
| Rotational Speed Range | 25–250 rpm |
| Speed Accuracy | ±1 rpm |
| Display Resolution | 0.1 rpm |
| Compliance | USP <711>, <724>, EP 2.9.3, JP XVII, ChP, ASTM E2503, FDA Mechanical Calibration Guidance, 21 CFR Part 11 |
| Brand | Hanson |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | G2 Autoplus / G2 Autofill |
| Instrument Type | Online Integrated Sampler & Collector |
| Compliance | FDA 21 CFR Part 11, USP <711>, <724>, ISO 9001, CE, CSA, RoHS |
| Sampling Channels | 6 or 8 (Autoplus) |
| Sampling Accuracy | ±1% |
| Minimum Sampling Interval | 2 min (down to 1 min under controlled conditions) |
| Maximum Sample Points per Run | 50 |
| Syringe Volumes | 5 mL or 10 mL (inert fluid path) |
| Valve Configuration | 4-channel solenoid manifold (expandable to 16- or 24-position dissolution systems) |
| Control Interface | Full-color capacitive touchscreen |
| Program Storage | Up to 100 user-defined dissolution methods |
| Connectivity | USB 2.0, RS-232, Ethernet |
| Regulatory Features | Audit trail, electronic signatures, calibration/ maintenance prompts, solvent replenishment & auto-rinse protocols |
| Rack Compatibility | 16×100 mm UV cuvette racks, 12×32 mm HPLC vials, 12×32 mm UPLC vials, 6×8 multi-position trays |
| Integrated Filtration | In-line sterile-grade filtration module |
| Software Architecture | 32-bit embedded control firmware with deterministic real-time sampling logic |
| Brand | Hanson |
|---|---|
| Origin | USA |
| Model | Vision G2 Elite 8 / Vision G2 Classic 6 |
| Instrument Type | Offline Dissolution Tester |
| Number of Vessels | 6 or 8 |
| Temperature Range | 25–55 °C |
| Temperature Accuracy | ±0.2 °C |
| Temperature Resolution | 0.01 °C |
| Rotational Speed Range | 25–250 rpm |
| Speed Accuracy | ±1 rpm |
| Basket/Paddle Wobble | 0 mm |
| Bath Volume | 11.4 L (Classic 6) / 18.9 L (Elite 8) |
| Compliance | Fully compliant with 21 CFR Part 11 |
| Data Interface | RS232, USB, LAN |
| Onboard Storage | Up to 100 programmable dissolution methods |
| Power Supply | 220 V AC, 50–60 Hz, 65 W |
| Brand | LOGAN |
|---|---|
| Origin | USA |
| Model | AVC-100HTP |
| Type | Offline Cleaning System |
| Compliance | Designed for USP <711>, <724>, and FDA 21 CFR Part 11–aligned laboratory workflows |
| Brand | LOGAN |
|---|---|
| Origin | USA |
| Model | DISSOIII-7 |
| Instrument Type | Online Dissolution Tester |
| Vessel Configuration | 8 vessels/row × 6 rows OR 12 vessels/row × 12 rows |
| Temperature Range | 20–60°C |
| Temperature Accuracy | ±0.1°C |
| Water Bath Temperature Range | Ambient to 45°C |
| Water Bath Temperature Resolution | 0.1°C |
| Water Bath Volume | 28 L |
| Compliance | USP <711> (Method 3 & Method 7) |
| Data Integrity | FDA 21 CFR Part 11-compliant audit trail and three-tier user access control |
| Brand | LOGAN |
|---|---|
| Origin | USA |
| Model | PERMETRO 800 |
| Instrument Type | Offline Dissolution-Permeation System |
| Number of Vessels | 8 |
| Temperature Range | 20–60 °C |
| Temperature Accuracy | ±0.1 °C |
| Rotation Speed Range | 25–250 rpm (±1 rpm) |
| Paddle Wobble | ≤0.5 mm |
| Basket Wobble | ≤1.0 mm |
| Water Bath Temperature Range | Ambient to 45 °C |
| Water Bath Temperature Resolution | 0.1 °C |
| Water Bath Volume | 18 L |
| Brand | LOGAN |
|---|---|
| Origin | USA |
| Model | PERMETRO 800HPLC |
| Instrument Type | Online Coupled Dissolution-Permeation System |
| Number of Dissolution Vessels | 8 |
| Temperature Range (Bath & Chamber) | 20–60°C |
| Temperature Accuracy | ±0.1°C |
| Rotation Speed Range | 25–250 rpm (±1 rpm) |
| Paddle Wobble | ≤0.5 mm |
| Basket Wobble | ≤1.0 mm |
| Water Bath Temperature Range | Ambient to 45°C |
| Water Bath Temperature Resolution | 0.1°C |
| Water Bath Volume | 18 L |
| Brand | LOGAN |
|---|---|
| Origin | USA |
| Model | SYSTEM 4000 |
| Instrument Type | Online Flow-Through Dissolution System |
| Temperature Range | Ambient to 45 °C |
| Temperature Accuracy | ±0.1 °C |
| Flow Rate Control Modes | Constant Flow or Pulsed Flow (user-selectable) |
| Flow Cell Options | 12 mm, 22.6 mm, Powder Cell, Suppository Cell, Granule Cell |
| Number of Parallel Flow Channels | 8 |
| Bath Volume | 20 L |
| Bath Temperature Resolution | 0.1 °C |
| Shaft Wobble Tolerance (Paddle/Rotating Basket) | ≤1 mm |
| Motor Speed | 500 rpm (50 Hz), 600 rpm (60 Hz) |
| Compliance | Fully compliant with USP <4>, USP <711>, and FDA 21 CFR Part 11 requirements for audit trail, electronic signature, and data integrity |
| Brand | LOGAN |
|---|---|
| Origin | USA |
| Model | SYSTEM 850DL |
| Instrument Type | Online Dissolution Testing System |
| Dissolution Vessels | 8-position |
| Temperature Range | 20–60°C |
| Temperature Accuracy | ±0.1°C |
| Rotation Speed Range | 25–250 rpm (±1 rpm) |
| Paddle Wobble | ≤0.5 mm |
| Basket Wobble | ≤1.0 mm |
| Water Bath Temperature Control Range | Ambient to 45°C |
| Water Bath Temperature Resolution | 0.1°C |
| Water Bath Volume | 18 L |
| Brand | LOGAN |
|---|---|
| Origin | USA |
| Model | SYSTEM 850DL-12 |
| Instrument Type | Online Dissolution Tester |
| Vessel Positions | 8 or 12 |
| Temperature Range | Ambient to 45 °C ±0.1 °C |
| Rotation Speed Range | 25–250 rpm ±0.1 rpm |
| Pump Configuration | 12-channel syringe pump (12 × 10 mL) |
| Compliance | USP <711>, <724>, <723>, <725>, <731> |
| Integrated Modules | UDT-812A-12 dissolution apparatus, SCR-160L sample collector, SYP-6L 12-channel syringe pump, DSC-800D sampling controller |
| Brand | LOGAN |
|---|---|
| Origin | USA |
| Model | SYSTEM 850DLA |
| Instrument Type | Online Dissolution System |
| Number of Vessels | 8 |
| Temperature Range | 20–60 °C |
| Temperature Accuracy | ±0.1 °C |
| Rotation Speed Range | 25–250 rpm (±1 rpm) |
| Paddle Wobble Amplitude | ≤0.5 mm |
| Basket Wobble Amplitude | ≤1.0 mm |
| Water Bath Temperature Range | Ambient to 45 °C |
| Water Bath Temperature Resolution | 0.1 °C |
| Water Bath Volume | 18 L |
| Brand | LOGAN |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | SYSTEM 860CDL |
| Instrument Type | Online Dissolution System |
| Dissolution Vessels | 12 |
| Temperature Range | 20–60 °C |
| Temperature Accuracy | ±0.1 °C |
| Rotation Speed Range | 25–250 rpm (±1 rpm) |
| Paddle Wobble Amplitude | ≤0.5 mm |
| Basket Wobble Amplitude | ≤1.0 mm |
| Water Bath Temperature Range | Ambient to 45 °C |
| Water Bath Temperature Resolution | 0.1 °C |
| Water Bath Volume | 30 L |
| Brand | LOGAN |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | SYSTEM 860DL |
| Instrument Type | Online Dissolution System |
| Number of Vessels | 12 |
| Temperature Range | 20–60 °C |
| Temperature Accuracy | ±0.1 °C |
| Rotational Speed Range | 25–250 rpm (±1 rpm) |
| Paddle Wobble Amplitude | ≤0.5 mm |
| Basket Wobble Amplitude | ≤1.0 mm |
| Water Bath Temperature Control Range | Ambient to 45 °C |
| Water Bath Temperature Resolution | 0.1 °C |
| Water Bath Volume | 30 L |
| Compliance | FDA 21 CFR Part 11, GLP/GMP-ready audit trail and role-based access control |
| Brand | LOGAN |
|---|---|
| Origin | USA |
| Model | SYSTEM 860DLA |
| Instrument Type | Online Dissolution Sampling System |
| Vessel Capacity | 12-position |
| Compliance | FDA 21 CFR Part 11 (Audit Trail, Electronic Signatures, Role-Based Access Control) |
| Modular Configuration | UDT-818A Dissolution Apparatus, SCR-DL Sample Collector, SYP-12L-10mL Precision Syringe Pump, DSC-800 System Controller |
| Temperature Monitoring | 12 independent RTD probes per vessel |
| Filtration | Dual-stage inline filtration (pre- and post-sampling) |
| Fluid Handling | Auto-replenishment, isothermal media replacement, sample filtration, and volume compensation |
| Integration Capabilities | UV/Vis spectrophotometers, HPLC autosamplers, fiber-optic probes, dilution modules, and permeation systems (e.g., PAMPA, Caco-2) |
| Brand | LOGAN |
|---|---|
| Origin | USA |
| Model | SYSTEM ADIS 1200 |
| Instrument Type | Online Dissolution Analyzer |
| Configuration | 12-Position Fully Automated System |
| Compliance | Designed for USP <711>, <724>, <1092>, and FDA Guidance on Dissolution Testing |