Electrochemical Workstation
Filter
Showing 61–90 of 108 results
| Brand | Metrohm |
|---|---|
| Origin | Netherlands |
| Manufacturer | Metrohm Autolab |
| Type | Electrochemical Workstation |
| Model | VIONIC |
| Current Range | ±6 A |
| Current Accuracy | ±0.2% |
| Potential Accuracy | ±0.2% |
| Potentiostatic Range | ±10 V |
| Galvanostatic Range | ±6 A |
| EIS Frequency Range | 10 µHz – 10 MHz |
| Compliance Voltage | ±50 V |
| Minimum Sampling Interval | 1 µs |
| Floating Mode | Optional |
| Dual Reference Electrode Support (S2) | Yes |
| Electrochemical Cell Isolation | Yes |
| Oscillation Protection | Yes |
| Independent Cell Switch | Yes |
| Brand | Teledyne Princeton Instruments |
|---|---|
| Origin | UK |
| Model | Modulab XM PhotoEchem |
| Instrument Type | Electrochemical Workstation |
| Current Range | ±300 mA |
| Current Accuracy | 0.1% reading + 0.05% range + 30 fA |
| Potential Accuracy | 0.1% reading + 0.05% range + 100 µV |
| Potentiostatic Range | ±8 V |
| AC Impedance Frequency Range | 10 µHz – 1 MHz |
| Brand | PalmSens |
|---|---|
| Origin | Netherlands |
| Model | PalmSens 4 |
| Instrument Type | Portable Electrochemical Workstation |
| Channel Count | Single-Channel |
| Current Range | 100 pA to 10 mA (9 ranges) |
| Current Accuracy | ≤ 0.1 % of Full-Scale Reading (FSR) |
| Potential Accuracy | ≤ 0.1 % of FSR |
| Potentiostatic Range | ±10.000 V |
| EIS Frequency Range | 10 µHz to 1 MHz |
| Brand | Metrohm Autolab |
|---|---|
| Origin | Netherlands |
| Manufacturer | Metrohm Autolab B.V. |
| Type | Single-Channel Potentiostat/Galvanostat |
| Max Current Output | ±100 mA |
| Current Range | 10 nA – 10 mA (7 decades) |
| Current Resolution | 30 fA (at 10 nA range) |
| Current Accuracy | ±0.2% of reading ± 0.2% of range |
| Potential Range | ±10 V |
| Applied Potential Accuracy | ±2 mV ± 0.2% of setting |
| Potential Resolution | 150 µV (applied), 3–300 µV (measured, selectable) |
| Potentiostat Bandwidth | 1 MHz |
| Rise/Fall Time (1 V step, 10–90%) | < 250 ns |
| Input Impedance | > 100 GΩ |
| Bias Current (25°C) | < 1 pA |
| Coulometric Integrator | Built-in, hardware-based |
| iR Compensation | Positive feedback and current-interrupt modes |
| Electrode Configuration | 2-, 3-, or 4-electrode |
| Analog I/O | 16-bit DAC/ADC, programmable voltage/current control and monitoring |
| Software | NOVA 2.1+ (Windows only) |
| Compliance | CE, RoHS, ISO 9001 certified design |
| Data Integrity | Audit-trail enabled in NOVA for GLP/GMP environments |
| Brand | POWEREACH |
|---|---|
| Origin | Shanghai, China |
| Model | FJ3003 |
| Instrument Type | Single-Channel Electrochemical Workstation |
| Analog Input Channels | 2 (auto-ranging: ±0.2 V, ±2 V, ±20 V) |
| Input Impedance | >10 MΩ |
| Sampling Rate | 100 MS/s |
| Display & Measurement Resolution | 4 significant digits |
| Temperature Measurement Accuracy | ±0.01 °C |
| Temperature Control Range | 15 °C above ambient to 100 °C |
| Temperature Setpoint Range | 0–100 °C |
| Temperature Control Accuracy | ±0.1 °C |
| Temperature Output Actuation | Zero-crossing triggered thyristor |
| Control Output | 5-step power output (max. 300 W) |
| Electrical Isolation | Analog-to-digital and overvoltage protection integrated |
| Compliance | Designed for academic lab environments |
| Brand | POWEREACH |
|---|---|
| Origin | Shanghai, China |
| Model | JH11X |
| Instrument Type | Single-Channel Electrochemical Workstation |
| Potentiostatic Range | ±2 V |
| Current Range | ±2 mA / ±20 mA (dual-range) |
| Potential Resolution | 0.001 V |
| Current Resolution | 0.001 mA |
| Reference Electrode Input Impedance | ≥10¹² Ω |
| Cell Voltage Range | ±13 V |
| Power Supply | AC 220 V, 50 Hz |
| Dimensions | 320 × 215 × 130 mm |
| Brand | Princeton Applied Research |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model | PAR STAT MC |
| Instrument Type | Electrochemical Workstation |
| Current Range | 4 nA – 2 A |
| Current Accuracy | ±0.2% of full scale |
| Potential Accuracy | ±0.2% of full scale |
| Potentiostatic Range | ±30 V |
| EIS Frequency Range | 10 µHz – 7 MHz |
| [Brand | Princeton Applied Research |
|---|---|
| Origin | USA |
| Model | PAR 273A |
| Maximum Output Voltage | >±100 V |
| Maximum Output Current | >±1.0 A |
| Slew Rate | 10 V/µs |
| Open-Loop Bandwidth (Unity Gain) | >2.5 MHz |
| Electrometer Input Impedance | >10¹² Ω |
| Input Bias Current | <20 pA at 25°C |
| Differential Input Range | ±10 V |
| Reference Input Range | ±11 V |
| Small-Signal Bandwidth | >8 MHz |
| Full-Signal Bandwidth | >400 kHz |
| IR Compensation Range | 2 Ω to 20 MΩ |
| Current Ranges | 1 A to 100 nA (8 decades) |
| Current Measurement Accuracy | 0.2% (10 µA–1 A), 0.5% (100 nA–1 µA) |
| Potentiostatic Control Resolution | 14-bit DAC, ±8 V range |
| Galvanostatic Control Resolution | 14-bit DAC, ±200% of full scale |
| Rise Time (High-Speed Mode) | <750 ns (no load), <3 µs (1 Ω, 1 A) |
| Noise | <25 µV rms (with external input) |
| Interfaces | RS-232C, IEEE-488 (GPIB) |
| Dimensions | 48 cm W × 30 cm H × 51 cm D |
| Weight | 31 kg |
| Power | 100–260 V AC, 50–60 Hz, max 350 W] |
| Brand | Princeton Applied Research |
|---|---|
| Origin | USA |
| Model | PARSTAT 2273 |
| Instrument Type | Electrochemical Workstation |
| Current Range | ±40 pA to ±2 A (optional ±20 A) |
| Current Resolution | 1.2 fA |
| Current Accuracy | <0.4% of reading (for 20 µA–2 A range) |
| Potential Accuracy | ±0.2% of value ± 2 mV |
| Potentiostatic Range | ±10 V |
| Galvanostatic Range | ±2 A (extendable) |
| Cell Voltage Compliance | ±100 V |
| EIS Frequency Range | 10 µHz to 1 MHz |
| Input Impedance | >10¹³ Ω |
| Electrometer Bandwidth | >15 MHz (–3 dB) |
| Minimum Time Base | 20 µs |
| Minimum Potential Step | 2.5 µV |
| iR Compensation | Positive feedback (2 Ω to 2000 MΩ) |
| Interface | USB |
| Weight | 31 kg |
| Dimensions | 50.8 cm W × 47.6 cm H × 22.9 cm D |
| Power Supply | 90–260 V AC, 50–60 Hz, max. 600 W |
| Brand | Princeton Applied Research |
|---|---|
| Origin | USA |
| Model | PARSTAT 3000A DX |
| Instrument Type | Benchtop Dual-Channel Electrochemical Workstation |
| Current Range | ±1 A to ±4 nA (auto-ranging, 10 decades) |
| Current Resolution | 122 fA (at 4 nA range) |
| Current Accuracy | ±0.2% of reading + ±0.2% of range + ±200 pA (DC, 20 nA–1 A) |
| Potential Range | ±30 V / ±6 V |
| Potential Resolution | 5 µV (applied), 46 µV (measured) |
| Potential Accuracy | ±0.2% of reading + ±2 mV |
| EIS Frequency Range | 10 µHz – 7 MHz |
| Potentiostat Bandwidth | 7 MHz |
| Slew Rate | >35 V/µs |
| Rise Time (−1 V to +1 V) | <56 ns |
| Electrometer Input Impedance | ≥10¹² Ω |
| Electrometer Bandwidth | ≥10 MHz (−3 dB) |
| CMRR | >70 dB @ 300 kHz |
| Data Acquisition | 4 × 18-bit ADC, 1 MS/s synchronous (potential, current, auxiliary voltage) |
| Time Resolution | 1 µs |
| iR Compensation | Positive feedback & dynamic iR compensation |
| Compliance | CE certified, compliant with IEC 61010-1 for laboratory equipment |
| Operating Environment | 10–35 °C, ≤80% RH non-condensing |
| Brand | Princeton Applied Research |
|---|---|
| Origin | USA |
| Model | PARSTAT 3000A |
| Instrument Type | Single-Channel Electrochemical Workstation |
| Current Range | ±1 A |
| Current Accuracy | ±0.2% |
| Potential Accuracy | 0.2% ± 2 mV |
| Potentiostatic Range | ±30 V |
| EIS Frequency Range | 10 µHz – 7 MHz |
| Brand | Princeton Applied Research |
|---|---|
| Origin | USA |
| Model | P3000A |
| Channel Configuration | Single-Channel |
| Current Range | ±1 A |
| Current Accuracy | ±0.2% of reading |
| Potential Accuracy | ±0.2% of reading |
| Potentiostatic Range | ±30 V |
| EIS Frequency Range | 10 µHz to 10 MHz |
| Brand | Princeton Applied Research |
|---|---|
| Origin | USA |
| Model | PARSTAT 4000A |
| Channel Count | Single-Channel |
| Current Range | ±4 A (expandable to ±20 A) |
| Current Resolution | 1.2 fA (standard), 2.5 aA (with low-current option) |
| Current Accuracy | ±0.2% of reading + ±0.2% of range |
| Potential Accuracy | ±0.2% of value ± 2 mV |
| Potentiostatic Range | ±10 V |
| Galvanostatic Range | ±4 A |
| Compliance Voltage | ±48 V |
| EIS Frequency Range | 10 µHz – 10 MHz |
| Sampling Rate | 1 µs |
| Onboard Memory | 4 MB |
| Input Impedance | >10¹³ Ω |
| Grounding Mode | Floating (isolated ground) |
| Brand | Princeton Applied Research |
|---|---|
| Origin | USA |
| Model | PMC2000 / PMC1000 / PMC500 |
| Instrument Type | Electrochemical Workstation |
| Current Range | 4 nA – 2 A |
| Current Accuracy | ±0.2% of reading, ±0.2% of range (down to 4 nA) |
| Potential Accuracy | ±0.2% of reading, ±2 mV |
| Potentiostatic Range | ±30 V |
| EIS Frequency Range | 10 µHz – 7 MHz |
| Data Acquisition Rate | up to 500 kS/s (per channel), 1 MS/s (burst mode) |
| Auxiliary Voltage Measurement | 6-wire remote sensing |
| Channel Capacity | Up to 8 independent, hot-swappable channels per mainframe |
| Brand | Princeton Applied Research |
|---|---|
| Origin | USA |
| Model | PMC2000 / PMC1000 / PMC200 |
| Instrument Type | Multi-Channel Electrochemical Workstation |
| Number of Channels | Up to 8 independent, hot-swappable channels per mainframe |
| Current Range | ±2 A |
| Current Accuracy | ±0.2% |
| Potential Accuracy | ±0.2% |
| Potentiostatic Range | ±30 V |
| EIS Frequency Range | 10 MHz to 10 µHz |
| Data Acquisition Rate | up to 500 kS/s (per channel) |
| Auxiliary Voltage Input | 6-wire Kelvin sensing |
| Resolution (PMC1000) | 120 fA |
| Impedance Scan Range | 10 µHz – 7 MHz (with PMC2000 module) |
| Floating Ground Architecture | Standard |
| Brand | Princeton Applied Research |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported Instrument |
| Model | PMC-1000 AT |
| Instrument Type | Electrochemical Workstation |
| Channel Architecture | Modular Multi-Channel (Up to 3 Slots) |
| Current Range | ±2 A to ±2 nA |
| Current Accuracy | ±0.2% of reading |
| Potential Accuracy | ±0.2% of full scale |
| Potentiostatic Range | ±10 V |
| Galvanostatic Range | ±2 A (expandable to ±20 A internal / ±30 A external) |
| EIS Frequency Range | 10 µHz – 1 MHz |
| Voltage Resolution | 150 nV (24-bit ADC) |
| Current Resolution | 30 fA (24-bit ADC) |
| Low-Current Extension (LCI) | 122 aA |
| Analog Inputs | 2 (including thermistor interface) |
| Analog Outputs | 2 |
| Digital I/O | 1 input, 4 outputs |
| Communication | Ethernet-based modular chassis architecture |
| Electrode Connections | CE, WE, RE, SE + dual auxiliary voltage dividers (8-wire configuration) |
| Supported Techniques | CV, LSV, SSLV, CA, CP, CC, CR, LPR, Tafel, PEIS, GEIS, SWV, DPV, FP, Arbitrary Waveform, iR Compensation, Ohmic Drop Correction, Looping & Variable Parameter Sequencing |
| Brand | Princeton Applied Research |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | VersaSCAN |
| Instrument Type | Electrochemical Workstation |
| Channel Count | Single-Channel |
| Current Range | ±2 A |
| Current Accuracy | ±0.2% |
| Potential Accuracy | ±0.2% |
| Potentiostatic Range | ±10 V |
| EIS Frequency Range | 10 µHz – 1 MHz |
| Brand | Princeton Applied Research |
|---|---|
| Origin | United Kingdom |
| Distributor Type | General Distributor |
| Import Status | Imported |
| Model | VersaScan |
| Instrument Type | Electrochemical Workstation |
| Current Range | 4 nA – 2 A |
| Current Accuracy | ±0.2% of reading |
| Potential Accuracy | ±0.2% of reading ± 2 mV |
| Potentiostatic Range | ±10 V |
| EIS Frequency Range | 10 µHz – 1 MHz |
| Brand | Solartron Analytical |
|---|---|
| Origin | United Kingdom |
| Model | 1260A |
| Channel Count | Single-Channel Workstation |
| Current Range | 200 nA – 2 A |
| Current Accuracy | ±0.2% of reading + ±1% of full scale |
| Potential Accuracy | ±0.2% of reading + ±10 mV |
| Potentiostatic Range | ±14.5 V (when coupled with 1287) / ±40.95 V (1260A standalone) |
| AC Impedance Frequency Range | 10 µHz – 32 MHz |
| Voltage/Current Resolution | 1 µV / 1 pA |
| Frequency Resolution | 0.015 ppm |
| Phase Accuracy | ±0.1° |
| Magnitude Accuracy | ±0.1 dB |
| Electrode Configurations | 2-, 3-, and 4-terminal |
| Active Shielding | Yes |
| Floating Measurement Capability | Yes |
| Software | CorrWare & ZPlot v3.x |
| Brand | Solartron Analytical |
|---|---|
| Origin | United Kingdom |
| Model | 1260A |
| Instrument Type | Multi-Channel Electrochemical Workstation |
| Current Range | ±60 mA |
| Current Accuracy | ±0.2% of reading |
| Potential Accuracy | ±0.2% of reading |
| Potentiostatic Range | ±40.95 V |
| AC Impedance Frequency Range | 10 µHz – 32 MHz |
| Phase Accuracy | ±0.1° |
| Magnitude Accuracy | ±0.1% |
| Frequency Resolution | 0.015 ppm |
| Core Technology | Single-Sine Correlation Method |
| Brand | Solartron Analytical |
|---|---|
| Origin | United Kingdom |
| Model | 1455 / 1451 |
| Frequency Range | 10 Hz – 1 MHz (1455), 10 Hz – 100 kHz (1451) |
| Frequency Resolution | 1 / 65,000,000 |
| DAC Sampling Rate | 40 MHz |
| Accuracy | ±0.1% magnitude, ±0.1° phase |
| Phase Resolution | 0.01° |
| RMS Signal Amplitude | 3 V – 50 V |
| Waveform Options | Single-sine, multi-sine (FFT-based) |
| Input/Output Interface | Ethernet per module |
| Expandable Channels | 1–8 independent FRA units per system |
| Auxiliary Voltage Analyzer Ports | 4 (requires 14702A/14703A option with 1470E) |
| Brand | Solartron Analytical |
|---|---|
| Origin | United Kingdom |
| Model Series | 1470E |
| Current Range | ±4 A |
| Current Accuracy | ±0.1% of full scale |
| Potential Accuracy | ±0.1% of full scale |
| Potentiostatic Range | −3 V to +10 V |
| EIS Frequency Range | 10 µHz to 1 MHz |
| Brand | Solartron Analytical |
|---|---|
| Origin | United Kingdom |
| Model | 1470E Series |
| Channel Count | Up to 8 independent channels per unit |
| Current Range | ±4 A |
| Current Accuracy | ±0.2% of reading |
| Potential Accuracy | ±0.2% of reading |
| Potentiostatic Range | ±10 V |
| EIS Frequency Range | 10 µHz – 1 MHz |
| Control Interface | Ethernet |
| Compliance | ASTM G102, ISO 17475, IEC 62660-2, USP <1058>, FDA 21 CFR Part 11 (software audit trail enabled) |
| Safety | Per-channel hardware-based voltage/current limit enforcement, fast-acting termination logic (<100 µs response) |
| Brand | Solartron Analytical |
|---|---|
| Origin | USA |
| Model | 9300R-SA |
| Instrument Type | Multi-Channel Electrochemical Workstation |
| Channel Count | 1–4 Configurable Channels |
| DC Current Range | ±200 A (300 A Pulse), Up to ±800 A with 4-Channel Parallel Operation |
| DC Current Accuracy | ±0.02 % of Reading |
| Potential Accuracy | ±30 µV |
| Potentiostatic Range | +300 mV to +10 V |
| EIS Frequency Range | 1 mHz to 10 kHz |
| Voltage Resolution | 20 µV (24-bit ADC) |
| Current Resolution | 2 µA (24-bit ADC) |
| DC Sampling Rate | 1 kS/s |
| Auxiliary Voltage Divider Inputs | 2 (for DC/EIS) |
| Temperature Monitoring | Optional External 16-Channel Synchronized Acquisition |
| Power Supply | 3-Phase 380 V, 5.5–11 kW |
| Brand | Solartron Analytical |
|---|---|
| Origin | United Kingdom |
| Model | Energylab XM |
| Channel Count | Single-Channel |
| Current Range | ±2 A |
| Current Accuracy | 0.1% + 0.05% + 30 fA |
| Potential Accuracy | 0.1% + 0.05% + 100 µV |
| Potentiostatic Range | ±8 V |
| EIS Frequency Range | 10 µHz – 1 MHz |
| Impedance Measurement Limit | <100 µΩ (with external amplifier support up to 100 A) |
| Sampling Rate | Up to 1 MS/s (DC), 40 MS/s (FRA) |
| Auxiliary Differential Inputs | 4-channel synchronized with RE |
| Brand | Solartron Analytical |
|---|---|
| Origin | United Kingdom |
| Model | Energylab XM |
| Channel Count | Single-Channel |
| Current Range | ±2 A |
| Current Accuracy | ±0.2% |
| Potential Accuracy | ±0.2% |
| Potentiostatic Range | ±8 V |
| EIS Frequency Range | 10 µHz – 1 MHz |
| Low-Impedance Measurement Capability | Down to 10 µΩ |
| Current Resolution | 100 aA |
| Voltage Resolution | 1 µV |
| Sampling Rate | Up to 1 MS/s (DC), 40 MS/s (FRA) |
| Auxiliary Differential Inputs | 4-channel |
| Compliance | ASTM G5, G59, G102 |
| Brand | Solartron Analytical |
|---|---|
| Origin | UK |
| Model | HV 9250 |
| Channel Configuration | Multi-channel (1 or 2 main channels + up to 5 auxiliary voltage divider channels) |
| Current Range | ±125 A to ±250 A |
| Current Accuracy | ±0.1% |
| Potential Accuracy | ±0.1% |
| Potentiostatic Range | ±60 V, ±120 V, ±240 V |
| EIS Frequency Range | 1 mHz – 10 kHz |
| Maximum Power per Main Channel | 10 kW |
| Data Acquisition Rate | 10 kS/s |
| ADC Resolution | 24-bit (120 µV main channel, 20 µV auxiliary) |
| Input Impedance | 10 MΩ (all voltage inputs) |
| Temperature Inputs | 6 thermistor channels (1 per main + 5 auxiliary), 16 thermocouple channels via external VTI1401 DAQ |
| Digital I/O | 1 input, 1 output (trigger/control) |
| Software Platform | Aspire™ electrochemical control and analysis suite |
| Brand | Solartron Analytical |
|---|---|
| Origin | United Kingdom |
| Model | Modulab XM DSSC |
| Current Range | ±2 A |
| Current Accuracy | 0.1% reading + 0.05% range + 30 fA |
| Potential Accuracy | 0.1% reading + 0.05% range + 100 µV |
| Potentiostatic Range | ±100 V |
| EIS Frequency Range | 10 µHz – 1 MHz |
| Compliance | NIST-traceable light source calibration |
| Software Platform | ModuLab XM Control & Analysis Suite |
| Upgrade Path | Compatible with legacy Modulab and Modulab XM hardware modules |
| Brand | Solartron Analytical |
|---|---|
| Origin | UK |
| Model | Modulab XM ECS |
| Current Range | ±2 A |
| Current Accuracy | 0.1% reading + 0.05% range + 30 fA |
| Potential Accuracy | 0.1% reading + 0.05% range + 100 µV |
| Potentiostatic Range | ±100 V |
| EIS Frequency Range | 10 µHz – 1 MHz |
| Brand | Solartron Analytical |
|---|---|
| Origin | United Kingdom |
| Model | ModuLab XM MTS (1296A + 1294A) |
| Current Range | ±2 A |
| Current Accuracy | 0.1% reading + 0.05% range + 30 fA |
| Potential Accuracy | ±0.2% of setting |
| Potentiostatic Range | ±100 V |
| AC Impedance Frequency Range | 10 µHz – 1 MHz |
| Impedance Measurement Range | 100 Ω – 100 TΩ (12 decades) |
| Dielectric Loss Tangent Resolution | tan δ < 10⁻⁴ |
| Max DC Bias Voltage | 1000 V (with external high-voltage source or amplifier) |
| Compliance | IEC 601 for biomedical applications (1294A), ASTM D257, ISO 3001, IEEE Std 930 |