Electrophysiology Instrument
Filter
Showing 31–47 of 47 results
| Brand | MappingLab |
|---|---|
| Origin | Beijing, China |
| Model | SG-WH012 |
| Instrument Type | Manual |
| Temperature Control Range | Ambient to 100 °C |
| Flow Rate Range | 0.02–380 mL/min |
| Pump Speed Range | 0.1–100 rpm (bidirectional adjustable) |
| Temperature Accuracy | ±0.5 °C |
| Water Bath Dimensions | 390 × 330 × 180 mm |
| Perfusion Chamber Volume | 200 mL / 500 mL |
| Return Reservoir Volume | 100 mL / 200 mL |
| Speed Resolution | 0.1 rpm |
| Peristaltic Pump Dimensions | 232 × 142 × 149 mm |
| Operating Environment | 0–40 °C, RH < 80% |
| Ingress Protection Rating | IP31 |
| Brand | MappingLab |
|---|---|
| Model | VCS-3002 |
| Output Modes | Constant Voltage & Constant Current |
| Voltage Range | ±90 V |
| Current Range | ±32 mA |
| Voltage Accuracy | ±0.1 V |
| Current Accuracy | ±20 µA |
| Max Output Frequency | 30 kHz |
| Pulse Duration Stability | Up to 200 h continuous operation |
| Isolation | Built-in galvanic isolation (no external isolator required) |
| I/O Interface | TTL-triggered stimulation, analog/digital I/O connectors |
| Protection | Integrated overcurrent and overvoltage protection |
| Brand | Multi Channel Systems |
|---|---|
| Origin | Germany |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | MEA2100-mini |
| Instrument Type | Single-Well Format |
| Application Scope | In Vitro Electrophysiological Recording & Stimulation |
| Electrode Pitch | 200 µm |
| Electrode Diameter | 30 µm |
| Electrode Layout | 8×8 (60 active + 4 ground/ reference electrodes, or 120-channel variant) |
| Physical Dimensions | 186 × 80 × 12 mm |
| Amplifier Resolution | 24-bit |
| Max Sampling Rate per Channel | 50 kHz |
| Stimulator Modes | Current Source (±1 mA), Voltage Source (±10 V) |
| Signal Acquisition Units per MCS-IFB Interface Board | Up to 2 |
| Probes per Acquisition Unit | Up to 4 |
| Integrated On-Probe Electronics | Amplification, Stimulation, and ADC |
| Operating Environment | Standard CO₂ incubators (37 °C, 5% CO₂, humidified) |
| Brand | Multi Channel Systems |
|---|---|
| Origin | Germany |
| Manufacturer | Multi Channel Systems GmbH |
| Model | Roboocyte2 |
| Detection Principle | Two-Electrode Voltage Clamp (TEVC) |
| Instrument Type | Fully Automated High-Throughput Electrophysiology Platform |
| Cell Type | Xenopus laevis oocytes |
| Seal Resistance | >1 GΩ |
| Throughput Format | 96-well plate |
| Amplifier Architecture | Integrated High-Stability TEVC Amplifier |
| Liquid Handling Compatibility | RoboFlow or Gilson Pipetting Systems (Optional) |
| Brand | Backyard Brains |
|---|---|
| Origin | USA |
| Model | Muscle SpikerBox |
| Type | DIY Electrophysiology Kit for EMG Recording |
| Compliance | CE, RoHS |
| Intended Use | Educational and Research-Level Surface Electromyography (sEMG) Signal Acquisition |
| Brand | Backyard Brains |
|---|---|
| Origin | USA |
| Model | Muscle SpikerShield Bundle |
| Includes | Pre-assembled SpikerShield board, Arduino Uno (preloaded with EMG demo firmware), USB cable, 6× adhesive EMG electrodes, 1× adjustable wooden electrode stand, 1× bottle of conductive electrode gel, 1× orange recording electrode wire with alligator clips (2× red, 1× black), 1× brass rod-style electrodes for small-muscle recording |
| Compliance | CE, FCC, RoHS compliant |
| Software | Open-source Arduino IDE-compatible firmware, Python-based data visualization examples available via Backyard Brains GitHub repository |
| Target Platform | Arduino Uno R3 compatible |
| Input Signal Type | Bipolar surface electromyography (sEMG) |
| Sampling Resolution | 10-bit ADC (default), upgradable to 12-bit via firmware modification |
| Operating Voltage | 5 V DC (USB-powered) |
| Bandwidth | 10–450 Hz (analog signal path), configurable digital filtering in firmware |
| Brand | Narishige |
|---|---|
| Origin | Japan |
| Model | EG-45 |
| Movement Range (X-Y) | 0.47 mm |
| Motor Speed | 150–2,100 rpm |
| Power Supply | AC 100–240 V (±5%), 50/60 Hz |
| Power Consumption | ~10 W |
| Dimensions | 185 × 165 × 310 mm |
| Weight | 2.4 kg |
| Compatible Capillary O.D. | 1.0–1.5 mm |
| Vertical Adjustment Range | 0.47 mm |
| Included Accessories | Pipette Holder, Vertical Grinding Adapter, Diamond Grinding Wheel, Cleaning Brush, Hex Key, Power Cord |
| Brand | Backyard Brains |
|---|---|
| Origin | USA |
| Model | Neuron SpikerBox Bundle |
| Type | Portable Bioamplifier System for Extracellular Neural Recording and Electrical Stimulation |
| Compliance | CE, FCC, RoHS |
| Software | SpikeRecorder (iOS/Android/macOS/Windows), Open-Source Python SDK Available |
| Battery | 9V alkaline (included) |
| Input Impedance | >100 MΩ |
| Gain | 1,000× (fixed) |
| Bandpass Filter | 100 Hz – 3 kHz |
| Sampling Rate | Up to 48 kHz (via USB or audio jack interface) |
| Electrode Interface | Standard 3.5 mm mono audio jack + alligator clip leads |
| Stimulus Output | Biphasic, current-limited (≤2 mA peak), programmable pulse width (0.1–10 ms) and frequency (1–100 Hz) |
| Brand | Backyard Brains |
|---|---|
| Origin | USA |
| Model | Neuron SpikerBox Pro |
| Sampling Rate | 10 kS/s (2-channel) |
| Frequency Range | 220–3100 Hz |
| Max Sound Pressure Level | 104 dB SPL |
| Neuronal Signal SNR | 30 dB |
| Battery Life | 4 h (full-volume audio mode), 18 h (recording-only mode) |
| Outputs | USB Micro-B, 3.5 mm headphone jack, smartphone audio interface, 2 analog outputs |
| Inputs | 2 × neuron recording leads, 5 × digital inputs OR 3 × digital inputs + 2 × analog inputs |
| Electrical Safety Classification | Type BF (floating body) |
| Brand | Raymetech |
|---|---|
| Origin | Jiangsu, China |
| Model | MMS-200 |
| Type | Motorized, Closed-Loop Electrophysiology Micromanipulator |
| Drive Mechanism | Piezo-assisted Stepper Motor Actuation |
| Positioning Resolution | ≤50 nm (open-loop), ≤100 nm (closed-loop with integrated capacitive feedback) |
| Repeatability | ±0.1 µm |
| Maximum Load Capacity | 200 g per axis |
| Travel Range (X/Y/Z) | 25 mm × 25 mm × 20 mm |
| Control Interface | USB 2.0 + RS-422 |
| Compatibility | Standard Nikon, Olympus, Leica, and Zeiss inverted & upright microscope stages |
| Software Platform | RayControl v3.2 (Windows 10/11, 64-bit) with FDA 21 CFR Part 11–compliant audit trail module |
| Brand | Santiyiqi |
|---|---|
| Model | ST-DW1 |
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Power Supply | AC 110–240 V, 50–60 Hz |
| Dimensions | 310 × 226 × 233 mm |
| Weight | 3.7 kg |
| Touchscreen | 7-inch Android 10 interface |
| Data Storage | Up to 100,000 records |
| Connectivity | USB, Wi-Fi, Ethernet |
| Titration Accuracy | ≤1.5% |
| Repeatability | ≤0.2% |
| 10 mL Burette Capacity Accuracy | ±5 µL |
| 20 mL Burette Capacity Accuracy | ±10 µL |
| Potential Range | −2000 to +2000 mV |
| Potential Resolution | 0.1 mV |
| Potential Basic Error | ±0.25‰ of full scale |
| Potential Stability | ±0.3 mV / 3 h |
| pH Range | 0–14 |
| pH Resolution | 0.01 |
| pH Basic Error | ±0.01 |
| Temperature Measurement Range | −5 to 105 °C |
| Temperature Resolution | 0.1 °C |
| Temperature Basic Error | ±0.2 °C |
| Operating Environment | 0–40 °C, 10–75% RH |
| Storage Environment | 0–40 °C, 10–90% RH |
| Standard Electrodes | 6501 Glass Composite pH Electrode, 5004 Redox Electrode, 2616 Silver Composite Electrode (Cl⁻), T-2 ATC Temperature Probe |
| Burettes Included | 10 mL and 20 mL |
| Stirring | Integrated Magnetic Stirrer |
| Titration Modes | Dynamic, Equivalence-Point, Manual, Predefined Endpoint |
| Method Storage | ≥100 user-defined titration methods |
| Custom Calculation Formula Support | Yes |
| Auto-purge, Flush & Drain Functions | Yes |
| Brand | Backyard Brains |
|---|---|
| Origin | USA |
| Model | DIY Muscle SpikerShield |
| Kit Type | Unassembled PCB with Components |
| Includes | 1× 3-lead EMG electrode cable (orange, red, red, black), 6× large-surface dry EMG electrodes, full component set for hand-soldering |
| Brand | Sutter |
|---|---|
| Origin | USA |
| Model | IPA |
| Type | Integrated Electrophysiology Amplifier System with Built-in ADC/DAC |
| Compliance | Designed for Whole-Cell, Cell-Attached, and Voltage/Current-Clamp Recordings |
| Software | SutterPatch v3.x (Real-Time Analysis, Multi-View Oscilloscope, Audit-Trail Data Archiving) |
| Brand | SYNTECH |
|---|---|
| Origin | Germany |
| Manufacturer Status | Authorized Distributor |
| Origin Category | Imported |
| Model | MP-15 |
| Pricing | Upon Request |
| Brand | Taiwolkang |
|---|---|
| Origin | Hubei, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | TWK-DPH4 |
| Instrument Type | Semi-Automatic |
| Micromanipulator Axes | X, Y, Z |
| Positioning Resolution | 0.01 mm |
| Stimulus Control | Dual-mode (Single-Pulse & Cyclic Pulse) with Compensated Airflow |
| Signal Acquisition | High-Impedance Input, 16-bit ADC, Dual-Channel Adaptive Amplification |
| Software | Real-Time EAG Waveform Visualization, ΔV Peak Annotation, Export to Excel/PNG/SVG |
| Noise Performance | Low Thermal Drift Baseline, Adjustable Bandpass Filtering, Adaptive 50/60 Hz Notch + Wavelet Threshold Denoising |
| Compliance | Compatible with GC Trigger/Synchronization Signals (TTL), Faraday Cage Integration Required |
| Brand | Warner Instruments |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Smart USSING |
| Instrument Type | Automated |
| Dimensions (W × D × H) | 380 mm × 75 mm × 20 mm |
| Temperature Control Range | 10 °C to 40 °C |
| Brand | WTW |
|---|---|
| Origin | Germany |
| Type | Ion-Selective Electrode (ISE) |
| Series | 500 (Half-Cell) and 800 (All-in-One Composite) |
| Connector Options | BNC or DIN |
| Measurement Range | Ion-specific, spanning from sub-ppb to saturated concentrations (e.g., F⁻: 0.02 mg/L to saturation |
| NH₄⁺ | 0.02–900 mg/L |
| NO₃⁻ | 0.4–62,000 mg/L) |
| Compliance | Designed for ASTM D1293, ISO 10523, USP <781>, and EPA Method 9056A applications |