Energy Dispersive Spectrometer
Filter
Showing all 22 results
| Brand | Angstrom |
|---|---|
| Origin | USA |
| Model | ELS5000 |
| Energy Resolution | 0.7 meV |
| Angular Resolution | 0.08° (momentum resolution ≈ 0.002 Å⁻¹ at 7.4 eV incident energy) |
| Optical Architecture | 4-grid tungsten electron optics, UHV-compatible, no polymer-coated or fiberglass-insulated wiring |
| Field of View | 103° |
| Electron Gun Diameter | 1.59 cm |
| Retractable Optics | Standard 2-inch to optional 4-inch retraction |
| Compatibility | AES-compatible, ARPES-integrated capable |
| Detection Modes | pA–nA current range with integrated lock-in amplifier and MCP detector |
| Brand | Bruker |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model Series | QUANTAX Transmission Electron Microscopy (TEM/STEM) EDS |
| Energy Resolution | <129 eV |
| Peak-to-Background Ratio | 20,000:1 |
| Maximum Count Rate | 1500 kcps |
| Elemental Detection Range | Be to Cf |
| Detector Active Area | 10–300 mm² |
| Window Options | Polymer Ultrathin Window or Windowless |
| Brand | Bruker |
|---|---|
| Origin | Germany |
| Model | QUANTAX FlatQUAD |
| Energy Resolution | <129 eV |
| Peak-to-Background Ratio | 20,000:1 |
| Maximum Count Rate | 4,000 kcps |
| Elemental Detection Range | Boron (B) to Californium (Cf) |
| Detector Active Area | 10–300 mm² |
| Window Type | Windowless |
| Brand | Bruker |
|---|---|
| Origin | Germany |
| Model | Quantax XFlash Series |
| Energy Resolution | <129 eV |
| Peak-to-Background Ratio | 20,000:1 |
| Maximum Count Rate | 1,500 kcps |
| Elemental Detection Range | Be to Cf |
| Detector Active Area | 10–300 mm² |
| Window Options | Ultrathin Polymer Window or Windowless Configuration |
| Brand | EDAX |
|---|---|
| Origin | USA |
| Model | Octane Elect |
| Energy Resolution | 127 eV |
| Maximum Count Rate | 400,000 cps |
| Detector Active Area | 30 mm² or 70 mm² |
| Window Material | Silicon Nitride (Si₃N₄) |
| Brand | EDAX |
|---|---|
| Origin | USA |
| Model | Octane Elite |
| Energy Resolution | 125 eV (Mn Kα) / 123 eV (optimized configuration) |
| Peak-to-Background Ratio | Not specified |
| Maximum Output Count Rate | 400,000 cps |
| Detector Active Area | 30 mm² (Octane Elite Plus) or 70 mm² (Octane Elite Super) |
| Window Material | Silicon Nitride (Si₃N₄) |
| Vacuum Compatibility | Fully sealed ultra-high vacuum detector housing |
| Integration | Compatible with SEM, FIB-SEM, and TEM platforms |
| Brand | EDAX |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | XLNCE SMX-BEN |
| Quotation | Upon Request |
| Energy Resolution | See Technical Datasheet |
| Peak-to-Background Ratio | See Technical Datasheet |
| Maximum Count Rate | See Technical Datasheet |
| Detector Active Area | See Technical Datasheet |
| Brand | JEOL |
|---|---|
| Origin | Japan |
| Model | SXES |
| Energy Resolution | 0.3 eV (at Al-L edge, 73 eV) |
| Detection Energy Range | 50–170 eV (JS50XL grating) / 70–210 eV (JS50XL grating) |
| Mounting Interface | EPMA WDS Port #2 (front right) or FE-SEM WDS port (front left-rear) |
| Dimensions (W×D×H) | 168 mm × 348 mm × 683 mm (including CCD distance from interface) |
| Weight | 25 kg |
| Compatible Instruments | EPMA — JXA-8530F, JXA-8230, JXA-8500F, JXA-8200 |
| Brand | LARGEBEAM |
|---|---|
| Origin | USA |
| Manufacturer Type | OEM Manufacturer |
| Import Status | Imported |
| Model | RIIDEye |
| Pricing | Upon Request |
| Detector Type | 2×2 NaI(Tl) scintillator & 1.5×1.5″ LaBr₃(Ce) crystal |
| Energy Range | 20 keV – 3 MeV |
| Display | 3.5″ TFT-LCD, 320×240 resolution, 32,000-color backlight |
| Battery Life | 8 hours (rechargeable Li-ion), with 6 spare AA battery slots |
| Weight | 2.6 kg (5.7 lb) with NaI configuration |
| Dimensions | 27.9 × 12.0 × 21.9 cm (11.0 × 4.7 × 8.6 in) |
| Operating Temperature | −20 °C to +50 °C (−4 °F to 122 °F) |
| Neutron Detection | 1.8 × 3.4 cm Ce-doped Cs₂LiYCl₆ (CLYC) crystal |
| Isotope Library | 47 nuclides |
| Trigger Modes | ANSI, ANSI+, Security, Medical, Industrial, User-Defined |
| Stabilization | Automatic K-40 background compensation, no external reference source required |
| Brand | Makeway |
|---|---|
| Model | MKW-3000 |
| Origin | Shanghai, China |
| Detector Type | Multi-probe EDS-compatible |
| Energy Resolution | 120 eV |
| Operating Environments | High Vacuum & Ambient Air |
| Maximum Beam Scan Area | 60 × 60 mm² |
| Sample Positioning | 4-axis Motorized Stage (Vacuum & Air) |
| Beam Control | Motorized Variable Aperture & Remote Focusing |
| Compliance | Designed for ISO/IEC 17025-aligned radiation effects testing workflows |
| Brand | Oxford Instruments |
|---|---|
| Origin | United Kingdom |
| Model | AZtecTEM |
| Instrument Type | EDS Software Platform |
| Compatibility | JEOL 200 kV & 300 kV Transmission Electron Microscopes equipped with JED EDS detectors |
| Key Features | Point-and-ID analysis, LineScan, Elemental Mapping (TruMap, QuantMap), Drift Correction (AutoLock), Real-time Dynamic Imaging (AZtecLive) |
| Brand | Oxford Instruments |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Ultim Extreme Infinity ∞ |
| Quotation | Upon Request |
| Detector Type | Sidewall-Insertion (Side-Entry) |
| Energy Resolution | C Ka ≤ 46 eV @ 50,000 cps |
| Elemental Range | Li (Z=3) to Cf (Z=98) |
| Window Type | Windowless |
| Brand | Oxford Instruments |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Ultim Extreme |
| Instrument Type | Multi-Detector Configuration |
| Energy Resolution | 127 eV (Mn Kα) |
| Peak-to-Background Ratio | 20,000:1 |
| Maximum Count Rate | 500,000 cps |
| Elemental Detection Range | Li to Bi |
| Detector Active Area | 100 mm² |
| Window Type | Windowless |
| Brand | Oxford Instruments |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Ultim Max Infinity ∞ |
| Quotation | Upon Request |
| Detector Mounting | Tilting (Side-Entry) |
| Energy Resolution | C Ka < 46 eV @ 50,000 cps |
| Elemental Detection Range | Be (Z=4) to Cf (Z=98) |
| Detector Active Area Options | 40 mm², 65 mm², 100 mm², 170 mm² |
| Window Type | SuperATW (Atmospheric Thin Window) |
| Brand | Oxford Instruments |
|---|---|
| Origin | United Kingdom |
| Model | Ultim Max |
| Detector Type | Tilting Insertion Mount |
| Energy Resolution | 127 eV (Mn Kα) |
| Peak-to-Background Ratio | 200,000:1 |
| Maximum Count Rate | 1,500,000 cps |
| Elemental Detection Range | Be to Cf |
| Active Detector Area | 40–170 mm² |
| Window Type | Super-Atmospheric Thin Window (SATW) |
| Brand | Oxford Instruments |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Ultim Max TLE |
| Instrument Type | Side-Insertion EDS Detector |
| Energy Resolution | 125 eV (Mn Kα) |
| Peak-to-Background Ratio | 200,000:1 |
| Maximum Count Rate | >200,000 cps (Xplore TEM), up to 400,000 cps (Ultim Max TLE, quantitative mode) |
| Elemental Detection Range | Beryllium (Be) to Californium (Cf) |
| Active Detector Area | 80 mm² (Xplore TEM), 100 mm² (Ultim Max TLE) |
| Window Type | Windowless |
| Brand | Oxford Instruments |
|---|---|
| Origin | United Kingdom |
| Model | UltimMax TEM |
| Instrument Type | Side-entry (tilt-compatible) |
| Energy Resolution | 125 eV (Mn Kα) |
| Peak-to-Background Ratio | 200,000:1 |
| Maximum Count Rate | 400,000 cps |
| Elemental Detection Range | Be to Cf |
| Detector Active Area | 80 mm² |
| Window Type | Windowless |
| Solid Angle | 0.2–0.6 srad |
| Low-Energy X-ray Sensitivity Gain | Up to 8× vs. conventional windowed detectors |
| In Situ Operation Temperature | Up to 1000 °C |
| Compatible Accelerating Voltages | Up to 200 kV |
| Brand | Oxford Instruments |
|---|---|
| Origin | United Kingdom |
| Model | UltimMax TLE |
| Detector Type | Tilting Insertion Geometry |
| Energy Resolution | 125 eV (Mn Kα) |
| Peak-to-Background Ratio | 200,000:1 |
| Maximum Input Count Rate | 400,000 cps |
| Elemental Detection Range | Be to Cf |
| Active Detector Area | 100 mm² |
| Window Type | Windowless |
| Solid Angle | 0.5–1.1 srad |
| Brand | Oxford Instruments |
|---|---|
| Origin | United Kingdom |
| Model | Unity |
| Mounting Type | Side-entry (inclined insertion) |
| Detector Architecture | Integrated Backscattered Electron (BSE) and Energy-Dispersive X-ray (EDS) Sensor Assembly |
| Positioning | Mounted directly beneath the objective lens pole piece |
| Brand | Oxford Instruments |
|---|---|
| Origin | United Kingdom |
| Model | Xplore 30 |
| Detector Type | Tilting (Side-Entry) |
| Energy Resolution | 129 eV at Mn Kα |
| Peak-to-Background Ratio | 20,000:1 |
| Maximum Count Rate | 1,000,000 cps |
| Elemental Detection Range | Be to Cf |
| Active Detector Area | 300 mm² |
| Window Type | Beryllium Window |
| Brand | Oxford Instruments |
|---|---|
| Origin | United Kingdom |
| Model | Xplore TEM |
| Instrument Type | Side-entry (tilt-compatible) EDS system for TEM |
| Energy Resolution | 125 eV (Mn Kα) |
| Peak-to-Background Ratio | 200,000:1 |
| Maximum Input Count Rate | 200,000 cps |
| Elemental Detection Range | Beryllium (Be) to Californium (Cf) |
| Detector Active Area | 80 mm² |
| Window Type | Windowless (ultra-thin polymer support) |
| Brand | Oxford Instruments |
|---|---|
| Origin | United Kingdom |
| Model | Xplore15 / Xplore30 |
| Detector Geometry | Tilting (Side-entry) |
| Energy Resolution | 129 eV @ 100,000 cps |
| Peak-to-Background Ratio | 20,000:1 |
| Maximum Count Rate | 1,000,000 cps |
| Elemental Detection Range | Boron (B) to Californium (Cf) |
| Active Crystal Area | 15 mm² or 30 mm² |
| Window Type | Super-Atmospheric Thin Window (SATW) |
