| Brand | JiDa Xiaotian'e |
|---|---|
| Origin | Jilin, China |
| Model | GDYK-90 |
| Instrument Type | Conventional Dual-Channel Gas Sampler |
| Flow Range | 0.1–1.5 L/min |
| Flow Stability | ≤5% |
| Flowmeter Accuracy | ±5% |
| Flow Repeatability | ≤2% |
| Timing Accuracy | ±0.2% |
| Temperature Display Accuracy | ±2 °C |
| Sampling Volume Range | 1–50 L |
| Sampling Delay Range | 0–999 min (1 s resolution) |
| Display | High-Density Dot-Matrix LCD with Adjustable Backlight |
| Battery | 9600 mAh Li-ion, ≥8 h continuous dual-channel operation |
| Auto-Power-Off Timeout | Configurable |
| Refresh Interval | 1 s |
| Standard Volume Calculation | Automatic post-sampling conversion |
| Brand | JiDa Xiaotian'e |
|---|---|
| Origin | Jilin, China |
| Manufacturer Type | Direct Manufacturer |
| Origin Category | Domestic (China) |
| Model | GDYS-101SE2 |
| Instrument Type | Portable |
| Measurement Principle | DPD-based Spectrophotometry |
| Measured Parameter | Chlorine Dioxide (ClO₂) |
| Measurement Range | 0.00–3.00 mg/L |
| Accuracy | ≤5% |
| Repeatability | ±0.01 mg/L |
| Resolution | 0.01 mg/L |
| Limit of Detection (LOD) | 0.02 mg/L |
| Light Source | 520 nm LED |
| Photometric Stability | ±0.005 Abs / 20 min |
| Measurement Time | 1 minute |
| Operating Temperature | 15–40 °C |
| Power Supply | DC 9 V (battery-powered) |
| Dimensions | 170 × 90 × 35 mm |
| Weight | 300 g |
| Brand | JiDa Xiaotian'e |
|---|---|
| Origin | Jilin, China |
| Model | GDYS-201MC |
| Instrument Type | Portable/HANDHELD Water Quality Analyzer |
| Detection Parameters | Free Chlorine, Total Chlorine, Ozone, Turbidity, Fluoride, Nitrite Nitrogen, Ammonia Nitrogen, Dissolved Oxygen |
| Light Source | High-Brightness LED |
| Optical Stability | 0.005 Abs/h |
| Sample Cell | Cylindrical Glass Cuvette & Standard Glass Cuvette |
| Power Supply | AC 220 V ± 22 V, 50 Hz ± 1 Hz |
| Rechargeable Battery | 7.4 V / 1800 mAh |
| Operating Temperature | 5 °C to 40 °C |
| Connectivity | USB, RS232, Bluetooth (for wireless printing) |
| Brand | JiDa Xiaotian'e |
|---|---|
| Origin | Jilin, China |
| Model | GDYS-900M |
| Instrument Type | Portable/HANDHELD Water & Air Quality Analyzer |
| Detection Parameters | Residual Chlorine, Total Chlorine, Ozone, Chlorine Dioxide, Ammonia Nitrogen, Sulfide (Water) |
| Light Source | High-Brightness LED |
| Wavelengths | 380, 430, 470, 520, 538, 595, 630 nm |
| Photometric Stability | ≤0.005 Abs/h |
| Operating Temperature | 5–40 °C |
| Detector | Integrated Photodiode Sensor |
| Sample Cell | Cylindrical Glass Cuvettes & Standard Glass Cuvettes |
| Power Supply | AC/DC Dual Mode |
| Data Storage | 32 GB internal flash memory |
| Connectivity | USB 2.0, RJ45 Ethernet, Built-in Wi-Fi (IEEE 802.11 b/g/n) |
| Display | Color TFT Touchscreen |
| OS | Windows Embedded Standard 7 |
| Onboard Software | Preloaded calibration curves, sample metadata entry (sample ID, analyte, operator, lab name), audit-ready data logging |
| Printing | Integrated thermal printer + external printer support via USB/Ethernet/Wi-Fi |
| Brand | JiDa-Xiaotian'e |
|---|---|
| Origin | Jilin, China |
| Manufacturer Type | Direct Manufacturer |
| Product Origin | Domestic (China) |
| Model | GDYK-160 |
| Instrument Type | Conventional Gas Sampler |
| Configuration | Single-Channel Gas Sampler |
| Flow Range | 0.5 L/min |
| Flow Stability | ≤5% |
| Flowmeter Accuracy | ≤±5% |
| Temperature & Pressure Measurement | Integrated High-Precision Sensors |
| Operating Temperature | -10–45 °C |
| Continuous Operation Time | ≥8 h |
| Flow Error | ≤±3% |
| Timing Accuracy | <0.1% |
| Pump Design | Custom Rubber Diaphragm with Dual-Ball-Bearing Motor |
| Acoustic Noise Reduction | Engineered Passive Damping System |
| Brand | JiDa-Xiaotian'e |
|---|---|
| Origin | Jilin, China |
| Manufacturer Type | Manufacturer |
| Region of Origin | Domestic (China) |
| Model | GDYK-202S |
| Detection Principle | Colorimetric Method (MBTH-based spectrophotometry) |
| Measurement Range | 0.00–1.00 mg/m³ (at 10 L sampling volume) |
| Sampling Method | Pump-aspiration |
| Light Source | High-brightness LED |
| Wavelength | 630 nm |
| Detection Limit | 0.01 mg/m³ (at 10 L sampling volume) |
| Accuracy | ±5% |
| Power Supply | 9 V rechargeable lithium battery |
| Compliance | GB/T 18204.2–2014 |
| Brand | JiDa-Xiaotian'e |
|---|---|
| Origin | Jilin, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | GDYS-101SF |
| Instrument Type | Portable/Handheld Water Quality Analyzer |
| Analyte | Fluoride |
| Detection Limit | 0.01 mg/L |
| Measurement Range | 0.00–1.00 mg/L |
| Accuracy | ±5% |
| Analysis Time | ≤30 minutes |
| Method Compliance | GB/T 5750.5–2006 |
| Brand | JiDa-Xiaotian'e |
|---|---|
| Origin | Jilin, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | GDYS-101SG |
| Instrument Type | Portable/Handheld Water Quality Analyzer |
| Target Analyte | Hexavalent Chromium (Cr(VI)) |
| Detection Limit | 0.01 mg/L |
| Measurement Range | 0.00–1.00 mg/L |
| Accuracy | ±5% |
| Method Compliance | GB/T 5750.6–2006 |
| Analysis Time | ≤3 minutes per sample |
| Reagent Format | Single-use, pre-packaged test kit |
| Brand | JiDa-Xiaotian'e |
|---|---|
| Origin | Jilin, China |
| Manufacturer Type | Direct Manufacturer |
| Product Origin | Domestic (China) |
| Model | GDYS-101SL |
| Measurement Parameter | Total Phosphorus |
| Instrument Type | Portable |
| Measurement Principle | Colorimetric Method (Standardized Molybdenum Blue Reaction per GB 11906–1989) |
| Measurement Range | 0.00–1.00 mg/L |
| Accuracy | ±5% of reading |
| Detection Limit | 0.02 mg/L |
| Brand | JiDa-Xiaotian'e |
|---|---|
| Origin | Jilin, China |
| Model | GDYS-MW400 |
| Instrument Type | Portable / Handheld Water Quality Analyzer |
| Detection Parameters | Total Phosphorus, Ammonia Nitrogen, Total Nitrogen, Chemical Oxygen Demand (COD) (High-Range & Low-Range) |
| Wavelengths | 380 / 430 / 470 / 520 / 538 / 595 / 630 nm |
| Photometric Stability | ±0.005 Abs/h |
| Detector | Integrated Photodiode Sensor |
| Light Source | High-Brightness LED (100,000 h lifetime) |
| Sample Cells | 19 mm cylindrical glass cuvettes & 50 mm rectangular glass cuvettes |
| Power Supply | AC 220 V ±10 %, 50 Hz ±1 Hz / Rechargeable Li-ion battery (8.4 V, 1800 mAh) |
| Operating Temperature | 5–40 °C |
| Dimensions | 310 × 225 × 125 mm |
| Weight | 1.7 kg |
| Data Interfaces | USB 2.0, RS-232 |
| Connectivity | Bluetooth (for printer pairing), PC software for Excel export and report generation |
| Brand | JiDa-Xiaotianshe |
|---|---|
| Origin | Jilin, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | GDYK-200M |
| Measurement Principle | Colorimetric Method (Phenol Reagent & AHMT Methods) |
| Measurement Range | 0.00–1.00 mg/m³ |
| Sampling Method | Pump-Aspiration |
| Compliance | GB 50325-2020 (Standard for Indoor Environmental Pollution Control in Civil Building Engineering) |
| Calibration Capability | User-Defined Calibration Curve Generation |
| Interface | Local Display + PC Connectivity |
| Brand | JiDa-Xiaotianshe |
|---|---|
| Origin | Jilin, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Country of Origin | China |
| Model | GDYS-101SN |
| Instrument Type | Portable |
| Measurement Principle | DPD Colorimetric Spectrophotometry |
| Measured Parameters | Residual Chlorine, Total Chlorine |
| Range | Residual Chlorine: 0.00–9.99 mg/L |
| Total Chlorine | 0.00–9.99 mg/L |
| Accuracy | ±5% of reading |
| Detection Limit | Residual Chlorine: 0.10 mg/L |
| Total Chlorine | 0.05 mg/L |
| Compliance Standard | GB/T 5750.11–2006 |
| Analysis Time | ≤3 minutes per sample |
| Reagent Format | Single-use, pre-packaged DPD reagent kits |
| Brand | JiDa-Xiaotianshe |
|---|---|
| Origin | Jilin, China |
| Manufacturer Type | Direct Manufacturer |
| Origin Category | Domestic (China) |
| Model | GDYS-201M |
| Price Range | USD 280 – 1,400 |
| Instrument Type | Portable / Handheld Water Quality Analyzer |
| Measurable Parameters | Free Chlorine, Total Chlorine, Available Chlorine, Chlorine Dioxide, Chlorite, Ozone, Formaldehyde, Hydrogen Peroxide, Peracetic Acid |
| Light Source | High-Brightness LED (380/430/470/520/538/595/630 nm selectable per configuration) |
| Optical Stability | ≤0.005 Abs/h |
| Detector | Integrated Photodiode Sensor |
| Sample Cell | Cylindrical Glass Cuvette & Standard Glass Cuvette (10 mm pathlength) |
| Display | 4.7-inch TFT LCD with Chinese UI |
| Power Supply | Rechargeable Li-ion Battery + AC Adapter |
| Interfaces | USB 2.0, RS-232 (COM) |
| Brand | JiDa-Xiaotianshen |
|---|---|
| Origin | Jilin, China |
| Manufacturer Type | OEM Manufacturer |
| Region of Manufacture | Domestic (China) |
| Model | GDYS-301M |
| Price Range | USD 1,400–4,200 |
| Instrument Type | Benchtop Water Quality Analyzer |
| Test Parameters | Free Chlorine, Total Chlorine, Chlorine Dioxide, Nitrate Nitrogen, Ozone, Ammonia Nitrogen, and 35 Total Parameters |
| Brand | Jilin University & Little Swan |
|---|---|
| Model | GDYS-104SI |
| Origin | Shanghai, China |
| Instrument Type | Benchtop Photometric Analyzer for Bromate (BrO₃⁻) |
| Measurement Principle | LED-based Absorption Spectrophotometry at 528 nm |
| Detection Limit | 0.004 mg/L |
| Range | 0.000–0.040 mg/L |
| Accuracy | ±0.002 mg/L |
| Repeatability | ±0.002 mg/L |
| Response Time | <20 min per sample |
| Operating Temperature | 5–40 °C |
| Power Supply | AC 220 V ±22 V, 50 Hz ±1 Hz |
| Dimensions | 470 × 280 × 180 mm |
| Weight | 3.8 kg |
| Sample Throughput | Up to 8 samples per batch with integrated pre-concentration and filtration |
| Optical Path | Extended-path cuvette design for enhanced sensitivity |
| Data Interfaces | USB 2.0 and RS-232 |
| Compliance | Designed for routine QC in bottled water production per GB 8537–2018 and aligned with ISO 10523:2022 (water quality — determination of pH) and AOAC Official Method 2015.01 (bromate in drinking water) |
| Brand | Jilin University & Little Swan |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | GDYS-302S |
| Weight | 1.7 kg |
| Operating Temperature | 5–40 °C |
| Power Supply | AC 220 V ± 22 V, 50 Hz ± 1 Hz |
| Repeatability | ±5% |
| Accuracy (Measurement Error) | ±5% |
| Light Source | High-brightness LED |
| Wavelengths | 430 nm, 538 nm |
| Absorbance Range | 0.000–2.000 Abs |
| Absorbance Stability | ≤0.005 Abs/h |
| Detector | Integrated Photodiode Sensor |
| Sample Cell | Cylindrical Glass Cuvette, 16 mm Inner Diameter |
| Display | 4.7-inch TFT LCD with Chinese UI |
| Data Interface | USB + RS-232 (COM) |
| Battery | Rechargeable Li-ion, 7.4 V / 900 mAh |
| Power Consumption | 5 W |
| Brand | Jilin University & Little Swan |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | GDYS-601SB |
| Quotation | Upon Request |
| Operating Temperature | 0 °C to 40 °C |
| Power Supply | 9 V DC (rechargeable Li-ion battery included) |
| Response Time | 1 s |
| Photometric Stability | ±0.005 Abs/h |
| Optical Wavelengths | 520 nm and 538 nm |
| Absorbance Range | 0.000–2.000 Abs |
| Light Source | High-brightness LED (rated lifetime >100,000 h) |
| Measurement Chamber | Integrated cylindrical sealed cuvette |
| Calibration | Factory-preloaded calibration curves for all target analytes |
| Brand | Jilin University & Little Swan |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Regional Classification | Domestic (China) |
| Model | GDYS-800M |
| Instrument Type | Portable / Handheld Water Quality Analyzer |
| Detection Principle | Spectrophotometry |
| Measurable Parameters | Free Chlorine, Chlorine Dioxide, COD (Permanganate Index), Total Hardness (as CaCO₃), Color, Turbidity, and 32 additional routine water quality indicators |
| Measurement Ranges | Free Chlorine: 0–5 mg/L |
| Total Hardness (as CaCO₃) | 0–500 mg/L |
| Photometric Stability | ≤0.005 Abs/h |
| Wavelength Options | 380, 430, 470, 520, 538, 595, 630 nm (configurable per parameter set) |
| Light Source | High-brightness LED |
| Detector | Integrated Photodiode Sensor |
| Sample Cell | Cylindrical Glass Cuvettes and Standard Glass Cuvette (10 mm pathlength) |
| Operating Environment | 5–40 °C |
| Display | 12-inch Multi-touch LCD |
| Connectivity | Ethernet, USB 2.0, Wi-Fi 802.11 b/g/n |
| Power Supply | AC Adapter (100–240 V) + Rechargeable Li-ion Battery (≥8 h continuous operation) |
| Data Output | Built-in Thermal Printer, CSV Export, Cloud Sync via Secure HTTPS API |
| Brand | Jilin University & Little Swan |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | GDYS-501SC |
| Power Supply | 9 V DC (alkaline or rechargeable battery) |
| Operating Temperature | 0 °C to 40 °C |
| Optical Wavelengths | 520 nm and 538 nm |
| Photometric Range | 0.000–2.000 Abs |
| Photometric Stability | ±0.005 Abs/h |
| Measurement Principle | Fixed-wavelength colorimetry with integrated optical path |
| Sample Vessel | Cylindrical sealed cuvette (direct measurement post-reaction) |
| Preloaded Calibration Curves | Yes, factory-calibrated for target analytes |
| Reagent Format | Dry-powder or liquid-stabilized prepackaged reagents |
| Compliance | Designed to support ASTM D1292 (pH), ASTM D3867 (nitrite-N), ASTM D1688 (ammonia-N), ISO 5815-1 (dissolved oxygen), and GB/T 5750.5–2023 (Chinese national standards for drinking water quality) |
| Brand | Jilin University Xiaotian'e |
|---|---|
| Origin | Jilin, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Category | Domestic (China) |
| Model | MAI-50G |
| Price Range | USD 1,400–7,000 |
| Instrument Type | Benchtop Laboratory Analyzer |
| Measurement Principle | Infrared Spectrophotometry (Dual-Wavelength Absorption at C–H Stretching Bands) |
| Measurement Range | 0.0–80.0 mg/L |
| Detection Limit | 0.2 mg/L |
| Accuracy | ≤1.5% RSD (at 10 mg/L) |
| Wavenumber Range | 3400–2400 cm⁻¹ |
| Absorbance Range | 0.0000–2.0000 Abs |
| Wavenumber Accuracy | ±2 cm⁻¹ |
| Wavenumber Repeatability | ±2 cm⁻¹ |
| Baseline Drift | ≤±0.005 Abs / 30 min |
| Operating Temperature | 5–35 °C |
| Linearity Correlation Coefficient | R > 0.999 |
| Power Supply | AC 220 V ±10%, 50–60 Hz |
| Brand | Jilin University Xiaotianshe |
|---|---|
| Origin | Jilin, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | Water Quality Rapid Test Kit |
| Price Range | USD 140 – 7,200 (based on configuration) |
| Instrument Type | Portable |
| Brand | Jilin University-Xiaotian'e |
|---|---|
| Origin | Jilin, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | GDYK-W100S |
| Price Range | USD 700–1,400 (FOB) |
| Measurement Principle | Colorimetric Method |
| Measurement Range | 0.00–2.00 ppm |
| Resolution | 0.1 ppm |
| Repeatability | ≤ ±5% |
| Sampling Method | Pump-Aspiration |
| Response Time | 5–15 minutes |
| Operating Temperature | 0–25 °C |
| Relative Humidity Range | 15–90% RH |
| Brand | Jilin University-Xiaotianshe |
|---|---|
| Origin | Jilin, China |
| Manufacturer Type | Direct Manufacturer |
| Region of Manufacture | Domestic (China) |
| Model | GDYK-501RC |
| Instrument Type | Portable |
| Operating Principle | Spectrophotometry |
| Detection Parameters | Formaldehyde (HCHO), Benzene Homologues, Total Volatile Organic Compounds (TVOC), Ammonia (NH₃) |
| Detection Limits (mg/m³) | 0.01 (HCHO), 0.05 (Benzene Homologues), 0.05 (TVOC), 0.10 (NH₃) |
| Measurement Ranges (mg/m³) | 0.00–2.00 (HCHO), 0.00–1.00 (Benzene Homologues), 0.00–4.00 (TVOC), 0.00–5.00 (NH₃) |
| Light Sources | 630 nm (HCHO), 465 nm (Benzene/TVOC), 430 nm (NH₃) |
| Analytical Methods | National Standard Phenol Reagent Method (HCHO), Colorimetric Methods (Benzene/TVOC), National Standard Nessler’s Reagent Method (NH₃) |
| Accuracy | ±5% FS |
| Display | 5-inch TFT color touchscreen + 2.9-inch e-ink auxiliary display |
| Connectivity | USB, RS232, RS485 (optional), Bluetooth (for wireless printing) |
| Power Supply | Rechargeable Li-ion battery + AC/DC adapter |
| Data Storage | Internal non-volatile memory with conditional search capability |
| Brand | Jilin University–Xiaotian’e |
|---|---|
| Origin | Jilin, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Category | Domestic (China) |
| Model | MAI-100G Infrared Oil Content Analyzer |
| Instrument Type | Laboratory Benchtop Analyzer |
| Measurement Principle | Infrared Spectrophotometry (C–H Stretch Absorption at 2930 cm⁻¹, 2960 cm⁻¹, and 2850 cm⁻¹) |
| Measurement Range | 0.40–100 mg/L (using 4-cm pathlength cell, standard n-hexane extract, 1:1 extraction ratio) |
| Detection Limit | < 0.1 mg/L (per JJG 950–2012 verification protocol) |
| Accuracy | ±5% RSD (at 40 mg/L standard solution) |
| Compliance | HJ 637–2018, JJG 950–2012 Class A requirements, ASTM D7066–22 (equivalent IR methodology), ISO 9377-2:2000 (Water quality — Determination of hydrocarbon oil index — Part 2: Infrared spectrometric method) |
| Brand | Jing |
|---|---|
| Origin | Switzerland |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Mini CAST |
| Pricing | Upon Request |
| Aerosol Generation Principle | Diffusion Flame / Premixed Flame Combustion |
| Particle Size Range | 10–200 nm |
| Particle Number Concentration | Up to 1×10⁸ particles/cm³ |
| Fuel Efficiency | Optimized for Low Consumption |
| Control Interface | PC-based Automated Software |
| Brand | Jingcheng Huatai |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | HT-SS-I |
| Instrument Type | Portable |
| Measurement Principle | ISO 7027-compliant dual-beam infrared light scattering and absorption |
| Range | 0.1–50,000 mg/L (customizable high-range options available) |
| Accuracy | ±5% of reading (dependent on sample homogeneity) |
| Resolution | 0.01–1 mg/L (scale-dependent) |
| Sensor Material | SUS316L stainless steel |
| Host Housing | ABS+PC polymer blend |
| Sensor IP Rating | IP68 |
| Host IP Rating | IP67 |
| Operating Temperature | 0–50 °C (non-freezing) |
| Storage Temperature | −15 to 60 °C |
| Sensor Dimensions | Ø60 mm × 254 mm, 1.65 kg |
| Host Dimensions | 203 × 100 × 43 mm, 0.5 kg |
| Standard Cable Length | 3 m (extendable) |
| Display | 3.5-inch color LCD with adjustable backlight |
| Data Storage Capacity | >100,000 records |
| Power | Rechargeable Li-ion battery, USB-C charging (no battery removal required) |
| Interface | USB data export |
| Calibration Options | Standard solution calibration and field water sample calibration |
| Auto-sensor recognition | Yes |
| Sensor configuration & calibration via host | Yes |
| Brand | Jingcheng Huatai |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | HT-WY |
| Pricing | Upon Request |
| Detection Limit | ≤0.01 ng/mL (3σ definition) |
| Uranium Measurement Range | 0–20 ng/mL (extendable to 100 ng/mL via dilution) |
| Linearity Coefficient | ≥0.9995 |
| Precision (RSD) | ≤5% |
| Stability (8-h RSD at 2 ng/mL) | ≤7% after 1-h warm-up |
| Data Storage Capacity | 4,000 data points |
| Interface | USB 2.0, 100Base-T4 Ethernet |
| Printer | Integrated thermal printer (57 mm × 40 mm paper) |
| Power Supply | 220 V ±10%, 50 Hz |
| Net Weight | 15 kg |
| Brand | Jingcheng Huatai |
|---|---|
| Origin | Beijing, China |
| Model | HTY-203 |
| Sampling Depth | 10 m |
| Core Diameter | 5 cm |
| Core Length | 30 cm |
| Configuration | T-handle, 9 × 100 cm extension rods, 2 × 50 cm extension rods, depth-controlled peat coring bit, scraper, 2 wrenches, brush, 3 m steel tape measure, gloves, aluminum carrying case |
| Brand | Jingcheng Huatai |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | HTY-203 |
| Sampling Depth | 10 m |
| Core Diameter | 5 cm |
| Core Length | 30 cm |
| Configuration | T-handle, 9 × 100 cm extension rods, 2 × 50 cm extension rods, fixed-depth peat coring bit, scraper, 2 wrenches, brush, 3 m steel tape measure, gloves, aluminum carrying case |
| Brand | Jingcheng Huatai |
|---|---|
| Origin | Beijing, China |
| Model | HTYF-DT1-A |
| Operating System | Android 8.1 |
| Display | 7-inch capacitive touchscreen |
| Detection Channels | 6 |
| Wavelength Range | 420–680 nm (±2 nm per band) |
| Optical Path | 1 cm cuvette |
| Repeatability Error | ≤0.02% (K₂Cr₂O₇ solution) |
| Stability | Drift ≤0.3% in 60 min (transmittance), ≤0.001 absorbance unit in 60 min |
| Linearity Error | ≤0.1% (CuSO₄) |
| Sensor Output | Simultaneous in-situ measurement of 33 parameters including pH, EC, moisture, temperature, CEC, and elemental concentrations (N, P, K, Ca, Mg, S, Fe, Mn, B, Zn, Cu, Cl, Si, Mo, Se, Pb, As, Cd, Cr, Hg, Ni, Al, Ti, F) |
| Power Supply | AC 220 V ±10% / DC 12 V (internal Li-ion battery) |
| Power Consumption | ≤10 W |
| Data Storage | 4 GB internal memory |
| Connectivity | USB, Ethernet, 4G LTE, Wi-Fi |
| Compliance | Designed to support ISO 11260, ISO 14253-1, ASTM D5088, and GLP-aligned data integrity workflows |