Environmental Test Chamber
Filter
Showing 1951–1980 of 2009 results
| Brand | OK |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Price | USD 5,300 (FOB) |
| Chamber Capacity | 100–1000 L |
| Light Source | Long-Arc Air-Cooled Xenon Lamp |
| Spectral Range | 300–1200 nm |
| Irradiance Control | 300–800 nm @ 550 W/m² ±10% |
| Black Panel Temperature | 40–85 °C |
| Cabinet Temperature | 0–150 °C |
| Humidity Range (Light Cycle) | 20–75 %RH |
| Humidity Range (Dark Cycle) | 20–98 %RH |
| Temp. Uniformity | ±2.0 °C |
| Humidity Uniformity | ±3.0 %RH |
| Temp. Control Accuracy | ±0.5 °C |
| Humidity Control Accuracy | ±2.0 %RH |
| Spray Duration | 1–999 min (intermittent/continuous) |
| Spray Pressure | 70–127 kPa |
| Sample Mounting | Dual-layer flat mesh rack or 500-mm-diameter rotating turntable (0–3 rpm) |
| Internal Construction | SUS304 stainless steel |
| External Construction | SUS304 stainless steel or powder-coated steel |
| Power Supply | AC 380 V ±5%, 50 Hz ±0.5 Hz |
| Lamp Life | ≈1,500 h at nominal irradiance |
| Brand | OK Instruments |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Price | USD 5,200–12,800 (FOB Shanghai, model-dependent) |
| Temperature Range | RT+10°C to 70°C |
| Humidity Range | 50–98% RH |
| Black Panel Temperature | 55–90°C ±3°C |
| Irradiance Range | 0–550 W/m² (290–800 nm) |
| Lamp Configuration | 3 × 1.8 kW air-cooled xenon lamps (rated life: 1600–1800 h) |
| Sample Rotation | 360° continuous |
| Rain Cycle Control | 1–9999 min duration |
| Viewing Window | Multi-layer tempered glass |
| Internal Dimensions (W×D×H, mm) | 450×450×500 (OK-XD-100) to 800×1000×1000 (OK-XD-800) |
| Power Supply | 3-phase 5-wire AC 380 V ±10%, 50 Hz |
| Cooling Water Pressure | 0.08–0.2 MPa |
| Ambient Operating Conditions | 5–35°C, ≤85% RH |
| Key | Brand: OEM / Import Origin |
|---|---|
| Chamber Volume Options | 100 L / 225 L / 500 L / 1000 L |
| Temperature Range | 0–150°C (Chamber), 40–85°C (Black Panel) |
| Humidity Range | 20–75% RH (Light Cycle), 20–98% RH (Dark Cycle) |
| Irradiance | 550 W/m² ±10% (300–800 nm) or 1000 W/m² ±10% (300–1200 nm) |
| Xenon Lamp Power | 1.8 kW / 2.5 kW / 6 kW |
| Lamp Life | ~1500 h |
| Spray Duration | 1–999 min (Intermittent or Continuous) |
| Spray Pressure | 70–127 kPa |
| Sample Mounting | Dual-layer mesh tray or 500 mm diameter rotating carousel (0–3 rpm) |
| Construction | Interior – SUS304 stainless steel |
| Control Accuracy | ±0.5°C (Temp), ±2.0% RH (Humidity) |
| Uniformity | ±2.0°C (Temp), ±3.0% RH (Humidity) |
| Compliance | GB/T 8427, GB/T 16422-2, ISO 4892-2, ASTM D529, GB/T 14576, GB/T 15102-2006, GB/T 15104-2006 |
| Brand | OK Instruments |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Price Range | USD 5,200–14,800 (FOB) |
| Chamber Volume Options | 100 L / 225 L / 500 L / 1000 L |
| Temperature Range | 0–150 °C (Chamber), 40–85 °C (Black Panel) |
| Humidity Range | 20–98% RH (Cyclic Control) |
| Irradiance | 550 W/m² ±10% (300–800 nm) or 1000 W/m² ±10% (300–1200 nm) |
| Xenon Lamp Power | 1.8 kW / 2.5 kW / 6 kW |
| Lamp Life | ≥1500 h |
| Spray Cycle | 1–999 min (Intermittent/Continuous) |
| Spray Pressure | 70–127 kPa |
| Sample Mounting | Dual-layer wire mesh tray or 500 mm diameter rotating drum (0–3 rpm) |
| Construction | Interior – SUS304 stainless steel |
| Power Supply | AC 380 V ±5%, 50 Hz ±0.5 Hz |
| Brand | Other Brands |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Price Range | USD 5,300–15,800 (FOB) |
| Chamber Models | OK-XD-100 / OK-XD-225 / OK-XD-500 / OK-XD-1000 |
| Internal Dimensions (W×D×H, cm) | 50×50×40 |
| Temperature Range | 0–150°C (chamber), 40–85°C (black panel) |
| Humidity Range | 20–75% RH (light cycle), 20–98% RH (dark cycle) |
| Control Accuracy | ±0.5°C (temp), ±2.0% RH (humidity) |
| Uniformity | ±2.0°C (temp), ±3.0% RH (humidity) |
| Spectral Irradiance | 300–800 nm @ 550 W/m² ±10% |
| Xenon Lamp Power | 1.8 kW / 2.5 kW / 6 kW |
| Lamp Life | ≥1500 h |
| Spray Cycle | 1–999 min (intermittent or continuous) |
| Spray Pressure | 70–127 kPa |
| Sample Mounting | Dual-layer flat mesh rack or 500-mm-diameter rotating turntable (0–3 rpm) |
| Construction | Interior – SUS304 stainless steel |
| Power Supply | AC 380 V ±5%, 50 Hz ±0.5 Hz |
| Brand | OK Instruments |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Price | USD 5,300–15,800 (FOB, varies by model and configuration) |
| Internal Dimensions (W×D×H, cm) | 50×50×40 |
| Temperature Range | 0–150°C (chamber), 40–85°C (black panel) |
| Humidity Range | 20–75% RH (light cycle), 20–98% RH (dark cycle) |
| Control Accuracy | ±0.5°C / ±2.0% RH |
| Uniformity | ±2.0°C / ±3.0% RH |
| Irradiance | 550 W/m² ±10% (300–800 nm) or 1000 W/m² ±10% (300–1200 nm) |
| Xenon Lamp Power | 1.8 kW / 2.5 kW / 6 kW |
| Lamp Life | ≈1,500 h |
| Spray Duration | 1–999 min (intermittent or continuous) |
| Spray Pressure | 70–127 kPa |
| Sample Mounting | Dual-layer flat mesh rack or 500 mm diameter rotating turntable (0–3 rpm) |
| Construction | Interior – SUS304 stainless steel |
| Power Supply | AC 380 V ±5%, 50 Hz ±0.5 Hz |
| Key | Temperature Uniformity: ±2°C |
|---|---|
| Temperature Fluctuation | ±0.5°C |
| Operating Temperature Range | RT+10°C to 70°C |
| Humidity Range | 90–98% RH |
| Internal Chamber Dimensions (W×H×D) | 450 × 1170 × 500 mm |
| Effective Irradiation Area | 900 × 210 mm |
| Black Panel Temperature Range | 40–65°C |
| UV Spectrum | UV-A (315–400 nm), UV-B (280–315 nm) |
| Sample-to-Lamp Distance | 50 mm |
| Lamp Center Spacing | 70 mm |
| Standard Specimen Size | 75 × 150 mm or 75 × 300 mm |
| Exposure Time Range | 0–999 h |
| Condensation Cycle Control | Adjustable |
| Control Method | PID Auto-Tuning |
| Water Tray Depth | 25 mm (Auto-Maintained) |
| Power Supply | AC 380 V ±10%, 50 ±0.5 Hz, 3-phase 5-wire |
| Ambient Operating Conditions | 5–30°C, ≤85% RH |
| Construction | Exterior – Powder-Coated Carbon Steel or SUS304 Brushed Stainless Steel |
| Safety Protections | Overtemperature, Leakage Current, Short Circuit, Motor Overheat, Overcurrent, Low-Water Level Detection |
| Brand | OEM / Custom-Built |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Price | USD 5,300 (Reference Only |
| Brand | Other Brands |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Price | USD 5,200 (Reference Only) |
| Light Source | Air-Cooled Long-Arc Xenon Lamp |
| Spectral Range | 290–800 nm (Full Solar Spectrum) |
| Irradiance Control | 0.35–0.65 W/m² @ 340 nm |
| Temperature Range | RT +10°C to 80°C |
| Humidity Range | 10–95% RH |
| Water Spray Cycle | Programmable On/Off |
| Sample Rotation | Dual-axis (Orbital + Self-rotation) |
| Filter Options | Daylight-Q, Window-Glass, Extended UV |
| Lamp Life | ~1600 h at 0.55 W/m² @ 340 nm |
| Compliance | ASTM G155, ISO 4892-2, SAE J2527, AATCC TM16, GB/T 16422.2 |
| Key | Internal Dimensions (D×W×H): 400×1250×700 mm |
|---|---|
| External Dimensions (D×W×H) | 450×1350×1700 mm |
| Temperature Range | RT+10°C to 70°C |
| Humidity Range | 65–95% RH |
| Sample-to-Lamp Distance | 240 mm |
| Spectral Range | 295–330 nm |
| Irradiance | 1000 µW/cm² @ 340 nm |
| Lamp Configuration | 8 × 40 W, 1200 mm linear xenon arc lamps |
| Condensation Method | Gravity-fed water condensation |
| Inner Chamber Material | SUS304 stainless steel |
| Control System | Digital temperature & timer controller |
| Water Consumption | ~8 L/day (deionized or distilled water recommended) |
| Brand | OEM / Other Brands |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Price | USD 5,200 (Reference Only) |
| Key | Lamp Power: 6 kW |
|---|---|
| Spectral Range | 290–800 nm |
| Irradiance Control | 550–1200 W/m² |
| Sample Rotation Speed | ≥1 rpm (infinitely variable) |
| Rainfall Duration | 1–9999 min (adjustable) |
| Rainfall Cycle Interval | 1–240 min (adjustable) |
| Irradiated Area | ~7500 cm² |
| Lamp-to-Sample Distance | 350–380 mm |
| Heating Power | ~3.6 kW |
| Humidification Power | ~3 kW |
| Cooling System | Single-stage hermetic compressor (Tecumseh/Tecumseh France equivalent) with R404A refrigerant |
| Evaporator Layout | Air-forced convection within ducted chamber wall |
| Humidity Control | PID-regulated steam humidification |
| Compliance | Designed to support ASTM G155, ISO 4892-2, SAE J2527, and AATCC TM16 test protocols |
| Brand | OEM / Custom-Built |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Price | USD 5,200 (FOB Shanghai, ex-factory reference only) |
| Internal Chamber Dimensions | 650 × 1100 × 600 mm (D×W×H) |
| Overall Dimensions | 1050 × 1550 × 1350 mm (D×W×H) |
| Temperature Range | RT+10°C to 70°C |
| Humidity Capacity | ≥95% RH |
| Lamp-to-Specimen Distance | 50 mm |
| Lamp Spacing | 35 mm |
| Irradiance Output | UVA-340 @ 0.68 W/m² (340 nm peak), UVB-313 @ 0.60 W/m² (313 nm peak) |
| UVA Spectral Band | 320–400 nm |
| UVB Spectral Band | 280–320 nm |
| Temperature Uniformity | ≤ ±2°C |
| Temperature Stability | ≤ ±0.5°C |
| Standard Specimen Size | 75 × 150 mm |
| Timer Range | 0–99 h |
| Temperature Sensor | PT-100 Platinum Resistance Thermometer |
| Control System | PID + TSSR Synchronized Digital Regulation |
| Electrical Components | Delixi (China) industrial-grade contactors & relays |
| Lamp Current Monitoring | Real-time analog display |
| Exterior & Interior Material | SUS304 stainless steel, precision TIG-welded construction |
| Sample Holder | Adjustable-height SUS304 rack with leveling feet and casters |
| Brand | Other Brands |
|---|---|
| Origin | Imported |
| Manufacturer Type | General Distributor |
| Rainfall Intensity | 600–3600 mm/h |
| Spray Arm Radius | 375 mm |
| Spray Arm Diameter | φ15 mm |
| Spray Arm Oscillation Angle | ±45° to ±90° |
| Nozzle Diameter | φ0.4 mm or φ0.8 mm |
| Nozzle Spacing | 50 mm |
| Turntable Speed | 1–10 rpm |
| Timer Range | 1 s – 99 h 99 min 99 s |
| Rain Cycle Setting | 1 s – 99 h |
| Internal Chamber Dimensions | 800 × 800 × 800 mm |
| Construction | ST12 Cold-Rolled Steel Outer Shell + Phosphated & Powder-Coated Finish |
| Interior | Seamless Welded SUS304 Stainless Steel |
| Spray Pipes | SUS304 Stainless Steel |
| Turntable Material | Stainless Steel Plate |
| Water Filtration | Ultra-Fine Stainless Steel Mesh Filter |
| Water Lift System | Pump-Based |
| Water Level Control | Float Switch |
| Radiation Measurement | Fiber-Optic Coupled Radiometer |
| Lamp Cooling | Closed-Loop Chilled Water Circulation System |
| Temperature Monitoring | Wireless Black Panel Thermometer (BPT) / Black Standard Thermometer (BST) |
| Safety Interlock | Coolant Flow–Dependent Xenon Lamp Ignition & Auto-Shutdown on Failure |
| Compliance | GB/T 2423.23–1990, GB/T 2423.38–1990, GB/T 4208–1993, GB/T 10485–1993, GB/T 4857.9–1992, GB/T 2014.9 |
| Brand | Other Brands |
|---|---|
| Origin | Imported |
| Manufacturer Type | General Distributor |
| Price | USD 5,300 (approx. based on ¥38,000) |
| Chamber Models | OK-XD-100 / OK-XD-225 / OK-XD-500 / OK-XD-1000 |
| Internal Dimensions (W×D×H, cm) | 50×50×40 / 50×75×60 / 80×80×80 / 100×100×100 |
| Temperature Range | 0–150°C (chamber), 40–85°C (black panel) |
| Humidity Range | 20–75% RH (light cycle), 20–98% RH (dark cycle) |
| Control Accuracy | ±0.5°C / ±2.0% RH |
| Uniformity | ±2.0°C / ±3.0% RH |
| Irradiance | 550 W/m² ±10% (300–800 nm) or 1000 W/m² ±10% (300–1200 nm) |
| Xenon Lamp Power | 1.8 kW / 2.5 kW / 6 kW |
| Lamp Life | ~1500 h |
| Spray Cycle | 1–999 min (intermittent/continuous) |
| Spray Pressure | 70–127 kPa |
| Sample Mounting | Dual-layer flat mesh rack or 500 mm diameter rotating turntable (0–3 rpm) |
| Construction | Interior – SUS304 stainless steel |
| Power Supply | AC 380 V ±5%, 50 Hz ±0.5 Hz |
| Brand | Other Brands |
|---|---|
| Origin | Imported |
| Manufacturer Type | General Distributor |
| Price | USD 5,300 (Reference Only) |
| Chamber Models | OK-XD-100 / OK-XD-225 / OK-XD-500 / OK-XD-1000 |
| Internal Dimensions (W×D×H, cm) | 50×50×40 / 50×75×60 / 80×80×80 / 100×100×100 |
| Overall Dimensions (W×D×H, cm) | 100×170×90 / 110×190×100 / 140×190×130 / 165×210×150 |
| Temperature Range | 0–150 °C (Chamber), 40–85 °C (Black Panel) |
| Humidity Range | 20–75% RH (Light Cycle), 20–98% RH (Dark Cycle) |
| Control Accuracy | ±0.5 °C (Temp), ±2.0% RH (Humidity) |
| Uniformity | ±2.0 °C (Temp), ±3.0% RH (Humidity) |
| Irradiance | 550 W/m² ±10% (300–800 nm), 1000 W/m² ±10% (300–1200 nm) |
| Xenon Lamp Power | 1.8 kW / 2.5 kW / 6 kW |
| Lamp Life | ≈1500 h |
| Spray Duration | 1–999 min (Intermittent or Continuous) |
| Spray Pressure | 70–127 kPa |
| Sample Holder | Dual-layer flat mesh rack or 500 mm diameter rotating turntable (0–3 rpm) |
| Construction | Interior – SUS304 stainless steel |
| Power Supply | AC 380 V ±5%, 50 Hz ±0.5 Hz |
| Brand | Other Brands |
|---|---|
| Origin | Imported |
| Manufacturer Type | General Distributor |
| Price | USD 5,300 (Reference Only) |
| Chamber Models | OK-XD-100 / OK-XD-225 / OK-XD-500 / OK-XD-1000 |
| Internal Dimensions (W×D×H, cm) | 50×50×40 / 50×75×60 / 80×80×80 / 100×100×100 |
| Temperature Range | 0–150°C (Chamber), 40–85°C (Black Panel) |
| Humidity Range | 20–75% RH (Light Cycle), 20–98% RH (Dark Cycle) |
| Temp. Control Accuracy | ±0.5°C |
| Humidity Control Accuracy | ±2.0% RH |
| Temp./RH Uniformity | ±2.0°C / ±3.0% RH |
| Spectral Range | 300–800 nm (550 W/m² ±10%) and 300–1200 nm (1000 W/m² ±10%) |
| Xenon Lamp Power | 1.8 kW / 2.5 kW / 6 kW |
| Lamp Life | ≈1,500 h |
| Spray Duration | 1–999 min (intermittent or continuous) |
| Spray Pressure | 70–127 kPa |
| Sample Mounting | Dual-layer flat mesh rack or 500 mm diameter rotating turntable (0–3 rpm) |
| Interior Material | SUS304 stainless steel |
| Exterior Material | SUS304 stainless steel or powder-coated steel |
| Power Supply | AC 380 V ±5%, 50 Hz ±0.5 Hz |
| Brand | Other Brands |
|---|---|
| Origin | Imported |
| Manufacturer Type | General Distributor |
| Price | USD 5,300 (Reference Only) |
| Chamber Models | OK-XD-100 / OK-XD-225 / OK-XD-500 / OK-XD-1000 |
| Internal Dimensions (W×D×H, cm) | 50×50×40 / 50×75×60 / 80×80×80 / 100×100×100 |
| External Dimensions (W×D×H, cm) | 100×170×90 / 110×190×100 / 140×190×130 / 165×210×150 |
| Temperature Range | 0–150°C (Chamber), 40–85°C (Black Panel) |
| Humidity Range | 20–75% RH (Light Cycle), 20–98% RH (Dark Cycle) |
| Temp. Control Accuracy | ±0.5°C |
| Humidity Control Accuracy | ±2.0% RH |
| Temp. Uniformity | ±2.0°C |
| Humidity Uniformity | ±3.0% RH |
| Irradiance | 550 W/m² ±10% (300–800 nm) or 1000 W/m² ±10% (300–1200 nm) |
| Xenon Lamp Power | 1.8 kW / 2.5 kW / 6 kW |
| Lamp Life | ~1,500 h |
| Spray Duration | 1–999 min (Intermittent or Continuous) |
| Spray Pressure | 70–127 kPa |
| Sample Mounting | Dual-layer mesh tray or 500-mm-diameter rotating turntable (0–3 rpm) |
| Construction | Interior – SUS304 stainless steel |
| Power Supply | AC 380 V ±5%, 50 Hz ±0.5 Hz |
| Brand | OK |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Price | USD 5,300–14,800 (FOB) |
| Temperature Range | 0–150°C (Chamber), 40–85°C (Black Panel) |
| Humidity Range | 20–98% RH |
| Irradiance | 550 W/m² ±10% (300–800 nm) / 1000 W/m² ±10% (300–1200 nm) |
| Lamp Power | 1.8 kW / 2.5 kW / 6 kW |
| Lamp Life | ≥1500 h |
| Spray Cycle | 1–999 min (intermittent or continuous) |
| Spray Pressure | 70–127 kPa |
| Sample Mounting | Dual-layer flat mesh rack or 500 mm rotary turntable (0–3 rpm) |
| Construction | Interior – SUS304 stainless steel |
| Compliance | GB/T 8427, GB/T 16422-2, GB/T 8430, ISO 4892-2, ASTM D529, GB/T 14576, GB/T 15102-2006, GB/T 15104-2006 |
| Brand | OEM / Other Brands |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Price | USD 5,300 (Reference Only) |
| Chamber Models | OK-XD-100 |
| Internal Dimensions (W×D×H, cm) | 50×50×40 |
| Temperature Range | 0–150°C (Chamber), 40–85°C (Black Panel) |
| Humidity Range | 20–75% RH (Light Cycle), 20–98% RH (Dark Cycle) |
| Temp. Control Accuracy | ±0.5°C |
| Humidity Control Accuracy | ±2.0% RH |
| Temp. Uniformity | ±2.0°C |
| Humidity Uniformity | ±3.0% RH |
| Irradiance | 550 W/m² ±10% (300–800 nm) or 1000 W/m² ±10% (300–1200 nm) |
| Xenon Lamp Power | 1.8 kW / 2.5 kW / 6 kW |
| Lamp Life | ≈1500 h |
| Spray Duration | 1–999 min (intermittent/continuous) |
| Spray Pressure | 70–127 kPa |
| Sample Mounting | Dual-layer flat mesh rack or 500 mm diameter rotating turntable (0–3 rpm) |
| Interior Material | SUS304 stainless steel |
| Exterior Material | SUS304 stainless steel or powder-coated steel |
| Power Supply | AC 380 V ±5%, 50 Hz ±0.5 Hz |
| Brand | Other Brands |
|---|---|
| Origin | Imported |
| Manufacturer Type | General Distributor |
| Price | USD 5,300 (approx.) |
| Chamber Models | OK-XD-100 / OK-XD-225 / OK-XD-500 / OK-XD-1000 |
| Internal Dimensions (cm) | 50×50×40 / 50×75×60 / 80×80×80 / 100×100×100 |
| Temperature Range | 0–150°C (chamber), 40–85°C (black panel) |
| Humidity Range | 20–75% RH (light cycle), 20–98% RH (dark cycle) |
| Control Accuracy | ±0.5°C / ±2.0% RH |
| Uniformity | ±2.0°C / ±3.0% RH |
| Spectral Range | 300–800 nm (550 W/m² ±10%) and 300–1200 nm (1000 W/m² ±10%) |
| Xenon Lamp Power | 1.8 kW / 2.5 kW / 6 kW |
| Lamp Life | ~1,500 h |
| Spray Duration | 1–999 min (intermittent or continuous) |
| Spray Pressure | 70–127 kPa |
| Sample Mounting | Dual-layer flat mesh rack or 500-mm-diameter rotating turntable (0–3 rpm) |
| Construction | Interior – SUS304 stainless steel |
| Power Supply | AC 380 V ±5%, 50 Hz ±0.5 Hz |
| Brand | OK |
|---|---|
| Model | OK-XD-100 / OK-XD-225 / OK-XD-500 / OK-XD-1000 |
| Chamber Type | Air-Cooled Long-Arc Xenon Lamp-Based Environmental Aging Test System |
| Light Spectrum | Full-Spectrum Solar Simulation (300–1200 nm) |
| Irradiance Control | 300–800 nm @ 550 W/m² ±10% |
| Black Panel Temperature Range | 40–85 °C |
| Chamber Temperature Range | 0–150 °C |
| Humidity Range | 20–98 % RH (dark cycle), 20–75 % RH (light cycle) |
| Humidity Accuracy | ±2.0 % RH |
| Temperature Accuracy | ±0.5 °C |
| Uniformity | ±2.0 °C (temp), ±3.0 % RH (humidity) |
| Xenon Lamp Power | 1.8 kW / 2.5 kW / 6 kW |
| Lamp Life | ~1500 h at nominal irradiance |
| Spray Function | Adjustable interval (1–999 min), continuous or intermittent, pressure 70–127 kPa |
| Sample Mounting | Dual-layer flat mesh rack or 500 mm diameter rotating drum (0–3 rpm) |
| Interior Material | SUS304 stainless steel |
| Exterior Material | SUS304 stainless steel or powder-coated steel |
| Power Supply | AC 380 V ±5%, 50 Hz ±0.5 Hz |
| Compliance Standards | GB/T 8427, GB/T 16422-2, GB/T 8430, ISO 4892-2, ASTM D529, GB/T 14576, GB/T 15102-2006, GB/T 15104-2006 |
| Brand | Other Brands |
|---|---|
| Origin | Imported |
| Manufacturer Type | General Distributor |
| Price | USD 5,300 (approx.) |
| Temperature Range | 0–150°C (chamber), 40–85°C (black panel) |
| Humidity Range | 20–75% RH (light cycle), 20–98% RH (dark cycle) |
| Irradiance | 550 W/m² ±10% (300–800 nm), 1000 W/m² ±10% (300–1200 nm) |
| Xenon Lamp Power | 1.8 kW / 2.5 kW / 6 kW |
| Lamp Life | ≈1500 h |
| Spray Duration | 1–999 min (intermittent or continuous) |
| Spray Pressure | 70–127 kPa |
| Sample Mounting | Dual-layer flat mesh rack or 500 mm diameter rotating turntable (0–3 rpm) |
| Construction | Interior – SUS304 stainless steel |
| Compliance | GB/T 8427, GB/T 16422-2, GB/T 8430, ISO 4892-2, ASTM D529, GB/T 14576, GB/T 15102-2006, GB/T 15104-2006 |
| Brand | OK Instruments |
|---|---|
| Model | OK-XD-100 / OK-XD-225 / OK-XD-500 / OK-XD-1000 |
| Chamber Interior Dimensions (W×D×H) | 50×50×40 cm to 100×100×100 cm |
| Temperature Range | 0–150°C (chamber), 40–85°C (black panel) |
| Humidity Range | 20–75% RH (light cycle), 20–98% RH (dark cycle) |
| Irradiance Control | 550 W/m² ±10% (300–800 nm), 1000 W/m² ±10% (300–1200 nm) |
| Xenon Lamp Power | 1.8 kW / 2.5 kW / 6 kW |
| Lamp Life | ≈1500 h |
| Spray Cycle | 1–999 min (intermittent or continuous) |
| Spray Pressure | 70–127 kPa |
| Sample Mounting | Dual-layer flat mesh rack or 500 mm diameter rotating turntable (0–3 rpm) |
| Construction | Interior – SUS304 stainless steel |
| Compliance | GB/T 8427, GB/T 16422-2, GB/T 8430, ISO 4892-2, ASTM D529, GB/T 14576, GB/T 15102-2006, GB/T 15104-2006 |
| Brand | Other Brands |
|---|---|
| Origin | Imported |
| Manufacturer Type | General Distributor |
| Price | USD 5,300 (approx.) |
| Temperature Range | 0–150°C (chamber), 40–85°C (black panel) |
| Humidity Range | 20–75% RH (light cycle), 20–98% RH (dark cycle) |
| Irradiance | 550 W/m² ±10% (300–800 nm), 1000 W/m² ±10% (300–1200 nm) |
| Xenon Lamp Power | 1.8 kW / 2.5 kW / 6 kW |
| Lamp Life | ~1,500 hours |
| Spray Duration | 1–999 min (intermittent or continuous) |
| Spray Pressure | 70–127 kPa |
| Sample Mounting | Dual-layer flat mesh rack or 500 mm diameter rotating turntable (0–3 rpm) |
| Internal Dimensions (cm) | 50×50×40 (OK-XD-100) to 100×100×100 (OK-XD-1000) |
| Construction | Interior — SUS304 stainless steel |
| Control Accuracy | ±0.5°C (temperature), ±2.0% RH (humidity) |
| Uniformity | ±2.0°C (temperature), ±3.0% RH (humidity) |
| Compliance Standards | GB/T 8427, GB/T 16422-2, ISO 4892-2, ASTM D529, GB/T 14576, GB/T 15102-2006, GB/T 15104-2006 |
| Brand | Other Brands |
|---|---|
| Origin | Imported |
| Manufacturer Type | General Distributor |
| Price | USD 5,300 (approx.) |
| Internal Dimensions (cm) | 50×50×40 / 50×75×60 / 80×80×80 / 100×100×100 |
| Temperature Range | 0–150°C (chamber), 40–85°C (black panel) |
| Humidity Range | 20–75% RH (light cycle), 20–98% RH (dark cycle) |
| Control Accuracy | ±0.5°C / ±2.0% RH |
| Uniformity | ±2.0°C / ±3.0% RH |
| Irradiance | 550 W/m² ±10% (300–800 nm) or 1000 W/m² ±10% (300–1200 nm) |
| Xenon Lamp Power | 1.8 kW / 2.5 kW / 6 kW |
| Lamp Life | ~1500 h |
| Spray Duration | 1–999 min (intermittent or continuous) |
| Spray Pressure | 70–127 kPa |
| Sample Mounting | Dual-layer flat mesh rack or 500-mm-diameter rotating drum (0–3 rpm) |
| Construction | Interior – SUS304 stainless steel |
| Power Supply | AC 380 V ±5%, 50 Hz ±0.5 Hz |