Fermentation Analyzer
Filter
Showing all 4 results
| Brand | TMAXTREE |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Fully Automatic |
| Detection Method | Enzyme-Linked Electrode Sensor Array |
| Measurable Analytes | Glucose, Lactose, Galactose, Glutamic Acid, Glutamine, Lysine, Xylose, Glycerol, Lactic Acid, Ethanol, Methanol |
| Accuracy | <3% Full Scale |
| Sample Throughput | 50 samples/hour |
| Dimensions | 550 × 502 × 760 mm |
| Brand | FOREVERGEN |
|---|---|
| Model | OE |
| Instrument Type | Fully Automated |
| Detection Method | Visible Light Absorption Spectroscopy |
| Measured Gases | CO₂, O₂ |
| Accuracy | ≤ ±1–2% of Full Scale |
| Dimensions (W×D×H) | 430 × 350 × 120 mm |
| Brand | TCT (Xiamen Tongchuang) |
|---|---|
| Origin | Fujian, China |
| Instrument Type | Fully Automated |
| Detection Method | NDIR (CO₂, CH₄), NDUV (H₂S), Electrochemical or PMD Paramagnetic (O₂) |
| Measured Gases | CO₂, O₂, CH₄, H₂S |
| Accuracy | ≤ ±1.5% of reading or ±0.2% FS (CO₂/CH₄), ≤ ±1.5% of reading or ±1% FS (H₂S) |
| Zero Drift | CO₂ ≤ ±0.1%/8h |
| Span Drift | CO₂ ≤ ±0.1% FS/8h |
| Repeatability | CO₂ ≤ ±1% FS |
| Linearity | 0.99 ≤ slope ≤ 1.01 |
| Response Time (T90) | < 3 s (at inlet) |
| Sampling Frequency | 1 Hz |
| Gas Conditioning | Integrated electronic cooler (4–5°C), particulate filter, flow meter, condensate detection |
| Output | Standard Modbus RTU (RS-485), optional analog (0–5 V / 4–20 mA) |
| Channels | Configurable 1–12 multi-tank sequential sampling |
| Dimensions (W×H×D) | 450 mm × 370 mm × 310 mm |
| Weight | ~20 kg (EC-4 configuration) |
| Operating Temperature | 5–45 °C |
| Storage Temperature | −25 to +65 °C |
| Relative Humidity | ≤95% RH (non-condensing) |
| Power Supply | 230 V AC |
| Warm-up Time | < 1 h (at 20 °C) |
| Ingress Protection | IP20 |
| Brand | TCT |
|---|---|
| Model | Ferment500 |
| Origin | Fujian, China |
| Instrument Type | Fully Automatic |
| Detection Method | Gas Sensing (Thermal Conductivity for CO₂ |
| Measured Parameters | CO₂, O₂, CER, OUR, RQ |
| Accuracy | ≤ ±1.5% FS |
| Sampling Frequency | ≥1 Hz |
| Dimensions | 355 mm × 195 mm × 436 mm |
| Channel Architecture | Four Independent Physical Channels with Dedicated Sensors |
| Environmental Compensation | Integrated Temperature, Humidity & Pressure Compensation |
| Gas Pre-treatment | Built-in Condensation-Based Moisture and Foam Removal System |
| Display | High-Resolution Touchscreen LCD |
| Calibration | Per-Channel Single-Point Calibration |
| Connectivity | Optional Ethernet/Wi-Fi with OTA Firmware Updates, Remote Diagnostics, Alarm Notification, Predictive Maintenance Logging |
