Flame Photometer
Filter
Showing all 25 results
| Brand | AOE |
|---|---|
| Model | 6400A |
| Origin | Shanghai, China |
| Type | Benchtop Flame Emission Spectrometer |
| Detection Elements | K, Na, Li, Ca, Ba |
| Optical System | Interference Filter-Based Monochromator |
| Detector | Silicon Photocell |
| Display | LCD |
| Sample Uptake Rate | <6 mL/min |
| Response Time | <8 s |
| Stability (15 s) | ≤3% RSD |
| Stability (6 min, 6 readings) | ≤15% RSD |
| Repeatability | ≤3% RSD |
| Linearity Error | K: ≤0.005 mmol/L (0.0100–0.0800 mmol/L) |
| Na | ≤0.03 mmol/L (0.0500–0.400 mmol/L) |
| Detection Limit | K: ≤0.004 mmol/L |
| Na | ≤0.008 mmol/L |
| Potassium Filter | Peak Wavelength Tolerance ≤±7 nm, FWHM ≤15 nm, Background Transmittance ≤0.5% |
| Sodium Filter | Peak Wavelength Tolerance ≤±5 nm, FWHM ≤15 nm, Background Transmittance ≤0.5% |
| Measurement Range | K: 0–100 µg/mL |
| Na | 0–160 µg/mL |
| Li | 0–100 µg/mL |
| Ca | 0–100 µg/mL |
| Ba | 0–3000 µg/mL |
| Brand | AOE |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | FP640 |
| Price Range | USD 720–1,430 (FOB Shanghai) |
| Stability (15 s) | ≤3% RSD |
| Stability (6 min, 1-min interval) | ≤15% RSD |
| Repeatability | ≤3% RSD |
| Linearity Error | K: ≤0.005 mmol/L (0.0100–0.0800 mmol/L) |
| Na | ≤0.03 mmol/L (0.0500–0.400 mmol/L) |
| Detection Limit | K: ≤0.004 mmol/L |
| Na | ≤0.008 mmol/L |
| K Interference Filter | Peak Wavelength Tolerance ≤±7 nm |
| Na Interference Filter | Peak Wavelength Tolerance ≤±5 nm |
| Filter Bandwidth (FWHM) | ≤15 nm for both K and Na filters |
| Background Transmittance | ≤0.5% |
| Response Time | <8 s |
| Sample Aspiration Rate | <6 mL/min |
| Display | LCD with integrated parameter readout |
| Optical System | Fixed-wavelength interference filters |
| Detector | Silicon photodiode |
| Measurement Range (as elemental concentration) | K: 0–100 µg/mL |
| Na | 0–160 µg/mL |
| Li | 0–100 µg/mL |
| Ca | 0–100 µg/mL |
| Ba | 0–3000 µg/mL |
| Brand | AOE |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | FP6410 |
| Price Range | USD 1,400–2,800 |
| Stability (15 s) | ≤3% RSD |
| Stability (6 min, 1-min interval) | ≤15% RSD |
| Repeatability | ≤3% RSD |
| Linearity Error | K ≤0.005 mmol/L (0.0100–0.0800 mmol/L) |
| Detection Limit | K ≤0.004 mmol/L |
| Filter Peak Wavelength Tolerance | K ≤7 nm |
| Filter Bandwidth (FWHM) | ≤15 nm (K & Na) |
| Filter Background Transmittance | ≤0.5% |
| Response Time | <8 s |
| Sample Aspiration Rate | <6 mL/min |
| Display | LCD |
| Optical Filtering | Interference Filters |
| Photodetector | Silicon Photocell |
| Measurement Range | K: 0–100 µg/mL |
| Na | 0–160 µg/mL |
| Li | 0–100 µg/mL |
| Ca | 0–100 µg/mL |
| Ba | 0–3000 µg/mL |
| Brand | AOPU |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Model | AP1200 |
| Measurement Range | K: 0–100 µg/mL |
| Na | 0–100 µg/mL |
| Detection Limit | K ≤ 0.004 mmol/L |
| Response Time | < 8 s |
| Repeatability | ≤ 3% |
| Sample Uptake Rate | < 6 mL/min |
| Brand | AOPU |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Model | AP1301 |
| Measurement Range | K: 0–100 µg/mL |
| Na | 0–100 µg/mL |
| Li | 0–100 µg/mL |
| Detection Limit | K ≤ 0.004 mmol/L |
| Response Time | < 8 s |
| Repeatability | ≤ 3% |
| Sample Uptake Rate | < 6 mL/min |
| Brand | AOPU |
|---|---|
| Origin | Shanghai, China |
| Manufacturer | AOPU Instrument Co., Ltd. |
| Model | AP1302 |
| Detection Elements | K, Na, Ca |
| Measurement Range | K: 0–100 µg/mL |
| Na | 0–100 µg/mL |
| Ca | 0–1000 µg/mL |
| Detection Limit | K ≤ 0.004 mmol/L |
| Response Time | < 8 s |
| Repeatability | ≤ 3% |
| Sample Uptake Rate | < 6 mL/min |
| Optical System | Interference filter-based monochromator with three dedicated channels (K, Na, Ca) |
| Detector | Silicon photovoltaic cell |
| Calibration Modes | Linear, segmented linear, and quadratic polynomial fitting |
| Stability | ≤ 3% RSD over 15 s |
| Linearity Error | K ≤ 0.005 mmol/L |
| Ignition System | One-touch electronic ignition with flame-ionization safety cutoff and auto-alarm (8 s timeout) |
| Interface | RS232 serial port for PC or printer connectivity |
| Dimensions | 440 × 310 × 500 mm |
| Weight | 12.5 kg |
| Power Supply | 220 V ± 22 V, 50 Hz ± 1 Hz, 250 W |
| Operating Environment | 10–35 °C, RH ≤ 85%, vibration-free, non-corrosive, non-explosive atmosphere |
| Brand | AOPU |
|---|---|
| Origin | Shanghai, China |
| Manufacturer | AOPU Instrument Co., Ltd. |
| Model | AP1401 |
| Detection Range | K: 0–100 µg/mL |
| Na | 0–100 µg/mL |
| Li | 0–100 µg/mL |
| Ca | 0–1000 µg/mL |
| Detection Limits | K ≤ 0.004 mmol/L |
| Response Time | < 8 s |
| Repeatability | ≤ 3% RSD |
| Sample Aspiration Rate | < 6 mL/min |
| Brand | AOPU |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Model | AP1402 |
| Detection Range | K: 0–100 µg/mL |
| Na | 0–100 µg/mL |
| Li | 0–100 µg/mL |
| Ba | 0–3000 µg/mL |
| Detection Limit | K ≤ 0.0004 mmol/L |
| Response Time | < 8 s |
| Repeatability | ≤ 3% |
| Sample Uptake Rate | < 6 mL/min |
| Brand | AOPU |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Model | AP1500 |
| Detection Range | K: 0–100 µg/mL |
| Na | 0–100 µg/mL |
| Li | 0–100 µg/mL |
| Ca | 0–1000 µg/mL |
| Ba | 0–3000 µg/mL |
| Detection Limit | K ≤ 0.004 mmol/L |
| Response Time | < 8 s |
| Repeatability | ≤ 3% |
| Sample Aspiration Rate | < 6 mL/min |
| Brand | AOPU |
|---|---|
| Origin | Shanghai, China |
| Manufacturer | AOPU Instrument Co., Ltd. |
| Model | AP1500 GMP Edition |
| Detection Range | K: 0–100 µg/mL |
| Na | 0–100 µg/mL |
| Li | 0–100 µg/mL |
| Ca | 0–1000 µg/mL |
| Ba | 0–3000 µg/mL |
| Detection Limits | K ≤ 0.004 mmol/L |
| Response Time | < 8 s |
| Repeatability | ≤ 3% RSD |
| Sample Uptake Rate | < 6 mL/min |
| Brand | AOPU |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Region Classification | Domestic (China) |
| Model | FP640 |
| Price | USD 1,280 (FOB Shanghai) |
| Measurement Range | K: 0–100 µg/mL |
| Na | 0–100 µg/mL |
| Detection Limit | K ≤ 0.004 mmol/L |
| Response Time | < 8 s |
| Repeatability | ≤ 3% RSD |
| Sample Uptake Rate | < 6 mL/min |
| Detector | Silicon Photocell |
| Wavelength Selection | Interference Filter |
| Display | 7-inch Color Touchscreen |
| Ignition System | One-Touch Auto-Ignition with Flame Ionization Safety Cut-off |
| Fuel Compatibility | Liquefied Petroleum Gas (LPG), Propane, or Butane |
| Linear Error | K ≤ 0.005 mmol/L |
| Stability | ≤ 3% max variation within 15 s |
| Operating Environment | 10–35 °C, RH ≤ 85%, Stable Horizontal Surface, No Strong EMI/Vibration, Proper Grounding, 220 V ± 10%, 50 Hz ± 1 Hz, 250 W Max |
| Dimensions | 400 × 250 × 500 mm |
| Weight | 12.5 kg |
| Standard Configuration | Main Unit, Integrated Air Compressor, Calibration Standards, Capillaries, Filters, User Manual, and Safety Accessories |
| Brand | AOPU |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Model | FP6400A |
| Measurement Range | K: 0–100 µg/mL |
| Na | 0–100 µg/mL |
| Detection Limit | K ≤ 0.004 mmol/L |
| Response Time | < 8 s |
| Repeatability | ≤ 3% |
| Sample Uptake Rate | < 6 mL/min |
| Detector | Silicon Photocell |
| Wavelength Selection | Interference Filter |
| Display | 7-inch Color Touchscreen |
| Ignition System | One-Touch Ignition with Flame Ionization Safety Cut-off |
| Fuel Compatibility | Liquefied Petroleum Gas (LPG), Propane, or Butane |
| Linear Error | K ≤ 0.005 mmol/L |
| Stability | ≤ 3% RSD over 15 s |
| Operating Environment | 10–35 °C, RH ≤ 85%, Stable Horizontal Surface, Grounded 220 V ± 10%, 50 Hz ± 1 Hz, 250 W Max |
| Dimensions | 400 × 250 × 500 mm |
| Weight | 12.5 kg |
| Brand | AOPU |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Classification | Domestic (China) |
| Model | FP650 |
| Measurement Range | K: 0–100 µg/mL |
| Na | 0–100 µg/mL |
| Detection Limit | K ≤ 0.004 mmol/L |
| Response Time | < 8 s |
| Repeatability | ≤ 3% |
| Sample Uptake Rate | < 6 mL/min |
| Brand | ATS |
|---|---|
| Origin | Switzerland |
| Model | ATS 200S |
| Detection Elements | Na, K, Li, Ca (standard) |
| Measurement Range | Na/K/Li/Ca: 0–200 ppm |
| Ba | 50–1000 ppm |
| Units | ppm, mmol/L, mEq/L |
| Sensitivity | 0.4 ppm (Na, K) |
| Detection Limit | 0.2 ppm (Na, K) |
| Linearity | Natural logarithmic linearity (R² > 0.999 over full range) |
| Repeatability | ≤1% CV (n=10) |
| Drift | ≤1% over 30 min |
| Calibration | One-touch auto-zero and multi-point calibration |
| Operating Temperature | 15–36 °C |
| Relative Humidity | ≤85% RH (non-condensing) |
| Dimensions (Analyzer) | 320 × 400 × 400 mm (L×W×H) |
| Net Weight (Analyzer) | 9 kg |
| Air Compressor Dimensions | 340 × 250 × 350 mm |
| Net Weight (Compressor) | 6 kg |
| Compliance | CE, RoHS, ISO/IEC 17025-compatible operation |
| Software Interface | USB 2.0, RS-232, optional Ethernet module |
| Brand | ATS |
|---|---|
| Origin | Switzerland |
| Model | ATS 200S/40998 |
| Measurement Principle | Atomic Emission Spectrometry (Flame Photometry) |
| Elements Measured (Standard) | Na, K, Ca, Mg |
| Optional Channels | Ba or custom single-element channel |
| Measurement Units | ppm, mmol/L, mEq/L |
| Linear Range | Na/K/Ca 0–200 ppm |
| Detection Limit | 0.2 ppm (Na, K) |
| Sensitivity | 0.4 ppm (Na, K) |
| Precision | ≤1% CV (n=10) |
| Drift | ≤1% over 30 min |
| Fuel Gases | Butane, Propane, LPG |
| Air Supply | Oil-free, water-free, particle-free compressed air with buffer tank |
| Optical Design | Fixed interference filters (non-movable) |
| Calibration | Automatic zeroing + single-point memory calibration |
| Software | ATS MiniSoftWin™ (GLP-compliant reporting, multi-point calibration curve generation, method/data archiving, ISO/IEC 17025 report templates) |
| Brand | CloudOptek |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Domestic (PRC) |
| Model | MFP-600 |
| Detection Range | Organophosphorus agents (G- and V-series nerve agents), sulfur-containing agents (HD, HL vesicants), nitrogen/hydrogen/oxygen-containing agents (HN, AC), arsenical agents (L, SA), and combustible gases (CH) |
| Detection Limits | ≤0.05 µg/L for Sarin (GB), ≤10.00 µg/L for Hydrocyanic Acid (AC), ≤5 µg/L for Lewisite (L), ≤1 µg/L for Sulfur Mustard (HD) |
| Response Time | 2–60 seconds (agent-dependent) |
| Brand | Shanda |
|---|---|
| Model | SD-FP7450 |
| Origin | Shandong, China |
| Detection Elements | K, Na, Li, Ca, Ba |
| Number of Channels | 5 |
| Measurement Range | 0.000–999.9 / 0–65535 (arbitrary units) |
| Detection Limits (mmol/L) | K ≤ 0.004, Na ≤ 0.008, Li ≤ 0.015, Ca ≤ 0.050, Ba ≤ 0.044 |
| Linearity Error (mmol/L) | K ≤ 0.005, Na ≤ 0.03, Li ≤ 0.021, Ca ≤ 0.075, Ba ≤ 0.066 |
| Response Time | ≤ 8 s |
| Nebulization Rate | < 6 mL/min |
| Stability | ≤ 3% RSD over 15 s |
| Repeatability | ≤ 3% RSD |
| Display | 7-inch capacitive color touchscreen |
| Output | Concentration values and relative emission intensity |
| Data Output | Built-in Bluetooth thermal printer, USB interface, optional PC software |
| Graphical Display | Real-time calibration curve and signal trend plotting |
| Compliance | Designed for routine quantitative analysis in accordance with ISO 11097:2010 (Water quality — Determination of sodium and potassium — Flame photometric method) and ASTM D1293 (Standard Test Methods for Electrical Conductivity and pH of Water) |
| Brand | INESA |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | FP6410 / FP640 / 6400A |
| Price | Upon Request |
| Measurement Range | 0–100 ppm |
| Response Time | < 8 s |
| Repeatability | ≤2% |
| Sample Flow Rate | < 4 mL/min |
| Brand | Sherwood |
|---|---|
| Origin | United Kingdom |
| Model | M410 |
| Element Detection | Na, K, Li, Ca, Ba |
| Output Units | ppm, mg/L |
| Compliance | ISO 7635, ASTM D2189, USP <731> |
| Software Interface | RS-232 serial output for data logging |
| Brand | Tianyan |
|---|---|
| Origin | Shandong, China |
| Manufacturer | Tianyan Instrument Co., Ltd. |
| Model | TY-FP640 |
| Response Time | < 8 s |
| Repeatability | ≤ 3% |
| Detection Principle | Flame Emission Spectroscopy (FES) |
| Detector | Silicon Photocell |
| Wavelength Selection | Interference Filter |
| Display | 3-digit LED |
| Stability (15 s) | ≤ 3% RSD |
| Stability (6 min, 6 readings) | ≤ 15% RSD |
| Linearity Error | K ≤ 0.005 mmol/L |
| Sample Aspiration Rate | < 6 mL/min |
| Operating Temperature | 10–35 °C |
| Relative Humidity | ≤ 85% RH |
| Power Supply | 220 V ± 22 V, 50 Hz ± 1 Hz, Grounded |
| Rated Power | 250 W |
| Dimensions (W×D×H) | 400 × 250 × 500 mm |
| Weight | 12.5 kg |
| Standard Configuration | Main unit, air compressor, accessories & spare parts |
| Brand | Yoke |
|---|---|
| Origin | Shanghai, China |
| Model | FP6431 |
| Detection Elements | K, Na, Ca |
| Detection Limits | K: 0.001 mmol/L |
| Na | 0.001 mmol/L |
| Ca | 0.01 mmol/L |
| Response Time | ≤5 s |
| Repeatability | RSD ≤1.5% |
| Sample Flow Rate | 6–8 mL/min |
| Display | 7-inch capacitive touch LCD |
| Data Export | USB port & U-disk support |
| Safety Features | Flame-out protection & gas leakage alarm |
| Operating Temperature | 10–35 °C |
| Relative Humidity | ≤85% RH |
| Power Supply | AC 220 V ±10%, 50 Hz, 250 W |
| Brand | Yoke |
|---|---|
| Origin | Shanghai, China |
| Model | FP6432 |
| Measurement Range | K: 0–100 µg/mL |
| Na | 0–100 µg/mL |
| Ba | 0–3000 µg/mL |
| Detection Limit | K ≤ 0.004 mmol/L |
| Response Time | < 8 s |
| Repeatability | ≤ 3% |
| Sample Flow Rate | < 6 mL/min |
| Wavelength Accuracy | K/Li/Ca/Ba ≤ ±7 nm |
| Bandwidth (FWHM) | ≤ 15 nm for all elements |
| Background Transmittance | ≤ 0.5% |
| Power Supply | AC 220 ± 22 V, 50 ± 1 Hz |
| Rated Power | 30 W |
| Display | 7-inch capacitive touch LCD |
| Data Storage | 10-point calibration curves (max), 200 sample records |
| Connectivity | USB port, U-disk export, cloud-enabled interface |
| Safety Features | Flame-out detection, gas leak alarm |
| Brand | Yoke |
|---|---|
| Origin | Shanghai, China |
| Model | FP6440 |
| Detection Elements | K, Na, Li, Ca |
| Detection Limits | K: 0.001 mmol/L |
| Na | 0.001 mmol/L |
| Li | 0.005 mmol/L |
| Ca | 0.01 mmol/L |
| Response Time | <8 s |
| Repeatability | RSD ≤1.5% |
| Nebulization Flow Rate | 6–8 mL/min |
| Display | 7-inch capacitive touch LCD |
| Safety Features | Flame-out protection, gas leakage alarm |
| Data Interface | USB port, U-disk export, PC connectivity |
| Cloud Connectivity | Yes |
| Calibration Function | Automatic correlation coefficient calculation |
| Optional Accessory | Thermal printer |
| Brand | Yoke |
|---|---|
| Origin | Shanghai, China |
| Model | FP6450 |
| Detection Elements | K, Na, Li, Ca, Ba |
| Detection Limits | K: 0.001 mmol/L |
| Na | 0.001 mmol/L |
| Li | 0.005 mmol/L |
| Ca | 0.01 mmol/L |
| Ba | 0.02 mmol/L (typical) |
| Response Time | <8 s |
| Repeatability | RSD ≤1.5% |
| Sample Uptake Rate | 6–8 mL/min |
| Display | 7-inch capacitive touchscreen LCD |
| Data Storage | Up to 10-point calibration curves and 200 sample results |
| Connectivity | USB port, USB flash drive export, cloud-enabled data synchronization |
| Safety Features | Automatic flame-out detection, gas leak alarm |
| Calibration Modes | Linear and piecewise linear (broken-line) |
| Power Supply | AC 220 V ±10%, 50 Hz ±1 Hz |
| Rated Power | 30 W |
| Printer | Optional external thermal printer |
| Brand | Youyunpu |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic Flame Photometer |
| Model | YP-32 |
| Price | USD 1,450 (FOB Qingdao) |