Flame Retardancy Tester
Filter
Showing all 14 results
| Brand | Aerospace |
|---|---|
| Origin | Beijing, China |
| Model | TFR-1 |
| Dimensions (W×D×H) | 1160 mm × 600 mm × 1310 mm (including feet) |
| Sample Holder | Anthropomorphic Metallic Headform (1:1 scale) |
| Flame Temperature Range | 750–950 °C |
| Headform Travel Speed | (60 ± 5) mm/s |
| Afterflame Timing Resolution | 0.1 s |
| Power Supply | 220 V, 50 Hz, 150 W |
| Fuel Compatibility | Propane, Liquefied Petroleum Gas (LPG), or ≥98% Methane |
| Compliance Standards | GB 2626, GB 19082, GB 19083, GB/T 32610, YY 0469, YY/T 0969 |
| Brand | Aerospace |
|---|---|
| Origin | Beijing, China |
| Model | WCF-1 |
| Dimensions (L×W×H) | 700 × 400 × 720 mm |
| Weight | ~30 kg |
| Power Supply | AC 220 V ±10%, 50 Hz, 100 W |
| Gas Source | Natural gas or LPG |
| Ignition Temperature Control | 310 °C ±10 °C |
| Timing Accuracy | ±0.1 s (within 3 min) |
| Repeatability Error | ±0.1% (mass loss) |
| Sample Form | Solid wood specimens |
| Specimen Dimensions | 76 × 13 × 13 mm (±1 mm) |
| Conditioning | 23 ±2 °C, 50 ±5% RH until mass change <1% over 24 h |
| Compliance | GA/T 42.1–2003 “Test Method for Combustion Performance of Flame-Retardant Wood — Pile-Burning Method” |
| Origin | Guangdong, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | DELTA1111 |
| Quotation | Available upon Request |
| Test Standards | ISO 6925, CFR 1630/1631, BS 6307, BS 4790, GB/T 20394–2013, GB/T 11049–2008, GB/T 14768–2015 |
| Sample Size | 230 mm × 230 mm (8 specimens per test) |
| Heating Source | Hot Metal Nut Method & Hexamethylenetetramine (Urotropine) Pellet Method |
| Ignition | Automatic Pulse Ignition |
| Timing Range | Flame Application Time: 0–99 s/min |
| Flame Application & Withdrawal Interval | 1.0–999.9 s (digital preset) |
| Afterflame Time | 1.0–999.9 s (digital readout) |
| Repetition Cycles | 1–9999 (digital preset) |
| Test Chamber Dimensions | 300 mm × 300 mm × 300 mm (W×D×H) |
| Ventilation Hood Volume | 2 m³ with Auto-Exhaust & Explosion-Proof Lighting |
| Exhaust Duct Diameter | Ø110 mm |
| Control System | PLC + 7-inch HMI Touchscreen |
| Power Supply | AC 220 V ±10%, 50 Hz |
| Stainless Steel Hot Plate | 230 mm × 230 mm × 6.5 ±0.5 mm, central aperture Ø205 mm |
| Desiccant | Color-Indicating Silica Gel GPE0038 |
| Safety Features | Interlocked Protective Door, Black Interior Finish, Observation Window with Integrated LED Illumination |
| Brand | Aerospace Vertical |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | HAG-Type |
| Price Range | USD 6,000 – 10,000 (FOB) |
| Application | Halogen acid gas quantification in flame-retardant cables |
| Sample Form | Solid wire & cable specimens |
| pH Repeatability | ±0.02 pH units |
| Combustion Boat | Fused quartz tube, 100 mm × 25 mm × 10 mm (L × W × D) |
| Air Filtration | Activated carbon + silica gel dual-stage drying & purification |
| Thermocouple | K-type, 0–1300 °C, stainless-steel sheathed |
| Heating Furnace | 600 mm effective length × Ø42 mm ID, 10 kW electric heating, PID-controlled |
| Gas Collection | Dual 500 mL absorption flasks |
| Air Flow Control | 20–200 mL/min adjustable rotameter |
| Power Supply | 220 V AC, 30 A |
| Conductivity Range | 0–1×10⁵ µS/cm |
| pH Measurement Range | 0–14, resolution 0.01 pH |
| Brand | Netzsch |
|---|---|
| Origin | Germany |
| Model | KBT Cable Fire Testing System |
| Standards Compliance | EN 50399, IEC 60332-3, GB/T 31248, GB/T 18380.31, IEC 60332-3-10 |
| Chamber Dimensions (W × D × H) | 135 × 235 × 430 cm |
| Exhaust Opening (W × D) | 100 × 30 cm |
| Fume Hood Dimensions (H × W × D) | 100 × 150 × 100 cm |
| Temperature Measurement Range | −100 to 1300 °C, Resolution: 0.1 K |
| Mass Flow Controller Range | 0–1 L/min, Accuracy: ±0.3 L/min |
| Paramagnetic O₂ Analyzer | 16–21 % (v/v), Max. Resolution: 0.001 % |
| NDIR CO₂ Analyzer | 0–10 % (v/v) |
| Peltier Condenser | Min. Temp. −10 °C, Dryer-Free Operation |
| Gas Sampling Probes | High-Precision Bidirectional |
| Control System | Siemens Gas Analyzers with Auto-Calibration & Dual-Direction Data Exchange |
| Brand | NETZSCH |
|---|---|
| Origin | Germany |
| Model | SBI Single Burning Item Test System |
| Compliance | EN 13823, GB/T 20284, GB/T 20248 |
| Sample Configuration | Two perpendicular non-flooring building material specimens mounted on a trolley |
| Ignition Source | Sand-boxed J-type burner |
| Exhaust Duct | Ø(315 ± 5) mm |
| Mass Flow Controller Range | >0–2.1 g/s, accuracy better than ±1.5% of reading |
| Burner Switching Response Time | ≤12 s |
| Oxygen Analyzer | Paramagnetic, 16–21% (v/v), resolution 0.001% |
| CO₂ Analyzer | NDIR, 0–10% (v/v) |
| Smoke Measurement | White-light or laser-based optical density system |
| Cooling | Peltier-cooled gas conditioning unit |
| Data Acquisition | Integrated modular control and acquisition platform |
| Interface | High-resolution color touchscreen HMI |
| Gas Analysis | Siemens OEM analyzer with bidirectional communication and auto-calibration capability |
| Brand | Netzsch |
|---|---|
| Origin | Germany |
| Model | TFP External Cladding Fire Test System |
| Standards Compliance | DIN 4102-20, ONORM B3800-5, BS 8414-1 |
| Combustion Chamber Base | Stainless steel roller bed with gravel fill, non-return valve, ignition system, and flame detection sensor |
| Exhaust System | Radial exhaust fan with mass-flow control (0–200 L/min), stainless steel exhaust hood and collector |
| Cooling | Peltier cooler (down to −10 °C) |
| Gas Analysis | Siemens paramagnetic O₂ analyzer (16–21% v/v, resolution 0.001%), NDIR CO₂ analyzer (0–10% v/v) |
| Temperature Measurement | −100 °C to 1300 °C, resolution 0.1 K, cold-junction compensation |
| Pressure Differential Sensor | 0–20 Pa, accuracy ±1% |
| Propane Mass Flow Controller | 0–0.5 kg/min |
| Measurement Tube | Stainless steel, Ø600 mm |
| Control Unit | Integrated single-board computer with 10.1″ color touchscreen interface for real-time monitoring and automated reporting |
| Brand | Netzsch |
|---|---|
| Origin | Germany |
| Model | TNB Non-Combustibility Furnace |
| Compliance | ISO 1182, EN 13501-1, GB 8624 |
| Chamber Material | Stainless Steel |
| Viewing Mirror | 300 × 320 mm, 30° tilt |
| Thermocouple Type | Armored N- or K-type |
| Temperature Range | Up to 1300 °C |
| Resolution | 0.1 K with Cold-Junction Compensation |
| Integrated Control Unit | Single-board computer with 32 GB SSD |
| Data Interface | USB and Ethernet |
| Heating Control | Digital linear ramping with real-time monitoring |
| Brand | Netzsch |
|---|---|
| Origin | Germany |
| Model | TSP Smoldering Test Apparatus |
| Compliance Standard | DIN EN 16733 |
| Sample Dimensions | 800 mm (L) × 300 mm (W) × ≤100 mm (T) |
| Sample Holder Material | Stainless Steel |
| Thermocouple Type | K-type NiCr–Ni armored |
| Ambient Operating Temperature | +20 ± 10 °C |
| Fire Suppression Plate Material | Calcium Silicate |
| Gas Control | Front-mounted main gas valve and pressure regulator |
| Flow Control | Adjustable flow restrictor and variable-area rotameter |
| Safety Features | Integrated flame-quenching plate with certified thermal inertia |
| Brand | Netzsch |
|---|---|
| Origin | Germany |
| Model | UL94 Vertical/Horizontal Flame Chamber |
| Standards Compliance | UL 94 (5th Ed.), IEC/EN 60695-11-10, -11-20, -11-3, -11-4, ISO 9773 |
| Sample Dimensions (Strip) | 125.0 ± 5.0 mm × 13.0 ± 0.5 mm |
| Sample Dimensions (Sheet) | ≥150.0 ± 5.0 mm × ≥150.0 ± 5.0 mm |
| Burner Power | 50 W / 500 W |
| Burner Tilt Angles | 0°, 20°, 45° |
| Touchscreen Interface | 10" High-Resolution Capacitive Display |
| Enclosure Material | Sandblasted Stainless Steel (AISI 304) |
| Integrated Control Unit | Embedded Industrial PC with 32 GB SSD Storage |
| Brand | Peiyi |
|---|---|
| Origin | Shanghai, China |
| Model | PY-NS01 |
| Ignition Source | Liquefied Petroleum Gas (LPG) or Town Gas |
| Burner Inner Diameter | 9.5 ± 0.5 mm, Length: ~100 mm |
| Adjustable Flame Height | 20–100 mm |
| Flame Application Time Range | 0–99 min 99 sec |
| Chamber Volume | 0.05 m³ |
| Chamber Material | Stainless Steel or Powder-Coated Steel |
| Power Supply | AC 220 V, 50 Hz, 5 A |
| Compliance | GB 8410–2006, FMVSS 302, ISO 3795, ASTM D5132 |
| Brand | Peiyi |
|---|---|
| Origin | Shanghai, China |
| Model | PY-LD07 |
| Chamber Volume | ≥0.5 m³ |
| Test Voltage Range | 100–600 V AC |
| Electrode Force | 1.0 N ± 0.05 N |
| Electrode Material | Platinum |
| Droplet Volume | 44–50 drops/cm³ |
| Droplet Height Adjustment | 30–40 mm |
| Droplet Interval | 30 ± 5 s |
| Short-Circuit Current Threshold | ≥0.5 A (cut-off after 2 s) |
| Voltage Drop Limit | ≤10% at 1 A ± 0.1 A |
| Power Supply | AC 220 V / 50 Hz |
| Construction | Stainless Steel & Brass Housing |
| Compliance | IEC 60112, IEC 60335-1, GB/T 4207, GB 4706.1, GB 2099.1, VDE 0620 |
| Brand | TESTech |
|---|---|
| Model | TTech-GBT18380B |
| Origin | Jiangsu, China |
| Manufacturer Type | Direct Manufacturer |
| Compliance Standards | GB/T 18380.31–36, IEC 60332-3-10, UL 1685, EN 50399, KS C IEC 60332-3-21 to -25 (Classes A–D), IEEE 383 (with 20° burner tilt option) |
| Test Chamber Dimensions | 1,000 ± 100 (W) × 2,000 ± 100 (D) × 4,000 ± 100 (H) mm |
| Airflow Rate | (5,000 ± 500) L/min |
| Propane Burner | 257 mm × 4.5 mm ribbon-type, 242 × Ø1.35 mm orifices in triple-row configuration (81/80/81), 3.2 mm pitch |
| Gas Supply | Technical-grade propane (≥95% purity), regulated at 100 kPa @ 20 °C |
| Ignition | Automatic spark ignition |
| Control System | PLC-based with 10.1″ industrial touchscreen HMI |
| Timing Resolution | 1 s, max duration 999 min |
| Thermocouple | K-type armored, Ø2 mm |
| Inlet Opening | 800 ± 20 (W) × 400 ± 10 (D) mm, located 150 ± 10 mm from front panel |
| Exhaust Duct | Stainless steel, integrated with optional gas analysis interface for HRR & SPR measurement |
| Brand | TESTech |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Direct Manufacturer |
| Model | TTech-UL2596 |
| Compliance Standard | UL 2596–2023 |
| Flame Temperature | Up to 1200 °C |
| Flame Power Output | 3 kW |
| Grit Feed Rate | 1.5 g/s ±10% |
| Test Cycle Modes | 15 s flame only |
| Control Interface | PC-based LabVIEW software + industrial touchscreen HMI |
| Gas Flow Control | Mass flow controllers for fuel gas and oxygen |
| Grit Air Flow Control | Mass flow controller |
| Frame Dimensions | 1200 mm × 500 mm × 1500 mm (W×D×H) |
| Burner Nozzle Diameter | 28.6 mm |
| Integrated Fireproof Baffle | Stainless steel + ceramic fiber, slide-in replaceable design |