Flue Gas and Particulate Sampler
Filter
Showing all 21 results
| Brand | Ailun General / Qingdao Ailun |
|---|---|
| Origin | Shandong, China |
| Model | AL-2051 |
| Sampling Flow Rate | 0.2–1.5 L/min |
| Flow Accuracy | ±0.1% (full scale) |
| Power Supply | AC 220 V ±10%, 50 Hz |
| Continuous Operation Time | >15 h |
| Operating Temperature | −20 to +45 °C |
| Operating Humidity | 0–95% RH |
| Dimensions | 240 × 180 × 240 mm |
| Weight | ~2 kg |
| Compliance | HJ/T 47–1999 |
| Brand | Ailun General / Qingdao Ailun |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | HB6020 |
| Instrument Type | Flue Gas and Particulate Sampler |
| Measured Gases | O₂, SO₂, NO, NO₂, CO, CO₂, H₂S |
| Flow Accuracy | ≤ ±4.0% |
| Maximum Cumulative Sampling Volume | 999,999.9 L |
| Flue Gas Velocity Range | 1–45 m/s |
| Moisture Content Range | 0–60% |
| Brand | Ailun General / Qingdao Ailun |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | HB6040 |
| Price Range | USD 14,000–42,000 (FOB) |
| Instrument Type | In-situ UV Absorption Flue Gas Analyzer |
| Measured Gases | SO₂, NO, NO₂, CO, CS₂, H₂S, NH₃ |
| Flow Accuracy | ≤ ±2 % FS |
| Sampling Flow Rate | 0.5–1.5 L/min |
| Flue Gas Velocity Range | 5–30 m/s |
| Moisture Content Measurement Range | 0.1–40.0 % v/v |
| Brand | AMAE |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | AC-3072C |
| Instrument Type | Flue Gas Sampler |
| Sampling Flow Rate | 200–2000 mL/min |
| Brand | AMAE |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | AC-5000A |
| Instrument Type | Flue Gas and Ambient Air VOC Sampler |
| Sampling Flow Rate | 10–200 mL/min |
| Brand | AMAE |
|---|---|
| Origin | Guangdong, China |
| Model | EM-3088-4.0 |
| Sampling Flow Rate | 0–110 L/min |
| Flow Accuracy | ±5% or better |
| Sample Type | Isokinetic particulate sampling + flue gas component analysis (O₂, SO₂, CO, NO, NO₂, H₂S, CO₂) |
| Compliance | Designed for fixed-source emission monitoring per Chinese EPA HJ/T 47–1999, HJ/T 48–1999, and compatible with ISO 16911-1:2013 principles |
| Power | Integrated rechargeable battery for field operation |
| Water Removal | Triple-stage condensate removal with auto-drain function |
| Data Output | Real-time parametric logging including stack temperature, static/dynamic pressure, atmospheric pressure, moisture content, flow velocity, and volumetric flow |
| Brand | AMAE |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | EM-3088S |
| Price Range | USD 16,500 – 20,500 |
| Instrument Type | Flue Gas and Particulate Sampler |
| Sample Application | Isokinetic particulate sampling and real-time flue gas component analysis in exhaust ducts under industrial operating conditions |
| Sampling Flow Rate | 0–110 L/min |
| Flow Accuracy | ±5% or better |
| Flue Gas Velocity Range (Isokinetic Suction) | 1–50 m/s |
| Moisture Tolerance | Relative Humidity ≤95% RH |
| Brand | AMS |
|---|---|
| Origin | Italy |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model | AMS Flue Gas Heavy Metal Sampler |
| Instrument Type | Particulate and Heavy Metal Sampling System |
| Target Analytes | Heavy Metals (e.g., Pb, Cd, Hg, As, Ni, Cr) |
| Flow Accuracy | ±2% |
| Compliance Standard | UNI-EN 14385 |
| Brand | AMS |
|---|---|
| Origin | Italy |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | AMS Flue Gas Particulate Sampling System |
| Instrument Type | Isokinetic Particulate Sampler |
| Flow Accuracy | ±2% |
| Brand | AMS |
|---|---|
| Origin | Italy |
| Model | AMS Dioxin |
| Instrument Type | Flue Gas Dioxin Sampling System |
| Flow Accuracy | ±2% |
| Compliance | UNI-EN 1948:2006 |
| Sampling Methods | Filter-Condensation, Dilution, Cooled Probe |
| Primary Adsorbent | XAD-2 Resin or PUF Foam |
| Heating Zone Temperature | <125 °C (maintained above gas dew point) |
| Condenser Outlet Temperature | <20 °C |
| Main Flow Rate | 3–5 m³/h |
| Side Stream Flow Rate | 0.5–0.7 m³/h |
| Side-to-Main Flow Ratio Tolerance | ±10% |
| Linear Velocity in XAD-2 Tube | ≤34 cm/s |
| Brand | AMS |
|---|---|
| Origin | Italy |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | AMS HCl Flue Gas Sampling System |
| Instrument Type | Flue Gas Sampling System |
| Flow Accuracy | ±2% |
| Compliance | EN 1911, ISO 9096:1992 |
| Operating Probe Temperature | ≥120 °C (≥20 °C above HCl acid dew point) |
| Filter Efficiency | >99.5% (glass fiber or quartz fiber) |
| Sample Transit Time | <5 s (nozzle to impinger) |
| Main Stream Flow Rate | 30–150 L/min (isokinetic mode) |
| Impinger Flow Rate | 2–3 L/min |
| Typical Sampling Volume | 50–200 L (for [HCl] = 1–10 mg/m³ |
| Brand | AMS |
|---|---|
| Origin | Italy |
| Model | AMS Mercury Sampling System |
| Instrument Type | Flue Gas Sampling System |
| Target Analyte | Mercury (Hg) and Other Heavy Metals |
| Flow Accuracy | ±2% |
| Compliance | UNI-EN 13211 |
| Sample Path Material | Borosilicate Glass & Inert Heated Components |
| Probe Operating Temperature | ≥120 °C (≥20 °C above acid dew point) |
| Max. Sample Residence Time | <5 s (from probe inlet to impinger train) |
| Brand | AMS |
|---|---|
| Origin | Italy |
| Model | Stack Gas2001 (600/ISS1400K) |
| Instrument Type | Heated Flue Gas Sampling Probe |
| Flow Accuracy | ±2% of full scale |
| Probe Length Options | 350 mm / 750 mm |
| Heating Element | Integrated, temperature-controlled |
| Filter | In-probe heated particulate filter (ceramic or sintered metal, typical operating temp: 180–200 °C) |
| Power Supply | Internal 14 Ah sealed lead-acid battery (rechargeable, designed for ≥500 cycles) |
| Sampling Line Assembly | Dual-layer polyethylene tubing (1.25 m length), integrated cooling jacket + electronic control unit (P/N 2100152) |
| Optional Integration | Compatible with DiluGas™ dynamic dilution system (dual-input interface) |
| Brand | BCT |
|---|---|
| Origin | Italy |
| Manufacturer Type | Manufacturer |
| Origin Category | Imported |
| Model | BCT QB-D |
| Instrument Type | Flue Gas Sampler |
| Sample Type | Flue Gas |
| Flow Accuracy | ±0.1% |
| Sampling Flow Rate | 5 mL/s |
| Flue Gas Velocity | 1 m/s |
| Moisture Content | 5% |
| Brand | BCT |
|---|---|
| Origin | Italy |
| Manufacturer Type | Manufacturer |
| Origin Category | Imported |
| Model | BCT SF PU |
| Instrument Type | Flue Gas and Particulate Sampler |
| Target Analytes | Heavy Metals, Polycyclic Aromatic Hydrocarbons (PAHs), Polychlorinated Dibenzo-p-dioxins and Dibenzofurans (PCDD/PCDF) |
| Flow Accuracy | ±1% |
| Sampling Flow Rate | 4.5–8.5 m³/h |
| Flue Gas Velocity Range | 100–500 L/min |
| Moisture Content Tolerance | 10% |
| Brand | BCT |
|---|---|
| Origin | Italy |
| Manufacturer Type | Manufacturer |
| Origin Category | Imported |
| Model | BCT SG5 |
| Instrument Type | Flue Gas and Particulate Sampler |
| Sample Type | Flue Gas |
| Flow Accuracy | ±2% |
| Sampling Flow Rate | 5–60 L/min |
| Flue Gas Velocity Range | 0.4–6.0 m³/h |
| Moisture Content Detection Limit | 0.1% |
| Brand | Guo Ruili Heng |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | OEM Manufacturer |
| Country of Origin | China |
| Model | GR-3100D-6 |
| Instrument Type | Flue Gas and Particulate Sampler |
| Sample Parameters | Dynamic Pressure, Static Pressure, Flow Velocity, Pre-Flowmeter Pressure, Pre-Flowmeter Temperature, Flue Gas Temperature, Moisture Content, O₂, SO₂, CO, NO, NO₂, H₂S, CO₂ |
| Flow Accuracy | ≤ ±5% |
| Sampling Flow Rate | 0–100 L/min |
| Flue Gas Velocity Range | 1–45 m/s |
| Moisture Content Range | 0–60% |
| Brand | Junray |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | ZR-3260E |
| Instrument Type | Flue Gas and Particulate Sampler |
| Measured Gases | SO₂, NO, NO₂, NOₓ, CO, CO₂, H₂S, O₂ |
| Sampling Flow Rate | Not specified |
| Flow Accuracy | Not specified |
| Flue Gas Velocity | Not specified |
| Moisture Content Measurement | Not specified |
| Brand | Loobo |
|---|---|
| Origin | Shandong, China |
| Model | LB-2 |
| Instrument Type | Flue Gas Sampler |
| Sample Medium | Flue Gas |
| Flow Accuracy | ±5% |
| Adjustable Sampling Flow Rate | 0.5–2.0 L/min |
| Pre-Flow Pressure Range | −30 to 0 kPa |
| Pre-Flow Temperature Range | −30 to +99 °C |
| Atmospheric Pressure Measurement Range | 70–130 kPa |
| Data Storage Capacity | 1000 sets |
| Operating Temperature | −30 to +50 °C |
| Dimensions (L×W×H) | 225 × 160 × 280 mm |
| Weight | ~3 kg |
| Power Supply | AC 220 V ±10%, 50 Hz or DC 12 V |
| Power Consumption | <20 W |
| Brand | Senbe |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Direct Manufacturer |
| Product Origin | Domestic (China) |
| Model | YQ3000-E |
| Instrument Type | Flue Gas Dioxin Sampler |
| Sample Medium | Flue Gas |
| Flow Accuracy | ±5% |
| Sampling Flow Rate | 1.5 L/min |
| Flue Gas Velocity Range | Up to 4 m/s |
| Moisture Content Tolerance | Up to 60% (v/v) |
| Brand | Tianhong |
|---|---|
| Origin | Hubei, China |
| Model | TH-220 |
| Display | 4.3-inch color touchscreen |
| Power Supply | 8.4 V rechargeable lithium battery |
| Data Storage | Up to 500 records |
| Output | Built-in thermal printer |
| Measurement Parameters | Dynamic pressure, static pressure, temperature, flue gas velocity, actual volumetric flow rate, dry standard volumetric flow rate |
| Compliance | Designed for field use in industrial stack testing per Chinese EPA guidelines (HJ/T 48–1999, HJ/T 397–2007) |
| Enclosure Rating | IP54 |