Food Safety Rapid Detectors
Filter
Showing 31–43 of 43 results
| Brand | Jiada Xiaotianshe |
|---|---|
| Origin | Jilin, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Category | Domestic (China) |
| Model | GDYQ-6000S |
| Function Type | Single-Analyte Quantitative Detection |
| Sample Versatility | Multi-Sample Compatible |
| Optical Detection Wavelength | 400 nm |
| Detection Channels | 1 |
| Lower Detection Limit | 10.0 mg/kg |
| Quantification Range | 0.0–1000.0 mg/kg |
| Measurement Accuracy | ±2% |
| Brand | Jiada Xiaotianshe |
|---|---|
| Origin | Jilin, China |
| Manufacturer Type | Direct Manufacturer |
| Region of Origin | Domestic (PRC) |
| Model | GDYQ-900M |
| Price Range | USD 7,000–14,000 (FOB) |
| Functionality | Multi-analyte (simultaneous detection of >20 food safety parameters) |
| Sample Versatility | Universal for solid, liquid, and semi-solid food matrices |
| Optical Detection Range | 495–530 nm |
| Repeatability | ≤ ±5% CV or ±5 RLUs |
| Detection Channels | 16 independent optical/analytical channels |
| Power Supply | AC/DC dual-mode |
| Display | 10.1" capacitive touchscreen, 1024 × 768 resolution |
| Data Storage | Internal SSD (≥64 GB) |
| Connectivity | Wi-Fi 802.11 b/g/n, Ethernet (RJ45), USB 2.0 × 2 |
| Output | Integrated thermal printer + external printer support via USB/Ethernet |
| Operating System | Windows Embedded Standard 7 |
| Software | Proprietary modular detection platform with remote OTA and local USB firmware update capability |
| Brand | Jiada Xiaotianshe |
|---|---|
| Origin | Jilin, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Category | Domestic (China) |
| Model | GDYQ-901SC2 |
| Function Type | Single-Analyte Detection |
| Sample Versatility | Multi-Sample Compatible |
| Optical Wavelength | 538 nm |
| Detection Channels | 1 |
| Detection Limit | 2.0 mg/kg |
| Measurement Range | 0.0–200.0 mg/kg |
| Accuracy | ±2% |
| Regulatory Method | Modified GB/T 5009.33–2003 |
| Brand | Jiada Xiaotianshe |
|---|---|
| Origin | Jilin, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | GDYQ-RS1101 |
| Function Type | Single-parameter Moisture Determination |
| Sample Scope | Multi-sample Universal (Fresh Mammalian & Poultry Muscle Tissue) |
| Measurement Range | 65–85% w/w |
| Sampling Time | <1 s per acquisition |
| Output Interval | One result per 10 acquisitions or per single acquisition (configurable) |
| Accuracy (70–80% range) | ±1.0% w/w |
| Repeatability (70–80% range) | ≤0.5% w/w |
| Operating Temperature | 0–40 °C |
| Power Alert | Yes |
| Auto-shutdown | Yes |
| Data Storage | Onboard memory with total count display and recall |
| PC Connectivity | USB interface for data export and post-processing |
| Brand | JiDa-Xiaotianshen |
|---|---|
| Origin | Jilin, China |
| Manufacturer Type | Manufacturer |
| Country of Origin | China |
| Model | GDYQ-100CX |
| Price Range | USD 0–1,450 (est.) |
| Function Type | Multi-analyte (simultaneous detection of multiple food contaminants) |
| Sample Compatibility | Universal for solid and liquid food/ agricultural samples |
| Brand | NCS |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | NX-300 |
| Function Type | Multi-analyte (Cd, Pb, As, Hg, Cr, etc.) |
| Sample Type Compatibility | Solid food matrices (rice, grains, flour, spices, infant formula, dried vegetables) |
| Detection Time | ≤3 min for screening |
| Power Supply | 220 VAC ±10%, 50/60 Hz, 1.5 A |
| Dimensions | 550 W × 330 D × 440 H mm |
| Weight | 30 kg |
| X-ray Source | Air-cooled microfocus X-ray tube |
| Detector | Fast Silicon Drift Detector (FastSDD) |
| Optical Path | Non-destructive, optimized beam collimation and scatter suppression architecture |
| Radiation Safety | Compliant with GBZ 115–2002 “Hygienic Protection Standard for X-ray Diffraction and Fluorescence Analyzers” |
| Brand | Shanda |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Authorized Distributor |
| Model | SD-HQMG |
| Price | USD 1,390 (FOB) |
| Function Type | Multi-analyte Detection Platform |
| Sample Scope | Universal for Cereals, Oilseeds, Feed Matrices, and Processed Food Commodities |
| Main Controller | ARM Cortex-A7 |
| Detection Channels | ≥12 independent optical channels |
| Display | 10.1-inch HD vertical capacitive touchscreen (1280×800) |
| Communication Interfaces | Integrated Wi-Fi (802.11 b/g/n), RJ45 Ethernet port, USB 2.0 host/device |
| Power Supply | DC 12 V — compatible with vehicle power outlets |
| Data Storage | Internal eMMC (16 GB) + USB flash drive support (FAT32/exFAT) |
| Dimensions (W×D×H) | 430 × 350 × 190 mm |
| Net Weight | 5.1 kg |
| Light Source | Precision imported quad-wavelength cold LED source (450 nm, 520 nm, 590 nm, 630 nm) |
| Processor | Rockchip RK3288 (ARM Cortex-A17 quad-core, 1.8 GHz) |
| Brand | Tianyan (Shandong Tianyan Instrument Co., Ltd.) |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | TY-GA1. |
| Function Type | Multi-parameter (simultaneous detection of up to 200 food safety analytes) |
| Sample Compatibility | Universal for liquid, extract, and homogenized solid food matrices |
| Detection Time | ≤3 minutes per batch |
| Detection Channels | 12 independent optical channels |
| Display | 10.1-inch vertical capacitive touch LCD (Android OS) |
| Main Controller | ARM Cortex-A7 + RK3288 quad-core CPU (1.88 GHz) |
| Light Source | Imported precision cold LED source with four fixed wavelengths (410 nm, 520 nm, 590 nm, 630 nm) |
| Optical Design | Precision rotating cuvette holder with inter-channel calibration uniformity ≤0.1% |
| Connectivity | Dual-band Wi-Fi (2.4/5 GHz), optional 4G LTE (APN-enabled), Bluetooth 4.2, dual USB 2.0 ports, RJ45 Ethernet |
| Power Supply | AC/DC dual-mode |
| Data Storage | Internal flash ≥16 GB + USB mass storage support |
| Dimensions (L×W×H) | 440 × 300 × 180 mm |
| Compliance | Designed to support ISO/IEC 17025 laboratory practices, aligned with GB 5009.x series, GB/T 5009.x, and SN/T standards for food testing |
| Brand | Tianyan |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | TY-SCG |
| Price Range | USD 830–1,810 (FOB) |
| Functionality | Multi-analyte Screening Platform |
| Sample Compatibility | Broad-spectrum aquatic and food matrices |
| Main Control IC | ARM Cortex-A7 |
| Detection Time | ≤ 3 minutes per test |
| Detection Channels | 12 independent lanes |
| Display | 10.1-inch capacitive touchscreen LCD |
| Detection Principle | Colloidal Gold Immunochromatographic Assay (CGIA) |
| Communication Interfaces | USB 2.0, Wi-Fi (802.11 b/g/n), RJ45 Ethernet |
| Power Supply | DC 12 V input (vehicle-compatible), integrated 6 Ah Li-ion battery |
| Data Storage | Internal flash + standard USB port for U-disk export |
| Dimensions (W×D×H) | 43 × 35 × 20 cm |
| Net Weight | 5.1 kg |
| Processor | Rockchip RK3288 (Quad-core ARM Cortex-A17, 1.8 GHz) |
| Brand | Yuntang |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | OEM Manufacturer |
| Country of Origin | China |
| Model | YT-QC4* |
| Price Range | USD 790–1,190 (FOB) |
| Function Type | Multi-analyte (Pesticide Residues, Mycotoxins, Antibiotics, Heavy Metals Screening) |
| Sample Versatility | Solid, Semi-solid, Liquid Food Matrices (Fruits, Vegetables, Meat, Aquatic Products, Dairy, Grains) |
| Wavelength Range | Not Applicable (Non-Optical Instrument) |
| Detection Time per Sample | 15 sec – 3 min (Preparation Only) |
| Throughput | 24 Parallel Processing Channels |
| Repeatability (RSD) | ≤0.1% (for standardized extraction recovery under GLP conditions) |
| Brand | Zhiyunda |
|---|---|
| Origin | Beijing, China |
| Model | ZYD-F |
| Function Type | Multi-analyte (Pesticide Residues, Veterinary Drug Residues e.g., Clenbuterol, Food Additives e.g., Nitrite, Heavy Metals via Optional Modules) |
| Sample Compatibility | Liquid, Extracted Homogenates, and Immunoassay Strips |
| Detection Limit | 0.01 mg/kg (for representative analytes e.g., organophosphates, nitrite) |
| Optical System | LED-based Photometric Detection at 410 nm, 520 nm, 590 nm, and 630 nm |
| Detection Time per Parameter | 3–10 min |
| Detection Channels | 12 Independent Optical Channels |
| Repeatability | ≤ ±3% CV |
| Display | ≥7-inch Color TFT Touchscreen |
| Detection Principles | Absorbance-based Spectrophotometry (for colorimetric assays) and Lateral Flow Immunoassay (LFIA) Interpretation |
| Microcontroller | High-Performance Embedded ARM Processor |
| Communication Interfaces | USB 2.0, Bluetooth 4.2, RS-232, Ethernet (Optional Wi-Fi Module) |
| Power Supply | AC 220 V ±10%, 50 Hz |
| Data Storage | Onboard Flash Memory (≥10,000 test records), Cloud Synchronization (via HTTPS API) |
| Dimensions | 380 mm × 280 mm × 150 mm |
| Net Weight | 3.5–4.8 kg |
| Light Source | Stable Cold LED Array |
| Environmental Operating Range | 10–35 °C, RH ≤80% (non-condensing) |
| Brand | Zhiyunda |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | ZYD-ZH |
| Function Type | Multi-analyte (Pesticide Residues, Veterinary Drug Residues, Heavy Metals, Microorganisms, Food Additives) |
| Sample Compatibility | Universal for Solid, Liquid, and Semi-solid Food Matrices |
| Detection Range | Pesticide residues (e.g., organophosphates, carbamates), veterinary drugs (e.g., chloramphenicol, sulfonamides), heavy metals (Pb, Cd, As, Hg via anodic stripping voltammetry), pathogenic microorganisms (via immunochromatographic lateral flow), food adulterants & illegal additives |
| LOD | 0.01 mg/kg for representative pesticide analytes |
| Optical System | LED cold light source |
| wavelength range | 380–800 nm |
| Detection Time | 3–10 min per assay |
| Detection Channels | 6 independent photometric channels (simultaneous multi-target quantification) |
| Repeatability | ≤ ±1% CV |
| Display | ≥7-inch capacitive touchscreen LCD |
| Detection Technologies | Integrated spectrophotometry, immunochromatography (lateral flow), thin-layer chromatography (TLC) imaging (254 nm UV excitation), fluorescence sensing, and anodic stripping voltammetry (ASV) |
| Connectivity | USB 2.0, Bluetooth 5.0, Wi-Fi 802.11 b/g/n, RJ45 Ethernet, microSD slot |
| Power Supply | Rechargeable Li-ion battery (≥8 h continuous operation) |
| Data Storage | Internal flash memory (≥100,000 records) + cloud synchronization (HTTPS-secured API endpoint) |
| Dimensions | 300 × 200 × 150 mm (L×W×H) |
| Net Weight | 2.3–2.8 kg |
| Enclosure Rating | IP67 (dust-tight and submersible up to 1 m for 30 min) |
| Processor | Quad-core ARM Cortex-A53 or higher |
| Image Acquisition | CMOS-based direct optical signal capture (no post-processing interpolation) |
| Brand | Zhiyunda |
|---|---|
| Origin | Beijing, China |
| Model | ZYD-ZH/02 |
| Function Type | Multi-analyte (pesticide residues, veterinary drug residues, food additives, heavy metals, mycotoxins, pathogenic microorganisms) |
| Sample Compatibility | Liquid, solid, and semi-solid food matrices (e.g., vegetables, fruits, meat, dairy, aquatic products, grains) |
| Detection Methods | Spectrophotometry (visible/NIR), immunochromatographic assay (colloidal gold lateral flow), ATP bioluminescence |
| Detection Time | 3–15 min per assay (pesticide screening) |
| Detection Channels | ≥8 independent optical channels with simultaneous dual-wavelength measurement capability |
| Repeatability | ≤±3% CV |
| Display | 15-inch capacitive touchscreen LCD (1920×1080) |
| Operating System | Android 9.0 (customized industrial firmware) |
| Data Storage | Internal 32 GB eMMC + microSD/TF slot (up to 256 GB) |
| Connectivity | Gigabit Ethernet, Wi-Fi 5 (802.11ac), Bluetooth 5.0, 4G LTE (optional module) |
| Power Supply | AC 220 V ±10%, 50 Hz / DC 12.6 V (rechargeable Li-ion battery, ≥4 h continuous operation) |
| Dimensions (L×W×H) | 380 × 320 × 180 mm |
| Net Weight | 7.2 kg |
| Light Source | Stable cold LED array with wavelength-specific emission profiles (450–650 nm, configurable per assay) |
| Processor | Quad-core ARM Cortex-A72 @ 1.8 GHz + dedicated DSP co-processor for real-time spectral deconvolution and signal normalization |
| Regulatory Alignment | Designed to support compliance with GB/T 5009.x, GB 2763, GB 31650, NY/T 761, SN/T 1944, and ISO/IEC 17025 documentation requirements |