| [Brand | AMETEK Chatillon |
|---|---|
| Origin | USA |
| Model | DFS2-R-ND |
| Accuracy | ±0.25% of full scale |
| Display | High-resolution LCD, backlit |
| Measurement Modes | Real-time, Peak Hold, Pass/Fail, Statistical Averaging, Load Comparison, Break Detection |
| Units | lbf, ozf, gf, kgf, N (force) |
| Interface | RS-232 |
| Compliance | NIST-traceable calibration certificate available |
| Software | Optional NEXYGEN DF Suite |
| Sensor Compatibility | SLC series load cells (tension/compression), STS series torque sensors |
| Auto-sensing | Automatic transducer identification] |
| Brand | Chatillon |
|---|---|
| Origin | USA |
| Model | DFS 3 |
| Force Range | 0.5–500 lbf (2.5–2500 N) |
| Accuracy | ±0.1% of full scale |
| Sampling Rate | Up to 30 kHz |
| Display | Full-color LCD with adjustable brightness and invertible orientation |
| Units | ozf, gf, lbf, kgf, N |
| Interface | USB, RS-232 |
| Software | ForceTest 3.0 (included) |
| Compliance | CE, RoHS |
| Enclosure Rating | IP65-rated front panel |
| Password Protection | Yes (menu lock, setup lock, result masking) |
| Built-in Statistics | Min/Max/Avg/Peak/SD/CPK |
| Audible Feedback | Configurable key tone & alarm |
| Environmental Rating | Operating temp. 0–40 °C, humidity ≤80% RH non-condensing |
| Brand | Chatillon |
|---|---|
| Origin | USA |
| Model | DFX II |
| Accuracy | ±0.3% of full scale |
| Display | Dot-matrix LCD |
| Battery Life | 70–100 hours (continuous use) |
| Force Ranges | 10 lbf, 50 lbf, 100 lbf, 200 lbf |
| Units | ozf, gf, lbf, kgf, N |
| Interface | Built-in calibration routine |
| Language Selection | Yes |
| Compliance | ASTM E4, ISO 7500-1 (Class 1), GLP-compliant data logging capability |
| Brand | Chatillon |
|---|---|
| Origin | USA |
| Model Series | DFX010, DFX050, DFX100, DFFX200 |
| Capacity Range | 10 lbf, 50 lbf, 100 lbf, 200 lbf |
| Accuracy | ±0.5% of full scale |
| Power Supply | Two 9V alkaline batteries (120 h typical life) or universal AC adapter (US/UK/EU plug variants) |
| Display | High-resolution backlit LCD |
| Units | ozf, gf, lbf, kgf, N |
| Language Support | English, Spanish, French, German, Portuguese, Chinese |
| Compliance | NIST-traceable calibration certificate available (optional) |
| Brand | Chatillon |
|---|---|
| Origin | Denmark |
| Model | DFX3 |
| Capacity Options | 10 lbf / 50 lbf / 100 lbf / 200 lbf |
| Units | ozf, gf, lbf, kgf, N |
| Battery Life | Up to 40 hours |
| Data Storage | 100 timestamped readings |
| Overload Protection | 150% of full scale |
| Calibration | NIST-traceable |
| Interface | USB-C |
| Display | Full-color LCD with real-time load bar and peak hold |
| Brand | Digerui |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | DKR |
| Price | USD 140 (approx.) |
| Key Standards | GB 15811-2016, YY/T 0167, ISO 7864, ASTM F2182 |
| Nominal Needle Gauge Range | 0.2–3.4 mm |
| Force Measurement Range | 0–20 N (standard), 0–50 N (optional) |
| Force Accuracy | ±0.5% FS |
| Crosshead Speed Range | 0–500 mm/min |
| Speed Accuracy | Class 0.5 |
| Penetration Substrate | Medical-grade polyurethane membrane per GB 15811 |
| Display | 7-inch industrial capacitive touchscreen |
| Data Output | Built-in thermal printer |
| Software | Multi-level user permission management, remote firmware update capability |
| Compliance | Designed for GLP-aligned lab environments |
| Brand | Digerui |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Model | DKR-HCOF- |
| Force Range | 10 N (standard) |
| Accuracy | Better than Class 0.5 |
| Force Resolution | 0.01 N |
| Displacement Accuracy | Class 0.5 |
| Displacement Resolution | 0.1 mm |
| Test Speed | 1–800 mm/min (infinitely variable) |
| Stroke | 1000 mm |
| COF Test Distance | >150 mm |
| Catheter Clamp Gap | 0–50 mm |
| Water Bath Temperature Control Range | Ambient to 40 °C |
| Sample Capacity | 1 catheter per test |
| Power Supply | AC 220 V, 50 Hz |
| Dimensions (L×W×H) | 540 × 450 × 1560 mm |
| Net Weight | 92 kg |
| Brand | Dillon |
|---|---|
| Origin | United Kingdom |
| Model | AWT05-506447 |
| Construction | Industrial-grade RF module with IP65-rated housing |
| Operating Range | Up to 300 ft (91 m) line-of-sight |
| Battery Life | ≥12 months (CR2032 lithium coin cell) |
| Compatibility | All Dillon EDXTREME series digital force gauges (EDx–1T through EDx–250T) |
| Protocol | Proprietary 2.4 GHz FHSS (Frequency-Hopping Spread Spectrum) |
| Certifications | CE, UKCA, FCC Part 15 Subpart C |
| Brand | Lasertec |
|---|---|
| Origin | Japan |
| Model | ZTS-DPU |
| Accuracy | ±0.2% F.S. ±1 digit |
| Sampling Rate | Up to 2000 Hz |
| Display | 4-digit OLED (color, high-brightness) |
| Operating Temperature | 0–40 °C |
| Humidity Range | 20–80% RH |
| Overload Protection | 200% F.S. (audible/visual alarm at >110% F.S.) |
| Battery Life | 8 h (2 h recharge) |
| Output Interfaces | USB, RS-232C, Mitutoyo-compatible digital output, 2 VDC analog output, comparator outputs (3-step: –NG/OK/+NG), auxiliary I/O for displacement sensing |
| Data Storage | Internal 1000-point memory + optional USB flash drive (up to 100 data points/sec) |
| Units | N, kgf, lbf (auto-scaled per range) |
| Weight (indicator only) | ~490 g |
| Compliance | CE-marked |