Freeze Dryer
Filter
Showing all 17 results
| Brand | DELEITE |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | VFD-12 |
| Application Scope | Research & Development Laboratories |
| Ultimate Vacuum Pressure | ≤5 Pa |
| Condenser Capacity (24 h) | 3–4 kg/batch |
| Condenser Temperature (No-Load) | ≤−65 °C |
| Pumping Speed | 2 L/s |
| Shelf/Flask Configuration | T-Style Manifold with 8 or 12 Ports |
| Flask Compatibility | Four 250 mL + Four 500 mL Standard-Neck Round-Bottom Flasks (19/22 or 24/29 joint) |
| Cooling Method | Air-Cooled |
| Power Consumption | 950 W |
| Dimensions (W×D×H) | 580 × 500 × 730 mm (main unit) + 430 mm (manifold height) |
| Ambient Operating Temperature | ≤25 °C |
| Electrical Supply | 220 V, 50 Hz |
| Material | AISI 304 Stainless Steel Condenser Chamber & Valves |
| Control Interface | 7-inch Full-Color TFT Touchscreen (Bilingual: English/Chinese) |
| Data Storage | Internal Flash Memory + USB Export (Excel .xlsx format) |
| Compliance | Designed to support GLP-compliant workflows |
| Brand | EYELA |
|---|---|
| Origin | Japan |
| Model | FDL-1000 / FDL-2000 |
| Cold Trap Temperature | −45 °C (FDL-1000) / −80 °C (FDL-2000) |
| Ice Capacity | 4 L/24 h (FDL-1000) / 3 L/24 h (FDL-2000) |
| Cold Trap Dimensions | Ø200 × 300 mm, SUS304 |
| Vacuum Gauge | Pirani gauge, 0.0–533 Pa (digital display) |
| Refrigeration System | FDL-1000 — 600 W, R404A |
| Vacuum Pump Interface | Optional, 100/120 L/min (50/60 Hz) |
| Display | 3.4-inch TFT LCD with membrane keypad |
| Power Supply | Dedicated socket for freeze-drying chamber (max. 3 A) |
| External Dimensions (W×D×H) | 700 × 550 × 955 mm |
| Net Weight | ~116 kg (FDL-1000) / ~144 kg (FDL-2000) |
| Safety Features | Leakage current protection, overcurrent protection, compressor protection circuit, service outlet fuse, self-diagnostic control panel, automatic venting upon vacuum release |
| Optional Accessories | Ice mass sensor, data logging output (analog), 0.2 µm inlet filter, defrost function, power recovery timer |
| Brand | EYELA |
|---|---|
| Origin | Japan |
| Model | FDM-1000 |
| Cold Trap Temperature | −45 °C |
| Condensation Capacity | 1 L/24 h |
| Display | 3.4″ LCD (button-operated) |
| Vacuum Gauge | Digital Pirani gauge (0.0–533 Pa) |
| Cold Trap Dimensions | Ø200 × 175 H mm (SUS304) |
| Refrigeration System | Air-cooled compressor (450 W, R507A) |
| Vacuum Pump Interface | Dedicated socket (max. 6 A), compatible with ≥50 L/min pumps |
| Power Supply | 7 A total (230 V AC, 50/60 Hz) |
| External Dimensions & Weight | 450 W × 420 D × 460 H mm / ≈38 kg |
| Safety Features | Leakage and overcurrent protection, compressor protection circuit, panel self-diagnostic function, vacuum release valve (0.2 µm filter), hot-gas defrost, power-fail recovery logic |
| Optional Functions | Vacuum pump auto-start/stop, real-time vacuum & cold trap temperature monitoring, elapsed time counter (vacuum pump runtime), automatic end-of-drying detection, vacuum auto-bleed post-cycle |
| Brand | EYELA |
|---|---|
| Origin | Japan |
| Model | FDM-2010 |
| Cold Trap Temperature | −80 °C |
| Condensation Capacity | 1 L/24 h |
| Display | 3.4-inch LCD |
| Vacuum Gauge | Digital Pirani gauge (0.0–533 Pa) |
| Cold Trap Dimensions | Ø153 × 225 H mm, SUS304 |
| Refrigeration System | Dual 500 W compressors, HFC blend (R290/R170) |
| Vacuum Pump Interface | Dedicated 125 V/6 A outlet (pump not included |
| Freeze Drying Chamber Interface | Dedicated 125 V/2 A outlet |
| Overall Dimensions | 450 W × 550 D × 945 H mm |
| Net Weight | ~81 kg |
| Safety | Leakage current protection, overcurrent cutoff, compressor thermal protection, self-diagnostic control panel, vacuum release valve with 0.2 µm particulate filter, hot-gas defrost system |
| Functions | Auto-vacuum start/stop, vacuum & cold trap temperature monitoring, elapsed time logging (for pump runtime and sublimation duration), power-failure recovery, automatic vacuum break post-cycle |
| Brand | EYELA (Tokyo Rikakikai Co., Ltd.) |
|---|---|
| Origin | Japan |
| Model | FDU-2110 |
| Cold Trap Temperature | −80 °C |
| Condensation Capacity | 3 L per 24 h |
| Vacuum Range | 0.4–533 Pa (Pirani gauge, digital display) |
| Cold Trap Dimensions | Φ200 × 300 mm (SUS304 stainless steel) |
| Refrigeration System | 500 W dual-stage compressor, R404A/R23 refrigerant blend |
| Defrost Method | Hot-gas auto-defrost with thermal cutoff |
| Vacuum Release | Motorized solenoid valve with 0.2 µm sterile air filter |
| Power Supply | Vacuum pump circuit — max. 6 A |
| Overall Dimensions & Weight | 700 × 550 × 935 mm (W×D×H), approx. 140 kg |
| Safety Features | Leakage/overcurrent protection, compressor protection circuit, control panel self-diagnosis, fuse for service outlet |
| Brand | Millrock |
|---|---|
| Origin | USA |
| Model | EPIC 85 |
| Shelf Area | 1.394–2.787 m² |
| Condenser Capacity | 50 L |
| Condenser Temperature | –85 °C |
| Shelf Temperature Range | –70 to +65 °C |
| Chamber Material | 316L Stainless Steel |
| Vacuum Sensor | Standard Pirani Gauge |
| Condenser Type | Coil-Type with Hot-Gas Defrost |
| Control System | PC/PLC-Based with Ethernet Connectivity |
| Optional | ISO Class 5 Cleanroom Configuration, H₂O₂ Sterilization Port, Isolation Interface |
| Brand | Scientz |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Manifold Benchtop Freeze Dryer |
| Application Scale | Pilot-Scale |
| Freeze-Drying Area | 0.12 m² |
| Ultimate Vacuum | ≤5 Pa |
| Condensate Capacity (24 h) | 4 kg/batch |
| Cold Trap Temperature | ≤−56 °C |
| Dimensions (L×W×H) | 600 × 450 × 720 mm + 440 mm (condenser height) |
| Brand | Scientz |
|---|---|
| Origin | Zhejiang, China |
| Model | Scientz-25T |
| Instrument Type | Standard Shelf-Type Freeze Dryer |
| Application | Laboratory-Scale Lyophilization |
| Freeze-Drying Area | 2.5 m² |
| Ultimate Vacuum | ≤10 Pa |
| Condensate Capacity (24 h) | 15 kg/24 h |
| Cold Trap Temperature | ≤ −85 °C |
| Dimensions (W×D×H) | 2300 × 1200 × 2200 mm |
| Control System | PLC + Touchscreen HMI |
| Data Compliance | FDA 21 CFR Part 11–Ready Audit Trail & Exportable Log Files |
| Refrigeration Technology | Single-Unit Self-Contained Cascade Refrigeration System |
| Valve Actuation | Individual Silicone Rubber Stopper Valves per Flask |
| Optional Accessories | Customizable Flask Racks, Glass Vials, Vacuum Inlet Nozzles, Nitrogen Backfill Valve |
| Brand | Scientz |
|---|---|
| Origin | Zhejiang, China |
| Model | SCIENTZ-10N/A |
| Instrument Type | Standard Shelf-Type Freeze Dryer |
| Application Scope | Laboratory Use |
| Lyophilization Area | 0.12 m² |
| Ultimate Vacuum (Empty Chamber) | ≤5 Pa |
| Main Unit Dimensions | 610(L) × 482(W) × 455(H) mm + 440 mm (Cold Trap Height) |
| Condenser Capacity | 3 kg/batch |
| Empty-Chamber Condenser Temperature | ≤−56 °C (standard) |
| Power Supply | 220 V, 50 Hz |
| Rated Power | 0.95 kW (standard) |
| Ambient Operating Temperature | ≤25 °C |
| Net Weight | 55 kg (standard) |
| Brand | Scientz |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | OEM Manufacturer |
| Instrument Type | Hydraulic Stoppering Freeze Dryer |
| Application Scope | Pilot-Scale Processing |
| Lyophilization Area | 0.54 m² |
| Ultimate Vacuum (No Load) | ≤5 Pa |
| Ice Capacity (24 h) | 10 kg/24 h |
| Cold Trap Temperature (No Load) | ≤−70 °C |
| Main Unit Dimensions (L×W×H) | 1320 × 850 × 1550 mm |
| Brand | Millrock |
|---|---|
| Origin | USA |
| Model | STELLAR 53/85 |
| Shelf Area | 0.348–0.58 m² |
| Shelf Spacing | 63 mm |
| Condenser Capacity | 12 L |
| Condenser Temperature | −53 °C or −85 °C |
| Shelf Temperature Range | −45 °C / −70 °C to +65 °C |
| Chamber Material | 316L Stainless Steel |
| Vacuum Pump Flow Rate | 200 L/min |
| Vacuum Sensor | Pirani Gauge |
| Condenser Type | Coil-Type with Hot-Gas Defrost |
| Optional Features | ISO Class 5 Cleanroom Configuration, H₂O₂ Sterilization Port, Isolation Interface |
| Brand | SONGYUAN HUAXING |
|---|---|
| Origin | Shanghai, China |
| Model | SYFD-18T-24 |
| Cold Trap Temperature | ≤ −85 °C (optional −110 °C) |
| Manifold Type | T-shaped stainless steel manifold with 3-way valves per port |
| Control Interface | 7-inch industrial touch screen with real-time lyophilization curve display and data logging |
| Defrost System | Low-voltage electric cold trap defrost |
| Gas Inlet | Integrated nitrogen (or inert gas) purge valve |
| Data Export | USB flash drive interface |
| Vacuum Pump | Dedicated oil-free or dry scroll vacuum pump (model-specific) |
| Compliance | Designed to meet FDA 21 CFR Part 11 data integrity requirements and current GMP (Annex 1 & ICH Q5C) operational standards |
| Brand | TAITEC |
|---|---|
| Origin | Japan |
| Model | VA-140S |
| Instrument Type | Benchtop Cryo-Cold Trap |
| Application | Laboratory-Scale Condensation & Solvent Capture |
| Cooling Temperature | –65 °C (at no load, 20 °C ambient, 500 mL methanol) |
| Operating Temperature Range | –10 °C to –55 °C (temperature control accuracy ±2.0 °C) |
| Condensate Capacity | ~300 mL per cycle (with GC-025 glass condenser) |
| Cooling Bath Volume | ~960 mL (Φ120 × 80 mm) |
| Stirring Function | Integrated magnetic stirrer |
| Refrigeration System | 40 W Stirling-cycle helium cooler (zero ODP, zero GWP) |
| Power Supply | AC 100 V, 1 A (up to 7 A with auxiliary socket) |
| Dimensions | 233 × 330 × 392 mm (W × D × H) |
| Weight | ~10 kg |
| Brand | Tianfeng |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | SFD-5E Biopharmaceutical Freeze Dryer |
| Instrument Type | Standard Shelf-Type |
| Application Scope | Production-Scale |
| Lyophilization Area | 3 m² |
| Ultimate Vacuum | ≤10 Pa |
| Condensate Capacity (24h) | 30 kg/24h |
| Condenser Temperature | ≤−75 °C |
| Overall Dimensions (L×W×H) | 4600 × 2000 × 2850 mm |
| Maximum Ice Capacity | 100 kg |
| Shelf Count | 5 + 1 Radiant Compensation Shelf |
| Shelf Dimensions | 1200 × 900 × 20 mm |
| Total Usable Shelf Area | 5.4 m² |
| Shelf Spacing | 100 mm |
| Temperature Range | −55 °C to +80 °C |
| Control System | Omron PLC with TF-5000 Software & 10.4″ Omron HMI |
| Power Supply | 35 kW, 380 V / 50 Hz / 3-Phase / 5-Wire |
| Cooling Water Requirement | 15 m³/hr (1.5–2 bar, ≤25 °C) |
| Compressed Air Requirement | 60 L/min (6–8 bar) |
| Sterile Chamber Option | Hydraulic Shelf Lift System |
| Compliance | cGMP, ISO 9001, 21 CFR Part 11 Ready (Audit Trail & Electronic Signatures Enabled) |
| Brand | Tianfeng |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | OEM Manufacturer |
| Model | TF-FD-1 (Standard Shelf Type) |
| Freeze-Drying Area | 0.12 m² |
| Ultimate Vacuum | <15 Pa (no-load) |
| Condenser Temperature | <−50 °C |
| Ice Capacity | 3 kg/24 h |
| Power Consumption | 1100 W |
| Dimensions (W×D×H) | 370 × 650 × 360 mm |
| Chamber Material | 304 Stainless Steel |
| Viewing Window | Transparent Acrylic Door |
| Control System | Touchscreen LCD with PID Regulation |
| Refrigeration | Air-Cooled Single-Stage System |
| Sample Tray | Φ200 mm × 4 Layers |
| Electrical Supply | 220 V, 50 Hz |
| Brand | Tianfeng |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Shelf-Type Freeze Dryer |
| Application Scope | Pilot-Scale Processing |
| Lyophilization Area | 1.04 m² |
| Ultimate Vacuum | ≤5 Pa |
| Condenser Temperature | ≤−75 °C |
| Ice Capacity (24 h) | 16 kg/24 h |
| Condenser Cooling Rate (20 °C → −40 °C) | ≤15 min |
| Shelf Temperature Range | −50 °C to +80 °C |
| Shelf Cooling Rate (20 °C → −40 °C, empty) | ≤60 min |
| Shelf Heating Rate (−40 °C → +20 °C, empty) | ≤60 min |
| Pump-Down Time (Atm → 10 Pa, empty) | ≤15 min |
| Dimensions (W×D×H) | 1250 × 1100 × 1800 mm |
| Weight | ~700 kg |
| Power Supply | 3-phase 380 VAC, 50 Hz |
| Installed Power | 8 kW |
| Typical Operating Power | <7.5 kW |
| Ambient Operating Temperature | 5–25 °C |
| Compliance | ISO 9001:2000 certified design and manufacturing |
| Brand | Ying’an Meicheng |
|---|---|
| Origin | United Kingdom |
| Model | LSM55P |
| Instrument Type | Standard Shelf-Type Freeze Dryer |
| Application Scope | Pilot-Scale Laboratory Use |
| Ultimate Vacuum | <20 Pa |
| Condenser Temperature | −55 °C |
| Condenser Capacity | 44.5 L |
| Main Unit Dimensions | 945 × 700 × 950 mm |
| Construction Material | Stainless Steel (SS304) |
| Control Interface | Touchscreen HMI |
| Defrost Method | Hot-Gas Defrost |
| Data Storage | Internal Memory + USB Export |
| Mobility | Integrated Casters |