Gas Alarms
Filter
Showing 1–30 of 55 results
| Brand | Apogee |
|---|---|
| Origin | USA |
| Model | SO-100 |
| Output | 0–50 mV (SO-100), 0–12 mV (SO-200) |
| Measurement Range | 0–100% O₂ |
| Accuracy | <0.02% drift/day |
| Repeatability | ±0.001% O₂ (10 ppm) |
| Response Time | 60 s (SO-100), 12 s (SO-200) |
| Operating Temperature | –20 to +60 °C |
| Relative Humidity | 0–100% RH |
| Pressure Range | 60–140 kPa |
| Power Supply | 12 V for heater |
| Sensor Housing | Polypropylene valve body |
| Cable Length | 2 m |
| Weight | 210 g |
| Lifetime | >10 years (SO-100), >5 years (SO-200) |
| Interference | None from CO₂, CO, NO, NO₂, H₂S, H₂, CH₄ |
| Brand | Axetris |
|---|---|
| Origin | Switzerland |
| Model | EMIRS200, EMIRS50 |
| Housing | TO-39 metal can |
| Emitter Type | MEMS micro-hotplate with dielectric thin-film coating |
| Spectral Range | 2–16 µm (blackbody-like emission) |
| Modulation Capability | Direct electrical square-wave modulation (chopper-free) |
| Typical Power Consumption | <150 mW (EMIRS200), <300 mW (EMIRS50) |
| Radiant Efficiency | >30% (relative to ideal blackbody at same temperature) |
| Lifetime | >100,000 hours (at nominal drive conditions) |
| Environmental Certification | IEC 60747-17 / IEC 62047-21 compliant |
| Window Options | Sapphire (Al₂O₃), CaF₂, BaF₂, Ge |
| Mounting | Standard TO-39 header with optional reflective cup or protective cap |
| Brand | Baseline |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | BASELINE piD-TECH eVx |
| Pricing | Available Upon Request |
| Brand | Baseline |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | eV-NXT 045-110 |
| Price | Upon Request |
| Detection Range | 0–10,000 ppm |
| LOD | 500 ppb |
| T90 Response Time | < 3.5 s |
| Typical Sensitivity | 0.6 mV/ppm |
| Calibration Gas | 2000 ppm Isobutylene (standard) |
| Operating Temperature | –20 °C to +50 °C |
| Operating Humidity | 0–95% RH (non-condensing) |
| Power Supply | 3.3 V DC nominal |
| Power Consumption | < 80 mW (active mode) |
| Brand | Baseline |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Import Status | Imported |
| Model | eV-NXT 045-111 |
| Detection Range | 0–2,000 ppm |
| LOD | 100 ppb |
| T90 Response Time | < 3.5 s |
| Typical Sensitivity | 2.4 mV/ppm |
| Measurement Condition | 100 ppm |
| Operating Voltage | Low-Voltage DC |
| Power Consumption | Ultra-Low |
| Intrinsic Safety Rating | Certified |
| Onboard Fault Detection | Yes |
| Brand | Baseline |
|---|---|
| Origin | USA |
| Model | eV-NXT 045-112 |
| Detection Range | 0–200 ppm |
| LOD | 10 ppb |
| T90 | < 3.5 s |
| Typical Sensitivity | 12 mV/ppm |
| Operating Condition | 100 ppm |
| Power Requirements | Low-voltage, low-power design |
| Compliance | Intrinsically Safe (IS) certified |
| Brand | Baseline |
|---|---|
| Origin | USA |
| Model | eV-NXT 045-113 |
| Detection Range | 0–20 ppm |
| LOD | 1.0 ppb |
| T90 | < 6.5 s |
| Typical Sensitivity | 118 mV/ppm |
| Measurement Condition | 10 ppm |
| Operating Voltage | Low-Voltage DC |
| Brand | Baseline |
|---|---|
| Origin | USA |
| Model | eV-NXT 045-114 |
| Detection Range | 4 ppm |
| LOD | 0.5 ppb |
| T90 | < 6.5 s |
| Typical Sensitivity | 545 mV/ppm |
| Measurement Condition | 1 ppm |
| Brand | Baseline |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | BASELINE PID-TECH eV-NXT |
| Pricing | Available Upon Request |
| Brand | Baseline |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | piD-TECH® eVx™ 045-010 |
| Pricing | Available Upon Request |
| Certification | UL, CAN/CSA C22.2 No. 60079-0, ATEX II 2G Ex d [ia] IIC T4 Ga, IECEx Ex d [ia] IIC T4 Ga |
| Detection Range | 0–10,000 ppm isobutylene equivalent |
| Minimum Detectable Quantity (MDQ) | 500 ppb (isobutylene) |
| T90 Response Time | < 2 s (typical) |
| Lamp Lifetime | > 12,000 hours |
| Operating Temperature | –20 °C to +50 °C |
| Humidity Range | 0–95% RH (non-condensing) |
| Output Signal | 0–5 V DC analog |
| Power Supply | 5.0 V ±0.1 V DC |
| Ingress Protection | IP67-rated housing |
| Filter Configuration | Dual-stage particulate & hydrophobic membrane filter |
| Temperature Drift | < 0.05% FS/°C |
| Humidity Compensation | Electrode-based active suppression |
| Brand | Baseline |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | piD-TECH® eVx™ 045-011 |
| Price | Upon Request |
| Detection Range | 2,000 ppm |
| Minimum Detectable Quantity (MDQ) | 100 ppb |
| T90 Response Time | < 2 s (typical) |
| Certification | UL, CAN/CSA, ATEX, IECEx |
| Design | Intrinsically Safe, 4-Series Compatible Form Factor |
| Lamp Lifetime | Extended Operational Life |
| Temperature Sensitivity | Negligible |
| Humidity Compensation | Electrode-Based Suppression |
| Filtering | Dual-Stage Particle Protection |
| Signal Stability | Internal Linear Regulator Circuitry |
| Maintenance | Field-Serviceable, Cleanable Electrodes |
| Brand | Baseline |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | piD-TECH® eVx™ 045-013 |
| Price | Upon Request |
| Detection Range | 20 ppm |
| Minimum Detectable Quantity (MDQ) | 1.5 ppb |
| T90 Response Time | < 4 s (typical) |
| Housing Color | Yellow |
| Certification | UL, CAN/CSA, ATEX, IECEx |
| Sensor Architecture | 4-Series Compatible |
| Lamp Type | Long-Life UV Lamp (10.6 eV) |
| Internal Regulation | Dual Linear Voltage Regulators |
| Filtration | Dual-Stage Particle Filter |
| Humidity Compensation | Electrode-Based Suppression |
| Thermal Drift | Negligible |
| Maintenance | Field-Serviceable & Cleanable |
| Brand | Baseline |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | piD-TECH® eVx™ 045-014 |
| Pricing | Available Upon Request |
| Detection Range | 2 ppm |
| Minimum Detectable Quantity (MDQ) | 0.5 ppb |
| T90 Response Time | < 4 s (typical) |
| Certification | UL, CAN/CSA C/US, ATEX II 1G, IECEx Ex ia IIC T4 Ga |
| Sensor Architecture | 4-Series Compatible Form Factor |
| Lamp Life | > 12,000 hours |
| Operating Temperature Range | –20 °C to +50 °C |
| Humidity Compensation | Electrode-based suppression |
| Filtering | Dual-stage particulate protection |
| Power Supply | Internal linear regulation for signal stability |
| Maintenance | Field-serviceable, cleanable electrode assembly |
| Brand | Baseline |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | piD-TECH® eVx™ |
| Detection Range | 0–2,000 ppm |
| Minimum Detectable Quantity (MDQ) | 10 ppb |
| T90 Response Time | < 2 s (typical) |
| Certifications | UL, CAN/CSA C22.2 No. 152, ATEX II 2G Ex ia IIC T4 Ga, IECEx Ex ia IIC T4 Ga |
| Intrinsic Safety Design | Yes |
| Lamp Lifetime | > 12,000 hours |
| Operating Temperature | –20 °C to +50 °C |
| Humidity Compensation | Electrode-based humidity suppression |
| Dual-Stage Particle Filtration | Integrated |
| Signal Stability | Internal linear voltage regulation |
| Structural Compatibility | 4-Series electrochemical sensor footprint |
| Brand | Cubic |
|---|---|
| Origin | Hubei, China |
| Model | AIS-3200 |
| Detection Gases | PM2.5 (0–1000 µg/m³), CO₂ (400–10,000 ppm) |
| PM2.5 Principle | Laser Scattering |
| CO₂ Principle | Single-Source NDIR with Dual-Channel Detection |
| PM2.5 Accuracy | ±15% of reading or ±15 µg/m³ (−20°C to +75°C, referenced to TSI 8530) |
| CO₂ Accuracy | ±100 ppm or ±10% (400–10,000 ppm, −20°C to +75°C) |
| PM2.5 Response Time (T90) | ≤12 s |
| CO₂ Response Time (T90) | ≤25 s |
| Warm-up Time | <10 s |
| Operating Temperature | PM2.5: −40°C to +75°C |
| CO₂ | −40°C to +85°C |
| Storage Temperature | −40°C to +95°C |
| IP Rating | IP65 |
| Dimensions | Compact, automotive-grade form factor |
| Brand | Cubic |
|---|---|
| Origin | Hubei, China |
| Manufacturer Type | Authorized Distributor |
| Region of Manufacture | Domestic (China) |
| Model | AM1012 |
| Price | USD 72 (FOB) |
| Detection Parameters | PM2.5 (0–1000 µg/m³), CO₂ (400–2000 ppm), Temperature (−10°C to 50°C), Relative Humidity |
| Refresh Rate | 1 s |
| Power Supply | DC 12 V ±1 V |
| Current Consumption | <500 mA |
| Communication Interface | RS485 |
| Dimensions | 81.3 × 74.3 × 25.9 mm |
| EMC Performance | Built-in voltage regulation, ESD protection (>±8 kV contact discharge), conducted/radiated immunity compliant with IEC 61000-4 series |
| Operating Humidity Range | 0–95% RH non-condensing |
| Brand | Cubic |
|---|---|
| Origin | Hubei, China |
| Model | AM4205 |
| Detection Principle | Non-Dispersive Infrared (NDIR) |
| Detection Range | 0–50% LFL |
| Resolution | 1% LFL |
| Accuracy | ±3.75% LFL |
| Data Refresh Rate | ≤1 s |
| Response Time (T90) | <30 s |
| Warm-up Time (T25) | ≤7 s |
| Output Options | UART / 0.8–4 V (default) / PWM (customizable) |
| Operating Temperature | −30 to +60 °C |
| Operating Humidity | 0–95% RH (non-condensing) |
| Storage Conditions | −30 to +70 °C / 0–95% RH (non-condensing) |
| Supply Voltage | 5 ± 0.1 V DC (ripple <50 mV) |
| Average Current Consumption | ≤150 mA |
| Peak Current | <300 mA |
| IP Rating | IP54 |
| Heating Function | Integrated self-heating element for anti-condensation and frost prevention |
| Brand | Cubic |
|---|---|
| Origin | Hubei, China |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | APMS-5000 |
| Price | Upon Request |
| Detection Principle | Laser Light Scattering |
| Measurement Range | 0–1000 µg/m³ |
| Accuracy | ±10% (100–1000 µg/m³) and ≤±10 µg/m³ (0–100 µg/m³) at –20–50°C |
| Extended Accuracy | ±20% (100–1000 µg/m³) and ≤±20 µg/m³ (0–100 µg/m³) at –40––20°C & 50–70°C |
| Particle Size Range | 0.3–2.5–10 µm |
| Operating Environment | –40 to +85°C, 0–95% RH (non-condensing) |
| Communication Interface | LIN Bus |
| Brand | Cubic |
|---|---|
| Origin | Hubei, China |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | AQM-1020 |
| Pricing | Available Upon Request |
| Sensing Principle | Metal Oxide Semiconductor (MOX) |
| Target Gases | CO, NO₂, NH₃ (optional) |
| Maximum Gas Flow Rate | ≤10 m/s |
| Operating Temperature | −40 °C to +85 °C |
| Storage Temperature | −40 °C to +120 °C |
| Relative Humidity Range | 0–99% RH (non-condensing) |
| Supply Voltage | 9–16.2 V DC (nominal 12 V DC) |
| Operating Current | ≤40 mA |
| Standby Current | ≤100 µA |
| Ingress Protection | IP6K7 |
| Communication Interface | LIN bus / PWM output |
| Key | Brand: Cubic |
|---|---|
| Model | ATRS-1021 |
| Gas Detection Principle | CO₂ – NDIR |
| Measurement Ranges | CO₂: 0–10,000 ppm |
| CO/HC/H₂ | 1–1,000 ppm |
| PM | 0–5 mg/m³ |
| Pressure | 80–120 kPa |
| Temp | −40–125 °C |
| Accuracy | CO₂: ±(50 ppm + 5% of reading) |
| CO/HC/H₂ | ±40 ppm or ±30% of reading (whichever is greater) |
| PM | ≤100 µg/m³ → ±15 µg/m³, >100 µg/m³ → ±15% of reading |
| Pressure | ±0.1 kPa |
| Temp | ±2 °C |
| Resolution | CO₂/CO/HC/H₂: 1 ppm |
| PM | 1 µg/m³ |
| Pressure | 0.1 kPa |
| Temp | 0.1 °C |
| Response Time (T90) | CO₂ <15 s |
| Data Refresh Rate | ≤1 s |
| Output Interface | CAN (default), LIN, UART |
| Operating Temp | −40–85 °C |
| Humidity | 0–99% RH (non-condensing) |
| Power Supply | 9–16 VDC (nominal 12 VDC) |
| Avg. Current | ≤150 mA (normal), ≤50 mA (low-power mode), <100 µA (sleep) |
| Enclosure Rating | IP65 |
| Expected Service Life | ≥15 years (CO₂ & MOX sensors) |
| Brand | Cubic |
|---|---|
| Origin | Hubei, China |
| Model | ATRS-1031 |
| Detection Principle | Infrared Light Scattering (PM), NTC Thermistor (Temperature) |
| Measurable Parameters | PM₂.₅/PM₁₀ (1–10,000 µg/m³), Temperature (−40 to +85 °C) |
| Resolution | 1 µg/m³ (PM), 0.1 °C (T) |
| Accuracy | ±15 µg/m³ (≤100 µg/m³), ±15% of reading (>100 µg/m³) |
| Response Time | ≤1 s |
| Output Interface | CAN 2.0B |
| Protection Rating | IP40 |
| Operating Voltage | 6–16 VDC (nominal 12 VDC) |
| Current Consumption | ≤30 mA (active), ≤500 µA (low-power mode), ≤50 µA (deep sleep) |
| Design Lifetime | 10 years |
| Operating Environment | −40 to +85 °C, 0–99% RH (non-condensing) |
| Storage Range | −40 to +95 °C, 0–99% RH (non-condensing) |
| Pressure Range | 60–120 kPa |
| Brand | Cubic |
|---|---|
| Origin | Hubei, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | CM1107 |
| Detection Principle | Non-Dispersive Infrared (NDIR) |
| Measurement Range | 0–5000 ppm (customizable up to 12,000 ppm) |
| Warm-up Time | ≤30 s |
| Data Update Rate | 1 Hz |
| Accuracy | ±(30 ppm + 3% of reading) at 25°C±2°C, 50%±10% RH |
| Operating Temperature | −10°C to +50°C |
| Operating Humidity | 0–95% RH (non-condensing) |
| Storage Conditions | −30°C to +70°C, 0–95% RH (non-condensing) |
| Supply Voltage | DC 5 V ±0.1 V |
| Average Current Consumption | <70 mA |
| Output Interfaces | UART TTL (3.3 V / 5 V), I²C, PWM |
| Dimensions (L×W×H) | 33 mm × 21.7 mm × 10 mm (excluding pins) |
| Brand | Cubic |
|---|---|
| Origin | Hubei, China |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China-made) |
| Model | CM2201 |
| Price | USD 700 (FOB) |
| Detection Principle | Non-Dispersive Infrared (NDIR) |
| Measurement Range | 0–150 mmHg |
| Resolution | 0.1 mmHg |
| Accuracy | ±2 mmHg (0–40 mmHg), ±5% of reading (41–70 mmHg), ±8% (71–100 mmHg), ±10% (100–150 mmHg) |
| Respiratory Rate Range | 0–150 BPM |
| Respiratory Rate Accuracy | ±1 BPM |
| Short-Term Drift | ≤0.8 mmHg (4 h) |
| Long-Term Drift | Maintains Specified Accuracy over 120 h |
| Supply Voltage | 5.00 V ±5% |
| Avg. Current Draw | <120 mA |
| Peak Current | <250 mA |
| Warm-up Time to Display | ≤15 s |
| Time to Full-Spec Accuracy | ≤2 min (at 25°C) |
| Barometric Pressure Compensation | 400–850 mmHg |
| Operating Temp. | 0–45°C, 10–90% RH (non-condensing) |
| Storage Temp. | −40–70°C, <90% RH (non-condensing) |
| Interface | RS232, 19200-N-8-1 |
| Dimensions | 52 × 23 × 36 mm |
| Brand | Cubic |
|---|---|
| Origin | Hubei, China |
| Model | Gasboard-2006 |
| Measurement Principle | Non-Dispersive Infrared (NDIR) |
| Target Gases | Carbon Monoxide (CO), Carbon Dioxide (CO₂) |
| CO Range | 0–1000 ppm (1 ppm resolution) |
| CO₂ Range | 0–20 vol.% (0.01 vol.% resolution) |
| CO Detection Limit | 0.5% FS |
| CO₂ Detection Limit | 0.1% FS |
| Linearity Error | ≤ ±1% FS |
| Repeatability | ≤ ±1% FS |
| Drift | ≤ ±2% FS / 24 h |
| Response Time (T₉₀) | < 8 s @ 0.7 L/min |
| Sample Flow Rate | 0.2–1.0 L/min |
| Internal Thermostat | 50 °C ±0.5 °C |
| Warm-up Time | < 30 min |
| Operating Ambient Temperature | 5–40 °C |
| Relative Humidity | 0–95% RH (non-condensing) |
| Atmospheric Pressure | 86–115 kPa |
| Power Supply | 12 VDC ±0.2 V |
| Max Power Consumption | 36 W (heating active), < 800 mW (standby) |
| Communication Interface | RS-232 / RS-485 (Modbus RTU protocol) |
| Housing | Modular OEM-grade metal enclosure with integrated optical gas cell |
| Brand | Cubic |
|---|---|
| Origin | Hubei, China |
| Model | Gasboard-2501-05F |
| Detection Principle | Tunable Diode Laser Absorption Spectroscopy (TDLAS) |
| Target Gas | Methane (CH₄) |
| Measurement Range | 0–100% LEL |
| Accuracy | ±5% LEL |
| Resolution | 0.1% LEL |
| Response Time (T90) | <20 s |
| Operating Temperature | −25 °C to +55 °C |
| Operating Humidity | 0–98% RH (non-condensing) |
| Storage Conditions | −40 °C to +85 °C, 0–98% RH (non-condensing) |
| Supply Voltage | 3.2 V–5.5 V DC |
| Output Interface | TTL (3.0 V logic level) |
| Typical Current Consumption | 15 mA |
| Expected Service Life | ≥10 years |
| Selectivity | High specificity to CH₄ |
| Brand | Cubic |
|---|---|
| Model | Gasboard-2600 |
| Detection Principle | Tunable Diode Laser Absorption Spectroscopy (TDLAS) |
| Measuring Gas | O₂ |
| Range | 0–100% vol |
| Accuracy | ±0.3% FS |
| Resolution | 0.01% vol |
| Response Time | 100–170 ms (10–90%, at 150–350 mL/min) |
| Warm-up Time | <25 s |
| Operating Temp. | −10 to +50 °C |
| Humidity | 0–95% RH (non-condensing) |
| Output | RS-232 (default), RS-485 (optional), (0–1) V analog |
| Supply Voltage | 12 V ±10% |
| Current Draw | 1.8 A |
| Dimensions | 180 × 60 × 30 mm |
| Lifetime | ≥10 years |
| Optional Dual-Gas Configuration | O₂ + CO₂ (NDIR) |
| Brand | Cubic |
|---|---|
| Origin | Hubei, China |
| Model | Gasboard-7500H-OPC |
| Measurement Principle | Ultrasonic Transit-Time Difference |
| Flow Range | 0–5 L/min |
| Accuracy | ±3% FS or ±0.06 L/min (at 5–45 °C) |
| Response Time | ≤0.3 s |
| Operating Temperature | −20 °C to +60 °C |
| Relative Humidity | 0–95% RH (non-condensing) |
| Supply Voltage | DC 4.75–12.6 V (ripple ≤50 mV) |
| Current Consumption | ≤35 mA |
| Interface | UART TTL (3.3 V logic level) |
| Dimensions | 80 × 22 × 25 mm (W × H × D) |
| EMC Compliance | Certified per IEC/EN 61000-6-2 & 61000-6-4 |
| Regulatory Approvals | CE, CMC |
| Brand | Cubic |
|---|---|
| Origin | Hubei, China |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | Gasboard-8500V |
| Price | USD 149 (FOB) |
| Detection Principle | Ultrasonic Time-of-Flight (TOF) |
| Measurement Range | 20.5–100% O₂ (binary gas mixtures) |
| Accuracy | ±3% FS @ 5–45°C |
| Resolution | 0.1% O₂ |
| Response Time | <15 s (T90) |
| Operating Temp. | 5–50°C |
| Humidity Range | 0–95% RH (non-condensing) |
| Storage Temp. | −20–50°C |
| Supply Voltage | DC 4.75–12.5 V |
| Avg. Current Draw | <35 mA |
| Output Signal | 0–2500 mV analog |
| Dimensions | 46 × 29.3 × 29.3 mm (L×W×D) |
| Brand | CUBIC INSTRUMENTS |
|---|---|
| Origin | Hubei, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | CJH-5 |
| Pricing | Available Upon Request |
| Measurement Principle | NDIR (Non-Dispersive Infrared) |
| Target Gas | Methane (CH₄) |
| Measurement Range | 0–100% LEL |
| Accuracy | ±5% F.S. |
| Resolution | 1% LEL |
| Response Time (T90) | <30 s |
| Warm-up Time | 30 s |
| Sampling Method | Diffusion |
| Explosion Protection Rating | Ex d II C T6 Gb |
| Output Signals | RS-485 (Modbus RTU), Dual SPST Relay Contacts (NO), 4–20 mA Analog Output |
| Operating Temperature | −20 to +60 °C |
| Storage Temperature | −40 to +85 °C |
| Humidity Range | ≤95% RH (non-condensing) |
| Display | Backlit LCD |
| Zero Calibration | Automatic drift compensation with temperature-compensated baseline correction |
| Power Supply | DC 12–24 V |
| Sensor Lifetime | >5 years (typical, non-consumable optical path) |
| Brand | CUBIC INSTRUMENTS |
|---|---|
| Origin | Hubei, China |
| Model | Gasboard-2061 |
| Detection Principle | Non-Dispersive Infrared (NDIR) |
| Target Gases | WF₆, CF₄, SF₆, NF₃, CO₂ |
| Range | 1–264 ppm (0–200 mTorr) |
| Repeatability | ±0.5% |
| Linearity | ±1% F.S. |
| Detection Limit | 1 ppm |
| Output | Analog & Digital |
| Design | Modular, OEM-Ready |
| Compliance | Compatible with SEMI E19/E30/E37 standards |