Gas Chromatograph
Filter
Showing 61–90 of 135 results
| Brand | EXPEC (Puyu Technology) |
|---|---|
| Origin | Zhejiang, China |
| Instrument Type | Online Gas Chromatograph |
| Detection Principle | GC-FID (Gas Chromatography with Flame Ionization Detection) |
| Explosion Protection | Ex d e ib px IIC T3/T4 Gb |
| Core Detector | Explosion-Proof FID |
| Sampling Method | High-Temperature Heated Probe + Heated Sample Line + Heated Pre-treatment Unit |
| Data Output | Real-time Temperature, Pressure, Flow Rate, Humidity, O₂ Content, NMHC, Benzene, Toluene, Ethylbenzene, Xylenes (BTEX) |
| Compliance | Designed for EPA Method 25A / ISO 12039 / HJ 1012-2018 Environments |
| Power Supply | 220 VAC ±10%, 50 Hz |
| Operating Ambient | –10 °C to +50 °C |
| Enclosure Rating | IP65 |
| Brand | EXPEC / Superspec |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Authorized Distributor |
| Regional Classification | Domestic (China) |
| Model | EXPEC 2000 |
| Instrument Type | Online Gas Chromatograph |
| Detection Configurability | FID, MSD, or PID Detectors |
| Target Analytes | Methane / NMHC, BTEX, Methanol, Acetone, and >100 Volatile Organic Compounds |
| Sampling Line Material | Stainless Steel or PTFE Low-Adsorption Tubing |
| Software Interface | Localized Chinese GUI with Audit-Trail-Capable Control Platform |
| Footprint | ≥1 m² (Modular Cabinet Design, Indoor/Outdoor Deployment Options) |
| Compliance | GB/T 38394–2019, HJ 1012–2018, HJ 759–2015 |
| Brand | EXPEC / Puyu Technology |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Authorized Distributor |
| Regional Category | Domestic (China) |
| Model | EXPEC 2000 |
| Instrument Type | Online Gas Chromatograph |
| Detection Methods | UV Fluorescence (H₂S), Chemiluminescence (NH₃), GC-NPD (methylamine, dimethylamine, trimethylamine), GC-FPD (methanethiol, methyl sulfide, carbon disulfide, dimethyl disulfide), GC-FID (styrene) |
| Detection Limit | As low as 0.1 ppb for selected compounds |
| Cabinet Format | 19-inch standard rack-mount enclosure |
| Compliance | Aligned with GB 14554–2018 (Draft Revision), HJ 1227–2021, and related Chinese environmental monitoring standards |
| Brand | EXPEC |
|---|---|
| Origin | Zhejiang, China |
| Model | EXPEC 3050 |
| Instrument Type | Portable Gas Chromatograph with Integrated FID |
| Weight | ~2.0 kg |
| Compliance | GB 37822–2019, HJ 733–2014, HJ 1019–2019 |
| Optional Configuration | FID + PID dual-detector mode |
| Power Supply | Rechargeable Li-ion battery (operational runtime ≥ 4 h) |
| Detection Principle | Catalytic combustion-assisted flame ionization detection |
| Brand | EXPEC (Hangzhou Superspectra Technology Co., Ltd.) |
|---|---|
| Origin | Zhejiang, China |
| Model | EXPEC 3100 |
| Instrument Type | Portable Gas Chromatograph with Flame Ionization and Photoionization Detectors |
| Compliance | GB 37822–2019, HJ 733–2014, HJ 1019–2019 |
| Weight | 3.7 kg |
| Response Time | < 3.5 s (FID/PID) |
| Detector Options | FID (standard), PID (optional) |
| Explosion Protection | Intrinsically Safe (handheld controller), Flameproof (FID module), Certified for Class I, Division 1 hazardous locations |
| Brand | EXPEC/Spectrum Instruments |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | EXPEC 3200 |
| Instrument Type | Portable Gas Chromatograph |
| Detection Principle | High-Temperature Catalytic Oxidation + Flame Ionization Detection (FID) |
| Detection Limit | Sub-ppb Level for THC/Methane/NMHC |
| Compliance | HJ 1012–2018, Local NMHC Field Monitoring Standards (Beijing, Tianjin, Shandong, Fujian, Jiangxi, Henan) |
| Brand | EXPEC (Puyu Technology) |
|---|---|
| Origin | Zhejiang, China |
| Model | GC 2000 |
| Instrument Type | Benchtop Laboratory Gas Chromatograph |
| Electronic Pressure Control (EPC) | Up to 6 modules, controlling up to 18 gas channels |
| EPC Precision | 0.001 psi |
| Sample Path Surface Treatment | Ultra-inert deactivation for N/O/S/P-containing compounds |
| Operating System | Android-based open platform with touch interface |
| Software | Legacy-compatible workstation with sequence/method editing, real-time chromatogram display, multi-sample statistical comparison and trend visualization |
| Compliance Support | Designed for GLP/GMP environments |
| Brand | Fortel |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Laboratory Gas Chromatograph |
| Model | F70Pro |
| Application Scope | General-Purpose Analysis |
| Detector Options | FID, TCD, ECD, FPD, NPD |
| Brand | Fortel |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Laboratory Gas Chromatograph |
| Model | F80 |
| Application Scope | General-Purpose |
| EPC Generation | 4th-Generation Electronic Pressure Control (EPC) |
| Column Oven Design | Platinum Resistance Temperature Sensor with Unobstructed Mounting |
| Safety Features | Dual-Temperature Monitoring, Hydrogen Auto-Shutoff, DC Heating, Flame-Retardant Materials |
| Detector Options | Multiple Configurable Detectors |
| Flow Path Flexibility | Multi-Valve/Multi-Column Support, Deans Switch, Micro-Flow Center-Cut, Comprehensive 2D-GC Ready |
| Software Platform | MyLab Chromatography Workstation (Web-Based Remote Access via PC/Tablet/Smartphone) |
| Compliance Context | Designed for GLP/GMP-aligned laboratories |
| Brand | FPI |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Type | Portable Gas Chromatograph |
| Application Scope | General-purpose Environmental Emission Monitoring |
| Compliance Standards | HJ 1012, HJ 38, HJ 604, GB 37822–2019 |
| Detection Principle | High-Temperature Heated Sample Transfer + Flame Ionization Detection (FID) |
| Detection Limit | Sub-ppb Level for Total Hydrocarbons, Methane, and BTEX |
| Integrated Power Supply | Rechargeable Lithium Battery (≥4 h continuous operation with heated line) |
| Data Output | Raw Chromatograms & Quantitative Results Exportable in Standard Formats (e.g., .csv, .cdf) |
| Certification | China Metrology Accreditation (CPA), Compatible with CMA Reporting Requirements |
| Sample Introduction | Dual-Stage Filtered Sampling Pump + Fixed-Volume Loop Injection |
| Column Configuration | Capillary GC Column Optimized for C1–C8 Hydrocarbons |
| Detector Temperature | Up to 180 °C |
| Sample Line Temperature | Heated to 180 °C |
| Dimensions & Portability | Integrated All-in-One Chassis with Carrying Handle |
| Optional Accessories | Android Tablet Interface, High-Pressure Gas Cylinders, Metal Hydride Hydrogen Generators |
| Brand | FPI |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Instrument Category | Domestic Lab-Scale Gas Chromatograph |
| Model | GC-2000 Universal |
| Application Scope | General-Purpose Analytical Chemistry |
| Control Interface | Full-Touch Color LCD Display |
| Pneumatic Control | Electronic Pressure and Flow Control (EPC) |
| Software Architecture | Modular Workstation with Method-Driven Workflow |
| Microfluidic Capability | Valveless Flow Switching for Column Back-Flush, Detector Selection, and GC-MS Parallel Operation |
| Compliance Context | Designed for GLP/GMP-aligned laboratories |
| Brand | Fuli |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Manufacturer |
| Product Category | Domestic |
| Model | F60 |
| Instrument Type | Laboratory Gas Chromatograph |
| Application Scope | General-purpose |
| Detector Options | FID, FPD |
| Control Interface | 7-inch TFT capacitive touchscreen |
| Gas Control | Mechanical valves with electronic pressure & flow monitoring |
| Column Oven | Dual-sensor temperature monitoring, thermal fuse protection, flame-retardant materials (UL94 V-0 rated) |
| Compliance | Designed to support GLP/GMP workflows, ASTM D3606/D1319, ISO 17025-aligned operation |
| Brand | Fuli |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | F70 |
| Instrument Type | Laboratory Gas Chromatograph |
| Application Scope | General-Purpose Analysis |
| Control Architecture | Dual-AFC (Carrier Gas & Detector Auxiliary Gas) or Full-AFC Mode |
| Detection Systems | FID, FPD (Wide-Range Configurable) |
| Injection Options | Multiple Configurable Inlet Types |
| Software Platforms | FL97Plus, MyLab Chromatography Data Systems (CDS) |
| Compliance Framework | Designed for GLP/GMP-aligned workflows with audit trail-ready CDS options |
| Human-Machine Interface | 7-inch capacitive touchscreen with real-time multi-channel status visualization |
| Maintenance Intelligence | Consumables tracking (septa, liner, split cold trap), usage-based alerts, and automated leak-check protocol |
| Brand | Fuli |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | F70 |
| Instrument Type | Laboratory Gas Chromatograph |
| Application Scope | General-Purpose |
| Oven Temperature Range | 6 °C to 400 °C |
| Maximum Ramp Rate | 120 °C/min |
| Cooling Rate | <7.0 min from 350 °C to 50 °C |
| Carrier Gas Flow Range & Control | 0–450 mL/min |
| Carrier Gas Pressure Range & Control | 0–100 psi |
| Electronic Pressure Control (EPC), pressure setting resolution | 0.01 psi |
| Injector Maximum Operating Temperature | 400 °C |
| Injector Pressure Setting Range | 0–100 psi |
| Injector Total Flow Setting Range | 0–450 mL/min |
| Brand | Fulit |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | F60 |
| Instrument Type | Laboratory Gas Chromatograph |
| Application Scope | General-Purpose |
| Temperature Control Range | 6°C to 400°C |
| Maximum Ramp Rate | 120°C/min |
| Cooling Time | <7.0 min (from 350°C to 50°C) |
| Carrier Gas Flow Control | Electronic Flow Display |
| Carrier Gas Pressure Control | Electronic Pressure Display |
| Injector Maximum Operating Temperature | 400°C |
| Brand | Fulit |
|---|---|
| Origin | Zhejiang, China |
| Model | F70pro |
| Instrument Type | Laboratory Gas Chromatograph |
| Application Scope | General-purpose |
| Oven Temperature Range | 6 °C to 400 °C |
| Maximum Ramp Rate | 120 °C/min |
| Cooling Rate | <3.0 min from 200 °C to 100 °C |
| Carrier Gas Flow Range & Control | 0–450 mL/min with Electronic Pressure Control (EPC) for carrier gas and Automatic Flow Control (AFC) for auxiliary gases |
| Carrier Gas Pressure Range & Control | 0–100 psi with EPC |
| pressure control resolution | 0.001 psi |
| Injector Maximum Operating Temperature | 400 °C |
| Injector Pressure Setting Range | 0–100 psi |
| Injector Total Flow Setting Range | 0–450 mL/min |
| Brand | Fulit |
|---|---|
| Origin | Zhejiang, China |
| Model | F80 |
| Instrument Type | Benchtop Laboratory Gas Chromatograph |
| Application Scope | General-Purpose GC Analysis |
| Oven Temperature Range | 4 °C to 450 °C |
| Maximum Ramp Rate | 250 °C/min |
| Cooling Rate | <5.0 min from 450 °C to 50 °C |
| Carrier Gas Flow Range & Control | 0–1250 mL/min (H₂ or He), 0–500 mL/min (N₂) |
| Carrier Gas Pressure Range & Control | 0–100 psi (standard), optional 0–150 psi |
| Injector Maximum Operating Temperature | 450 °C |
| Injector Pressure Setting Range | 0–100 psi (standard), optional 0–150 psi |
| Injector Total Flow Setting Range | 0–1250 mL/min (H₂/He), 0–500 mL/min (N₂) |
| Control System | Integrated high-resolution touchscreen interface with embedded real-time GC control firmware |
| Brand | Huazhun Chromatography |
|---|---|
| Model | GC-2021plus |
| Origin | Jiangxi, China |
| Instrument Type | Laboratory Gas Chromatograph |
| Application Scope | General-purpose |
| Oven Temperature Range | 5 °C to 450 °C |
| Maximum Ramp Rate | 250 °C/min |
| Cooling Rate | ≤8 min (from 350 °C to 50 °C at 25 °C ambient) |
| Carrier Gas Flow Control Range | 0–200 mL/min (N₂), 0–1250 mL/min (H₂ or He) |
| Carrier Gas Pressure Control Range | 0–1035 kPa (0–150 psi) |
| Injector Maximum Operating Temperature | 420 °C |
| Origin | Beijing, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (PRC) |
| Model | GC-4008B |
| Instrument Type | Benchtop Laboratory Gas Chromatograph |
| Application Domain | Coal Mining Safety & Spontaneous Combustion Monitoring |
| Detection Systems | TCD, Dual FID, ECD, FPD |
| Column Configuration | Four Dedicated Capillary/Packed Columns |
| Temperature Program | 10-Stage Programmable Ramp |
| Carrier Gases | Helium (TCD), Hydrogen/Air (FID), Nitrogen (ECD/FPD) |
| Minimum Detectable Concentrations | CO, C₂H₂ ≤ 0.5 ppm |
| [Brand | Lunan Ruihong |
|---|---|
| Origin | Shandong, China |
| Instrument Type | Laboratory Gas Chromatograph |
| Application Scope | General-Purpose |
| Oven Temperature Range | 4 °C to 450 °C |
| Ramp Rate | 0.1–80 °C/min |
| Cool-down Rate | ≤3 min (200 °C → 100 °C) |
| Carrier Gas Flow Control Range | 0–1000 mL/min |
| Carrier Gas Pressure Control Range | 0–100 psi |
| Injector Max Temp | 450 °C |
| Injector Pressure Setpoint Range | 0–100 psi |
| Temperature Zones | 8 independent zones |
| Programmed Temperature Steps | up to 16 ramps |
| Detector Options | FID, TCD, ECD, FPD, NPD (up to 3 simultaneously)] |
| Brand | HuaiAi |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Origin | Domestic (China) |
| Model | GC-9560-HT |
| Price Range | USD 7,000 – 14,000 |
| Instrument Type | Laboratory Gas Chromatograph |
| Application Scope | General-Purpose |
| Oven Temperature Range | Ambient +8°C to 399°C |
| Maximum Ramp Rate | 40°C/min |
| Cooling Rate | 350°C → 50°C in <5 min |
| Carrier Gas Flow Range & Control | 0–500 mL/min |
| Carrier Gas Pressure Range & Control | 0–0.4 MPa |
| Injector Maximum Operating Temperature | 399°C |
| Injector Pressure Setting Range | 0–0.4 MPa |
| Injector Total Flow Setting Range | 0–500 mL/min |
| Brand | JKRD |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | SP7800 |
| Instrument Type | Laboratory Gas Chromatograph |
| Application Scope | General-Purpose Analysis |
| Warranty & Service | On-site Installation, Commissioning, and Comprehensive After-Sales Support |
| Brand | KA |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Regional Classification | Domestic (China) |
| Model | hytrace Integrated Analyzer |
| Instrument Type | Portable Gas Chromatograph |
| Application Scope | General-purpose, Hydrogen Purity Monitoring |
| Oven Temperature Range | Ambient +4 °C to 450 °C |
| Ramp Rate | Up to 75 °C/min |
| Cool-down Time | ~6 min (from 400 °C to 50 °C) |
| Carrier Gas Flow Control Range | 30–100 mL/min |
| Carrier Gas Pressure Control Range | 90–100 psig |
| Injector Maximum Temperature | 400 °C |
| Injector Pressure Setting Range | 3–25 psig |
| Injector Total Flow Setting Range | 5–200 mL/min |
| Brand | Kechuang |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Benchtop Laboratory Gas Chromatograph |
| Application Domain | Food Safety & Agricultural Residue Testing |
| Oven Temperature Range | +5 °C to 400 °C |
| Maximum Ramp Rate | 40 °C/min |
| Cooling Time (from 400 °C to 50 °C) | ≤4 min |
| Carrier Gas Flow Range | 0–1000 mL/min |
| Carrier Gas Pressure Control Range | 0–100 psi |
| Injector Temperature Range | +5 °C to 400 °C |
| Injector Pressure Setting Range | 0–0.04 MPa |
| Total Injector Flow Setting Range | 0–1000 mL/min |
| Column Oven Dimensions | 280 × 280 × 180 mm |
| Weight | 56 kg |
| Power Consumption | 2000 W |
| Brand | LABA |
|---|---|
| Origin | USA |
| Model | G5 GC |
| Instrument Type | Laboratory Gas Chromatograph |
| Application Scope | Universal |
| Temperature Control Range | Ambient to 850 °C |
| Oven Ramp Rate | 0.01–500 °C/min |
| Oven Cool-down Rate | ~1 min (850 °C → 0 °C) |
| Carrier Gas Flow Range & Control | 0–25,000 mL/min |
| Carrier Gas Pressure Range & Control | 0.001–100,000 psi |
| Injector Maximum Operating Temperature | 850 °C |
| Injector Pressure Setting Range | 0.001–100,000 psi |
| Injector Total Flow Setting Range | 0.0001–10,000 mL/min |
| Detector Sensitivity (ECD) | ≤10⁻¹⁵ g/s (for γ-HCH) |
| Brand | Lunan Ruihong |
|---|---|
| Model | GC-55 |
| Type | Laboratory Gas Chromatograph |
| Temperature Control Range | 4 °C to 450 °C |
| Ramp Rate | 0.1–120 °C/min |
| Cool-down Time | ≤4 min (450 °C → 50 °C) |
| Carrier Gas Flow Range | 0–1000 mL/min |
| Carrier Gas Pressure Range | 0–100 psi |
| Injector Max Temp | 450 °C |
| Injector Pressure Setpoint Range | 0–100 psi |
| Injector Total Flow Setpoint Range | 0–500 mL/min |
| Temperature Zones | 8 independent zones |
| Programmed Temperature Steps | up to 100 steps |
| Temperature Resolution | 0.01 °C |
| Temperature Accuracy | ±0.01 °C |
| EPC/EFC Resolution | 0.001 psi / 0.001 mL/min |
| Maximum Split Ratio | 1:1000 |
| Detector Support | FID, TCD, ECD, FPD, NPD (up to 4 simultaneously) |
| Data Interface | Ethernet IEEE 802.3 (MODBUS/TCP compliant) |
| Display | 10.1″ capacitive color touchscreen |
| Brand | Lunan Ruihong |
|---|---|
| Model | GC-8850 |
| Origin | Shandong, China |
| Instrument Type | Laboratory Gas Chromatograph |
| Temperature Control Range | 4 °C to 450 °C |
| Ramp Rate | 0.1–60 °C/min |
| Cooling Rate | 300 °C to 50 °C in ~8 min |
| Carrier Gas Flow Range | 0–1000 mL/min |
| Carrier Gas Pressure Range | 0–400 kPa |
| Programmable Pressure/Flow Steps | 16 |
| Injector Max Temp | 420 °C |
| Injector Pressure Setpoint Range | 0–400 kPa |
| Injector Total Flow Setpoint Range | 0–1000 mL/min |
| Temperature Zones | 8 independent zones |
| Temperature Resolution | 0.5 °C |
| Temperature Accuracy | ±0.1 °C |
| Detector Options | FID, TCD, ECD, FPD, NPD (up to 3 simultaneously) |
| Data Interface | 10/100/1000BASE-T Ethernet (IEEE 802.3), MODBUS/TCP compliant |
| Display | 7-inch color capacitive touchscreen (hot-swappable, handheld-capable) |
| Analog-to-Digital | 24-bit low-noise ADC with baseline storage and subtraction |
| External Events | 8 inputs, 2 auxiliary outputs |
| Injection Modes | Packed column, capillary column, 6-port gas valve, optional autosampler |
| Brand | LuNan RuiHong |
|---|---|
| Model | QT-3000 |
| Instrument Type | Laboratory Gas Chromatograph |
| Application Field | Petroleum & Petrochemical Industry |
| Column Oven Temperature Range | +5°C above ambient to 250°C |
| Temperature Control Accuracy | ±0.1°C (column oven), ±1°C (inlet/detector) |
| Max Heating Rate | 20°C/min |
| Cooling Time | ≤8 min (180°C → 35°C) |
| FID Detection Limit | ≤1×10⁻¹¹ g/s (benzene) |
| FID Drift | ≤0.5 mV/h |
| Maximum Temperature Program Steps | 4 |
| Injector | Water-Driven 6-Port Sampling Valve + Manual Syringe Port |
| Software | Dedicated Light Hydrocarbon Qualitative/Quantitative Data Processing Suite |
| Compliance | Designed for ASTM D1945, ASTM D1946, ISO 6974-1, and GB/T 13610-compliant light hydrocarbon analysis workflows |
| Brand | Lunan Ruihong |
|---|---|
| Origin | Shandong, China |
| Model | SP-6801A |
| Instrument Type | Benchtop Laboratory Gas Chromatograph |
| Temperature Control Range | Ambient +3°C to 399°C |
| Temperature Stability | ±0.1°C |
| Temperature Accuracy | ±3% of setpoint |
| Oven Cooling Rate | ~8 minutes from 250°C to 50°C |
| FID Detection Limit | ≤5×10⁻¹¹ g/s (n-hexadecane in iso-octane) |
| FID Linear Range | ≥10⁶ |
| TCD Sensitivity | ≥2000 mV·mL/mg (benzene/toluene) |
| TCD Linear Range | ≥10⁴ |
| ECD Detection Limit | ≤5×10⁻¹³ g/mL (γ-HCH in iso-octane) |
| Brand | Lunan Ruihong |
|---|---|
| Origin | Shandong, China |
| Model | SP-7890Plus |
| Instrument Type | Laboratory Gas Chromatograph |
| Application Scope | General-Purpose |
| Temperature Control Range | 4°C above ambient to 450°C |
| Heating Rate | 0.1–80°C/min |
| Cooling Rate | ≤2 min from 200°C to 100°C |
| Carrier Gas Flow Range & Control | 0–1000 mL/min |
| Carrier Gas Pressure Range & Control | 0–100 psi |
| Injector Maximum Operating Temperature | 450°C |
| Total Injector Flow Setting Range | 0–1000 mL/min |