Gas Chromatograph
Filter
Showing 91–120 of 135 results
| Brand | PerkinElmer |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | Clarus 580 |
| Instrument Type | Laboratory Gas Chromatograph |
| Application Scope | General-Purpose |
| Temperature Control Range | Not Specified |
| Oven Ramp Rate | Not Specified |
| Cooling Rate | Not Specified |
| Carrier Gas Flow Range & Control | Not Specified |
| Carrier Gas Pressure Range & Control | Not Specified |
| Injector Maximum Operating Temperature | Not Specified |
| Injector Pressure Setting Range | Not Specified |
| Injector Total Flow Setting Range | Not Specified |
| Brand | PerkinElmer |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Category | Imported Instrument |
| Model | Clarus 590 / Clarus 690 |
| Instrument Type | Laboratory Gas Chromatograph |
| Application Scope | Universal (Food, Pharmaceuticals, Petrochemicals, Environmental Analysis) |
| Software Platform | TotalChrom™ Chromatography Data System (CDS) |
| Regulatory Compliance Support | 21 CFR Part 11, GLP/GMP Audit Trail Capabilities |
| Automation Platform | TurboMatrix™ MultiPrep Autosampler (Liquid, Headspace, SPME) |
| Flow Control Technology | Swafer™ Micro-Channel Pneumatic Control |
| Detector Options | FID, TCD, ECD, NPD, FPD, PID |
| Inlet Types | Split/Splitless, PTV, Cold On-Column, Packed Column |
| Column Oven | Patented concentric exhaust design (Clarus 690) |
| Brand | PerkinElmer |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | Clarus 680 |
| Instrument Type | Laboratory Gas Chromatograph |
| Application Scope | General-Purpose |
| Temperature Control Range | Not Specified |
| Oven Ramp Rate | Not Specified |
| Oven Cool-Down Rate | Not Specified |
| Carrier Gas Flow Range & Control | Not Specified |
| Carrier Gas Pressure Range & Control | Not Specified |
| Injector Maximum Operating Temperature | Not Specified |
| Injector Pressure Setting Range | Not Specified |
| Injector Total Flow Setting Range | Not Specified |
| Brand | PerkinElmer |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported Instrument |
| Model | Clarus 680 GC |
| Pricing | Available Upon Request |
| Brand | PerkinElmer |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported Instrument |
| Model | GC 2400 |
| Instrument Type | Laboratory Gas Chromatograph-Mass Spectrometer |
| Application Scope | General-Purpose GC-MS Analysis |
| Key Feature | Integrated Split Touchscreen Control Interface |
| Detection Technology | Quadrupole Mass Spectrometry (MS 2400 SQ) with Clarifi™ Detector |
| Sample Introduction | Smart Liquid Autosampler with Pressure-Balanced Injection |
| Safety System | Integrated Hydrogen Sensor |
| Source Technology | SMARTsource™ Replaceable Ion Source |
| Software Platform | Simplicity™ GC/MS Workstation |
| Brand | Persee |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Laboratory Gas Chromatograph |
| Model | G5 |
| Application Scope | General-Purpose |
| Oven Temperature Range | Ambient +7°C to 400°C |
| Max. Number of Simultaneous Inlet/Detector Mounts | 3 |
| Temperature Program Steps | 10-step |
| Inlet/Detector Configuration Flexibility | Modular |
| Carrier Gas Control | Digital Precision Flow/Pressure Regulation |
| Compliance | Designed to meet core requirements of ISO/IEC 17025, ASTM D3606, USP <621>, and FDA 21 CFR Part 11 for data integrity |
| Brand | Persee |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Benchtop Laboratory Gas Chromatograph |
| Model | G600 |
| Temperature Control Range | 7 °C above ambient to 400 °C |
| Oven Ramp Rate | 0.1–40 °C/min (adjustable in 0.1 °C increments) |
| Maximum Injector Temperature | 450 °C |
| Injector Configuration | Up to three independently configurable inlets |
| Column Oven Cooling | Forced-air active cooling |
| Detector Options | FID, TCD, ECD, PID (field-selectable) |
| Compliance | GLP/GMP-ready software audit trail, 21 CFR Part 11–compatible data handling |
| Brand | Persee |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Benchtop Laboratory Gas Chromatograph |
| Application Scope | General-Purpose Analytical Chemistry |
| Maximum Column Oven Ramp Rate | 0–120 °C/min |
| Simultaneous Inlet Configuration | Up to 3 Independent Inlets |
| Compatible Detectors | TCD, FID, ECD, FPD, NPD, PDD, MSD |
| Flow Control System | Precision Smart Flow Control (SFC) |
| Inlet Temperature Capability | Not Specified |
| Pressure & Flow Ranges | Not Specified |
| Cooling Rate | Not Specified |
| Cloud-Enabled Features | Method Optimization Engine, Remote Fault Diagnostics, Centralized Method Library |
| Brand | Purkinje |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Laboratory Gas Chromatograph |
| Model | GC1100 |
| Temperature Control Range | Ambient +6°C to 399°C |
| Oven Ramp Rate | 0–30°C/min |
| Carrier Gas Flow Range | 0–1200 mL/min |
| Carrier Gas Pressure Range | 0–970 kPa |
| Injector Maximum Temperature | 200°C |
| Injector Pressure Setting Range | 0–970 kPa |
| Injector Total Flow Setting Range | 0–1200 mL/min |
| Column Oven Temperature Accuracy | ±0.1°C |
| Column Oven Temperature Gradient | ±1.5% |
| TCD Sensitivity | ≥4000 mV·mL/mg (n-hexadecane) |
| TCD Noise | ≤0.04 mV |
| TCD Baseline Drift | ≤0.2 mV/30 min |
| FID Detection Limit | ≤8×10⁻¹² g/s (n-hexadecane) |
| FID Noise | ≤0.02 mV |
| FID Baseline Drift | ≤0.2 mV/30 min |
| Dimensions (L×W×H) | 562×550×492.5 mm |
| Weight | 44 kg |
| Brand | Scion |
|---|---|
| Origin | Netherlands |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Laboratory Gas Chromatograph |
| Models | 436-GC, 456-GC |
| Temperature Control Range | Ambient +4 °C to 450 °C |
| Maximum Ramp Rate | 150 °C/min |
| Cooling Rate | ~4.5 min from 400 °C to 50 °C |
| Carrier Gas Flow Range & Control | 0–1500 mL/min |
| Carrier Gas Pressure Range & Control | 0–150 psi |
| Injector Maximum Operating Temperature | 450 °C |
| Injector Pressure Setting Range | 0–150 psi |
| Injector Total Flow Setting Range | 0–1500 mL/min |
| Detector Data Acquisition Rate | 600 Hz |
| Column Oven Configuration | Dual-channel (436-GC), Quad-channel (456-GC) |
| Injector Types Supported | Split/Splitless, PTV, Cool-on-Column, Direct Injection |
| Flow Control Mode | Constant Linear Velocity (CLV) |
| System Software | Compass CDS (integrated) |
| Compliance | ASTM, UOP, EN, ISO, GPA, USP methods |
| Brand | Scion |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Regional Classification | Domestic Instrument |
| Model | 436i |
| Instrument Type | Laboratory Gas Chromatograph |
| Application Scope | General-Purpose |
| Oven Temperature Range | –100 °C to 450 °C |
| Maximum Ramp Rate | 150 °C/min |
| Maximum Cool-Down Rate | 150 °C/min |
| Carrier Gas Flow Range & Control | 0–1500 mL/min |
| Carrier Gas Pressure Range & Control | 0–150 psi |
| Injector Maximum Operating Temperature | 450 °C |
| Injector Pressure Setting Range | 0–150 psi |
| Injector Total Flow Setting Range | 0–1500 mL/min |
| Brand | SCION |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Regional Classification | Domestic (China) |
| Model | 456i |
| Instrument Type | Laboratory Gas Chromatograph |
| Application Scope | General-Purpose |
| Oven Temperature Range | –100 °C to 450 °C |
| Maximum Ramp Rate | 150 °C/min |
| Maximum Cool-Down Rate | 150 °C/min |
| Carrier Gas Flow Range & Control | 0–1500 mL/min |
| Carrier Gas Pressure Range & Control | 0–150 psi |
| Injector Maximum Operating Temperature | 450 °C |
| Injector Pressure Setting Range | 0–150 psi |
| Injector Total Flow Setting Range | 0–1500 mL/min |
| Brand | SCION |
|---|---|
| Origin | Netherlands |
| Manufacturer | SCION Instruments B.V. |
| Instrument Type | Laboratory Gas Chromatograph |
| Application Scope | General-Purpose |
| Oven Temperature Range | Ambient to 450 °C |
| Maximum Ramp Rate | 170 °C/min |
| Maximum Cooling Rate | 150 °C/min |
| Carrier Gas Flow Range & Control | 0–1500 mL/min |
| Carrier Gas Pressure Range & Control | 0–150 psi |
| Injector Maximum Operating Temperature | 450 °C |
| Injector Pressure Setting Range | 0–150 psi |
| Injector Total Flow Setting Range | 0–1500 mL/min |
| Brand | Scion |
|---|---|
| Origin | Netherlands |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported Instrument |
| Model | 8500-GC |
| Instrument Type | Laboratory Gas Chromatograph |
| Application Scope | General-Purpose |
| Oven Temperature Range | Ambient to 450 °C |
| Maximum Ramp Rate | 170 °C/min |
| Maximum Cooling Rate | 150 °C/min |
| Carrier Gas Flow Range & Control | 0–1500 mL/min |
| Carrier Gas Pressure Range & Control | 0–150 psi |
| Injector Maximum Operating Temperature | 450 °C |
| Injector Pressure Setting Range | 0–150 psi |
| Injector Total Flow Setting Range | 0–1500 mL/min |
| Brand | SCION |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Regional Classification | Domestic (China) |
| Model | Primaide / Chromaster |
| Pricing | Available Upon Request |
| Brand | ShangHaiYousufu |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | 12.7 mm OD × 0.89 mm Wall Thickness |
| Tube Material | ASTM A269/A270 Grade 316L Stainless Steel |
| Surface Finish | Bright Annealed (BA) |
| Outer Diameter Tolerance | ±0.02 mm |
| Outer Surface Roughness | Ra ≤ 0.4 µm |
| Compliance Standards | GB/T 12771, ASTM A269, ASTM A270, JIS G3446, DIN 17456 |
| Packaging | Non-woven Fabric Wrapped, Sealed in Plastic Caps |
| Brand | Shimadzu |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | Brevis GC-2050 |
| Instrument Type | Laboratory Gas Chromatograph |
| Application Scope | General-Purpose |
| Oven Temperature Range | Ambient + 4 °C to 450 °C |
| Maximum Ramp Rate | 250 °C/min |
| Carrier Gas Pressure Range & Control | 0–1035 kPa (7 programmable pressure segments) |
| Injector Maximum Operating Temperature | 450 °C |
| Injector Pressure Setting Range | 0–1035 kPa |
| Injector Total Flow Setting Range | 0–1300 mL/min (He or H₂), 0–600 mL/min (N₂) |
| Brand | Shimadzu |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic Instrument |
| Model | G-VAPORIZER |
| Price Range | USD 3,900 – 5,600 (FOB) |
| Instrument Type | Laboratory Gas Chromatograph Accessory |
| Application Field | Petrochemical & Coal Chemical Industries |
| Maximum Operating Temperature | 230 °C |
| Maximum Sample Inlet Pressure | 9 MPa (1305 psi) |
| Heating Zone | Heated Transfer Line with Active Temperature Control |
| Inlet Configuration | Dual-Mode (Gas/Liquid) with Solenoid Valve Integration |
| Communication Interface | GC-System Synchronization via Digital I/O or RS-232 |
| Surface Treatment | Passivated Stainless Steel Tubing |
| Filtration | Integrated Particulate Filter (5 µm) |
| Brand | Shimadzu |
|---|---|
| Origin | Imported |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Model | GC Smart (GC-2018) |
| Application Scope | General-purpose analysis |
| Detector Options | FID, TCD |
| Inlet Options | Packed column inlet, Split/Splitless capillary inlet |
| Maximum Configurable Inlets | 2 |
| Maximum Configurable Detectors | 2 |
| Integrated Autosampler Power Supply | Yes (for AOC-20i) |
| Software | LabSolution LE |
| Connectivity | USB 2.0, Ethernet (10/100BASE-TX) |
| Compliance Support | ASTM D3606, D5504 |
| Brand | Shimadzu |
|---|---|
| Origin | Japan |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | GC-2010 Pro |
| Instrument Type | Laboratory Gas Chromatograph |
| Application Scope | General-Purpose |
| Oven Temperature Range | Ambient + 4 °C to 450 °C |
| Oven Ramp Rate | –250 to +250 °C/min (programmable) |
| Oven Cooling Rate | 450 °C → 50 °C in ≤3.4 min |
| Carrier Gas Flow Control Range | 0–1250 mL/min (7-segment programming) |
| Carrier Gas Pressure Control Range | 0–1035 kPa (7-segment programming) |
| Injector Maximum Operating Temperature | 450 °C |
| Injector Pressure Setting Range | 0–1035 kPa |
| Injector Total Flow Setting Range | 0–1250 mL/min |
| Brand | Shimadzu |
|---|---|
| Origin | Japan |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | GC-2010 |
| Price Range | USD 4,200 – 7,000 (FOB) |
| Instrument Type | Laboratory Gas Chromatograph |
| Origin | Japan |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | GC-2014 |
| Price Range | USD 21,000 – 28,000 |
| Instrument Type | Laboratory Gas Chromatograph |
| Application Scope | General-Purpose |
| Oven Temperature Range | Ambient +10°C to 420°C (–50°C to 420°C with liquid CO₂ cooling) |
| Maximum Ramp Rate | 250°C/min |
| Cooling Rate | 300°C → 50°C in <6 min |
| Carrier Gas Flow Range & Control | 0–1250 mL/min |
| Carrier Gas Pressure Range & Control | 0–1035 kPa |
| Injector Max Operating Temperature | 420°C |
| Injector Pressure Setting Range | 0–1035 kPa |
| Injector Total Flow Setting Range | 0–1250 mL/min |
| Oven Program Segments | Up to 20 (including cooling ramps) |
| Injector Simultaneous Installation | Up to 3 units |
| Detector Simultaneous Installation | Up to 4 units |
| Detector Compatibility | FID, TCD, ECD, FPD, FTD (capillary & packed column variants) |
| Display | 240 × 320-pixel graphical LCD (30 chars × 60 lines) |
| Dimensions (GC Main Unit) | 400 × 690 × 607 mm (W × H × D) |
| Weight | 48 kg (GC-2014AF configuration) |
| Power Supply | AC 200 V, 1800 VA, 50/60 Hz |
| Brand | Shimadzu |
|---|---|
| Origin | Imported (Manufactured in Suzhou, China under Shimadzu Global Quality Standards) |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Instrument Type | Laboratory Gas Chromatograph |
| Application Scope | General-Purpose Analysis |
| Oven Temperature Range | Ambient +10 °C to 400 °C |
| Maximum Ramp Rate | 250 °C/min |
| Cooling Rate | From 300 °C to 50 °C in <6 min |
| Carrier Gas Flow Control Range | 0–1200 mL/min (7 programmable segments) |
| Carrier Gas Pressure Control Range | 0–970 kPa (7 programmable segments) |
| Injector Maximum Operating Temperature | 420 °C |
| Injector Pressure Setting Range | 0–970 kPa |
| Injector Total Flow Setting Range | 0–1200 mL/min |
| Brand | Shimadzu |
|---|---|
| Origin | Japan |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported |
| Model | GC×GC-qMS |
| Price Range | USD 135,000 – 205,000 (FOB Japan) |
| Application Scope | General-Purpose Analytical Laboratory |
| Brand | Shimadzu |
|---|---|
| Origin | Japan |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | MDGC/GCMS |
| Application Scope | General-Purpose Analytical Chemistry |
| Brand | Shimadzu |
|---|---|
| Origin | Japan |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | Micro Methanizer |
| Instrument Type | Laboratory Gas Chromatograph Accessory |
| Application Scope | Universal for Carbon-Containing Compound Analysis |
| Core Configuration | FID-Integrated Catalytic Converter (Jetanizer & Polyarc Reactor Options) |
| Catalyst Chemistry | Nickel-Free for Jetanizer |
| Linear Dynamic Range | ppm to % (CO/CO₂) |
| Installation Time | <5 min (FID nozzle replacement only) |
| Oxygen Tolerance | Up to 21% O₂ in carrier gas stream |
| Sulfur Resistance | Stable operation with ≤100 ppb H₂S |
| Conversion Efficiency | ≥99% for >200 carbon-containing species including aldehydes, carboxylic acids, halocarbons, and heteroatom-containing compounds |
| Regulatory Alignment | Compatible with USP <621>, ASTM D1945, ISO 8573-5, and GLP-compliant data integrity workflows |
| Brand | Shimadzu |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Manufacturer |
| Product Origin | Domestic (China) |
| Model | Nexis GC-2030 Enhanced Edition |
| Price Range | USD 42,000 – 70,000 |
| Instrument Type | Laboratory Gas Chromatograph |
| Application Scope | General-purpose |
| Oven Temperature Range | Ambient +2 °C to 450 °C |
| Maximum Ramp Rate | 250 °C/min |
| Cooling Rate | 450 °C → 50 °C in ≤3.4 min (at 22 °C ambient) |
| Carrier Gas Flow Control Range | 0–1250 mL/min (7 programmable segments) |
| Carrier Gas Pressure Control Range | 0–1035 kPa (7 programmable segments) |
| Injector Maximum Operating Temperature | 450 °C |
| Injector Pressure Setting Range | 0–1035 kPa |
| Total Injector Flow Setting Range | 0–1300 mL/min (He or H₂), 0–600 mL/min (N₂) |
| Key | Brand: Shimadzu |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Instrument Type | Laboratory Gas Chromatograph |
| Application Scope | General-Purpose Analysis |
| Oven Temperature Range | Ambient +2 °C to 450 °C |
| Oven Ramp Rate | 0.01–250 °C/min |
| Oven Cool-Down Time | ~3.4 min (450 °C → 50 °C) |
| Carrier Gas Flow Control | 0–1300 mL/min He |
| Carrier Gas Pressure Control | 0–1035 kPa (7 programmable segments) |
| Injector Max Temp | 450 °C |
| Injector Pressure Setting Range | 0–1035 kPa |
| Injector Total Flow Setting Range | 0–1300 mL/min He |
| Brand | Shimadzu |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | Petrochemical Accessories Kit |
| Instrument Type | Laboratory Gas Chromatograph Accessories |
| Application Field | Petroleum & Petrochemical Industry |
| Key Components | G-VAPORIZER Flash Vaporizer |
| Compliance | Designed for ASTM D1319, D5769, D6730, ISO 6974, and USP <467> residual solvent methods |
| Brand | Techcomp |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Laboratory Gas Chromatograph |
| Application Scope | General-Purpose (Benzene-Series & TVOC Analysis) |
| Oven Temperature Range | 5°C above ambient to 400°C |
| Oven Ramp Rate | 0.1–39°C/min |
| Oven Cooling Rate | 50°C/min |
| Injector Maximum Operating Temperature | 400°C |
| Detector | Photoionization Detector (PID) |
| Benzene LOD | 1 ppb |
| Flow Monitoring | Digital Electronic Pressure & Flow Display |
| Software | TVOC-Specific Reverse-Controlled Workstation with Automated Quantitation & Reporting |
