Gel Imaging System
Filter
Showing 31–45 of 45 results
| Brand | Bio-Rad |
|---|---|
| Origin | USA |
| Model | GS-900 |
| Instrument Type | Standard Gel Imaging System |
| Bit Depth | 16-bit |
| Optical Density Range | 0.0 to 3.4 OD |
| Illumination Source | LED-based scanning (400–750 nm) |
| Imaging Modes | Transmission and Reflectance |
| Scan Area | 29 × 33 cm |
| Effective Resolution | Adjustable, down to 36.3 µm |
| Image Acquisition Platform | Sealed, humidity-tolerant chamber with adjustable transparent lid |
| Software | Image Lab™ v6.x or later (FDA 21 CFR Part 11 compliant configuration available) |
| Brand | CLINX |
|---|---|
| Origin | Shanghai, China |
| Model | ChemiScope 6100 Touch |
| Instrument Type | Chemiluminescence Gel Imaging System |
| CCD Resolution | 6.0 Megapixels |
| Brand | CLINX |
|---|---|
| Origin | Shanghai, China |
| Model | GenoSens S2 |
| Instrument Type | Standard Gel Imaging System |
| CCD Resolution | 6.37 MP (3089 × 2064 pixels) |
| Bit Depth | 16-bit |
| Lens | High-Resolution Fixed-Focal Lens |
| Imaging Area | 16 × 11.5 cm |
| UV Transillumination | 302 nm LED (17 × 13 cm active area) |
| Blue Light Transillumination | 470 nm LED (17 × 13 cm) |
| White Light Reflectance | Integrated LED |
| Filter | Multi-layer 99% UV-blocking emission filter |
| Sample Stage | Motorized adjustable stage with auto-alignment |
| Interface | USB 2.0, Wi-Fi module optional |
| Touchscreen | Embedded 10.1-inch capacitive multi-touch display |
| Dimensions (W×D×H) | 386 × 355 × 321 mm |
| Compliance | CE, RoHS, ISO 13485–compatible design for laboratory use |
| Brand | Cytiva |
|---|---|
| Origin | Japan |
| Model | Amersham ImageQuant 800 |
| Imaging Type | Chemiluminescence Gel Imager |
| CCD Resolution | 8.3 MP |
| Lens | Fujinon F0.74 |
| LED Channels | RGB, NIR-short, NIR-long, UV, Side-reflected white light, Transmitted white light |
| GxP Compliance Module | Optional FDA 21 CFR Part 11 / EU GMP Annex 11 Ready |
| Brand | Cytiva |
|---|---|
| Origin | Japan |
| Model | Amersham ImageQuant 500 |
| Imaging Type | Chemiluminescence |
| CCD Resolution | 8.3 MP |
| Dynamic Range | 4.8 decades |
| Lens Aperture | f/0.14 (Fujifilm) |
| Brand | Cytiva |
|---|---|
| Origin | Japan |
| Model | Amersham Typhoon IP |
| Dynamic Range | >5 decades |
| Scan Area | 40 × 46 cm |
| Imaging Modes | Phosphor Imaging, Fluorescence (RGB), Near-Infrared (NIR), Optical Density (OD) |
| Detector Type | High-Sensitivity PMT-based Scanning System |
| Lens | Fujifilm Precision Optics |
| Compliance | Supports IQ/OQ Documentation, GLP/GMP-Ready Data Acquisition |
| Brand | Cytiva |
|---|---|
| Origin | Japan |
| Model | Amersham Typhoon NIR / NIR+ |
| Instrument Type | Multicolor Fluorescent Gel Imaging System |
| Detection Principle | Confocal Laser Scanning with Dual-NIR Fluorescence Excitation and Emission Filtering |
| Laser Wavelengths | 685 nm, 785 nm |
| Emission Filters | IRshort 720BP20, IRlong 825BP30 |
| Scan Modes | Automatic, Semi-Automatic, Manual |
| Sample Formats | SDS-PAGE gels, agarose gels, nitrocellulose/PVDF membranes, microplates, Petri dishes, glass slides, tissue sections |
| Detector | Enhanced Photomultiplier Tube (PMT) optimized for NIR spectral range |
| Dynamic Range | >4 orders of magnitude (log-linear response) |
| Spatial Resolution | ≤50 µm (pixel size adjustable) |
| Software Platform | ImageQuant TL with GLP-compliant audit trail and 21 CFR Part 11 optional modules |
| Brand | Cytiva |
|---|---|
| Origin | Japan |
| Model | Amersham Typhoon RGB |
| Imaging Modes | Multicolor Fluorescence (RGB), Dual-Channel Near-Infrared (NIR), Phosphor Imaging, Optical Density (OD) |
| Pixel Resolution | Down to 10 µm |
| Scan Area | Up to 40 × 46 cm (Typhoon 5/RGB) |
| Dynamic Range | >5 orders of magnitude |
| Detection Sensitivity | As low as 3 pg protein (fluorescently labeled) |
| Laser Configuration | 5-laser platform (Typhoon 5) |
| Detector Type | High-gain Photomultiplier Tubes (PMTs) |
| Upgrade Path | Field-upgradable across models |
| Brand | DELEITE |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | Geliant-D503 |
| Instrument Type | Standard Gel Imaging System |
| CCD Resolution | 2592 × 1944 (5.03 MP) |
| Bit Depth | 16-bit (65,536 gray levels) |
| Dynamic Range | 65,536 gray levels |
| CCD Sensor Size | 13.48 mm × 10.11 mm |
| Pixel Size | 5.2 µm × 5.2 µm |
| Detection Sensitivity | ≤ 0.02 ng double-stranded DNA (ethidium bromide staining) |
| Signal-to-Noise Ratio | 69.8 dB |
| Lens | Imported 6× motorized zoom lens, f/1.2, focal length 8–48 mm |
| Transmission UV Source | Standard 302 nm (high-efficiency ballast, η > 80%, rated lamp life ≥ 40,000 on/off cycles) |
| Transmission White Light | Adjustable-intensity LED uniform illuminator |
| Transmission Blue Light | Optional 470 nm |
| Reflected UV | Optional 254 nm / 365 nm |
| Reflected White Light | Dual-side high-brightness cold LED |
| UV Transilluminator Area | 210 mm × 260 mm |
| Visible Light Transilluminator Area | 210 mm × 260 mm |
| Integrated Gel Cutting Hood | Standard |
| Control Architecture | Fully programmable microprocessor-controlled module (lens zoom/focus/aperture, transmission/reflection illumination, cutting light) |
| Auto UV Shut-off | Configurable timer (1–60 min inactivity) |
| Enclosure | Light-tight dark chamber with interlocked UV safety cutoff |
| Software | DELEITE GelCapture & GelAnalyzer Suite (free lifetime installation, updates, remote training, and on-site support per contractual agreement) |
| Brand | JiaPeng |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | JP-K3300 |
| Instrument Type | Chemiluminescence Gel Imaging System |
| CCD Resolution | 9 MP (3000 × 3000) |
| Bit Depth | 16-bit |
| Dynamic Range | 4.8 OD (0–65,535 grayscale levels) |
| Pixel Binning Options | 1×1, 2×2, 3×3, 4×4, 6×6, 8×8 |
| Detection Sensitivity | ≥0.02 ng Protein |
| Signal-to-Noise Ratio | 56 dB |
| Lens Aperture | f/0.95 Fixed Focus Lens |
| CCD Sensor | Sony IMX533CLK-D, 4/3″ format |
| Cooling Temperature | −45 °C (ΔT ≈ −65 °C vs. ambient) |
| Quantum Efficiency | >75% |
| Pixel Size | 5.4 µm × 5.4 µm |
| White Light Transilluminator | Uniform top-mounted LED source |
| Dual Imaging Area | 9.5 × 9.5 cm and 12.5 × 12.5 cm |
| Power Supply | AC 220 V, 50/60 Hz |
| Dimensions (W × D × H) | 390 × 440 × 735 mm |
| Weight | 18.3 kg |
| Brand | LY |
|---|---|
| Origin | Beijing, China |
| Model | WD-9413BX |
| Instrument Type | Standard Gel Imaging System |
| CCD Resolution | 1.3 MP (optional 6.4 MP) |
| Bit Depth | 8-bit |
| Detection Sensitivity | >1 pg double-stranded DNA stained with ethidium bromide (EB) |
| Signal-to-Noise Ratio | 62 dB |
| Lens | Professional 6× optical zoom lens |
| UV Transillumination Area | 252 × 252 mm (302 nm) |
| Reflected UV Wavelengths | 254 nm & 365 nm |
| Visible Light Transillumination Area | 260 × 175 mm (white light panel) |
| Camera Pixel Size | 5.2 µm × 5.2 µm |
| Exposure Time Range | 1/100000–1/50 sec |
| Dimensions (W × D × H) | 460 × 420 × 670 mm |
| Brand | LY |
|---|---|
| Origin | Beijing, China |
| Model | WD-9413D |
| Instrument Type | Standard Gel Imaging System |
| CCD Resolution | 5 MP |
| Bit Depth | 16-bit |
| Detection Sensitivity | 20 pg dsDNA stained with ethidium bromide (EB) |
| Optical Lens | Imported 6× motorized zoom lens with electric tri-variable aperture and high-transmission optics (parameters synchronized in software) |
| UV Transillumination Area | 220 × 250 mm (302 nm) |
| Visible Light Transillumination Area | 190 × 270 mm |
| UV Reflectance Wavelengths | 254 nm & 365 nm |
| White Light Reflection | Dual-side high-intensity LED |
| Filter | 590 nm coated bandpass filter for nucleic acid gels |
| Exposure Time Range | 1 ms – 180 s |
| Pixel Binning Options | 1×1, 2×2, 4×4 |
| Frame Rate | 35 fps |
| Image Resolution | 600 DPI (horizontal/vertical) |
| Interface | USB 3.0 |
| Safety Features | UV door interlock shutdown, retractable drawer design with light-tight enclosure |
| Software | Integrated gel acquisition and analysis suite with auto-exposure, image stacking, and background subtraction algorithms |
| Brand | Aplegen |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Instrument Category | Imported |
| Model | Omega Fluor |
| Instrument Type | Standard Gel Imaging System |
| CCD Resolution | 5.0 Megapixel (Physical Pixels) |
| Bit Depth | 12-bit |
| Lens | Fixed F1.4 Lens |
| Dimensions (W×D×H) | 36 × 32 × 64 cm |
| Safety Feature | UV Interlock — Automatic Power Cutoff Upon Chamber Door Opening |
| Compatible Stains | Ethidium Bromide (EB), Silver Stain, Coomassie Blue |
| Brand | Analytik Jena |
|---|---|
| Origin | USA |
| Manufacturer | Analytik Jena |
| Country of Origin | Imported |
| Model | UVP GelSolo |
| Pricing | Available Upon Request |
| Brand | Analytik Jena |
|---|---|
| Origin | USA |
| Manufacturer | UVP (a brand of Analytik Jena) |
| Model | UVP GelStudio PLUS Touch |
| Detection Modes | UV transillumination (302 nm), White light reflection, RGB fluorescence excitation (470/530/630 nm), Optional eLite full-spectrum LED excitation (365–740 nm) |
| Camera | Scientific-grade cooled CCD sensor with 16-bit digitization |
| Lens | Motorized f/1.4 macro lens with auto-focus and zoom |
| Safety | Interlocked UV chamber with automatic lamp shutoff, CE/UL certified |
| Compliance | Meets ISO 9001 manufacturing standards |