Gene Sequencer
Filter
Showing all 15 results
| Brand | Applied Biosystems |
|---|---|
| Origin | USA |
| Model | ABI3130xl |
| Instrument Type | First-Generation Sanger Sequencer |
| Category | Capillary Electrophoresis–Based DNA Sequencing System |
| Regulatory Designation | Import-Class Life Science Instrument |
| Vendor Status | Authorized Refurbishment & Distribution Partner |
| Brand | ALLSHENG |
|---|---|
| Origin | Zhejiang, China |
| Model | Auto-NGS 180S |
| Sample Throughput | 8–24 samples per run (full automation) |
| Pipetting Channels | 24-channel adjustable (1/8/16/24-channel modes) |
| Pipetting Range | 0.5–200 µL |
| Accuracy (A) | ±10% at 0.5 µL, ±2% at 20 µL, ±1% at 100/200 µL |
| Precision (CV) | ≤5% at 0.5 µL, ≤2% at 20 µL, ≤1% at 100/200 µL |
| Minimum Sample Volume for Fluorometric Quantification | 2 µL |
| dsDNA Detection Limit | 0.4 ng |
| Fluorescence Module | 24-well integrated fluorometer, CV ≤1.5% repeatability |
| Thermal Modules | Dual 4–105 °C refrigeration units (±0.5 °C accuracy/uniformity), one heating module (RT–105 °C), one heating-shaking module (RT–105 °C, 200–3000 RPM, 2 mm orbit), one PCR thermal cycler (block: 4–99 °C, lid: 30–120 °C, uniformity ±0.7 °C, accuracy ≤±0.3 °C) |
| Magnetic Bead Purification | 96-well circular magnetic stand (compatible with PCR/deep-well plates) |
| Tip Capacity | Up to 10 tip boxes (6 single-layer + 2 double-layer positions) |
| Brand | Anxuyuan |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | AxiLona AXP-100 |
| Instrument Type | Third-Generation Sequencer |
| Medical Device Classification | Non-Medical Device |
| Form Factor | Benchtop Sequencer |
| Read Length Range | 1–100 kbp |
| Sample Input Requirement | ≥100 ng |
| Throughput | ≤100 Gb per run |
| Base Call Quality | >80% of bases ≥ Q20 |
| Raw Read Accuracy | 99.2% |
| Brand | Applied Biosystems |
|---|---|
| Origin | USA |
| Model | ABI 3500/XL |
| Instrument Type | First-Generation (Sanger) Sequencer |
| Category | Imported |
| Distributor Type | Authorized Third-Party Reseller |
| Brand | Applied Biosystems |
|---|---|
| Origin | USA |
| Model | ABI3100 |
| Instrument Type | First-Generation Capillary Electrophoresis Sequencer |
| Sample Throughput | Up to 768 samples per unattended run (2 × 384-well plates or 4 × 96-well plates) |
| Capillary Array | 16-capillary array |
| Excitation Source | Single 488 nm argon-ion laser |
| Detection | Dual-side illumination with grating-based full-spectrum fluorescence detection using CCD camera |
| Voltage Range | Up to 20 kV |
| Operating Temperature | 18–65 °C |
| Dimensions (W×D×H, door closed) | 74 × 54.8 × 81 cm |
| Weight | 130 kg |
| Power Requirement | 200–240 V AC, 50/60 Hz, ≤15 A, 2000 W |
| Environmental Conditions | 15–35 °C ambient, 20–80% non-condensing humidity |
| Brand | Applied Biosystems |
|---|---|
| Origin | USA |
| Model | ABI3730 |
| Instrument Type | First-Generation Sanger Sequencer |
| Configuration | Refurbished Unit with Full System Validation |
| Compliance | Designed to meet legacy GLP/GMP-relevant operational standards for nucleic acid analysis |
| Brand | Applied Biosystems |
|---|---|
| Origin | USA |
| Model | ABI3730XL |
| Category | Imported Instrument |
| Condition | Refurbished Unit |
| Sample Throughput | 96-capillary array |
| Read Length | Up to 1,000 bases (typical under standard POP-7 polymer and BigDye Terminator v3.1 chemistry) |
| Data Output Format | AB1 (.ab1), SCF, FASTA, QUAL |
| Base Calling Accuracy | ≥99.99% (Q40+ for >80% of bases in high-quality templates) |
| Run Time | ~2.5 hours per 96-well plate (standard sequencing protocol) |
| Detection System | CCD-based fluorescence detection with four-color laser excitation (488 nm, 532 nm, 595 nm, 635 nm) |
| Capillary Array | 96 × 50 cm fused-silica capillaries with polymer matrix (POP-7 or POP-6) |
| Brand | Autobio |
|---|---|
| Model | Sikun1000 |
| Instrument Type | Second-Generation Sequencing Platform |
| Regulatory Status | CE-IVD & NMPA-Certified In Vitro Diagnostic Device |
| Form Factor | Benchtop Sequencer |
| Read Length | 50–300 bp |
| Throughput | 110M–330M Reads per Run |
| Data Output | 5–100 Gb per Run |
| Run Time | 3.5–24 h |
| Base Call Accuracy (Q30) | >85%–90% |
| Optical Detection Method | Fluorescence-Based Sequencing-by-Synthesis on Solid-Phase Amplified Flow Cell |
| Compliance | ISO 13485, IEC 62304, FDA 21 CFR Part 820, GLP/GMP-Aligned Data Integrity Framework |
| Brand | Autobio |
|---|---|
| Model | Sikun2000 |
| Instrument Type | Second-Generation Sequencing Platform |
| Regulatory Status | CE-IVDR and NMPA-Certified In Vitro Diagnostic Device |
| Form Factor | Benchtop Sequencer |
| Read Length Range | 50–300 bp |
| Data Quality | Q30 ≥ 85%–90% |
| Accuracy | >99.9% Base Call Accuracy (per-cycle consensus) |
| Run Time | As fast as 3.2 hours (dependent on read length and chip configuration) |
| Throughput | Mid-Throughput Chip: 220 million reads (11–66 Gb) |
| High-Throughput Chip | 660 million reads (33–200 Gb) |
| Chemistry | Surface-Based Bridge Amplification with Reversible Dye-Terminator Fluorescence Detection |
| Compliance | Designed and validated per ISO 13485, IEC 62304, and aligned with FDA 21 CFR Part 820 and EU IVDR Annex I essential requirements |
| Brand | Autobio |
|---|---|
| Model | Sikun500 |
| Instrument Type | Second-Generation Sequencing Platform |
| Medical Device Classification | Class III (China NMPA) |
| Form Factor | Benchtop Sequencer |
| Read Length | 50–300 bp |
| Q30 Score | >85–90% |
| Sequencing Accuracy | >99.9% |
| Run Time | 3.5–24 hours |
| Throughput | 60M–170M Reads per Run |
| Data Output | 5–50 Gb per Run |
| Origin | Henan, China |
| Regulatory Status | CE-IVD compliant (pending), NMPA registered |
| Brand | MGI |
|---|---|
| Origin | Guangdong, China |
| Model | DNBSEQ-E25 |
| Instrument Type | Short-Read Sequencing Platform |
| Form Factor | Benchtop |
| Read Length Options | Single-End 100 bp (SE100), Rapid SE100 mode |
| Core Technology | DNA Nanoball (DNB) Sequencing with Patterned Flow Cell and Self-Illuminating Chemistry |
| Signal Detection | Integrated On-Chip Photodetector Array |
| Footprint | 0.1 m² |
| Power Consumption | Low-power architecture optimized for decentralized deployment |
| Brand | Illumina |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | NextSeq 550 |
| Instrument Class | Second-Generation (NGS) Sequencer |
| Regulatory Status | FDA-cleared IVD Device (Class II) |
| Form Factor | Benchtop Sequencing Platform |
| Integrated Functionality | NGS + Cytogenomic Microarray Scanning |
| Compliance | CE-IVD, FDA 510(k) cleared (K182913), ISO 13485 certified |
| Brand | MGI |
|---|---|
| Origin | Guangdong, China |
| Instrument Type | Second-Generation Sequencer |
| Platform | DNBSEQ™ Technology |
| Form Factor | Benchtop |
| Regulatory Status | Medical Device |
| Read Lengths | SE100, PE50, PE150, PE300, SE400 |
| Throughput per Run | 8–96 Gb |
| Q30 Score | >85% (PE150) |
| Run Time | 12 h (PE150) |
| Compliance | CE-IVDR, NMPA Class II/III registered (as applicable), supports 21 CFR Part 11-compliant software modules |
| Brand | MGI |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | MGISEQ-T7 |
| Instrument Type | Second-Generation Sequencer |
| Medical Device Classification | Yes (Class II/III per NMPA) |
| Throughput | 1–6 Tb per run |
| Read Lengths | SE50, PE100, PE150 |
| Accuracy | Q30 ≥ 85% (PE100), ≥ 80% (PE150) |
| Run Time | ~20 h (PE100), ~24 h (PE150), ~5 h (SE50) |
| Maximum Effective Reads per Flow Cell | 5,000 M |
| Flow Cells per Run | 1–4 (independently controlled) |
| Data Output per Flow Cell | up to 1.5 Tb |
| Daily Max Output | 6 Tb (4-flow-cell mode) |
| Brand | Thermo Fisher |
|---|---|
| Origin | Japan |
| Manufacturer Type | Manufacturer |
| Origin Category | Imported |
| Model | 3500 Dx / 3500xL Dx |
| Instrument Type | First-Generation (Sanger) Sequencer |
| Throughput | 1104 samples/day |
| Read Length Range | 30–1000 bp |
| Detection Accuracy | 99.99% |
| Detection Reproducibility | 90% |
| Run Time | 1000 reads per 120 min |
| Data Format | Capillary Electrophoresis-Based Sequencing |
| Software | Data Collection Software v3, Sequencing Analysis v6, KB Basecaller v1.4.1, Variant Reporter™, SeqScape®, GeneMapper®, GeneMapper ID-x®, MicroSEQ ID® |