General Meters & Instruments
Filter
Showing 1–30 of 114 results
| Brand | A&D |
|---|---|
| Origin | Japan |
| Model | AD-4404 |
| Sampling Rate | 100 Hz |
| Internal A/D Resolution | 1 part in 1,000,000 |
| Display Resolution | 1/16,000 |
| Input Sensitivity | 0.3 µV/d |
| Zero Tracking | Static & Dynamic with Real-time Compensation |
| Communication Interfaces | Standard RS-485 + Current Loop Output |
| Optional I/O Modules | BCD, Relay, RS-232/422/485, Parallel, Analog Output |
| Brand | A&D |
|---|---|
| Origin | Japan |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | AD-4408A |
| Pricing | Upon Request |
| Brand | A&D |
|---|---|
| Origin | Japan |
| Manufacturer | A&D Co., Ltd. |
| Type | Imported Industrial Weight Indicator |
| Model | AD-4408C |
| Pricing | Upon Request |
| Brand | A&D |
|---|---|
| Origin | Japan |
| Model | AD-4532B |
| Input Impedance Compatibility | <10 kΩ |
| Excitation Voltage Options | 5 V (up to four 350 Ω sensors) or 2.5 V (up to four 120 Ω or eight 350 Ω sensors) |
| Calibration | Digital calibration (sensor sensitivity input) or physical load calibration |
| Zero Adjustment Range | ±50% of full-scale output voltage |
| Span Adjustment Range | ±0.25 mV/V to ±3 mV/V |
| Minimum Input Sensitivity | 0.6 µV/d |
| Minimum Display Resolution | 0.12 µV/d |
| Maximum Display | ±999999 |
| Linearity | 0.02% F.S. (within ±1 digit) |
| A/D Conversion Rate | 2000 samples/sec |
| Zero Temperature Coefficient | ±0.5 µV/°C (typ.) |
| Span Temperature Coefficient | ±30 ppm/°C (typ.) |
| Display | 6-digit, 7-segment LED (14 mm height) |
| Keypad | 6 keys |
| Comparison Output | HI/OK/LO relay contacts (0.1 A, 250 V AC) or MOSFET outputs (0.5 A, 30 V DC) |
| Hold Modes | Sample hold, peak hold, valley hold, bipolar hold |
| Analog Amplified Output | ±10 V (fixed at 3.2 mV/V sensitivity), linearity 0.05% F.S., tempco 100 ppm/°C |
| D/A Output | ±10 V, resolution 1/10000, tempco 100 ppm/°C |
| Communication | Modbus-RTU (RS-485) |
| Power Supply | 85–250 V AC, 50/60 Hz, ~20 W |
| Operating Environment | –5 to +40 °C, ≤85% RH (non-condensing) |
| Dimensions (W×H×D) | 96 × 96 × 155 mm |
| Panel Cutout | 92 × 92 mm |
| Optional Interfaces | BCD (AD-4532B-01), RS-232C (AD-4532B-04), ±10 V / 4–20 mA D/A (AD-4532B-07), Ethernet (AD-4532B-08) |
| Brand | A&D |
|---|---|
| Origin | Japan |
| Model | AD-4401 |
| Sampling Rate | 100 Hz |
| Internal A/D Resolution | 1:1,000,000 |
| Display Resolution | 1:16,000 |
| Input Sensitivity | 0.3 µV/d |
| IP Rating | IP65 |
| Communication Interfaces | RS-232 (current loop & optional voltage), RS-422/485 (up to 10 units daisy-chained), BCD, 4–20 mA analog output |
| Operating Modes | 8 configurable weighing and control modes |
| Brand | A&D |
|---|---|
| Origin | Japan |
| Model | AD-4402 |
| Analog-to-Digital Conversion | 100 Hz sampling rate, internal resolution 1/1,000,000, display resolution 1/16,000, input sensitivity 0.3 µV/d |
| IP Rating | IP65 front panel |
| I/O Capacity | 11 inputs / 11 outputs (configurable across 50 functions) |
| Recipe Storage | 100 recipes |
| Material Database | 100 materials |
| Alarm Outputs | up to 8 fault signals |
| Communication Interfaces | RS-232, RS-422/485, parallel BCD, relay, analog output, CC-Link, DeviceNet, PROFIBUS (via optional interface boards) |
| Calibration | digital span calibration & gravity compensation (no weights required) |
| Brand | ABERLINK |
|---|---|
| Origin | United Kingdom |
| Model | Aberlink-3D |
| Type | PC-based 3D coordinate metrology software for CMMs and optical measuring systems |
| Compliance | ISO 10360, ISO 14253, VDI/VDE 2617, GD&T per ASME Y14.5 & ISO 1101 |
| Licensing | Perpetual license with optional annual support & update subscription |
| Brand | ACL Staticide |
|---|---|
| Origin | USA |
| Model | 780/781 |
| Test Range | 10⁵ – 10⁸ Ω (standard) |
| Accuracy | ±10% |
| Power Supply | 9 V DC battery or AC adapter |
| Operating Environment | 0–38 °C, 15–95% RH |
| Compliance | ESD Association ANSI/ESD S20.20 & STM97.1 |
| Display | Dual-color LED (red/green) with audible tone |
| Test Modes | Simultaneous wrist strap + bilateral footwear |
| Auto-ranging | Yes |
| Certifications | Factory calibration certificate included |
| Brand | ACL Staticide |
|---|---|
| Origin | USA |
| Model | 350 |
| Display | 3.5-digit LCD with polarity indication |
| Battery | 9 V alkaline (included) |
| Measurement Ranges | 1″ (0–20 kV, 100 V resolution) |
| Accuracy | ±10% of reading |
| Operating Temperature | 10–40 °C |
| Humidity Range | ≤80% RH non-condensing |
| Dimensions | 107 mm × 61 mm × 23 mm |
| Weight | 5 oz (142 g) |
| Calibration | NIST-traceable certificate included |
| Warranty | 1 year (voided if case opened) |
| Housing | Conductive antistatic polymer with built-in grounding path |
| Sample Distance Dependency | Explicitly defined per probe-to-surface spacing |
| Compliance | Meets ANSI/ESD S20.20 and IEC 61340-5-1 recommended practices for electrostatic field measurement |
| Brand | ACL Staticide |
|---|---|
| Origin | USA |
| Model | ACL-800 |
| Impedance Range | 10³–10¹² Ω/□ (Surface) / 10³–10¹² Ω (Resistance) |
| Voltage Test Options | 10 V / 100 V |
| Relative Humidity Range | 10–90 %RH |
| Temperature Range | 0–37.8 °C (32–100 °F) |
| Electrodes Included | Two 2.5″ 5-lb RTT/RTG circular electrodes |
| Display | LCD digital |
| Power | 9 V alkaline battery |
| Compliance | ASTM F150, EOS/ESD S4.1, S7.1, S11.11, CECC 000500, UL 817 |
| Weight | 425 g |
| Enclosure | Protective molded plastic case |
| Brand | AKTS |
|---|---|
| Origin | Switzerland |
| Model | SML |
| Category | Industrial Control Software for Food & Pharmaceutical Packaging Compliance Modeling |
| Regulatory Scope | EU Regulation (EU) No 10/2011, Swiss Ordinance on Materials and Articles in Contact with Food, China GB 9685-2016 |
| Core Methodology | Finite Element Analysis (FEA) based on Fick’s Second Law of Diffusion |
| Chemical Database | >14,800 substances (CAS-indexed, including additives, migrants, contaminants, functional ingredients) |
| Compliance Module | Pre-mapped regulatory thresholds per substance across EU, CH, and CN jurisdictions |
| Sensitivity & Fitting Tools | Monte Carlo Simulation (MCS), Arrhenius parameter fitting (Eₐ, A), log-normal distribution support for input uncertainty quantification |
| Multi-layer Support | Unlimited layer stack modeling (polymer films, laminates, coated papers, pipes, trays, labels) |
| Language Interface | English and Simplified Chinese (GB 9685-native substance lookup) |
| Reuse & Cyclic Testing Mode | Built-in simulation protocols for repeated-use articles (e.g., HDPE-Al-PE-Xb drinking water pipes, reusable containers) |
| Brand | Albillia |
|---|---|
| Origin | Switzerland |
| Model | I-Type |
| Memory | 2 GB Flash Card |
| Interface | RS-232 |
| Sampling Interval | 2 seconds to 15 minutes (adjustable) |
| Power Supply | 12 V DC, 7 Ah battery (operational lifetime: several months) |
| Enclosure | Waterproof cast aluminum |
| Optical Configuration | Rotary selector switch |
| Display | None |
| File System | Basic single-file-system architecture (no hierarchical directory support) |
| Remote Connectivity | No GPRS module |
| Compliance | Designed for field-deployed environmental monitoring per ISO 14001-aligned deployment protocols |
| Brand | Albillia |
|---|---|
| Origin | Switzerland |
| Product Form | Liquid Concentrate |
| Concentration | 300 g/L (30% w/w) |
| CAS No. | 518-47-8 |
| EINECS No. | 208-253-3 |
| Color Index | Acid Yellow 73 (CI 45350) |
| Excitation/Emission Maxima | 491 nm / 515 nm |
| Detection Limit | 0.001 mg/L |
| Visual Detection Threshold | 50–100 µg/L |
| Solubility | >500 g/L in water |
| Adsorption | Low |
| Stability | Degrades under UV exposure, acidic conditions (pH < 7), and oxidative microbial activity |
| Interference | Eosin |
| Purity | ≥90% |
| Chloride Content | ≈7% |
| Moisture Content | ≈5% |
| Packaging | 5 L HDPE container |
| Brand | Albillia |
|---|---|
| Origin | Switzerland |
| Product Form | Liquid concentrate (20% w/v) |
| CAS No. | 3520-42-1 |
| EINECS No. | 220-025-2 |
| Detection Limit | 0.01 µg/L |
| Visual Detection Threshold | >500 µg/L |
| Excitation/Emission Maxima | 565 nm / 585 nm |
| Solubility in Water | 50 g/L |
| Adsorption Behavior | Moderate |
| Primary Interferent | Sulforhodamine G |
| Chemical Stability | Susceptible to oxidative degradation |
| Purity | ≥75% (by HPLC) |
| Brand | Albillia |
|---|---|
| Origin | Switzerland |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Tinopal CBS-X |
| Price Range | USD 70 – 280 |
| Brand | Alibillia |
|---|---|
| Origin | Switzerland |
| Model | III |
| Enclosure | Peli™ rugged case |
| Display | Integrated transparent polycarbonate lid with LCD screen |
| Housing material | Polyamide (PA66) electronics enclosure |
| Power | 1–2 replaceable batteries |
| Data interface | USB 2.0 for flash memory card download |
| User controls | Dual tactile push buttons (no rotary knob) |
| IP rating | IP67 (per IEC 60529, tested per EN 60529) |
| Compliance | CE, RoHS, REACH |
| Intended use | Field-deployed environmental monitoring in condensing humidity conditions |
| Brand | Alibillia |
|---|---|
| Origin | Switzerland |
| Model | FL24 |
| Optical Modules | 4 |
| Turbidity Range | 0.02–400 NTU |
| Fluorescein Sodium LOD | 2 × 10⁻¹¹ g/mL (typ.) |
| Minimum Sampling Interval | 4 s |
| Communication Interface | RS232 |
| Operating Current | 8–28 mA |
| ADC Resolution | 24-bit unipolar |
| Cable Length | ≥30 m (1 kg per 10 m) |
| Temperature Accuracy | ±0.1 °C |
| Temperature Resolution | 0.034 °C |
| Dimensions | Ø48 mm × 270 mm |
| Enclosure Material | Stainless Steel |
| IP Rating | IP68 |
| Weight | 2.2 kg |
| Power Supply | TRMC-series logger powered |
| Data Logger Options | TRMC-GGUN (local), TRMC-GGUN-COM (remote) |
| Brand | Alibillia |
|---|---|
| Origin | Switzerland |
| Model | FL24ABS |
| Optical Channels | 4 (excitation–detection pairs) |
| Turbidity Range | 0.02–100 NTU |
| Fluorescein Sodium Detection Limit | 2 × 10⁻¹¹ g/mL |
| Sampling Interval Options | 8 programmable intervals (2 sec to 15 min for FL24 |
| Data Storage Capacity | 2–16 GB microSD card |
| Power Supply | 6–12 V DC |
| Battery | 12–24 Ah rechargeable (standard: 12 Ah LiFePO₄) |
| Current Draw | 1.5 mA (typical, active measurement mode) |
| A/D Resolution | 24-bit |
| Probe Cable Length | ≥30 m (custom lengths available) |
| Probe Weight | 1 kg per 10 m (ABS version: 80 g/m) |
| Probe Housing | Stainless steel (IP68 rated) |
| Integrated Thermistor Accuracy | ±0.01 °C |
| Probe Dimensions | Ø48 mm × 270 mm |
| Maximum Deployment Depth | 270 m (with standard 30 m cable + extension options) |
| Communication Interface | Digital RS-232 via USB-to-serial adapter (included) |
| Operating Environment | Submersible in boreholes ≥2 inches (5.08 cm) diameter |
| Brand | Alibillia |
|---|---|
| Origin | Switzerland |
| Model | II |
| Storage Capacity | 2 GB microSD card |
| Display | 2×16-character LCD |
| Interface | USB 2.0 |
| Operating System | Embedded DOS-compatible firmware |
| Sampling Interval | 2 seconds to 15 minutes (user-selectable via rotary encoder) |
| Housing Material | Waterproof cast aluminum (IP67-rated enclosure) |
| Power Supply | 12 V DC, compatible with 7 Ah lead-acid battery (typical field runtime: 3–4 weeks) |
| Optional Connectivity | GPRS modem module (external) |
| Environmental Requirement | Desiccant-controlled internal humidity (silica gel sachets mandatory) |
| Data Output | MV analog signals and concentration values (e.g., turbidity, conductivity, pH-derived parameters) |
| Brand | All Precision Instrument |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Model | BEST-121 |
| Resistance Range | 1×10⁴ Ω to 1×10¹⁸ Ω |
| Current Range | 2×10⁻⁴ A to 1×10⁻¹⁶ A |
| Test Voltages | DC 10 V / 50 V / 100 V / 250 V / 500 V / 1000 V (selectable) |
| Basic Accuracy | ±1% |
| Display | Digital LCD |
| Dimensions | 285 mm × 245 mm × 120 mm |
| Weight | ~5 kg |
| Power Supply | AC 220 V, 50 Hz, ~5 W |
| Brand | Hefei Kejing |
|---|---|
| Substrate Diameter | 50.8 mm ±1 mm |
| Substrate Orientation | c-plane (0001) ±1.0° |
| Substrate Material | Al₂O₃ (sapphire) |
| Film Thickness | 10–5000 nm |
| Conductivity Type | Semi-insulating |
| Threading Dislocation Density (TDD) | XRD FWHM (0002) < 500 arcsec, XRD FWHM (10–12) < 1500 arcsec |
| Effective Area | >80% |
| Surface Finish | Single-side polished |
| Customization | Available for non-standard orientations and dimensions |
| Packaging | Class 1000 cleanroom environment |
| Brand | Amiscience |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | FluoroQuik |
| Pricing | Available Upon Request |
| Brand | ANSYS (USA) |
|---|---|
| Origin | USA |
| Product Line | Lumerical |
| Type | Multiphysics Photonic Design Automation (PDA) Software Platform |
| Compliance | Supports ASTM E2911, ISO/IEC 17025 traceability workflows, FDA 21 CFR Part 11–ready audit trails (via integrated license server and user activity logging) |
| Deployment | Windows/Linux x64 |
| Licensing | Concurrent floating licenses with centralized FlexNet-based management |
| Brand | ANSYS (USA) |
|---|---|
| Origin | USA |
| Model | Speos |
| Type | Physics-Based Optical Design & Human Vision Simulation Platform |
| Compliance | Supports ISO 15008, ISO 13406-2, SAE J1757-1, ECE R149, ISO 20880, and FDA/USP visual ergonomics guidelines for display and lighting validation |
| Brand | AOE Tech |
|---|---|
| Model | PMIS |
| Center Wavelength | 980 nm |
| Operating Wavelength Range | ±10 nm |
| Isolation (typ.) | 32 dB |
| Isolation at λc, 23 °C | ≥25 dB |
| Insertion Loss (typ., 23 °C) | 0.8 dB |
| Max. Insertion Loss (23 °C) | ≤1.0 dB |
| Extinction Ratio | ≥20 dB |
| Return Loss (Input/Output) | ≥50/50 dB |
| Max. Optical Power Handling | 300 mW |
| Fiber Type | Panda PM Fiber |
| Operating Temperature | −5 to +50 °C |
| Storage Temperature | −20 to +75 °C |
| Package Dimensions (L×W×H) | 118 × 32 × 32 mm |
| Connector Options | FC/APC, FC/UPC, SC/APC, SC/UPC, LC/APC, LC/UPC, or bare fiber |
| Axis Alignment | Fast Axis (F) or Dual-Axis (B) |
| Fiber Coating | 250 µm bare, 900 µm loose tube, or 3000 mm length options |
| Customization | Optional connectorization, polarization axis labeling, and hermetic packaging available |
| Origin | Shanghai, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China-made) |
| Model | ARtrix2021 |
| Pricing | Available Upon Request |
| Brand | ATSEVA |
|---|---|
| Origin | Russia |
| Model | AA-20DD |
| Pulse Duration Range | 20 fs – 6 ps |
| Wavelength Range | 450–3200 nm |
| Input Repetition Rate | >10 Hz |
| Sensitivity | ≥100 mW² |
| Time Resolution | 0.09–1.22 fs |
| Detector Options | Up to 3 interchangeable photodetectors |
| Input Configuration | Free-space and optional fiber-coupled |
| Compliance | Compatible with ISO/IEC 17025-aligned calibration workflows, supports GLP/GMP-relevant traceability via timestamped measurement logs |
| Key | Brand: ATSEVA |
|---|---|
| Origin | Russia |
| Product Type | Faraday Isolator / Rotator |
| Core Material | TGG (Terbium Gallium Garnet) or Terbium-Doped Glass |
| Peak Isolation | >38 dB (up to >60 dB for dual-stage) |
| Transmission | >90% (up to 98%) |
| Spectral Range | 400–1250 nm (model-dependent) |
| Aperture | 2–15 mm (customizable) |
| Damage Threshold | 1 J/cm² @ 10 ns (isolators), 5 J/cm² @ 160 ns (rotators) |
| Compliance | Designed for alignment with ISO 10110 optical surface specifications and RoHS-compliant packaging |
| Software Interface | None (passive, free-space optical component) |
| Mounting | Standard SM1 (1.035"-40) or custom kinematic mounts available |
| Brand | Auniontech |
|---|---|
| Wavelength Range | 1200–1650 nm & 850 nm |
| Attenuation Range | 0–65 dB |
| Accuracy | ±0.15 dB (1200–1650 nm) / ±0.3 dB (850 nm) |
| Repeatability | ±0.015 dB (1200–1650 nm) / ±0.03 dB (850 nm) |
| Insertion Loss | ≤1.5 dB |
| Operating Temperature | 23 °C ±5 °C |
| Mode Options | Absolute Attenuation (including IL) & Relative Attenuation |
| Features | Integrated Optical Shutter, Zero-Attenuation Calibration Function |
| Compliance | Designed for telecom-grade test environments per ITU-T G.691, IEC 61280-2-9, and Telcordia GR-1073-CORE |
| Brand | Auniontech |
|---|---|
| Model | XR-100 |
| Detector Type | Thermoelectrically Cooled Si-PIN or Silicon Drift Detector (SDD) |
| Energy Resolution (5.9 keV ⁵⁵Fe) | 145 eV (Si-PIN), 122 eV (FAST SDD) |
| Active Area | 6–25 mm² |
| Detector Thickness | 500 µm |
| Beryllium Window Thickness | 0.3–1.0 mil (C1/C2 windows available) |
| Integrated Collimator | Yes |
| Package | Hermetically Sealed TO-8 |
| Preamp Architecture | External JFET-based (SDD), Monolithic CMOS/MOSFET (FAST SDD) |