| Brand | ATS |
|---|---|
| Origin | Canada |
| Model | AH-1500 |
| Instrument Type | High-Pressure Cell Disruptor |
| Operating Pressure | 1500 bar (22,500 psi), up to 1800 bar (27,000 psi) |
| Motor Power | 2.2 kW, 380 V / 50 Hz |
| Throughput | 15 L/h |
| Minimum Sample Volume | 25 mL |
| In-Line Cooling System | Integrated, maintains sample temperature < 20 °C |
| Wetted Materials | 316L stainless steel |
| Compliance | CE-certified, GMP-compliant design |
| Particle Size Reduction | < 100 nm |
| Cell Disruption Efficiency | >95% for E. coli, >90% for yeast |
| Weight | 110 kg |
| Brand | ALPHA |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model | DSP-Ex |
| Product Category | Portable Dew Point Meter |
| Measurement Principle | Electrolytic (P2O5 Sensor) |
| Accuracy | ±2 °C dew point |
| Certification | ATEX Ex ia IIC T3/T4 |
| Operating Pressure | Ambient (101.3 kPa ±10%) |
| Dew Point Range | –110 °C to +20 °C |
| Battery Life | >250 hours continuous operation |
| Power Source | Two C-cell alkaline batteries |
| Display Units | °C, °F, ppm(v), ppb(v), ppm(w), g/m³, lb/MMSCF |
| Gas Compatibility | Air, Ar, H₂, SF₆, CO₂, N₂ (custom molecular weight input supported for ppm(w)) |
| Sensor Interchangeability | Fully field-replaceable with traceable calibration |
| Calibration Certificate | UKAS-traceable to NPL and international humidity standards |
| Sampling Interface | Stainless steel quick-connect fitting + integrated desiccant drying chamber |
| Accessories Included | 2 m PTFE-braided stainless steel sampling hose, anti-static carry case, user manual, factory calibration certificate |
| Brand | ANDES |
|---|---|
| Origin | Japan |
| Model | BF-H201AC |
| Disinfection Principle | UV-activated Titanium Dioxide (Anatase-phase, Columnar Crystal Structure) Photocatalysis |
| Airflow | 3.3 m³/min (Cross-flow Fan, 50/60 Hz) |
| Noise Level | ≤48 dB(A) at 1 m |
| Power Consumption | 93 W |
| Dimensions (W×H×D) | 617 × 510 × 152 mm |
| Application Scope | Medical Facilities, Laboratories, Cleanrooms, Pharmaceutical QA/QC Areas, Food Processing Environments |
| Regulatory Status | Compliant with China NMPA (ex-SFDA) Class II Medical Device Requirements for Air Disinfection Devices |
| Sterilization Mode | Non-thermal, Oxidative Decomposition (No Ozone Generation) |
| Filtration Stages | Pre-filter + UV-activated Columnar TiO₂ Photocatalytic Panel + Negative Ion Emission Module |
| Maintenance Interval | Photocatalytic Panel & UV Lamp: ~12 months under continuous operation in ISO Class 8 (100,000) clean air environments |
| Brand | SLEE |
|---|---|
| Origin | Germany |
| Model | CUT 6062 |
| Instrument Type | Paraffin Microtome |
| Automation Level | Fully Automatic Cryo-Paraffin Microtome |
| Section Thickness Range | 0.5–100 µm (adjustable in 0.5 µm increments) |
| Cutting Speed | User-Configurable |
| Maximum Specimen Size | 50 × 50 mm |
| Dimensions (W × D × H) | 480 × 610 × 350 mm |
| Weight | 34 kg |
| Compliance | CE, ISO 13485 (Medical Device Quality Management), IEC 61010-1 (Laboratory Equipment Safety) |