Add to compare
BrandATS
OriginCanada
ModelAH-1500
Instrument TypeHigh-Pressure Cell Disruptor
Operating Pressure1500 bar (22,500 psi), up to 1800 bar (27,000 psi)
Motor Power2.2 kW, 380 V / 50 Hz
Throughput15 L/h
Minimum Sample Volume25 mL
In-Line Cooling SystemIntegrated, maintains sample temperature < 20 °C
Wetted Materials316L stainless steel
ComplianceCE-certified, GMP-compliant design
Particle Size Reduction< 100 nm
Cell Disruption Efficiency>95% for E. coli, >90% for yeast
Weight110 kg
Added to wishlistRemoved from wishlist 0
Add to compare
BrandALPHA
OriginUnited Kingdom
Manufacturer TypeAuthorized Distributor
Product OriginImported
ModelDSP-Ex
Product CategoryPortable Dew Point Meter
Measurement PrincipleElectrolytic (P2O5 Sensor)
Accuracy±2 °C dew point
CertificationATEX Ex ia IIC T3/T4
Operating PressureAmbient (101.3 kPa ±10%)
Dew Point Range–110 °C to +20 °C
Battery Life>250 hours continuous operation
Power SourceTwo C-cell alkaline batteries
Display Units°C, °F, ppm(v), ppb(v), ppm(w), g/m³, lb/MMSCF
Gas CompatibilityAir, Ar, H₂, SF₆, CO₂, N₂ (custom molecular weight input supported for ppm(w))
Sensor InterchangeabilityFully field-replaceable with traceable calibration
Calibration CertificateUKAS-traceable to NPL and international humidity standards
Sampling InterfaceStainless steel quick-connect fitting + integrated desiccant drying chamber
Accessories Included2 m PTFE-braided stainless steel sampling hose, anti-static carry case, user manual, factory calibration certificate
Added to wishlistRemoved from wishlist 0
Add to compare
BrandANDES
OriginJapan
ModelBF-H201AC
Disinfection PrincipleUV-activated Titanium Dioxide (Anatase-phase, Columnar Crystal Structure) Photocatalysis
Airflow3.3 m³/min (Cross-flow Fan, 50/60 Hz)
Noise Level≤48 dB(A) at 1 m
Power Consumption93 W
Dimensions (W×H×D)617 × 510 × 152 mm
Application ScopeMedical Facilities, Laboratories, Cleanrooms, Pharmaceutical QA/QC Areas, Food Processing Environments
Regulatory StatusCompliant with China NMPA (ex-SFDA) Class II Medical Device Requirements for Air Disinfection Devices
Sterilization ModeNon-thermal, Oxidative Decomposition (No Ozone Generation)
Filtration StagesPre-filter + UV-activated Columnar TiO₂ Photocatalytic Panel + Negative Ion Emission Module
Maintenance IntervalPhotocatalytic Panel & UV Lamp: ~12 months under continuous operation in ISO Class 8 (100,000) clean air environments
Added to wishlistRemoved from wishlist 0
Add to compare
BrandSLEE
OriginGermany
ModelCUT 6062
Instrument TypeParaffin Microtome
Automation LevelFully Automatic Cryo-Paraffin Microtome
Section Thickness Range0.5–100 µm (adjustable in 0.5 µm increments)
Cutting SpeedUser-Configurable
Maximum Specimen Size50 × 50 mm
Dimensions (W × D × H)480 × 610 × 350 mm
Weight34 kg
ComplianceCE, ISO 13485 (Medical Device Quality Management), IEC 61010-1 (Laboratory Equipment Safety)