- All
- Favorite
- Popular
- Most rated
| Brand | APV |
|---|---|
| Origin | Germany |
| Model | APV-2000 |
| Instrument Type | High-Pressure Homogenizer |
| Dimensions (W×D×H) | 370 × 620 × 818 mm |
| Processing Capacity | 11 L/h |
| Fluid End Materials | Duplex Stainless Steel Compression Head, Ceramic Plunger, Cobalt Alloy PVB Valves with Tungsten Carbide Seats |
| Control Interface | Digital Pressure & Temperature Display, Overpressure Alarm, Emergency Stop, Integrated Current-Limiting Safety Circuit |
| Housing | Polished Stainless Steel, CIP/SIP-Compatible, Modular Frame Design |
| Brand | ALISN |
|---|---|
| Model | THA760 |
| Chamber Type | Upright |
| Cooling Method | Air-Cooled |
| Temperature Range | −10 °C to 85 °C |
| Humidity Range | 15–98 % RH |
| Temperature Uniformity (at 15–45 °C) | ±0.3 °C |
| Temperature Fluctuation | ±0.3 °C |
| Humidity Uniformity | ±1.5 % RH |
| Humidity Fluctuation | ±1.5 % RH |
| Heating/cooling Rate | 1.0–3.0 °C/min |
| Internal Dimensions (W×H×D) | 1200 × 1180 × 540 mm |
| Internal Volume | 760 L |
| Refrigerant | R404a |
| Compressor | SECOP (Danfoss Group) |
| Humidity Sensor | E+E Elektronik capacitive sensor |
| Insulation | Monolithic polyurethane foam (≥100 mm thickness) |
| Control System | PID + fuzzy logic algorithm |
| Display | 7-inch full-color TFT touchscreen |
| Data Logging | 3-year storage (1-min interval), USB export, write-protected |
| Audit Trail | 16,000 entries (user actions & alarms), non-modifiable, USB-exportable |
| User Management | 5 configurable roles with granular permissions |
| Communication Ports | RS232, RS485, USB host/device |
| Compliance Support | ASTM E145, ISO 17025, ICH Q1, USP <1151>, FDA 21 CFR Part 11 (audit trail & electronic signature ready) |
| Brand | LUM |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | LUMiSizer |
| Price Range | USD 92,000 – 131,500 (converted at ~¥7.6/USD) |
| Sample Capacity | 12 positions |
| Temperature Control | 4 °C to 60 °C (±1 K) |
| Acceleration Range | 6×g to 2300×g |
| Particle Size Range (by STEP-Technology) | 20 nm – 100 μm (stability & sedimentation velocity) |
| Concentration Range | 0.00015 wt% – 90 wt% |
| Density Range | up to 22 g/cm³ |
| Viscosity Range | 0.8 – 10⁸ mPa·s |
| Optical System | Multi-wavelength transmission scanning (650 nm, optional 470 nm & 870 nm) |
| Measurement Principle | Spatial and temporal extinction profiling (STEP-Technology) |
| Compliance | ISO/TR 13097, ISO 13318-2, FDA 21 CFR Part 11 (software audit trail enabled), GLP-ready |
| Sample Volume | 0.05 mL – 2.0 mL |
| Dimensions (W×H×D) | 37 cm × 27 cm × 60 cm |
| Weight | 40 kg |
| Power Supply | 100–240 V AC, 50/60 Hz |
Show next