Heavy Metals Detector for Water Quality
Filter
Showing 1–30 of 39 results
| Brand | AND/A&D |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported Instrument |
| Model | AND1000 |
| Instrument Type | Portable |
| Detection Principle | Fluorescence-based Photometric Assay |
| Target Analyte | Lead (Pb) |
| Analysis Time | < 60 seconds |
| Detection Limit | 2 ppb |
| Quantification Range | 2–100 ppb |
| Origin | Canada |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Models | AVVOR 8000, AVVOR 9000, HM1000 |
| Pricing | Available Upon Request |
| Brand | AVVOR |
|---|---|
| Origin | Canada |
| Instrument Type | Portable (8000) & Online Continuous Analyzer (9000) |
| Detection Principle | Anodic Stripping Voltammetry (ASV) |
| Detectable Elements | Cu, Cd, Pb, Zn, Ni, As, Hg, Cr (total & Cr⁶⁺), Fe, Mn, Sb, Tl, Se, Co, Mo, Ag, Au, Pd, Sn, U |
| Measurement Time | ≤30 min per sample (8000) |
| Accuracy | ±0.5% of reading |
| Resolution | 0.5 ppt (ng/L) for key elements |
| Compliance | US EPA Methods 7063, 7472, 1001 |
| Brand | AVVOR |
|---|---|
| Origin | Fujian, China |
| Model | AVVOR 8000 HM-1 |
| Instrument Type | Portable |
| Detection Principle | Anodic Stripping Voltammetry (ASV) |
| Detectable Metals | As(III), Total As, Cd, Cu, Pb, Hg, Mn, Ni, Zn |
| Detection Time | < 300 s per metal |
| Accuracy | ±5% RSD (at 10× LOD) |
| Resolution | 0.1 ppb (for Cd, Pb, Cu in aqueous matrix) |
| IP Rating | IP67 |
| Data Storage | 1000 measurement records |
| Power Options | Rechargeable Li-ion battery, AC adapter, 12 V DC car socket |
| Interface | USB 2.0 |
| Display | Backlit LCD with joystick navigation |
| Electrode System | Triple-electrode immersed probe (WE/RE/AE), integrated stirrer and Pt100 temperature sensor |
| Expandability | Up to 3 interchangeable working electrodes in single probe housing |
| Software | Windows-based ASV Analysis Suite with audit trail, calibration history, and report export (PDF/CSV/XLSX) |
| Origin | Canada |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | AVVOR 8000 HM-1 |
| Price | Upon Request |
| Brand | AVVOR |
|---|---|
| Origin | Canada |
| Model | 8000 HM-2 |
| Instrument Type | Portable |
| Detection Principle | Anodic Stripping Voltammetry (ASV) |
| Target Analytes | Hg, Cd, Pb, Cu, Zn, Ni, Cr(VI), As, Mn, Fe, Al, B |
| Detection Time | ≤30 min per sample |
| Accuracy | ±0.5% of reading |
| Resolution | 0.5 ppb (for Hg) |
| IP Rating | IP68 |
| Power Options | Rechargeable Li-ion battery / AC adapter / 12 V DC (cigarette lighter socket) |
| Data Storage | Internal timestamped logging |
| Display | Backlit LCD with touch keypad |
| Connectivity | USB for PC data upload |
| Language Support | Multilingual (English, French, Spanish, German, Chinese) |
| Brand | AVVOR |
|---|---|
| Origin | Canada |
| Model | AVVOR 8000 HM-2 |
| Detection Principle | Anodic Stripping Voltammetry (ASV) |
| Instrument Type | Portable |
| Measurable Elements | Al, As, B, Cd, Cr(VI), Cu, Fe, Hg, Mn, Ni, Pb, Zn |
| Detection Range | ppb to ppm |
| Ingress Protection | IP68 |
| Power Options | Rechargeable battery / AC adapter / Vehicle cigarette lighter socket |
| Data Logging | Time-stamped internal memory |
| Display | Backlit LCD with touch keypad |
| Connectivity | USB for PC data upload |
| Included Accessories | Sample analysis cups, photometric cuvettes, full set of calibration buffers and reagents for 12 metals |
| Language Support | Multilingual interface |
| Electrode System | Triple-electrode immersed probe (working, reference, auxiliary), integrated stirrer and temperature sensor, modular plug-in working electrodes (up to 3 simultaneously) |
| Brand | AVVOR |
|---|---|
| Origin | Canada |
| Model | AVVOR 8000 HM-2 |
| Instrument Type | Portable |
| Detection Principle | Anodic Stripping Voltammetry (ASV) |
| Target Analytes | Al, As, B, Cd, Cr(VI), Cu, Fe, Hg, Mn, Ni, Pb, Zn (12 metals) |
| Detection Range | ppb to ppm |
| Accuracy | ±7.5% |
| Compliance | IP68-rated enclosure |
| Power Options | Rechargeable battery / AC adapter / Vehicle cigarette lighter socket |
| Data Logging | Internal timestamped storage with LCD backlight display |
| Interface | Touch keypad, USB for data export |
| Sample Preparation | Minimal—buffer addition and direct water sampling |
| Analysis Time | Rapid (typically < 5 min per metal, multi-parameter in sequence) |
| Electrode System | Triple-electrode immersed probe with integrated stirrer and temperature sensor |
| Expandability | Up to three working electrodes in one probe housing |
| Software | On-device guided workflow with step-by-step visual prompts |
| Language Support | Multilingual UI |
| Brand | AVVOR |
|---|---|
| Origin | Fujian, China |
| Model | AVVOR 8000 HM-2 |
| Instrument Type | Portable |
| Detection Principle | Anodic Stripping Voltammetry (ASV) |
| Detection Time | 11 minutes per sample |
| Accuracy | ±1% RSD |
| Resolution | 1 ppb (for most target metals) |
| Detectable Elements | Al, As, B, Cd, Cr(VI), Cu, Fe, Hg, Mn, Ni, Pb, Zn |
| Compliance | IP68-rated enclosure |
| Power Options | Rechargeable Li-ion battery / AC adapter / 12V DC car socket |
| Data Logging | Internal timestamped storage |
| Display | Backlit LCD with touch keypad |
| Connectivity | USB and optional Bluetooth for PC data upload |
| Accessories Included | Sample cups, photometric cuvettes, full set of calibration buffers and ASV reagents |
| Language Support | Multilingual UI (English, Spanish, French, German, Chinese) |
| Brand | AVVOR |
|---|---|
| Origin | Canada |
| Model | AVVOR 8000 HM-3 |
| Detection Principle | Anodic Stripping Voltammetry (ASV) |
| IP Rating | IP67 |
| Power Options | Rechargeable Battery / AC Adapter / Vehicle Cigarette Lighter Socket |
| Operating Time | Up to 6 h (hot-swappable battery) |
| Connectivity | Wi-Fi, GSM Mobile Internet |
| Electrode Configuration | Triple-electrode system (working, counter, reference) + integrated temperature sensor + built-in micro-stirrer |
| Supported Parameters | As(III), Total As, Bi, Cd, Cr, Co, Cu, Au, Fe, Pb, Mn, Hg, Ni, Sn, Zn |
| Detection Limit | Down to 1 ppb (matrix-dependent) |
| Data Handling | On-device AVVOR software for real-time calibration, peak integration (manual/automatic), regression analysis, correlation coefficient calculation, and direct sample concentration derivation |
| Compliance | Designed for field-deployable compliance with EPA Method 200.8, ISO 11969, and ASTM D3559 (adapted for portable ASV platforms) |
| Brand | AVVOR |
|---|---|
| Model | AVVOR 8000 HM-3 |
| Detection Principle | Anodic Stripping Voltammetry (ASV) |
| Detection Time | ≤1 min per metal |
| Detection Limit | ≤1 ppb (for Pb, Cd, Cu, Zn, As, Hg) |
| Accuracy | ±5% of reading (at 10 ppb level) |
| Resolution | 0.1 ppb |
| Portability | IP67-rated ruggedized field instrument |
| Power Options | Rechargeable Li-ion battery (6 h operation), AC adapter, 12 V DC (cigarette lighter socket) |
| Connectivity | Wi-Fi, GSM/4G LTE, USB, Bluetooth |
| Electrode Configuration | 5 interchangeable sensor modules with integrated temperature probe and magnetic stirrer |
| Software | AVVOR ASV Suite v3.2 (compliant with FDA 21 CFR Part 11 audit trail & electronic signature support) |
| Compliance | Meets ASTM D3559, ISO 8692, USP <232>/<233>, and EPA Method 7000B requirements for trace metal analysis in aqueous matrices |
| Origin | UK |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | AVVOR 8000 HM-3 |
| Pricing | Upon Request |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | AVVOR 8000 |
| Pricing | Available Upon Request |
| Brand | AVVOR |
|---|---|
| Origin | Canada |
| Model | AVVOR 8000 |
| Detection Principle | Anodic Stripping Voltammetry (ASV) and Spectrophotometry |
| Detection Range | Sub-ppb to ppm levels (e.g., As(III): 0.1–100 µg/L, Cd: 0.05–50 µg/L, Pb: 0.05–50 µg/L, Hg: 0.02–25 µg/L, Cu: 0.1–100 µg/L, Zn: 0.5–200 µg/L) |
| Supported Analytes | As(III), Total As, Cd, Cr(VI), Cu, Pb, Mn, Hg, Ni, Zn, Co, Se |
| Compliance | ASTM D3559, ISO 11969, US EPA Method 7000B (ASV), ISO 6603 (spectrophotometric metal chelation) |
| Data Management | Onboard tablet with GLP-compliant audit trail, CFR Part 11–ready export, Wi-Fi/Bluetooth connectivity |
| IP Rating | IP67 (instrument housing and integrated tablet) |
| Power | Rechargeable Li-ion battery (≥12 h continuous operation) |
| Origin | Canada |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported Instrument |
| Model | AVVOR 9000 |
| Pricing | Available Upon Request |
| Brand | AVVOR |
|---|---|
| Origin | Canada |
| Model | AVVOR 9000 |
| Detection Principle | Anodic Stripping Voltammetry (ASV) |
| Detectable Metals | As, Hg, Se, Zn, Cd, Pb, Cu, Mn, Sb, Tl, Fe, Ni, Sn, Cr, Cr(VI), Co, Mo, Au, Ag, Pd, U |
| Configuration | Dual-module support (up to 5 simultaneous metals per module) |
| Output Interfaces | 8 × 4–20 mA analog outputs, RS-485 & RS-232 digital interfaces |
| Compliance | Designed for continuous unattended operation in industrial effluent, municipal wastewater, surface water, groundwater, drinking water and seawater applications |
| Brand | AVVOR |
|---|---|
| Origin | Canada |
| Model | AVVOR 9000 |
| Detection Principle | Anodic Stripping Voltammetry (ASV) |
| Measurable Elements | Cu, Pb, Zn, Cd, Mn, Sb, Tl, Fe, Ni, As, Hg, Se, Co, Mo, Au, Ag, Cr, Cr(VI), Sn, Pd, U |
| Electrode Options | Gold, Mercury-film, Bismuth-film, Bare Carbon |
| Max. Simultaneous Channels | 2 modules × 5 elements each |
| Output Interfaces | 8 × 4–20 mA analog outputs, RS-485, RS-232 |
| Compliance | Designed for ASTM D3559, ISO 11929, USP <232>/<233>, EPA Method 7000B & 7473 |
| Environmental Certification | IP65 enclosure, NEMA 4X-rated housing |
| Brand | AVVOR |
|---|---|
| Origin | Canada |
| Model | AVVOR 9000 |
| Detection Principle | Anodic Stripping Voltammetry (ASV) |
| Measurable Elements | Cu, Pb, Zn, Cd, Mn, Sb, Tl, Fe, Ni, As, Hg, Se, Co, Mo, Au, Ag, Cr, Cr(VI), Sn, Pd, U |
| Electrode Options | Gold, Mercury-film, Bismuth-film, Bare Carbon |
| Max Modules | 2 |
| Max Simultaneous Parameters per Module | 5 |
| Analog Outputs | 8 × 4–20 mA |
| Digital Interfaces | RS-485, RS-232 |
| Compliance | Designed for ASTM D3559, ISO 11885, EPA Method 7063, and USP <232>/<233> guidance |
| Environmental Rating | IP65 Enclosure with Humidity Control |
| Power Supply | 100–240 VAC, 50/60 Hz |
| Brand | AVVOR |
|---|---|
| Origin | Canada |
| Model | AVVOR 9000 |
| Detection Principle | Anodic Stripping Voltammetry (ASV) |
| Measurable Elements | Cu, Pb, Zn, Cd, Mn, Sb, Tl, Fe, Ni, As, Hg, Se, Co, Mo, Au, Ag, Cr, Cr(VI), Sn, Pd, U |
| Electrode Options | Gold, Mercury-Film, Bismuth-Film, Bare Carbon |
| Max Simultaneous Channels | 2 modules × 5 elements each |
| Output Interfaces | 8 × 4–20 mA analog outputs, RS-485, RS-232 |
| Compliance Support | Designed for ASTM D3559, ISO 11929 (uncertainty evaluation), USP <232>/<233>, EPA Method 7000B (ASV-based), GLP/GMP-ready data logging |
| Brand | -- |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China-made) |
| Model | CU-502 |
| Pricing | Available Upon Request |
| Measurement Principle | AC-modulated Absorption Photometry (Dual-beam Reference LED Architecture) |
| Target Analyte | Cu²⁺ in Acidic Sulfate Electrolytes |
| Measuring Range (Cu) | 0–20 g/L, 0–50 g/L, 0–80 g/L (user-selectable) |
| Measuring Range (CuSO₄) | 0–100 g/L, 0–200 g/L, 0–300 g/L (correlated) |
| Resolution | 0.1 g/L (Cu), 1 g/L (CuSO₄) |
| Repeatability | ±2% FS |
| Response Time | ≤5 s (t₉₀) |
| Operating Temperature | −5 °C to +40 °C |
| Relative Humidity | ≤85% RH (non-condensing) |
| Power Supply | AC 85–240 V, 50/60 Hz |
| Output Signal | Isolated 4–20 mA DC (HART-compatible loop) |
| Enclosure | IP65-rated front panel, DIN 96×96 mm cutout |
| Dimensions (H×W×D) | 96 × 96 × 163 mm |
| Weight | ~1.3 kg |
| Brand | WaterDoctor |
|---|---|
| Origin | Hunan, China |
| Model | Dr-T8100 |
| Instrument Type | Benchtop Laboratory Spectrophotometer |
| Detection Elements | Chromium (Cr) |
| Detection Time | 10 min per sample |
| Accuracy | ≤ ±5% |
| Absorbance Resolution | 0.001 Abs |
| Wavelength Range | 190–1100 nm |
| Wavelength Accuracy | ±1 nm |
| Wavelength Repeatability | < 0.2 nm |
| Spectral Bandwidth | 2 nm |
| Transmittance Error | ±0.5% |
| Transmittance Repeatability | ≤ 0.2% T |
| Absorbance Repeatability | ≤ ±2% |
| Optical System | Dual-beam with Grating Monochromator |
| Light Sources | Imported Deuterium Lamp (UV), Imported Tungsten-Halogen Lamp (Vis) |
| Display | 7-inch HD capacitive touchscreen |
| Sample Holders | Dual independent positions — cylindrical cuvette (360° rotational alignment) and rectangular quartz/glass cuvette |
| Preloaded Calibration Curves | 1200 built-in methods |
| Data Storage | 1,000,000 measurement records |
| Interface | USB port for data export |
| Software Language | Chinese UI standard |
| Brand | DoctorWater |
|---|---|
| Origin | Hunan, China |
| Model | Dr-W110 |
| Instrument Type | Portable |
| Detection Principle | Photometric (Colorimetric) Method |
| Target Analyte | Chromium (Cr) |
| Detection Time | 10 min |
| Wavelength Range | 330–900 nm |
| Wavelength Accuracy | ±5 nm |
| Photometric Resolution | 0.001 Abs |
| Photometric Stability | ≤±0.005 Abs/20 min |
| Repeatability | ≤±2% |
| Accuracy | ≤±5% |
| Sample Format | 16 mm & 25 mm Cuvettes |
| Light Source | Imported Cold LED (Lifespan >100,000 h) |
| Display | 5-inch HD Color Touchscreen |
| Power Supply | Rechargeable Li-ion Battery + AC Adapter |
| Data Storage | Up to 1,000,000 Records |
| Connectivity | USB Type-C (Charging & Data Transfer) |
| Calibration Modes | Blank, Factor, and Calibration Curve |
| Readout Units | Absorbance & Concentration |
| Housing Material | Corrosion-Resistant ABS |
| Compliance | Designed in accordance with GB/T 5750 (China Standard Methods for Examination of Drinking Water) |
| Brand | DoctorWater |
|---|---|
| Origin | Hunan, China |
| Model | Dr-W510 |
| Instrument Type | Benchtop Laboratory Analyzer |
| Detection Principle | Photometric (Absorption Spectrophotometry) |
| Detectable Metals | Multi-parameter (e.g., Pb, Cd, Cr, Cu, Zn, Ni, As, Hg via compatible reagent kits) |
| Analysis Time | ≤10 minutes per sample |
| Accuracy | ≤±5% |
| Repeatability | ≤±2% |
| Wavelength Range | 330–900 nm |
| Wavelength Accuracy | ±5 nm |
| Absorbance Resolution | 0.001 Abs |
| Optical Stability | ≤±0.005 Abs / 20 min |
| Display | 8-inch HD color capacitive touchscreen |
| Language Support | English & Chinese |
| Sample Holders | Dual-position — 360° rotatable cuvette holder & standard 25 mm round cuvette slot |
| Light Source | Imported long-life cold LED (≥100,000 h) |
| Calibration Modes | Blank, Factor, and Calibration Curve |
| Data Storage | Up to 1,000,000 measurement records |
| Connectivity | USB interface |
| Output Modes | Concentration (mg/L, µg/L) or Absorbance (Abs) |
| Printer | Built-in thermal printer |
| Housing Material | Corrosion- and heat-resistant ABS |
| Dimensions (W×D×H) | 392 × 315 × 170 mm |
| Brand | ERUN |
|---|---|
| Origin | Shaanxi, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | ERUN-SP7-18 |
| Instrument Type | Portable |
| Detection Principle | Photometric (Colorimetric) Method |
| Detectable Metals | Cu, Zn, Cr(VI), Pb, Hg, Ni, Fe, Mn, Al, Cd, As, Ag, Mo, Be, B, Sb, Ba |
| Analysis Time | ≤3 min per parameter |
| Accuracy | ±5% of Full Scale (F.S.) |
| Resolution | 0.1 mg/L (for most parameters) |
| Repeatability | ≤3% RSD |
| Optical Stability | Drift < 0.002 A in 20 min |
| Display | 5.0-inch TFT LCD |
| Data Storage | 100 calibration curves + 1999 tagged measurement records (with timestamp & parameter ID) |
| Power Supply | Internal rechargeable Li-ion battery + AC adapter (dual-power system) |
| Dimensions | 410 × 300 × 130 mm |
| Weight | 4.0 kg |
| Power Consumption | <10 W |
| Output | Built-in thermal printer |
| Connectivity | USB port |
| Measurement Modes | Concentration, Absorbance, Transmittance |
| Brand | EXPEC |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | SUPEC 6010 |
| Quotation | Upon Request |
| Instrument Type | Online Analyzer |
| Detection Principle | Inductively Coupled Plasma Optical Emission Spectrometry (ICP-OES) |
| Target Elements | Multi-Element (e.g., As, Cd, Cr, Cu, Ni, Pb, Zn, Hg, Mn, Fe, Al, etc.) |
| Compliance Standard | HJ 776–2015 “Determination of 32 Elements in Water by ICP-OES” |
| Automation Level | Fully Automated (Sampling, Filtration, Pre-treatment, Analysis, QC, Data Acquisition & Transmission) |
| Detection Range | Sub-ppb to ppm (full dynamic range) |
| Measurement Cycle | < 5 minutes per sample (multi-element simultaneous analysis) |
| Interference Resistance | Immune to color, turbidity, and matrix-induced spectral overlap under optimized plasma conditions |
| Waste Generation | Minimal reagent consumption |
| Brand | FPI |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer | FPI (Original Equipment Manufacturer) |
| Model | HMA-2000 Series |
| Instrument Type | Online Analyzer |
| Detection Principle | Anodic Stripping Voltammetry (ASV) |
| Target Metals | Lead (Pb), Cadmium (Cd) |
| Detection Time | Zero Drift (24 h): ±5% F.S. |
| Resolution | 0.0001 mg/L |
| Sample Throughput | Continuous online operation with programmable measurement intervals |
| Reagent Consumption | <20% of conventional flow-injection ASV systems |
| Digestion | Sealed high-temperature high-pressure digestion module (up to 180 °C, 2 MPa) |
| Compliance | Designed for ISO 17294-2, EPA Method 200.8, and ASTM D3559–22 compatibility |
| Brand | FPI |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Country of Origin | China |
| Model | HMA-2000 |
| Instrument Type | Online Analytical System |
| Detection Principle | Anodic Stripping Voltammetry (ASV) |
| Target Metals | Pb, Cd, As, or Hg (configurable per unit) |
| Zero Drift | ±5% F.S. |
| Accuracy/Precision | ±10% |
| Resolution | 0.0001 mg/L |
| Brand | Hach |
|---|---|
| Origin | Imported |
| Manufacturer Type | Manufacturer |
| Model | Hach EZ Series (EZ1000 for Dissolved Metals / EZ2000 for Total Metals) |
| Instrument Type | Online Analyzer |
| Detection Principle | Colorimetric Spectrophotometry (not ICP-OES — correction applied per technical accuracy) |
| Target Metals | Cu, Fe, Ni, Mn, Cr, Zn (Dissolved and/or Total forms) |
| Accuracy/Precision | ≤2% F.S. (with certified standard solutions) |
| Resolution | As specified in individual parameter datasheets |
| Sample Throughput | Up to 8-channel sequential analysis |
| Onboard Digestion | Integrated UV/persulfate digestion module (EZ2000 series only) |
| Output | 4–20 mA analog output with alarm thresholds |
| Communication | Modbus TCP/IP via Ethernet |
| Sample Volume per Analysis | <15 mL |
| Optical Path Length | Extended (≥50 mm) for enhanced sensitivity |
| Control Platform | Industrial-grade panel PC with embedded real-time OS |
| Brand | Hach |
|---|---|
| Origin | Imported |
| Manufacturer | Hach Company |
| Instrument Type | Portable |
| Detection Principle | Colorimetric Spectrophotometry |
| Measurable Metals | As, Cr(Total), Cr(VI), Cu, Ni, Zn, Cd, Pb |
| Measurement Range (Typical) | As 0–4000 ppb |
| Reagent Catalog Numbers | 2822800, 2242500, 1271099, 2105869, 2651600, 2429300, TNT852, TNT850 |
| Kit Configurations | HM01 (DR2800 + battery + MP6P probe), HM02 (DR2800 + battery + H170NP pH/ORP probe + PHW77-SS stainless steel probe), HM03 (no DR2800, includes MP6P), HM04 (no DR2800, includes H170NP + PHW77-SS) |
| Compliance | Designed for field use in accordance with EPA Method 200.7, ISO 11969, and ASTM D3559/D5191 for metals analysis in water |
| Brand | Lanjing |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Manufacturer |
| Product Category | Domestic |
| Model | LJ-TZMn |
| Instrument Type | Benchtop Laboratory Analyzer |
| Detection Principle | Photometric Method (Formaldehyde Oxime & Potassium Periodate) |
| Target Analyte | Total Manganese (Mn) |
| Detection Range | 0–5 mg/L |
| Detection Limit | 0.1 mg/L |
| Accuracy | ≤ ±5% FS |
| Stability | < 0.5% (20 min) |
| Repeatability | < 0.5% RSD |
| Optical Drift | ≤ 0.002 A in 20 min |
| Light Source | Imported High-Brightness LED with Auto-Calibration |
| Cuvette Compatibility | 10 mm, 30 mm, 50 mm rectangular cuvettes & φ16 mm round tubes |
| Display | 8-inch TFT-LCD Touchscreen (1024 × 768) |
| OS | Android 7.1.1 |
| Data Storage | 8 million records |
| Connectivity | Wi-Fi, RJ45, Bluetooth, Mobile Hotspot, USB 2.0, HDMI |
| Cloud Platform | Integrated Regulatory Compliance Cloud (LAN/WAN upload |
| Printer | Built-in Thermal Line Printer (QR code supported) |
| Power Supply | AC 220 V ±10%, 50 Hz / Optional 6 Ah Li-ion Battery |
| Dimensions | 367 × 243 × 125 mm |
| Weight | 5.3 kg |
| Operating Environment | 5–40 °C, RH < 85% (non-condensing) |
| Rated Power | 10 W |