High Pressure Sterilizer
Filter
Showing 31–37 of 37 results
| Brand | Shen'an / She Medical Devices |
|---|---|
| Origin | Shanghai, China |
| Model | LDZX-50L-I |
| Instrument Type | Vertical Autoclave |
| Maximum Temperature | 126 °C |
| Maximum Pressure | 0.24 MPa |
| Chamber Volume | 50 L |
| Chamber Dimensions | Ø350 × 550 mm |
| External Dimensions | 550 × 620 × 1070 mm |
| Power Supply | 220 V / 50 Hz |
| Rated Power | 3.5 kW |
| Chamber Wall Thickness | ≥2 mm |
| Design Service Life | ≥10 years |
| Safety Certification | China Special Equipment Pressure Vessel Certificate (GB/T 150 & TSG 21 compliant) |
| Brand | Shen'an / She Medical Devices |
|---|---|
| Origin | Shanghai, China |
| Model | LDZX-75L-I |
| Instrument Type | Vertical |
| Max Temperature | 128 °C |
| Max Working Pressure | 0.165 MPa |
| Chamber Dimensions | Ø350 mm × 700 mm |
| Chamber Volume | 75 L |
| External Dimensions | 670 mm × 580 mm × 1395 mm |
| Net Weight | 105 kg |
| Rated Power | 3.5 kW |
| Voltage/Frequency | 220 V / 50 Hz |
| Design Pressure | 0.23 MPa |
| Rated Operating Pressure | 0.142 MPa |
| Temperature Range | 50–126 °C |
| Time Range | 0–99 h |
| Safety Certification | China Special Equipment Pressure Vessel Certificate (GB/T 150 & TSG 21 compliant) |
| Brand | Systec |
|---|---|
| Origin | Germany |
| Model | D-Series |
| Instrument Type | Benchtop Sterilizer |
| Max Temperature | 140 °C |
| Max Pressure | 4 bar |
| Chamber Dimensions | 500 × 750 mm (D-150/D-200) |
| External Dimensions | 850 × 730 × 1300 mm |
| Chamber Volume | 200 L (D-200) |
| Power Supply | D-45: 220–240 V, 50/60 Hz, 16 A |
| D-65 to D-200 | 380–400 V, 50/60 Hz, 16 A |
| Construction | Fully stainless steel (AISI 304) chamber, outer casing and support frame |
| Control System | Microprocessor-based with LCD interface, 25 programmable cycles (DX), 12 (DE), or 4 (DB) |
| Data Logging | Up to 500 sterilization cycles stored internally |
| Connectivity | RS-232 and RS-485 ports for network integration |
| Safety Compliance | EN 285, EN 61010-1, PED 2014/68/EU, CE-marked |
| Brand | TOMY |
|---|---|
| Origin | Japan |
| Model(s) | SX300, SX500, SX700 |
| Sterilization Temp Range | 105–135°C (0.019–0.212 MPa) |
| Heating Temp Range | 45–104°C (0–0.015 MPa) |
| Holding Temp Range | 45–95°C |
| Max Working Pressure | 0.25–0.263 MPa |
| Chamber Capacity | 44 L / 58 L / 79 L (effective volume) |
| Chamber Material | SUS304 stainless steel |
| Temperature Sensor | Separated-type RTD probe positioned at chamber center |
| Pressure Sensor | Dual-balance diaphragm pressure transducer system |
| Water Level Detection | Conductivity-based automatic low-water sensor with auto-shutdown |
| Cooling System | Two-stage adjustable forced-air fan (reduces 121°C → 97°C in ≤12 min for 3 L load) |
| Safety Features | Dual interlocked lid mechanism, overpressure relief valve, thermal cut-off, ground-fault circuit interrupter, lid-temperature sensor, pressure safety valve |
| Power Supply | 230 VAC, 50 Hz |
| Input Power | 1.5 kW / 2.0 kW / 3.0 kW |
| Compliance | JIS B 8225, Japanese Pressure Vessel Safety Regulations (Type Approval certified), GLP/GMP-ready data traceability support |
| Brand | YAMATO |
|---|---|
| Origin | Japan |
| Model | SN310C |
| Type | Vertical Sterilizer |
| Max Temperature | 135 °C |
| Max Pressure | 0.255 MPa |
| Operating Temperature Range | 45–135 °C (with programmable sub-ranges: 45–80 °C preheat, 45–60 °C keep-warm, 65–100 °C dissolution, 105–135 °C sterilization) |
| Heating Power | 2 × 800 W (100 V) |
| Cooling | Integrated axial-flow fan |
| Safety | Triple mechanical pressure-lid interlock system |
| Voltage Options | AC 100–120 V or AC 200–240 V |
| Ambient Operating Temperature | 5–35 °C |
| Control System | Microprocessor-based PID temperature control with digital keypad interface and real-time display |
| Interface Ports | 1/4″ sample sensor port, 1/4″ chart recorder port, pressure gauge port with solenoid valve branch |
| Brand | YAMATO |
|---|---|
| Origin | Japan |
| Model | SQ510C |
| Instrument Type | Vertical Sterilizer |
| Max Temperature | 135 °C |
| Max Pressure | 0.255 MPa |
| Chamber Dimensions | Ø370 × 465 mm (H) |
| External Dimensions | 520 × 660 × 901 mm (W × D × H) |
| Chamber Volume | 50 L |
| Heating Power | 2 × 1000 W |
| Cooling | Integrated Axial Fan |
| Operating Ambient Temperature | 5–35 °C |
| Power Supply Options | AC 100–120 V (20.5–24.5 A) or AC 200–240 V (10.5–12.5 A) |
| Safety | Triple Interlocked Lid Lock System |
| Control | Microprocessor-based PID with Digital Keypad Interface |
| Brand | YAMATO |
|---|---|
| Origin | Japan |
| Model | SQ810C |
| Instrument Type | Vertical |
| Max Temperature | 135 °C |
| Max Pressure | 0.255 MPa |
| Chamber Dimensions | Ø370 × 744 mm |
| External Dimensions | 520 × 660 × 1125 mm |
| Chamber Volume | 80 L |
| Heating Power | 4000 W |
| Operating Ambient Temperature | 5–35 °C |
| Standard Cooling Fan | Yes |
| Safety Locks | Triple Interlocked Lid Mechanism |
| Voltage Options | AC 100–120 V (20.5–24.5 A) / AC 200–240 V (10.5–12.5 A) |
| Temperature Control | Microprocessor-based PID with Digital Keypad Interface |
| Programmable Stages | Preheating (45–80 °C), Holding (45–60 °C), Dissolution (65–100 °C), Sterilization (105–135 °C) |